protech SI-X208 User manual

USER
MANUAL
SI-Xx08 M1
SI-X208 / SI-X308/
SI-X408 / SI-X608
Industrial EtherCAT Slave
I/O Modules

SI-X208 / SI-X308 /
SI-X408 / SI-X608
Industrial EtherCAT Slave I/O Module
COPYRIGHT NOTICE & TRADEMARK
All trademarks and registered trademarks mentioned herein are the
property of their respective owners.
This manual is copyrighted in May. 2020. You may not reproduce or
transmit in any form or by any means, electronic, or mechanical,
including photocopying and recording.
DISCLAIMER
This user’s manual is meant to assist users in installing and setting up
the system. The information contained in this document is subject to
change without any notice.
CE NOTICE
This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take
adequate measures.

FCC NOTICE
This equipment has been tested and found to comply with the limits for
a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
You are cautioned that any change or modifications to the equipment
not expressly approve by the party responsible for compliance could
void your authority to operate such equipment.
WARNING: Some internal parts of SI-Xx08 may
have high electrical voltage. We strongly recommend
that only qualified engineers are allowed to service
and disassemble SI-Xx08. If any damages should
occur on SI-Xx08 and are caused by unauthorized
servicing, it will not be covered by the product
warranty.

Contents
i
Contents
Revision History ............................................................................................. ii
1SI-Xx08 Introduction ........................................................................... 1-1
1.1 SI-Xx08 Introduction................................................................... 1-2
1.2 Applications ................................................................................ 1-2
1.3 User Manual Structure ............................................................... 1-3
2Getting Started .................................................................................... 2-1
2.1 System Architecture ................................................................... 2-2
2.2 System Overview ....................................................................... 2-3
2.2.1 Six Views ............................................................................ 2-3
2.2.2 Appearance......................................................................... 2-6
2.2.2.1 Front Panel ................................................................... 2-6
2.2.2.2 Top Panel ..................................................................... 2-9
2.3 Specifications ........................................................................... 2-11
2.3.1 SI-Xx08 System Specifications......................................... 2-11
2.3.2 I/O Specifications .............................................................. 2-12
2.3.2.1 SI-X208 I/O Specifications ......................................... 2-12
2.3.2.2 SI-X308 I/O Specifications ......................................... 2-12
2.3.2.3 SI-X408 I/O Specifications ......................................... 2-13
2.3.2.4 SI-X608 I/O Specifications ......................................... 2-13
2.4 Block Diagram ..........................................................................2-14
2.4.1 SI-X208 Block Diagram .................................................... 2-14
2.4.2 SI-X308 Block Diagram ....................................................2-15
2.4.3 SI-X408 Block Diagram ....................................................2-16
2.4.4 SI-X608 Block Diagram ....................................................2-17
2.5 Quick Start................................................................................ 2-18

Contents
SI-Xx08 SERIES USER MANUAL
Page: ii
2.6 Configuration and Operation ....................................................2-19
2.6.1 SI-X208 ............................................................................. 2-20
2.6.1.1 EEPROM Update .......................................................2-20
2.6.1.2 ESI File Rule .............................................................. 2-26
2.6.1.3 Index Ranges ............................................................. 2-29
2.6.1.4 System Topology ........................................................ 2-29
2.6.2 SI-X308 ............................................................................. 2-30
2.6.2.1 EEPROM Update .......................................................2-30
2.6.2.2 ESI File Rule .............................................................. 2-35
2.6.2.3 Index Ranges ............................................................. 2-38
2.6.2.4 System Topology ........................................................ 2-38
2.6.3 SI-X408 ............................................................................. 2-39
2.6.3.1 EEPROM Update .......................................................2-39
2.6.3.2 ESI File Rule .............................................................. 2-44
2.6.3.3 Index Ranges ............................................................. 2-48
2.6.3.4 System Topology ........................................................ 2-48
2.6.4 SI-X608 ............................................................................. 2-49
2.6.4.1 Scan Device ............................................................... 2-49
2.6.4.2 Import PLC Code........................................................2-53
2.6.4.3 GUI ............................................................................. 2-56
2.6.4.4 PLC Code POU Description.......................................2-59
2.7 Safety Precautions ................................................................... 2-60
3Hardware Configuration ..................................................................... 3-1
3.1 SI-X208 Pin Assignment ............................................................ 3-2
3.2 SI-X308 Pin Assignment ............................................................ 3-3
3.3 SI-X408 Pin Assignment ............................................................ 3-4

Contents
iii
3.4 SI-X608 Pin Assignment ............................................................ 3-5
3.5 I/O Connections ......................................................................... 3-6
3.5.1 Isolated Digital Input Connections ...................................... 3-6
3.5.2 Isolated Digital Output Connections ................................... 3-8
3.5.3 Isolated Analog Input Connections ..................................... 3-9
3.6 Installing DIN-Rail Mount ......................................................... 3-10
3.7Technical Support..................................................................... 3-11

