Powrmatic Vision 2.3 Twin Duct User guide

Issue 1.0 July 2014
GB & IE H E A T I N G / / V E N T I L A T I O N / / A I R C O N D I T I O N I N G
Vision 2.3 Twin Duct
Air Conditioner/Heat Pump
Optional Low Pressure Hot Water Fan Coil Model Available
www . p o w r m a tic . c o .uk
Vision2.3
Installation, Servicing, and Users
Instructions

Page 2 Vision 2.3 Air Condioner Range Issue 1.0 June 2014
Installer
Date :_____________ Signed ____________________________________________Installer
Commissioned
Date :_____________ Signed _______________________________Commissioning Engineer
powrmatic
Certicate of Guarantee
Dear Customer
This is to certify that this air conditioner has a limited one year warranty from the date of
original commissioning. The air conditioner must be commissioned within 4 weeks of
installation.
To make a claim
In the first instance you must contact your appliance supplier, or installer and provide:-
1. The appliance type and serial number.
2. The original commissioning documentation.
3. As much detail as possible on the fault.
Your supplier, or installer, will then contact Powrmatic to make a guarantee claim
on your behalf.
Conditions of Guarantee
1. The air conditioner must have been installed by a competent recognised
installer, and in accordance with the manufactures instructions, building
regulations and local regulations.
2. The air conditioner has been professionally commissioned, within 4 weeks of
installation, and a copy of the Commissioning sheet returned to Powrmatic.
3. The air conditioner has been maintained on a yearly basis by a competent
servicing company.
4. The air conditioner has been used in accordance with the manufactures
instructions.
5. The correct specification voltage has been used.
6. No unauthorised repairs or modifications have been made.
7. Powrmatic ‘General Conditions of Sales’ have been observed.
8. Except for the obligation of Powrmatic Ltd to perform warranty repairs during the
guarantee period Powrmatic will not be liable in respect of any claim for direct or
indirect consequential losses, including loss of profit or increased cost arising
from loss of use of the air conditioner, or any event arising there from.
-------------------------------------------------------------------
Powrmatic Ltd. Hort Bridge, Ilminster, Somerset, TA19 9PS
Tel: 01460 53535 Fax: 01460 52341
Important :This certificate must
be kept with the appliance

Dear Customer - thank you for choosing Powrmac.
We appreciate you buying one of our high quality products and know that you have made the best
choice. We pride ourselves by manufacturing products that provide clean, comfortable and safe
working environments worldwide together with the personal & professional service and back-up you
deserve. If you have any quesons or concerns regarding this product, please contact our Technical
Support Team by calling 01460 53535.
Vision 2.3 Air Condioner Range Issue 1.0 June 2014 Page 3
This unit complies with European direcves:
•Low voltage 2006/95/EC
• Electro-magnec compability 2004/108/EC
• Use restricons of hazardous substances in
electrical and electronic 2011/65/EC
(RoHS2)
• Waste electrical and electronic equipment
2002/96/EC(WEEE)
• Energy consumpon indicaon on the labels
of energy related products 2010/30/EU
Compliance
Symbols
Pictograms in the next chapter provides the neces-
sary informaon for a correct and safe use of the
machine in a rapid, unmistakable way.
Editorial pictograms
UUser
Refers to pages containing instrucons of
informaon for the user.
I Installer
Refers to pages containing instrucons or
informaon for the installer.
SService
Refers to pages containing instrucons or
informaon for the CUSTOMER TECHNICAL
ASSISTANCE SERVICE installer.
Safety pictograms
Warning
It indicates acons that require cauon and a
suitable preparaon.
Do Not
Refers to acons that absolutely must not be
performed.

Users, Installaon, Servicing and User Instrucons
CONTENTS
Title Secon Contents Page
General
1.1 General warning 5
1.2 Fundamental safety rules 5
1.3 Descripon 6
1.4 Receipt and unpacking 6
1.5 Storage 6
1.6 Handling 6
1.7 Shipping dimensions and weight 7
1.8 Supplied components 7
1.9 Unit parts 8
Installaon
2.1 Installaon mode 9
2.2 Choosing the posion of the unit 9
2.3 Assembling the unit 10
2.4 Assembling air ducts and external shuers 12
2.5 Mounng the appliance on the bracket 13
2.6 Electrical connecon 13
2.7 High/Low installaon configuraon 14
2.8 Seng cool only or heat only modes 16
2.9 Touch-screen display key lock 16
2.10 Operaons tests and anomaly diagnosis 16
Troubleshoong
3.1 Periodic Maintenance 17
3.2 Troubleshoong 18
3.3 Technical data 19
User Manual
4.1 Management of the appliance with the
touch-screen display 20
4.2 Managing the appliance with the remote
control 20
4.3 Descripon of machine funconing 21
4.4 Advice for energy saving 23
Page 4 Vision 2.3 Air Condioner Range Issue 1.0 June 2014

