COZEBURN INSTALLATION AND OPERATION MANUAL 7
SAFETY
Safety Decals
Please read and follow directions to ensure safe practices when using the Cozeburn furnace.
1) DANGER/WARNING/CAUTION - Located on left hand side of damper.
2) FURNACE SERIAL DECAL - Located on left hand side of furnace.
3) MAX. WOOD FILL TO TOP OF DOOR. - Located on top left hand corner of front door.
4) THIS LID IS HEAVY. USE BOTH HANDS. - Located on back chimney cover.
5) NOTE! MINIMUM 6 FT. OF INSULATED CHIMNEY IS REQUIRED FOR PROPER DRAFT. CLEAN CHIMNEY OUTLET REGULARLY.
COVER CHIMNEY WHEN FURNACE IS NOT IN USE. - Located left of the chimney cover.
6) WIRING DIAGRAM - Located on rear access cover.
7) ELECTRICAL - Located on the right front corner.
8) SPECIFICATIONS - Located on the front left corner.
Electrical Ratings: 120 volts, 60HZ,
max breaker size 15 amps. (Blower
rating is less than 2 amps.)
For supply connections use No.14 AWG
or larger wires acceptable for at least
90ºC (194ºF) or equivalent.
For use with aluminum or copper
conductors.
818651R00
ELECTRICAL
INSTALLATION
ADD-ON INSTALLATION
INSTRUCTIONS
- This furnace can be connected to an
existing boiler system.
- Operate the (oil, gas, electric) boiler
periodically to ensure it will operate
satisfactorily when needed.
- DO NOT relocate or bypass any of
the safety controls in the original
boiler installation.
CAUTION: This equipment may only be
installed by qualied personnel.
- Disconnect electric power to both
boilers before servicing.
An annual inspection by a qualied
service technician is recommended.
INSTALLER INFORMATION:
Name__________________________
Address________________________
_______________________________
Date of Installation_______________
Note!
818645R00
• Minimum5ft.(1.52m)ofinsulated
chimneyisrequiredforproperdraft.
• Cleanchimneyoutletregularly.
• Coverchimneywhenfurnaceisnot
inuse.
RefertoBestBurnPracticesinOperator'sManual.
WARNING
!
THIS LID IS HEAVY.
USE BOTH HANDS.
MAX. WOOD FILL
TO TOP OF DOOR
818643R00
DANGER
!
Risk of re or explosion. DO NOT start or fuel the re using
garbage, gasoline, drain oil or other ammable liquids or
chemicals.
WARNING
!
DOOR AREA MAY BE HOT
SAFE DOOR OPERATION:
Door Opening and Closing Instructions:
1. Switch blower off.
2. Stand back behind door.
3. SLOWLY open door.
4. Wait for smoke to clear (30 seconds).
Close door if smoke continues.
5. Open door fully.
6. After loading, always close and latch door firmly.
7. Switch blower on.
- For safety keep rebox loading door and ash door
tightly closed.
- Follow listed combustible material clearances.
- DO NOT store fuel or other combustible material within
the marked installation clearances of the furnace.
- Inspect and clean ues and chimney regularly.
- Follow complete installation, operating and cleaning
instructions in the Operator’s Manual.
CAUTION
!
-Hot surfaces do not touch.
- KEEP CHILDREN at safe distance.
- DO NOT damage furnace. Load wood carefully.
- DO NOT add fuel during a power outage.
- KEEP water level above the add mark.
- Place ash in metal containers and away from
combustible material.
818647R00
COZEBURN
Outdoor Wood Fired Hydronic Heater/Réchaueur Extérieur De Woodred Hydronic
CERTIFIED HEATING APPLIANCE MODEL NO./CERTIFIÉN DE MODÈLE_______________ APPAREIL DE CHAUFFAGE
CSA STANDARD B366-1-M91 SERIAL NO./N° DE SÉRIE________________________ NORME B366-1-M91 DE LA CSA
UL STANDARD 391, UL 762, UL 2523 NORME 391, 762, 2523 DE ULC
CERTIFIED AS AN ADD-ON MODEL 07/12 CERTIFIÉE COMME MODÈLE COMPLÉMENTAIRE, 07/12
Electrical ratings: volts 120, 1 phase, 60HZ, 15 amps max.
For outdoor use only.
Boiler Fuel - Burn wood only.
