Burner Ignites But Water Temperature Is too low
1. The water flow may be so high as to exceed the
capacity of the heater particularly if your supply water
is very cold. Slow the water flow.
2. The gas pressure may be too low. Be sure the
gas flow control valve is in full “on” position.
3. Check the gas pressure while the water is on at
full flow. The LPG pressure should be the “manifold
pressure” as shown on the specification label while
the heater is running. A gas-testing gauge should be
installed on the manifold tap so that it may be read
while heater is running. If it is too low, turn up the gas
regulator to the proper pressure. This should only be
done by a qualified technician.
4. The gas flow may be too low due to improper gas
line diameter (under 3/8 inch outside diameter). The
gas line may be excessively long (over 20-30 feet) or
the on/off solenoid at the tank (if you have one) may
have an orifice that is too small (under 3/16th of an
inch).
5. Check the heater door louvers and flue pipe for
airflow obstructions and clean.
6. Check that the “summer / winter” valve is in the
proper position for the temperature of the incoming
water.
Water Temperature Is Too Hot or No Temperature
Control.
1. Fuel tank regulator is set too high and manifold
pressure as described above Have the regulator
checked by a qualified technician.
2. Water flow too low for incoming water
temperature.
Low Heat Rise and Excessive Water Flow Is
Required To Trigger Water Heater
If you find that your heater requires excessive flow to
activate it (much over .5 gallon per minute), it is likely
that you have cold water bleeding into the hot water
side of your water system.
1. Check that valves and faucets are closed when
not in use. If there is an on/off button on your
showerhead, always turn the water valves off after
the shower to prevent cold water from bleeding into
the hot water system. This will keep the heater from
functioning properly.
2. Be sure that the bypass valve at the water plumbing
connections is in the "off" position. An open valve can
also permit water to bypass heater, causing it not to fire.
PrecisionTemp,
Inc.WATER HEATER
LIMITED WARRANTY
PrecisionTemp, Inc warrants to the original owner and subject
to the below mentioned conditions, that this product will be free
of defects in material or workmanship for a period of two years
from the original date of purchase. PrecisionTemp’s liability
hereunder is limited to the replacement of the product, repair of
the product, or replacement of the product with a reconditioned
product at the discretion of the manufacturer. This warranty is
void if the product has been damaged by accident,
unreasonable use, neglect, tampering or other causes not
arising from defects in material workmanship. This warranty
extends to the original owner of the product only and is subject
to the following conditions:
1. For two years from the date of purchase, PrecisionTemp will repair
or replace any part defective in material or workmanship. Some
warranty parts may require a prepay before shipping. Once the
defective part is returned and tested the prepay charge may be
refunded based on findings.
2. This warranty includes labor charges pre-authorized by
PrecisionTemp required to remove and replace the part.
3. Service/Travel calls to the customers location are not considered
part of these charges and are therefore the responsibility of the
owners.
4. This warranty does not cover the following items classified as
normal maintenance:
a. adjustment of gas pressure
b. cleaning or replacement of burner orifices
c. cleaning or adjustment of burner assembly
d. cleaning or adjustment of flue
e. adjustment of pressure relief valve
5. In the event of a warranty claim, the owner must contact, in
advance PrecisionTemp, Inc 800-934-9690 Ext.110.
Return parts (or water heater) must be shipped to PrecisionTemp
“Prepaid”. The defective parts (or water heater) become the
property of PrecisionTemp and must be returned to the Service
Department at PrecisionTemp
6. This warranty applies only if the unit is installed according to the
installation instructions provided and complies with local and state
codes.
7. The warranty period on replacement parts (or water heater) is the
unused portion of the original warranty period or ninety (90) days,
whichever is greater.
8. Damage or failure resulting from misuse (including failure to seek
proper repair service), misapplication, alterations, water damage,
or freezing are the owner’s responsibility.
9. PrecisionTemp does not assume responsibility for any loss of use
of vehicle, loss of time, inconvenience, expense for gasoline,
telephone, travel, lodging, loss or damage to personal property or
revenues. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitations or
exclusions may not apply to you.
10. Any implied warranties are limited to two (2) years. Some
states do not allow limitations on how long an implied warranty
lasts, so the above limitation may not apply to you. This warranty
gives you specific legal rights and you may also have other rights
which vary from state to state.
Replacement parts purchased outside of the original water heater
warranty carry a 90 day warranty.
11. This PrecisionTemp heater is designed for use in recreational
vehicles, park models, tiny homes, mobile food carts and marine
applications for the purpose of heating water as stated in the “data
plate” attached to the water heater. Any other use, unless
authorized in writing by the PrecisionTemp Engineering
Department, voids this warranty.
PrecisionTemp Inc.
3428 Hauck Rd. Ste. G
Cincinnati, OH. 45241
Phone: 513-641-4446 * 800-934-9690 Fax: 513-641-0733
www.precisiontemp.com
11.