After unpacking, check that the contents are
intact and that all parts are included. If they are
not, please contact the supplier who sold you the
appliance.
The appliance must be installed by an autho-
rised Installer. Once the work is done, they must
issue a declaration of conformity to the client in
compliance with current regulations and with
indications on this instruction manual supplied
with the appliance.
These appliances have been designed for condi-
tioning and heating rooms, and they must be
destined solely for this purpose compatible with
their performance characteristics.
The manufacturer refuses any contractual or
extra-contractual responsibilities for damage
caused to people, animals, or things resulting
from incorrect installation, adjustment, mainte-
nance or improper use.
In the event of water leaks, turn off the main
switch and close the water taps.
Immediately call the Technical Assistance
service or other qualified personnel and do not
intervene personally on the appliance.
If the temperature is set too low or too high, not
only will it be unhealthy, but it is also a waste of
energy. Avoid prolonged direct contact with the
air flow.
Do not leave the room closed for long periods.
Open the windows periodically to change the air.
This instruction booklet is an integral part of the
appliance and therefore it must be kept safely
and must ALWAYS accompany the appliance
even when the later is transferred to another
owner or user, or moved or sold. If it gets dam-
aged or lost, please request another copy.
Any repair or maintenance operation must be
performed by a qualified person in accordance
with this booklet. Do not modify or tamper with
the appliance as this could lead potential danger
and the manufacturer will not be liable for any
damage caused.
Vision 2.3 Air Condioner Range Issue 1.0 June 2014 Page 5
1.1 General Warning (UIS)
1.2 Fundamental safety rules (UIS)
We would like to remind you that some funda-
mental safety rules should be followed when
using products that work with electricity and
water.
The use of the appliance by children and unas-
sisted disabled persons if forbidden.
It is forbidden to touch the appliance if barefoot-
ed or with wet or damp parts of the body.
It is forbidden to clean the appliance without
having first disconnected the appliance from the
mains power supply by turning off the mains
switch.
It is forbidden to modify or adjust safety devices
without authorisation and instructions from the
manufacturer.
It is forbidden to pull out or twist the electric
cables coming out of the appliance, even if they
are disconnected from the pains power supply.
It is forbidden to introduce objects and substanc-
es though the air inlet and outlet grids.
It is forbidden to open the access doors to the
internal parts or the appliance without having
turned off the mains switch first.
It is forbidden to leave the packing material
within the reach of children as they could be a
source of danger. This material should be recy-
cled or disposed of properly.
It is forbidden to climb onto the appliance and/or
to place any type of object on top of it.

