Remedies RM001 User manual

Humidifier

Introductions Page 3
Features Page 4
Safety Precautions Page 5
Operating Precautions Page 6
Notes Page 7
Know your Rainbow Mist Page 8
Choosing a Suitable Location Page 9
Filling Instructions Page 10
Operating Instructions Page 12
Controlling the LED Night Light Page 13
Caring for your Rainbow Mist Page 14
Technical Specications Page 16
Troubleshooting Page 17
Contact us Page 18
2
Index
It is essential to use the Remedies humidier Rainbow Mist in the way it
was intended. You are therefore advised to read this instruction manual
and the safety precautions carefully before use.
Utilising the Remedies Rainbow Mist in any way other than depicted in this
manual may void the warranty of your unit.
The Remedies Rainbow Mist is an Ultrasonic humidier. An ultrasonic
humidier atomises water into ultra-ne particles of 1-5um using the
principle of ultrasonic high-frequency oscillation, and diuses the cool
water vapor into the air through a pneumatic device to serve the purpose
of even air humidication.
The ultrasonic technology is a well established technology that has been
widely applied to dierent elds.
3
Introduction

5
1. The Remedies Rainbow Mist is specically designed to humidify the
air with cold vapor using ultrasonic high frequency oscillation.
2. The Rainbow Mist features a Seven Color LED night light.The light can
be set to cycle through all seven colors or set to your favourite color.
3. The Rainbow Mist’s adjustable vapor ow puts you in control of your
environment’s humidication.
4. The Aromatic Diuser allows you to diuse your favourite oil or water
based aroma.
5. The silent operation will ensure your loved ones get the best night
sleep possible.
6. The Rainbow Mist will give you 8 hours of continuous use if run at
maximum ow rate. If running at low ow rate, the Rainbow Mist will
give you up to 12 hours of use.
7. The Rainbow Mist’s two year replacement warranty will give you
great peace of mind.
4
Features
1. Do not replace the power cord without authorization. This appliance is not
intended for use by persons (including children) with reduced physical,
sensory or mental capabilities.
2. Do not plug into the power with a wet hand; otherwise there might be the
risk of electric shock.
3. When the body is inclined, please handle this with the power cut o.
4. Do not touch the Oscillator upon starting; it will cause you to feel pain.
5. Do not disassemble the unit without cutting o the power to avoid an
electric shock.
6. Do not dismantle the main base for repair or debugging by yourself.
7. Do not replace the power cord by yourself.
8. Keep any harmful liquids, such as cleaning agent, away from reach of
children to avoid entering the unit by mistake.
9. Any modication or retting to this unit without denite permission of our
factory may cause damage to the humidier and hazard to the user.
10. If the unit generates any abnormal sound or odour during operation,
please shut it down immediately and disconnect the power plug.
11. Any repair must be done by an authorised repairman.
12. Before cleaning or moving the unit, please shut it down or disconnect the
power plug.
13. Do not operate the unit with an empty water tank.
14. Do not scratch the ultrasonic oscillator with a hard object.
15. Do not let water ow or splash into the base to avoid damaging the
internal parts.
16. Put the unit at a rm and at place, avoid inclination and keep it steady.
17. Place the unit away from any heat source, such as a furnace, avoid direct
sunlight.
18. Avoid direct spraying of mist onto the furniture and electric appliances,
19. Place the unit in normal room temperatures. Avoid operating the unit in
chilly environments to avoid damage to the unit. If there is freezing inside,
do not start unit until the ice has been cleared or melted.
Safety Precautions

7
1. Do not add hot water of over 45°C to the water tank and to avoid
discoloration or distortion.
2. When the room temperature is below 0°C, please empty the water
tank and water bowl. Icing of water can damage the components.
3. Do not place metals, chemicals and detergents into the water tank.
4. Do not put the aroma oil directly into the water tank or the water
bowl of the humidier.
5. When there is excess water in the water bowl, do not move it about
to avoid overow problems.
6. Keep the Rainbow Mist away from moisture sensitive furniture and
electric appliances.
7. Do not add water into the water bowl directly.
8. When the unit is not to be used for a long time, please unplug from
the power point.
9. Never pour out the water remaining in the water bowl without the
power turned o.
10. When the water tank is full, the unit can operate for 8 hours at
maximum fow rate.
6
Operating Precautions Notes

8 9
Do not direct the Rainbow Mist vapor ow at walls or furniture which is
sensitive to moisture. Please adjust the vapor ow to the required comfort
level and to suit the size of the room.
More than 5 feet
from the ceiling
More than 2
feet from the
wall
More than 2
feet from the
wall
More than 2 feet
from the oor
Caution
Know your Rainbow Mist Humidier
Vapor
Nozzle
Water
tank
Oscillator
Color LED
switch
Power /
Vapor ow
adjustment
knob
Power cord
power plug
Aroma
diusion
sponge
Aroma
diusion
tray
Power
indication light
Water Filter
Color
LED lamp
water valve
Vapor
outlet
water bowl
Choosing a suitable location

11
4. Fill the tank with clean water at room temperature.
5. Screw the cap and lter, wipe o excess water drops
around the water tank.
5.Put the water tank back on the base. Secure the nozzle
on the water tank.
10
Filling Instructions
1. Remove the vapor nozzle from the water tank
2. Invert the water tank and turn the lter cap counter-
clockwise
3. Remove the cap and the attached lter.
It is highly recommended that the lter be replaced after
approximately 500 hours of operation.