Revision History
SI-Xx08 SERIES USER MANUAL
Page: ii
Revision History
The revision history of SI-Xx08 User Manual is described below:
Version No.
Revision History
Date
M1
Initial Release
2020/05/11

SI-Xx08 SERIES USER MANUAL
Page: 1-1
1 SI-Xx08 Introduction
This chapter provides the introduction for SI-X208,
SI-X308, SI-X408 and SI-608 modules, applications list as
well as the framework of the user manual.
The following topics are included:
•SI-Xx08 Introduction
•Applications
•User Manual Structure

Chapter 1 Introduction
SI-Xx08 SERIES USER MANUAL
Page: 1-2
1.1 SI-Xx08 Introduction
Thank you for purchasing our SI-Xx08 Industrial EtherCAT Slave I/O
Modules which supports EtherCAT protocol. EtherCAT (Ethernet Control
Automation Technology) which is developed by BECKHOFF Automation is
a high-performance Ethernet-based fieldbus industrial network system. This
protocol which is standardized in IEC standard IEC61558 is suitable for
real-time automation applications.
All EtherCAT Slave I/O Modules can be connected by the network topologies
such as star, line, or ring. Our SI-Xx08 I/O modules are installed by daisy
chain connection which has the flexibility in devices installation and reduces
the costs of infrastructure and operations. For the power requirements, the
SI-Xx08 modules are designed for standard industrial unregulated 24 VDC
Power input. However, they accept any power unit that supplies power within
the range of +9 to +48 VDC. All the I/O modules have the isolated input and
output design which protects SI-Xx08 I/O modules against external
interference and environment. The EtherCAT Slave Controller has passed and
has been verified by the conformance test tool. The qualified EtherCAT
Master can connect with SI-Xx08 modules easily and can be applied for
various applications.
1.2 Applications
Factory Automation
Machine Automation
Machine Tooling
Data Acquisition

Chapter 1 Introduction
SI-Xx08 SERIES USER MANUAL
Page: 1-3
1.3 User Manual Structure
Chapter 1 Introduction
This chapter gives the brief introduction of SI-Xx08, applications list as well
as the framework of this user manual.
Chapter 2 Getting Started
This chapter describes the system architecture, system and I/O specifications,
illustrates the physical appearances, block diagrams, quick installation guide
as well as configuration and operation. Read the safety reminders carefully on
how to take care of SI-Xx08 properly.
Chapter 3 Hardware Configuration
This chapter describes the information of pin assignment, wire connection and
DIN-Rail mount installation.

SI-Xx08 SERIES USER MANUAL
Page: 2-1
2 Getting Started
This chapter describes the system architecture, system and I/O
specifications, illustrates the physical appearances, block
diagrams, quick installation guide as well as configuration and
operation. Read the safety reminders carefully on how to take
care of SI-Xx08 properly.
The following topics are included:
•System Architecture
•System Overview
•Appearance: Front Panel & Top Panel
•System and I/O Specifications
•Quick Start
•Configuration and Operation
•Safety Precautions

Chapter 2 Getting Started
SI-Xx08 SERIES USER MANUAL
Page: 2-2
2.1 System Architecture
The System Architecture diagram is shown as below:

Chapter 2 Getting Started
SI-Xx08 SERIES USER MANUAL
Page: 2-3
2.2 System Overview
2.2.1 Six Views
Unit: mm
Unit: mmUnit: mm
X208 rF-IS ont View SI-X308 Front View
33
139.67
7.41
SI-X208
EC1
DI8
DI9
DI10
DI11
DI12
DI13
DI14
DI15
DRY
System Status
Indicators
I/O Status
Indicators
I/O Terminal
Block
EC0
DI0
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DRY
PWR RUN ERR
LINK/ACT
IN OUT
DI 0 1 2 3
4 5 6 7
8 9 10 11
12 13 14 15
33
SI-X308
PWR RUN ERR
LINK/ACT
IN OUT
DI
DO
0 1 2 3
4 5 6 7
0 1 2 3
4 5 6 7
PC0
DO0
DO1
DO2
DO3
DO4
DO5
DO6
DO7
GND
EC0
DI0
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DRY
139.67
7.41
System Status
Indicators
I/O Status
Indicators
I/O Terminal
Block
SI-X408 Front View SI-X608 Front View
33
139.67
7.41
SI-X408
PC1
DO8
DO9
DO10
DO11
DO12
DO13
DO14
DO15
GND
PC0
DO0
DO1
DO2
DO3
DO4
DO5
DO6
DO7
GND
PWR RUN ERR
LINK/ACT
IN OUT
DO 0 1 2 3
4 5 6 7
8 9 10 11
12 13 14 15
33
139.67
7.41
PWR RUN ERR
LINK/ACT
IN OUT
SI-X608
V0-
V1-
V2-
V3-
V4-
V5-
V6-
V7-
AGND
AGND
V0+
V1+
V2+
V3+
V4+
V5+
V6+
V7+
AGND
AGND
System Status
Indicators
I/O Terminal
Block
System Status
Indicators
I/O Status
Indicators
I/O Terminal
Block