1.3 Description (UIS)
The Vision 2.3 is the new solution by Powrmatic, a signifi-
cant step towards reducing the aesthetic impact of air
conditioners. Being only 16 centimetres deep, the Vision
2.3 is the thinnest and less bulky in this category, there-
fore both the internal and external aesthetic impact is kept
to a minimum.
Optimised Capacities
The conditioning capacity of the Vision 2.3 have been
optimised so as to obtain the right temperature for the
best level of comfort and, therefore less consumption and
less noise. Thanks to the careful choice of sound insula-
tion materials, the noise is similar to that of a standard
wall split unit and consumption is drastically contained
thanks to the new direct current fan.
162 millimetre holes
An important choice, not only design-wise, but also
because of a considerable installation advantage: it is
easier to find drilling tools, with lower aesthetic impact.
Easy to install
The Vision 2.3 can be installed on any perimeter wall
either low or high. Everything needed for installation
(template, support bracket, hole pipes and external grids),
excluding the drill, is included in the box.
Folding external grids
Remote control and touch screen display.
In addition to the remote control, the touch screen display
on the unit enables the setting of any function. There is
even a ‘lock’ mode to avoid any improper use. It is possi-
ble to deactivate the ‘heating’ mode by simply touching
the screen. the unit then works in ‘cool only’ mode,
without the need to use the condensation drain pipe. The
orientation of the air flap can also be adjusted by simply
pressing one key.
Page 6 Vision 2.3 Air Condioner Range Issue 1.0 June 2014
1.4 Receipt and unpacking (UIS)
The packing is made of suitable material and carried out
by expert personnel. All units are checked and tested and
are delivered complete and in perfect condition. However
please perform the following instructions to check the
condition of the received product:
Upon receipt , check if the box is damaged. If
that is the case, accept the goods with reserva-
tions and keep photographic evidence of any
damage found.
Unpack and check the contents against the
packing list.
Check that none of the parts have been dam-
aged during shipment. In case of damage,
report it to the delivery company within 3 days of
receipt by registered letter with return receipt
and attaching photographic documentation. A
copy should also be sent by fax/email to the
MANUFACTURER. No notice of damage will be
accepted after 3 days from delivery.
Keep the packing for at least the length of the
warranty should you need to return the appli-
ance to the service centre for repair. dispose of
the packing materials in compliance with current
regulations on waste disposal.
-
-
-
1.5 Storage (UIS)
If the conditioner is not to be installed immediately, store
the box in a closed environment, protected from atmo-
spheric agents and isolate it from the floor using planks or
pallets.
Do not turn upside down.
1.6 Handling (UIS)
The unit is packed singularly in a cardboard box. Boxes
can either be carried singularly by hand by two operators
or loaded on trolley, maximum three units high.
Handling must be performed by qualified
personnel, with specific tools and with equip-
ment suitable for the weight of the equipment.
The appliance is unbalanced on the right (com-
pressor side)
During transportation, the appliance must be
kept in a upright position.

Vision 2.3 Air Condioner Range Issue 1.0 June 2014 Page 7
1.7 Shipping dimensions and weight (UIS)
Packing “Vision 2.3” 10 HP
Dimensions
Weight Kg 50
Length mm 1110
Height mm 660
Depth mm 260
1.8 Supplied components (UIS)
The air conditioner supplied comprises of the parts listed
in the following table. Before assembly, please check that
they are all included.
A External grids for air inlet and outlet with springs
and chains (2 pcs)
B Screws and plugs kit (6 pcs)
C Bracket for wall mounting
D User manual
E Remote control
F Paper template for holes
G CR2025 3V remote control battery
H Wall inlet pipes (2 pcs)
I Energy efficiency label
L Bottom cover
M Screws for mounting the bottom cover (2 pcs)
N Installation manual
O Internal flange (2 pcs)

Page 8 Vision 2.3 Air Condioner Range Issue 1.0 June 2014
1.9 Unit parts (UIS)
1 Air outlet flaps
2 Touch-screen display
3 Front panel
4 Outdoor air suction
5 Outdoor air outlet
6 Air suction grid
7 Air filters
8 Outdoor air outlet fan
9 Outdoor air heat exchanger
10 Compressor
11 Indoor air heat exchanger
12 Electronic board

Vision 2.3 Air Condioner Range Issue 1.0 June 2014 Page 9
2.1Installation mode (I)
Before installing the conditioner, it is essential to calculate
the summer thermal loads (and winter ones for the
models with a heat pump) of the room. The more accu-
rate calculations, the better the product will work. Please
refer to current regulations to carry out calculations. For
big installations please call a study specialised in thermo-
dynamics. Try to reduce the thermal refrigeration load of
the room following these instructions:
Cover large windows exposed to sunlight with curtains or
with external masking (blinds, porches, reflecting films
etc.)
The room must remain closed for as long as possible.
Avoid using halogen lamps or other high energy
consumption appliances such as small ovens, steam
irons, cooking plates etc.
2.2 Choosing the position of the unit (I)
For a better performance of the appliance and to avoid
malfunctions or dangerous situations, the location of the
unit must meet the following requisites:
Respect the minimum distances indicated in the
picture.
The wall on which you wish to anchor the unit
must be robust to support its weight.
Leave enough space around the unit to perform
maintenance operations.
Nothing must obstruct the air flow both in the top
suction part (curtains, plants, furniture) and in
the lower outlet part, as it could cause vibrations
which might prevent the appliance form working
correctly.
The appliance must be installed against a wall
connecting with the outside.
Check that there are no structures or systems
(beams, pillars, hydraulic pipes, electrical cables
etc.) in the part of the wall that must be drilled.
Check that nothing is placed in front of the holes
thus obstructing the air flow (plants and leaves,
panels, shutters, grates, etc)
The unit should not be installed in a position
where the air flow aims directly at people nearby.
Do not force the air flap open.
The appliance must not be installed directly
above, or below another electrical appliance
(TV, radio, fridge, etc.) or above a source of
heat.
-
-
-
-