Shaker Grate Fuel - Coal or Wood
Use only Flue Pipe that is approved by manufacturer.
Base - Noncombustible, concrete preferred.
Outdoor Wood Fired Hydronic Heater must be kept in good condition, clean
chimney and firebox at end of season. Store wood and all combustible materi-
als outside the installation clearances. Installation clearances: 60” (152 cm)
above/ 48” (122 cm) front/ 6” (15 cm) from sides/ 18” (46 cm) from Flue pipe.
Keep doors closed tightly.
Do not pressurize. Risk of fire or explosion.
Do not connect this unit to a chimney flue serving another appliance.
Load fuel carefully to prevent damage to boiler.
Do not burn garbage, gasoline, naphta or engine oil.
Do not use chemicals or fluids to start fire.
Never run boiler with water level below add mark.
Do not leave door open, or dump ash tray close to any combustible materials,
may lead to runaway fire.
Refer to owner’s manual for complete instructions.
Manufactured by Pro-Fab Industries Inc.
MADE IN USA
Caractéristiques électriques: 120 volts, courant momphasé, 60HZ, max. de
15 ampères.
For outdoor use only.
Combustible - N’utiliser que du bois.
Shaker Grate Fuel - Coal or Wood
N’utiliser qu’un conduit de fumée approuvé par le fabricant.
Base - Utiliser des matériaux incombustibles, de préférence du béton.
Les appareils de chauffage au bois doivent être maintenus en bon état.
Nettoyer le cheminée et la chambre de combustion à la fin de chaque saison.
Entreposer le bois et toutes les matières combustibles suffisamment loin de
l’appareil. Dégagement minimum: 152 cm (60 po) du plafond, 122 cm (18 po)
à l’avant, 15 cm (6po) sur les côtes et 46 cm (18 po) du conduit de fumée.
Garder les portes fermées hermétiquement.
Faites l'aucun pressurisent.
Do not connect this unit to a chimney flue serving another appliance,
Charger soigneusement l’appareil afin de prévenir les dommages.
Ne pas brûler de déchets, de lessence, du napthe ou de l’huile à moteur.
Ne pas utiliser de produits chimiques, solides ou liquides, pour allumer le feu.
Ne jamais faire fonctionner l’appareil si le niveau de l’eau est inferieur au
niveau de sécurité.
Toujours fermer la porte de l’appareil et ne jamais vider un cendrier près de
matières combustibles. Un incendie peut se déclarer très facilement.
Consulter le manuel du propriétaire pour obtenir des instructions complètes.
Fabriqué par Pro-Fab Industries Inc.
FABRIQUÉ AU USA
818640R00
WN00000
1.
3.
2.
5.
4.
COZEBURN
OutdoorWoodFired Hydronic Heater/Réchaueur Extérieur De WoodredHydronic
CERTIFIEDHEATINGAPPLIANCE MODEL NO./CERTIFIÉN DE MODÈLE_______________ APPAREILDECHAUFFAGE
CSASTANDARDB366-1-M91 SERIALNO./N°DE SÉRIE________________________ NORME B366-1-M91 DE LA CSA
ULSTANDARD391, UL 762,UL 2523 NORME391,762, 2523 DE ULC
CERTIFIEDASAN ADD-ON MODEL 07/12 CERTIFIÉECOMMEMODÈLE COMPLÉMENTAIRE, 07/12
Electricalratings:volts 120, 1 phase, 60HZ, 15 amps max.
Foroutdooruse only.
BoilerFuel- Burn wood only.
ShakerGrateFuel- Coal or Wood
UseonlyFlue Pipe that is approved by manufacturer.
Base-Noncombustible, concrete preferred.
OutdoorWood Fired Hydronic Heater must be kept in good condition, clean
chimneyandfirebox at end of season. Store wood and all combustible materi-
alsoutsidethe installation clearances. Installation clearances: 60” (152 cm)
above/48”(122 cm) front/ 6” (15 cm) fromsides/ 18” (46 cm) from Flue pipe.
Keepdoorsclosed tightly.
Donotpressurize. Risk of fire or explosion.
Donotconnect this unit to a chimney flue serving another appliance.
Loadfuelcarefully to prevent damage toboiler.
Donotburn garbage, gasoline, naphta or engine oil.
Donotuse chemicals or fluids to start fire.