13
Controlling the LED Night Light
LED ON/OFF
Button
1. The Rainbow Mist night light, lights
up when you press LED ON/OFF button.
The LED lights will change as per cycle
shown below.
OFF Auto cycle 7 colors Purple Indigo
Blue
GreenYellowOrange
Red
1. Remove the Aroma diusion tray in the rear. Simply hold the tray, lift
and pull out.
2. Soak the Aroma diusion sponge with your favourite oil or water
based aroma.
3. Replace the Aroma diusion tray.
4. Turn on the Rainbow Mist humidier and enjoy the aroma.
Using the Aroma Diuser
12
Operating Instructions
1. Turn the main control knob clockwise.
The power indicator lights up green and
humidication begins.
2. Adjust the humidication level by turning
power / humidication control knob. The
humidication, vapor level increases by turning
the knob clockwise.
3. When the LED ashes Red, the water level is
low. Humidication will stop. Please turn o the
power and unplug from the main power supply.
Rell water tank as per previous instructions.
4. To stop the humidication, turn the main
vapor control knob counter clockwise until a
click is heard, the switch is now o. The LED light
also turns o.

14 15
Caution
If using a commercially available
cleaning agent, please ensure to
follow the exact manufacturer
instructions.
Cleaning the water tank
1. Remove the nozzle and water
tank
2. Remove the lter cap.
3. Clean the tank with a diluted
vinegar solution.
4. Rinse extremely well, taking
care not to leave any cleaning
residue in the tank.
5. Dry thouroughly.
6. Store in original packaging if
not used for extended period
of time.
Caring for your Rainbow Mist Humidier
Caring for the Body
1. Remove the nozzle and water tank
2. Using a clean cloth, wipe accumulating
dirt and excess water from the bowl top.
Before caring or cleaning your humidifyier, please switch o the power and
unplug from the mains power.
Caution
Caring for the oscillator
1. Remove the nozzle and water tank
2. Wipe o the excess water from the
humidier bowl.
3. With a soft toothbrush, clean the metal
surface of the oscillator
4. Rinse well with fresh water.
5. Dry Thouroughly
Oscillator

If you have problems while using your Rainbow Mist humidier, please refer to this guide
to help resolve the problem. If the problem persists, please contact our customer service
Problem Advice
Power does not turn on The power cord is disconnected. Plug in to
main power supply.
• The humidier does not work.
• The humidier does not blow out
enough vapor.
• There is not enough water in the water
tank. Rell the water tank
• Ensure the humidier is placed on a
level horizontal surface, and the tank is
installed correctly.
• Ensure the variable control knob is on
the correct setting.
• Ensure there is no dust or mineral build
up on the oscillator
• Ensure the oat is functioning properly
• If no vapor is produced, ensure the
oscillator is not damaged
• The vapor smells • The humidier bowl and oscillator may
be dirty. Clean the oscillator and bowl
as per instructions.
• Change old water and replace with
fresh clean water
• There is a water leak • The water tank, lter cap is loose.
Please tighten
• The water tank may not be
inserted correctly, reinsert
properly
17
Troubleshooting
16
Technical Specications
Problem Advice
Model name Rainbow Mist - RM001
Rated voltage 100-240V 50/60Hz
Power consumption 22 W
Maximum jet ow 280 ml / hr
Water tank capacity 2.8 Litres
Continuous use time Approximately 8-10 hours at maximum
ow rate
External dimensions 200 (W) x 207 (D) x 291 (H) mm
Weight 0.98 Kg
Country of Manufacture China

For customer inquires please write to:
Info@remediessurgical.com or call 718.599.5301
The manufacturer reserves the right to alter the
specications of the product without prior notication.
Copyright © 2010 TLC Diagnostics All Rights Reserved.
Remedies, a product of TLC Diagnostics.
Humidifier
Table of contents
Popular Humidifier manuals by other brands

Holmes
Holmes HCM3955 owner's guide

Skuttle Indoor Air Quality Products
Skuttle Indoor Air Quality Products 2101 Replacement parts

pureguardian
pureguardian H920BL Use & care instructions

HoMedics
HoMedics UHE-CM180 Instruction manual and warranty information

Aprilaire
Aprilaire 800 Series Maintenance Instruction

HygroMatik
HygroMatik Basic manual

Sunbeam
Sunbeam SCM3502-CN Instruction leaflet

Sharp
Sharp HV-50CXE Operation manual

Guardian
Guardian H920 Use & care instructions

Crane
Crane EE-5200W instruction manual

Essick
Essick ED11 800 Care and use manual

Skuttle Indoor Air Quality Products
Skuttle Indoor Air Quality Products 2000 installation instructions