Page 10 Vision 2.3 Air Condioner Range Issue 1.0 June 2014
2.3 Assembling the unit (I)
The maximum length of the holes is of 1 m and
there must be no bends. Use the supplied grids
or grids with the same characteristics.
For the unit to work, two holes must be placed as indicat-
ed on the template.
The holes on the wall must be drilled using suitable equip-
ment that does not cause damage or excessive inconve-
nience to your client. The best tools to make big holes are
special drills (called “core drills”) with a high torque and
whose speed can be adjusted according to the diameter
of the hole and the material to be drilled. In order to avoid
excesses dust and debris in the room, “core drills” can be
combined with suction systems composed of a vacuum
connected and a suction cup which can be placed next to
the drill. In order to make the holes, proceed as follows.
Place the template provided against the wall,
respecting the minimum distances from the
ceiling, the floor, and the side walls, as indicated
on the template. The template can be held in
place using adhesive tape. A spirit level can be
used to ensure the unit is square.
Mark the centre of each hole with a small drill or
a punch before actual drilling commences.
Using the core drill, make two holes for the inlet
and outlet air.
The holes must be drilled slightly downward
towards the outside, to avoid water from entering
the building.
The majority of the removed material is expelled outwards
so please be careful that it does not hit people or objects.
In order to avoid breaking the outer plaster, be careful
while drilling the final part of the hole and ease the pres-
sure on the core drill.
Drill the 6 holes for the bracket as indicated on the
template.
The appliance weights more on the right side, so make
sure it is properly supported on this side. The holes must
have an 8mm diameter to accommodate the 6 supplied
plugs.
In any case, check the characteristics and the consisten-
cy of the wall to see whether specific plugs may be
needed.
The manufacturer cannot be held responsible for
any underestimates or the structural consistency
of the anchoring arrangement made by the
installer. We therefore encourage you to pay the
utmost attention to the operation, as if performed
badly it could cause serious injury or damage.
Drill a hole in the position indicated on the template for
those heat pump appliances without a condensation drain
built in the wall in order to enable the drainage of conden-
sation.
-
-
-
A Holes for M8 Plugs
B Electrical connection area
C Ø162mm holes for air channelling
D Ø14mm condensation drain

Vision 2.3 Air Condioner Range Issue 1.0 June 2014 Page 11
2.1 Fitting the unit
Condensation drain predisposition
For heat pump appliances, a condensation drain pipe
(Ø10mm, internal, not supplied) must be connected to the
pipe on the top part of the appliance.
A solenoid valve will start the flow of the condensation
from the internal collection tray when the maximum level
has been reached. For cooling only appliances, said pipe
must be connected if the appliance is going to be used
with low external temperatures, (below 23oC). As it is a
gravity drain, it is essential for the line to have at least 3%
slope minimum at every point. A rigid or flexible pipe can
be used with a minimum internal diameter of 10mm. If the
line flows into a sewage system, it is necessary to be
trapped before connecting to the drain. Said trap must be
placed at least 300mm under the mouth of the appliance.
If the line flows into a container (e.g. a tank) do
not close the container hermetically and avoid
immersing the draining pipe into the water.
The hole for the condensation pipe must always
lean towards the outside.
The exact position in which to place the pipe
mouth is indicated on the template.
Check that the expelled water does not cause
any damage, or problem to people or objects.
During winter this condensation can freeze to
form ice on pathways.
When connecting the condensation drain, be
careful not to squeeze the rubber duct.
It is possible to empty the collecting tray using
the safety drain at the base of the appliance if
necessary.
1 Safety drain to empty tray
2 Condensation drain duct