Neverrunboiler with water levelbelow add mark.
Donotleave door open, or dump ash tray close to any combustible materials,
mayleadto runawayfire.
Refertoowner’smanual for complete instructions.
ManufacturedbyPro-Fab Industries Inc.
MADEINUSA
Caractéristiquesélectriques:120 volts, courant momphasé, 60HZ, max. de
15ampères.
Foroutdooruse only.
Combustible-N’utiliser que du bois.
ShakerGrateFuel- Coal or Wood
N’utiliserqu’unconduit de fumée approuvé par le fabricant.
Base-Utiliser des matériaux incombustibles, de préférence du béton.
Lesappareils de chauffage au bois doivent être maintenus en bon état.
Nettoyerlecheminée et la chambre de combustion à la fin de chaque saison.
Entreposerlebois et toutes les matières combustibles suffisamment loin de
l’appareil.Dégagementminimum: 152 cm (60 po) du plafond, 122 cm (18 po)
àl’avant,15 cm (6po) sur les côtes et46 cm (18 po) du conduit de fumée.
Garderlesportes fermées hermétiquement.
Faitesl'aucunpressurisent.
Donotconnect this unit to a chimney flue serving another appliance,
Chargersoigneusementl’appareil afin de prévenir les dommages.
Nepasbrûler de déchets, de lessence, du napthe ou de l’huile à moteur.
Nepasutiliser de produits chimiques, solides ou liquides, pour allumer le feu.
Nejamais faire fonctionner l’appareil si le niveau de l’eau est inferieur au
niveaudesécurité.
Toujoursfermerla porte de l’appareil et ne jamais vider un cendrier près de
matièrescombustibles.Un incendie peut se déclarer très facilement.
Consulterlemanuel du propriétaire pour obtenir des instructions complètes.
FabriquéparPro-Fab IndustriesInc.
FABRIQUÉAUUSA
818640R00
WN00000
1
3
2
4
5
7
SPECIFICATIONS
Install and use only in accordance
with the manufacturer’s installation/
operating instructions and local
codes. If there are no applicable local
codes, an outdoor installation chimney
must be listed to the ULC-S610 and
ULC-S604 standard. Flue connector
pipe must be made of a minimum 24
NSG black steel. Refer to authorities
having jurisdiction for proper
installation.
Minimum Clearance to Combustibles
Side Wall to Furnace 6” (15 cm)
Back Wall to Furnace 48” (122 cm)
Front of Furnace to
Combustibles
48” (122 cm)
Top of Furnace 60” (152 cm)
Combustibles to Flue 18” (46 cm)
CAUTION
!
- DO NOT connect the unit to a
chimney ue that serves another
appliance.
- DO NOT burn trash in this furnace.
- DO NOT pressurize water in
furnace.
- DO NOT dump ash close to any
combustible materials.
- The heat exchanger, ue pipe,
chimney must be in good condition
and cleaned regularly to remove
accumulated creosote and ash.
- Clean at the end of the heating
season to minimize corrosion
during summer months.
- Follow cleaning instructions in
Operator’s Manual.
- Refer to Operator’s Manual for
complete instructions.
In the event of loss of electrical power:
1. Open all ow-check and zone
valves in the system. Depending
on system design, this may allow
convective circulation.
2. It is important to remember that
the heating system cannot dispose
of a great deal of heat without
the circulators running. Avoid
over ring! DO NOT LOAD LARGE
AMOUNTS OF SOLID FUEL INTO
THE FURNACE! Fire the furnace
cautiously until it is determined how
quickly the heat system is able to
dissipate the heat being produced
by the furnace.
3. When the power has returned, reset
all ow-check and zone valves and
resume normal operation of the
system.
In the event of a runaway re:
1. Ensure the rebox door is tightly
closed.
2. Close all the combustion air inlets
on the furnace.
To cool an overheated furnace:
1. Turn all thermostats to their highest
temperature setting.
818655R00
8.
7
1
3 2
5
4
6
7
8
9
10
Red
Black Power Line
White Natural Line
Line
Line
Ground
110 Volts AC
1. Love Controller
2. Light Switch
3. Damper Switch
4. Light
5. Probe
6. Snap Disc
7. Circuit Breaker
8. Solenoid
9. Blower
10. Junction Box
818653R00
6.
8
6