Reison 10-380 User manual

1
Armboard 10-380 including versions
Version
Description
10-380
10 mm spacer, clamp (EU 25x10 mm rail) and curved plate
10-380-UK
10 mm spacer, clamp (UK 1¼ ” x ¼ ” rail) and curved plate
10-380-US
10 mm spacer, clamp (US 1⅛ ’’ x ⅜ ’’ rail) and curved plate
10-380-K
10 mm spacer, clamp (EU 25x10 mm rail) and short curved plate
10-380-UK-K
10 mm spacer, clamp (UK 1¼ ” x ¼ ” rail) and short curved plate
10-380-K-US
10 mm spacer, clamp (US 1⅛ ’’ x ⅜ ’’ rail) and short curved plate
10-380-F
10 mm spacer, adapted clamp (EU 25x10 mm rail) and curved plate
10-380-F-US
10 mm spacer, adapted clamp (US 1⅛ ’’ x ⅜ ’’ rail) and curved plate
10-380-L
10 mm spacer, clamp (EU 25x10 mm rail) and curved plate, long post
10-380-L-UK
10 mm spacer, clamp (UK 1¼ ” x ¼ ” rail) and curved plate, long post
10-380-L-US
10 mm spacer, clamp (US 1⅛ ’’ x ⅜ ’’ rail) and curved plate, long post
10-380-M
30 mm spacer, clamp (EU 25x10 mm rail) and flat plate
10-380-M-UK
30 mm spacer, clamp (UK 1¼ ” x ¼ ” rail) and flat plate
10-380-M-US
30 mm spacer, clamp (US 1⅛ ’’ x ⅜ ’’ rail) and flat plate
10-380-M10
10 mm spacer, clamp (EU 25x10 mm rail) and flat plate
10-380-S30
30 mm spacer, clamp (EU 25x10 mm rail) and curved plate
Warning! This symbol indicates important information related to safety. Follow these
instructions carefully.
Read User Manual before use! It is important to fully understand the content of the user
manual before attempting to use the equipment.
2021-11-30
Document number: M10-380EN rev.02
Armboard 10-380
ENGLISH

2
Intended use
Armboard intended for placing and positioning the patients arm for e.g. medication during surgery.
The product is to be used by medical professionals within a medical facility.
Safety regulations
Maximum load: 12 kg in even distribution, corresponding to a patient weight of 200 kg, according to
EN 60601-1 and EN 60601-2.
Before use, ensure correct function!
When loosening the lock lever to adjust the height, support underneath the armboard, to prevent it
from uncontrolled descend into the bottom position.
Remove the armboard or secure it over the operating table, during transport!
For use during diathermy procedures, the cushion must be fixed to the plate by using e.g. Velcro straps,
to prevent from sliding. The complete device needs to be covered with e.g. sterile bag, to prevent the
patient to come in contact with the metal parts.
Service and preventive maintenance shall be performed by authorized personnel.
MAX 12 kg (MAX 200 kg )

3
User instructions
Installation
Position adjustment
B.
1.
2.
90o
A.
B.
A.
A.
B.

4
Maintenance
Do not place in dishwasher! The lock mechanism will be destroyed by corrosion in the ball joint. For
cleaning instruction, please, read “Cleaning” in this manual.
Service, preventive maintenance, adjustment and repair shall be performed by authorized personnel
only. Altering the construction without a written consent from the manufacturer, is strictly forbidden.
Adjusting the lock mechanism
Tool: 3 mm hex key.
To turn 1/8 of a round is enough for adjustment.
Complete lock should be achieved when the lever is at rest.
Too strong lock may lead to damage in case of e.g. collision.
Adjusting the lever position
Tool: 3 mm hex key.
Weaker lock
Stronger lock
A.
B.
C.

5
Cleaning
Clean with antiseptic detergent with pH 6 –8 and warm water. Ethanol can be used. Wipe dry with
soft cloth. Do not use strong acidic or alkaline detergent.
To avoid malfunction do not use detergents in the ball joint! The oil film in the ball joint shall not be
removed. Damp a soft cloth with antiseptic detergents or alcohol to clean the ball joint. Wipe it dry.
The ball joint device shall be oiled with hydraulic oil ISO VG32 or similar.
Control
Check that there are no loose parts and that there is no damage to any part. The lock function is
checked by locking and unlocking the top in different positions. If a cushion is used check that it is clean
and is not damaged.
Annual service
Once a year the arm board shall be carefully cleaned, moving parts shall be lubricated, the locking
function shall be tested and, if necessary, the ball joint shall be adjusted.