Page 12 Vision 2.3 Air Condioner Range Issue 1.0 June 2014
2.4 Assembling air ducts
and external shutters (I)
Once the holes have been made, place the supplied
plastic sheet inside them.
Roll up the sheet and insert it in the hole, checking that
the joint is facing upwards.
Use a cutter to remove any excess pipe.
To place the external grids, proceed as follows:
Connect the chains to the ends of the springs.
Fold the external shutters.
Insert your arm in the hole to push the shutter to
the outside, whist holding the the chain with the
other hand to prevent the shutter from falling.
Open the shutter inside the hole.
Rotate the shutter to bring the flat into the verti-
cal “C” position and check that the closing mech-
anism works.
Pull the chains by tensioning the springs.
Insert the internal flange in the hole with the
internal hooks in the vertical position.
Fix the chains to the internal flange’s hooks
Use a bolt cutter to remove any excess chain.
Anchor the hook of the chain to wall “B”.
Use only the supplied grids or grids with the
same characteristics.
The grids must be positioned with the flaps verti-
cal.
The shutters are different. Check the opening of
the shutter to determine if they are the inlet or
outlet shutter, and fit accordingly.
A Junction line
B Internal flange
C Flap in vertical position
-
-
-
-
-
-
-
-
-
OUT
IN

Vision 2.3 Air Condioner Range Issue 1.0 June 2014 Page 13
2.5 Mounting the appliance on the bracket (I)
After checking that the bracket is anchored to the wall and
that all necessary electrical connections and condensa-
tion drain have been made, you can mount the condition-
er. Lift it by the sides of the bottom base until the bracket
fits on all of the right spots on the appliance. In order to
ease the operation, slightly tilt the appliance towards you.
Direct electrical connections (disconnecting the power
supply cable) and the anchoring of the condensation
drain must be carried out after having spaced the appli-
ance from the wall using wooden wedges or any other
similar object.
Once the work is done, check that there are no openings
on the back of the appliance especially where the air
ducts are connected.
1 Bracket
2 Bracket anchoring points
2.6 Electrical connection (I)
The appliance is equipped with a power cord and plug
(Y-type connection, the cord can only be replaced by the
manufacturer, the assistance centre or a qualified install-
er) If using a socket near the appliance, insert the plug.
Before connecting the conditioner check that:
The power supply voltage and frequency values
comply with the data plate of the appliance.
The power supply line is provided with a suitable
earth connection and that it is dimensional for
the maximum absorption of the conditioner (min-
imum cable section equal to 1.5mm2)
Power is only supplied using a suitable socket
through a supplied plug.
The power cord must be replaced only by the
technical assistance service or by authorised
personnel.
The appliance must be connected to 230V/50Hz
mains via an omnipolar switch with a contact
opening distance of a minimum of 3mm, or using
a device enabling the complete disconnection of
the appliance in overvoltage III category condi-
tions.
It is possible to carry out the electrical connection using a
cable inside of the wall as indicated in the installation
template (recommended for installations in the upper part
of the wall)
Please check that the power supply is provided with
suitable protections against overloads and/or short
circuits (using a 10 at delay fuse or other equivalent
devices is recommended)
This operation must be performed only by the
installer or by authorised personnel in compli-
ance with current national regulations.
-
-
-
It is essential to disconnect the main switch before making
any connection or maintenance operation in order to
avoid any risk of electrocution.
To carry out direct connections and substitute the power
cord using the cable in the wall, proceed as follows:
Space the appliance from the wall using wooden
wedge or a small object.
Disconnect the power cord by unscrewing the 3
screws from the terminal board.
Connect the wall cable checking that the power
supply line is provided with a suitable earth
connection and that it is dimensioned for the
maximum absorption of the conditioner (mini-
mum cable section equal to 1.5mm2)
These operations must be carried out with the
appliance already placed on the bracket, there-
fore read the following instructions carefully
before completing the connection.
CP presence contact input connec-
tion
When the CP contact opens (connected to a free non-live
contact) the appliance is put in standby and CP appears
on the display.
Using this contact it is possible to connect an external
device that inhibits the function of the appliance such as
open window contact, remote control on/off, infrared pres-
ence sensor, qualification badge etc.
A 230V50Hz Electrical power supply terminal board
B CP pressence contact