Chapter 2 Getting Started
SI-Xx08 SERIES USER MANUAL
Page: 2-4
SI-Xx08 Rear View
SI-Xx08 Top View
SI-Xx08 Bottom View
Notes:
1. It is recommended connecting FGND PIN to functional earth via a cable.
2. DO NOT connect GND PIN and FGND PIN of the terminal block together
as they might have potential differences which might cause signal interferences.
116.38 EtherCAT Ports
+VS GND FGND OUT IN +VS GND FGND
DC In

Chapter 2 Getting Started
SI-Xx08 SERIES USER MANUAL
Page: 2-5
SI-Xx08 Left Side View
SI-Xx08 Right Side View
35.22

Chapter 2 Getting Started
SI-Xx08 SERIES USER MANUAL
Page: 2-6
2.2.2 Appearance
The front panel and top panel of the SI-Xx08 module contain the I/O connector, LED
Indicators, Ethernet Port and power connector.
2.2.2.1 Front Panel
Taken as an example, the following picture displays the SI-X308 front panel and
indicates the locations of LED indicators and I/O connector.
1. LED Indicator
2. I/O Connector

Chapter 2 Getting Started
SI-Xx08 SERIES USER MANUAL
Page: 2-7
1. LED Indicator Type
•PWR LED: After power is supplied to the SI-Xx08 EtherCAT Slave I/O
module, the “PWR” LED indicator will illuminate.
Indicator State
Module State
Description
Off
Power Off
System Power is OFF.
On
Power On
System Power is ON.
•RUN LED: The “RUN” LED indicates the operation state of the SI-Xx08
EtherCAT Slave I/O Module.
Indicator State
System State
Description
OFF Initialization
The device is in the Initialization
state.
Blinking Pre-Operational
The device is in the
Pre-Operational state.
Single Flash Safe Operational
The device is in the Safe
Operational state.
On Operational
The device is in the Operational
state.
•ERR LED
Indicator State
System State
Description
Off No Error
No Error. The device is in normal
operation state.
Blinking
Invalid
Configuration
Configuration error.

Chapter 2 Getting Started
SI-Xx08 SERIES USER MANUAL
Page: 2-8
•LINK/ACT (IN/OUT) LED: EtherCAT Link State.
Indicator State
System State
Description
Off
No Link
No EtherCAT connection.
Blinking
Activity
EtherCAT link and activity.
On
Without Activity
EtherCAT link without activity
•I/O LED (Only for SI-X208/SI-X308/SI-X408)
Indicator State
System State
Description
OFF
No Activity
I/O channel is in active state.
ON
Activity
I/O channel is not in active state.
2. I/O Connector
Please refer to Section 3.1 to Section 3.4 SI-Xx08 Pin Assignment for more
information about the pin assignments for I/O connector.

Chapter 2 Getting Started
SI-Xx08 SERIES USER MANUAL
Page: 2-9
2.2.2.2 Top Panel
1. DC Power-In Interface
The “+VS” and “GND” pins are used for the power supply and apply to all types of
SI-Xx08 EtherCAT I/O modules. The valid power voltage range is from +9 to +48 VDC.
The “FGND” is Frame Ground. The SI-Xx08 module device can be connected to the
building structure which is connected to the functional earth. With this architecture, the
same reference potential can be provided to all EtherCAT I/O modules. Please see the
picture below:
2. EtherCAT Interface2. EtherCAT Interface
1. DC Power-In1. DC Power-In Interface
connected to earth

Chapter 2 Getting Started
SI-Xx08 SERIES USER MANUAL
Page: 2-10
2. EtherCAT Interface
SI-Xx08 EtherCAT Slave I/O modules are equipped with two RJ45 EtherCAT Interface
ports. One is “IN” port which is EtherCAT signal input port that connects to EtherCAT
Master or the EtherCAT signal output port of previous EtherCAT Slave I/O Module. The
other is “OUT” port which is EtherCAT Signal output that connects to the EtherCAT
signal input port of next EtherCAT Slave I/O Module.
This manual suits for next models
3
Table of contents
Other protech I/O System manuals
Popular I/O System manuals by other brands

NI
NI PXIe-7821R Getting started guide

National Instruments
National Instruments SCXI quick start guide

Magnetek
Magnetek SMART TRAC DM6420 Engineer's guide

Diamond technologies
Diamond technologies DT7000 user guide

National Instruments
National Instruments NI USB-6008 quick start

CREVIS
CREVIS FnIO G-Series user manual