6
Spare parts
Version:
10-380
10-380-K
10-380-F
10-380-L
10-380-M
10-380-M10
10-380-S30
Description
Pcs.
Article no.
Article no.
Article no.
Article no.
Article no.
Article no.
Article no.
1.
Plate
1
10020
10514
10020
10020
10050
10050
10020
2.
Ball joint locking device
1
10021
10518
10021
10021-L
10021
10021
10021
3.
Screw MFX-Z A4-70
M4x10
4
-
-
-
-
-
-
-
4.
Clamp body
1
EU:10031
US:10547
UK:10543
EU:10031
US:10547
UK:10543
EU:10031
US:10547
EU:10031
US:10547
UK:10543
EU:10031
US:10547
UK:10543
10031
10031
5.
Washer
1
10004
10004
10004
10004
10004
10004
10004
6.
Screw MF6S M&x12 A2
1
-
-
-
-
-
-
-
7.
Spacer
1
10526-A
10526-A
10526-A
10526-A
10526-30
10526-A
10526-30
8.
Guide
2
10053
10053
10212
10053
10053
10053
10053
9.
Screw MC6S M6x45 FZ
1
-
-
-
-
-
-
-
10.
Shaft
1
10009
10009
10009
10009
10009
10009
10009
11.
Spring
1
10013
10013
10013
10013
10013
10013
10013
12.
Pressure pin
1
10012
10012
10012
10012
10012
10012
10012
13.
Plunger
1
10711
10711
10711
10711
10711
10711
10711
14.
Eccentric
1
11165
11165
11165
11165
11165
11165
11165
15.
Lock lever
1
10014
10014
10014
10014
10014
10014
10014
16.
Ball
1
K20M8S
K20M8S
K20M8S
K20M8S
K20M8S
K20M8S
K20M8S
17.
Adjustable lock lever
1
6-593-65
6-593-65
6-593-65
6-593-65
6-593-65
6-593-65
6-593-65

7
Accessories
Armboard:
10-380
10-380-K
10-380-F
10-380-L
10-380-M
10-380-M10
10-380-S30
Article no.
Description
10-181
Flat comfort cushion
x
x
10-182
U-shaped comfort cushion
x
x
10-381
Flat moulded cushion
x
x
x
x
10-382
U-shaped moulded cushion
x
x
x
x
10-382-H
U-shaped comfort cushion
45 mm
x
x
x
x
10-382-HT
U-shaped comfort cushion
70 mm
x
x
x
x
10-382-K
U-shaped comfort cushion
short
x
10-383
Armboard strap
x
x
x
x
x
x
x
10-383-L
Armboard strap long
x
x
x
x
x
x
x
Technical specification
Maximum work load
12 kg in even distribution, corresponding to a patient weight of 200 kg,
according to EN 60601-1 and EN 60601-2
Weight
4,3 kg
Material armboard
Stainless steel
Version
UDI-DI
Dimension
(H x W x L)
10-380
07350111830359
220 x 180 x 670 mm
10-380-UK
07350111830540
220 x 180 x 670 mm
10-380-US
07350111830557
220 x 180 x 670 mm
10-380-K
07350111830397
220 x 180 x 520 mm
10-380-UK-K
07350111830366
220 x 180 x 520 mm
10-380-K-US
07350111830441
220 x 180 x 520 mm
10-380-F
07350111832827
220 x 180 x 670 mm
10-380-F-US
07350111832834
220 x 180 x 670 mm
10-380-L
07350111830458
400 x 180 x 670 mm
10-380-L-UK
07350111830465
400 x 180 x 670 mm
10-380-L-US
07350111830472
400 x 180 x 670 mm
10-380-M
07350111830489
220 x 180 x 670 mm
10-380-M-UK
07350111830502
220 x 180 x 670 mm
10-380-M-US
07350111830519
220 x 180 x 670 mm
10-380-M10
07350111830496
220 x 180 x 670 mm
10-380-S30
07350111830526
220 x 180 x 670 mm
This manual suits for next models
15
Table of contents
Other Reison Rack & Stand manuals
Popular Rack & Stand manuals by other brands

SmartMetals
SmartMetals BalanceBox 400 Series manual

B-Tech
B-Tech BTF844 Installation guide & parts list

New Star
New Star NeoMounts NM-HUB2LIFTBLACK instruction manual

PMV Mounts
PMV Mounts PMVTROLLEYXXL Assembly instructions

Security +
Security + 292 897 01 quick start guide

Oriental motor
Oriental motor LAS Series operating manual