Page 14 Vision 2.3 Air Condioner Range Issue 1.0 June 2014
The appliance is equipped with a power cord and plug
(Y-type connection, the cord can only be replaced by the
manufacturer, the assistance centre or a qualified install-
er) If using a socket near the appliance, insert the plug.
Before connecting the conditioner check that:
The power supply voltage and frequency values
comply with the data plate of the appliance.
The power supply line is provided with a suitable
earth connection and that it is dimensional for
the maximum absorption of the conditioner (min-
imum cable section equal to 1.5mm2)
Power is only supplied using a suitable socket
through a supplied plug.
The power cord must be replaced only by the
technical assistance service or by authorised
personnel.
The appliance must be connected to 230V/50Hz
mains via an omnipolar switch with a contact
opening distance of a minimum of 3mm, or using
a device enabling the complete disconnection of
the appliance in overvoltage III category condi-
tions.
It is possible to carry out the electrical connection using a
cable inside of the wall as indicated in the installation
template (recommended for installations in the upper part
of the wall)
Please check that the power supply is provided with
suitable protections against overloads and/or short
circuits (using a 10 at delay fuse or other equivalent
devices is recommended)
This operation must be performed only by the
installer or by authorised personnel in compli-
ance with current national regulations.
It is essential to disconnect the main switch before making
any connection or maintenance operation in order to
avoid any risk of electrocution.
To carry out direct connections and substitute the power
cord using the cable in the wall, proceed as follows:
Space the appliance from the wall using wooden
wedge or a small object.
Disconnect the power cord by unscrewing the 3
screws from the terminal board.
Connect the wall cable checking that the power
supply line is provided with a suitable earth
connection and that it is dimensioned for the
maximum absorption of the conditioner (mini-
mum cable section equal to 1.5mm2)
These operations must be carried out with the
appliance already placed on the bracket, there-
fore read the following instructions carefully
before completing the connection.
CP presence contact input connec-
tion
When the CP contact opens (connected to a free non-live
contact) the appliance is put in standby and CP appears
on the display.
Using this contact it is possible to connect an external
device that inhibits the function of the appliance such as
open window contact, remote control on/off, infrared pres-
ence sensor, qualification badge etc.
A 230V50Hz Electrical power supply terminal board
B CP pressence contact
-
-
-
2.7 High/Low installation configuration (I)
The unit can be installed either at high level or low level on
the wall, in order to optimise air distribution and comfort,
the direction of the air flow can be modified by adjusting
the position of the air flap.
The appliance is supplied ready to be installed in the
lower part of the way, so air is dispensed upwards. The
same configuration can also be used high on the wall in
cooling mode, which increases the air flow in the room
(coanda effect)
This operation must be performed whilst the
appliance is switched off and disconnected.
Modifications from lower wall to the
upper wall position
Open the air outlet flap gently.
Remove the flap opening block insert located
internally on the air outlet mouth and place it in
the lower hole.
Remove the upper grill.
Remove the two plastic side panels by moving
them up.
Unscrew the fixing screws
Remove the front panel
Place the bottom cover and fix it with the
supplied screws.
Refit in the reverse order.
1 Block insert
2 Bottom cover
3 Fixing screws
4 Upper grill
5 Plastic side panels
6 Front panel
-
-
-
-
-
-
-
-

Vision 2.3 Air Condioner Range Issue 1.0 June 2014 Page 15
After adjusting the air outlet flap position, it is necessary to
set up the electronic control of the appliance:
Press and hold the button on the display for
5 seconds.
The “dn” (lower wall) symbol lights up on the
display.
Press the button again.
The “uP” (upper wall) symbol lights up on the
display.
If no other operations are performed in the
following 2 seconds, the new setting is memo-
rised.
For the appliance to work properly, each time the
configuration of the air outlet flap is modified the
electronic control must be set.
-
-
-
-
-

Page 16 Vision 2.3 Air Condioner Range Issue 1.0 June 2014
2.8 Setting cool only or heat only modes (I)
It is possible to deactivate the heating or the cooling
modes following a simple procedure.
Pres and hold the “A” key for 5 seconds until the “HC”
(heating and cooling) appears on the display.
Press the “A” key for 1 second for the Co (cooling only)
mode.
Press the “A” key for Ho (heating only) mode.
Wait for 3 seconds without touching anything to memorise
the setting.
2.9 Touch-screen display key lock (I)
The key lock is activated by press and hold the Timer
symbol for 3 second.
The key pad is then locked and no operations are avail-
able to the user.
The stand-by symbol flashes at 1 second intervals.
To deactivate the lock, press and hold the Timer
symbol for 3 seconds.
Any key on the remote control will also deactivate the
lock!
2.10 Operations, tests
and anomaly diagnosis (I)
The conditioner can perform a short self-diagnosis cycle
to check the temperatures detected by the 4 probes and
the status of the 3 inlets.
In order to activate the self diagnosis function, press the
button within 10 seconds from the electric power
being turned on.
The display will light all symbols for 2 seconds and then it
will show the 7 test information at 2 second intervals.
After 5 cycles, or when any key is pressed either in the
display or on the remote control, the self diagnosis mode
will stop.
If the conditioner stops because of an alarm (see the
following table), please contact the supplier with the code.
Display code Cause
E1 Broken room temperature RT probe
E2 Broken evaporative battery IPT probe
E3 Broken outdoor air temperature OT probe
E4 Broken conditioner battery OPT probe
E5 Broken indoor air fan motor
E6 Broken outdoor air fan
E7 Lack of communication with the display
Open CP contact
If the contact is not closed on the CP connections the
appliance will not start and the CP alarm appears on the
display.
Emergency condensation air dis-
charge
Should any anomaly occur in the condensation water
system, the maximum level float blocks the conditioner
and the OF code appears on the display.
During cooling and dehumidification, electronics switch
the compressor off and keeps the water distribution
system active with the battery - together with the fan - to
disperse excess water in the container. If the problem
persists, please contact the assistance service.
During heating, condensation should drain freely through
the specific pipe. In the event of an alarm, check that the
condensation pipe is not bent or obstructed, thus prevent-
ing the water from flowing out.
Operation after installing
Before leaving, collect the packaging and clean any dust
on the appliance with a damp cloth. These operations,
though not strictly essential, transmit a sense of profes-
sionalism to the user.
In order to avoid unnecessary calls from the user, it is
best, before leaving to :
Explain the contents of the Manual.
Explain how to clean the filter.
Clarify when and how to call the Assistance
Service.
-
-
-

Vision 2.3 Air Condioner Range Issue 1.0 June 2014 Page 17
3.1Periodic Maintenance (S)
The air conditioner you have bought has been designed
to keep maintenance operations to a minimum, which
only concern the following cleaning operations.
External cleaning
Before any cleaning and maintenance operation
disconnect the unit from the mains by switching
off the mains switch.
Wait until the parts have cooled down to avoid
getting burned.
Do not use abrasive sponges or abrasive or
corrosive detergents to avoid damaging the
varnished surfaces.
When necessary, clean the external surfaces with a soft
damp cloth.
Cleaning filter
The air conditioner you have bought has been designed
to keep maintenance operations to a minimum, which
only concern the following cleaning operations:
Clean the air filter after a period of continuous
use and in accordance with the concentration of
impurities in the air, or when you wish to start-up
the appliance after a period of inactivity.
The filter is placed on the top part of the appli-
ance.
To extract the filters:
Open the grid and remove it.
Extract the filter by lifting them.
Remove the dust from the filter with a vacuum
cleaner or wash the unit in running water without
detergents or solvents and leave to dry.
Put the filters back on top of the batteries, taking
care to position them correctly.
Put the grid back.
Check that the panel is mounted correctly after
cleaning operations.
Using the appliance without the filter is prohibit-
ed.
-
-
-
-
-
-
-

Page 18 Vision 2.3 Air Condioner Range Issue 1.0 June 2014
3.2 Troubleshooting (S)
In case of a malfunction, please refer to the following
table. If, after performing the suggested checks, the prob-
lem is not solved, please contact the authorised technical
assistance.
Anomaly Possible cause Solution
The appliance No power supply Check you have a power supply to the unit (try turning on a
does not switch light switch, or plugging in another electrical device.)
on. Check that the exclusive magneto-thermic switch that
protects the appliance has not engaged (if it has, reset it). If
the problem repeats immediately contact the supplier for
assistance)
Batteries have run out Check that the appliance turns on by the touch screen display,
and change batteries.
The appliance The set temperature is too high Check and adjust the temperature on the remote.
does not cool/ or too low.
heat enough. The air filter is clogged. Check the air filter and clean if it is necessary.
Check that there is no other Remove anything that might block the air flow.
obstructions blocking air flow
either internally or externally
The thermal refrigeration load has Try to reduce the thermal refrigeration load of the room with
increased (for example, a door or the following advice:
window has been left open or an Cover large windows exposed to sunlight with curtains or
appliance has been installed in the with external masking (blinds, porches, reflecting films. etc)
room, generating heat (ie computer, The room must remain closed for as long as possible.
or fridge)) Avoid turning on halogen lamps or other high energy
consumption appliances such as small ovens, steam irons,
cooking plates etc.)
Display alarms
An alarm code appears on the display in case of anoma-
lies. Some of the functions remain active (see FUNC-
TIONING column)
The only way to solve the problem is to disconnect and
reconnect the appliance, if the alarm still appears, please
contact the authorised technical assistance.
Alarm display Code Functioning
E1 Broken room temperature RT sensor It is still possible to activate the Cooling, Dehumidification
and Heating modes. It only monitors the antifreeze function
of the internal battery.
E2 Broken internal battery IPT sensor None of the functioning modes work.
E3 Broken outside temperature OT None of the functioning modes work.
sensor
E4 Broken out side battery OPT sensor It is still possible to activate the Cooling, Dehumidification
and heating modes. Defrosting is performed at fixed times.
E5 Broken internal ventilator motor None of the functioning modes work.
E6 Broken external ventilator motor None of the functioning modes work.
E7 Lack of communication with the None of the functioning modes work.
display
CP Open CP contact The appliance only works if the contact is closed. Check
that the clamps are connected.
OF Maximum level float intervention During cooling and dehumidification, electronics switches
the compressor off and keeps the water distribution system
active with the battery - together with the fan - to disperse
excess water in the container. During heating,
condensations should drain freely through he specific pipe.
In the event of an alarm, check that the condensation pipe is
not bent or obstructed, thus preventing the water from
flowing out.

Vision 2.3 Air Condioner Range Issue 1.0 June 2014 Page 19
3.3 Technical data (S)
Please read the data plates to obtain the technical data
listed below.
Power supply voltage
Maximum absorbed power
Maximum absorbed current
Amount of refrigerant gas
Casing protection level
Max. Working pressure
-
-
-
-
-
-
-
Technical data U.M. Vision 2.3 10HP
Cooling power (1) kW 2.30
Heating power (2) kW 2.25
Power absorbed when cooling (1) W 850
Power absorbed when heating (2) W 725
Annual energy consumption for cooling (1) kWh 425
Dehumidification capacity l/h 1.1
Power supply voltage V-F-Hz 230-1-50
EER W/W 2.71
COP W/W 3.10
Energy efficiency rating when cooling A
Energy efficiency rating when heating A
Internal-external ventilation speed No. 3
Dimensions (WxHxD) mm 1030x555x170
Weight Kg 48
Noise level (min -max)* dB(A) 32/41
Wall holes diameter mm 162
Refrigerant gas R-401A
R410A refrigerant charge g 460
Maximum adsorbed power W 920
Maximum absorbed current A 4.1
Maximum working pressure PS MPa 3.8
Casing protection level IPXO
Refer conditions
Room t External t
(1) Cooling mode tests DB 27oC - WB 19oC DB 35oC - WB 24oC
(2) Heating mode tests DB 20oC - WB 15oC DB 7oC - WB 6oC
* Noise pressure measured 1 m away and 1.5 m high Regulation EN 14511.1.2.3.4
Operating limits
Internal ambient temp. Outside ambient temp.
Maximum operating temperature in cooling mode DB 35oC - WB 24oC DB 43oC - WB 32oC
Minimum operating temperature in cooling mode DB 18oC DB -5oC
Maximum operating temperature in heating DB 27oC DB 24oC - WB 18oC
Minimum operating temperature in heating DB 5oC DB -10oC

Page 20 Vision 2.3 Air Condioner Range Issue 1.0 June 2014
4.1 Management of the appliance
with the touch-screen displayd (u)
Normally, the display shows the operating status (see
Description of machine functioning paragraph) as well as
any alarms (see Display alarms paragraph).
In addition, it is possible to select the various functions by
pressing the symbols.
4.2 Management of the appliance
with the remote control (u)
It is possible to select the various modes by pressing the
buttons (see Description of machine functions para-
graph).
The remote control provided has been designed
to be functional and resilient, however it must be
handled cautiously.
Avoid:
Expose the remote control to fluids.
Dropping or hitting the remote control.
Leave exposed to direct sun light.
Obstruct between the remote and the appliance
whilst using it.
In addition:
If there are other appliances using remote
controls in the room (TV, radio, stereos, etc.),
interference may occur.
Electronic or fluorescent lamps can interfere with
communication between the remote and the
appliance.
Remove the battery if not using the remote for a
long period.
Battery insertion
Only CR2012 3V dry lithium batteries must be used (sup-
plied). Used batteries must be handed over to a specific
collection area as arranged by the Local Authorities for
this type of waste.
In order to insert the batteries, open the specific cover in
the bottom part of the remote. The battery must be insert-
ed respecting polarity. Once the battery is inserted close
the cover.
-
-
-
-
-
-
-
Table of contents
Other Powrmatic Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual