SANJOSE Technology NB-5 User manual

1
Tracking Solutions
Embedded Antenna design
GPS&Wireless solutions Provider
Part Number: NB-5
Doc Type : User Manual
Doc Id: WI-RD-E-054
Reversion : V1.0
Copyright © 2020 San Jose Technology, Inc. All Rights Reserved.
This document contains information that is the property of SANAV. This document may
not be copied, reproduced, reduced to any electronic medium or machine readable form,
or otherwise duplicated, and the information herein may not be used, disseminated or
otherwise disclosed, except with the prior written consent of SANAV.

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
2
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
Contents
Specifications ................................................................................................................3
NB5 Function Overview...........................................................................................4
NB5 Tracker Installation ........................................................................................8
Cutting Tools................................................................................................................12
NB5 SMS Command Quick Setting ..................................................................15
STEP 1: Set up Username/Password (Optional) .......................................17
STEP 2: Set up Phone Book and Security Phone Number (Optional)19
STEP 3: Set up HA ID..........................................................................................20
SETP 4: Set up RF Detection (Optional) ......................................................21
SETP 5: Set up RF Power ...................................................................................22
STEP 6: Set up APN for 3G Service ...............................................................23
STEP 7: Set up URL and TCP/UDP IP Address...........................................24
STEP 8: Set up Route for Data Transmission.............................................26
STEP 9: Set up Auto Report (Optional) ........................................................27
Step 10: Request IMEI Number ......................................................................28
Appendix 1: Report Data Format.....................................................................29
Appendix 2: Tracker Event List.........................................................................31
SMS Command Introduction...............................................................................32
How to Use ER Command for erase the flash ..........................................33
How to Restart The Device..................................................................................34
Setting of Restart The Device............................................................................35
Use POll Command for acquiring the position.........................................36
Set up FBR Command for Fiber Strap ...........................................................37
Use REED Command for Cover Tamper........................................................38
Command for Toggling the Buzzer and vibrator ....................................39
Power Saving Mode Setup ...................................................................................41
AES128 encryption function setting ..............................................................42
TCP acknowledge function setting .................................................................43
Set up Low Power reminder ...............................................................................44
GSM Cell Information Setting ............................................................................45
Firmware upgrade Over The Air (FOTA) function .................................46

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
3
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
Specifications
GSM
GSM Module:
uBlox SARA U201
GSM Frequency:
3G: 800/ 850/ 900/ 1900/ 2100MHz
GSM: 850 / 900/ 1800/ 1900MHz
3G Transmission:
Power class 3 (24 dBm) for WCDMA/HSDPA/HSUPA mode
GPS
GPS Module:
u-blox G8030 support NMEA0183
Sensitivity:
-164 dBm
Channels/ Frequency:
72 Channels/ GPS/QZSS/GLONASS
TTFT(Hot/Warm/Cold):
Cold/Warm <26 seconds
Hot <1 second
Position Accuracy:
2.5 meter (CEP, 50%, 24 hours static, -130dBm, SEP: <3.5m)
RF
RF Module:
RIFO TI CC1101/ Modulation: FSK
Frequency:
436.8MHz
Sensitivity:
-116dBm/0.6kbaud
System
Control system
Alarm/ RF/ GSM
Antenna type:
Embedded GPS/ GSM/ RF antenna
Power
External Power Output:
DC 9V/ 2A/ 18W (Standard)
Battery Power:
3.7V DC Li-Ion Battery, 2300mAh
Battery life:
Charge 3 hours battery to support the device to operate more
than 30 hours
(based on 1 report/1 minutes, No alarm)
Environment Condition
Charging temperature:
0°C ~ +40°C
Working/Storage
temperature:
-10°C ~ +55°C
Relative Humidity:
5% ~ 95%, non-condensing
Mechanics Data
Size:
80mm (L) x 68mm (W) x 42mm (H)
Strap Size:
375mm (L) x 30mm (W) x 4.5mm (T)
Weight:
200g (Including strap and batteries)

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
4
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
Waterproof:
IP68
NB5 Function Overview
1. Basic Function Introduction
NB5 is multi-functional electronic monitoring ankle bracelet with GPS/3G/RF monitoring technology. With
electronic monitoring technology, you have ability to reliability track user’s location. NB5 utilizes GPS and 3G
services to upload the RMC sentences containing latitude, longitude, date and time to assigned monitoring
center. It is specially designed for the intensive tracking applications, such as offender tracking or life security.
Note: In the house, please install remote monitoring unit and signal amplifier to enhance signal strength if
necessary. Remote monitoring unit monitors user’s movement and an alarm is automatically sent to assigned
monitoring center if the user violates the regulations.
2. Main features
Built-in buzz and vibration alarm
Support low battery / strap cut / equipment case opened
Reusable and adjustable fiber optical strap
Entering/leaving restriction zoom alarm
IP68 waterproof
Weak signal alarm
100% charge/charging/ low-charge LED indication ; Power status of NB5 reports to remote
monitoring unit

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
5
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
Charge 3 hours to provide above 30-hour operation (each report/1 minutes, no general alarm)
3. Front View
LED (from left to right):
1. GPS Positioning LED (Blue):
While the device gets GPS fixed, the GPS light will stay on.
2. GSM LED (Red):
While the device gets GSM fixed or in normal operation, the GSM light will flash every 3 seconds.
In case of weak GPS signal, the GSM LED will flash every second.
When GSM enter the power-saving mode, the GSM light will stay off.
3. Status LED (Orange):
While the device is sending the reports or SMS message, the Status LED will flash one time. In case the
device is at low battery, the LED will flash every second. If an alarm has occurred, the Status LED will be
quick flash.
4. CH charge LED (Green):
While the device connects to the charger, the CH LED will flash every second. Once the device is fully
GPS
GSM
STATUS
CH

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
6
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
charged, the CH LED will stay on. Unplug the charger when the device is fully charged. In this situation,
CH charger LED will be off.
5. Charge Socket (Red circle):
Please make sure to use San Jose original charger and charging pack to protect your equipment.

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
7
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
4. Back Cover
5. Wall Charger

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
8
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
NB5 Tracker Installation
Note: The device must be fully charged prior to installation. Remember to wear a pair of socks for comfortable
attaching.
1. Circle the user’s leg with strap and
installation height of NB5 will be 8-10cm
from an outer ankle.
2. Circle the user’s leg with strap and
determine the length of the strap that
leaves approximately 20-30 mm (2-3
scales) of space between the use’s leg
and the strap for comfortable to wear.
3. For example, Back Cover Edge Line is at
the block 14; you should cut the block 16
which is spare space for the strap clip.
4. Use the specific cutting tool to cut the
strap not the scissors.
Please refer to the document of cutting
tool below.
Use the dedicated strap cutter to cut the
strap to corresponded length as
measured at step 2.
Note:
The cut edge of strap should be flat to
have good contact of fiber optical
detection.
Cutting
line
Back Cover
Edge Line

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
9
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
5. Please note that the cutting line should
be on the groove between two scales
for easy cutting and wearing purpose.
6. While cutting the strap by using the
dedicated strap, it should proceed with
3 stages cutting procedures. Keep
cutter and strap at 90-degree angle to
make sure that the cutting edge should
be flat.
(1) 1ST stage: Cut slowly from strap
edge to 2/5 of strap width (as
marked “1” of right picture).
(2) 2nd Stage: Continue to cut 1/5 of
strap width, where is the fiber
optical wire, by one-time cut to
avoid from bumpy cutting edge
(as marked “2” of right picture).
(3) 3rd Stage: Continue to cut 2/5 of
strap width (as marked “3” of right
picture).

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
10
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
7. Cut procedures are completed.
8. Put up the Jelly cover at the end of
strap. Please refer to NB5 Jelly cover
assembly SOP.
9. Fix the strap clip at the end of strap.
10. Insert the strap with strap clip into the
socket chamber at rear cover right
side. Press the strap deeply into the
chamber. Make sure the strap can not
be pull-off from the strap chamber.
Snap
Snap

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
11
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
11. Activated. Start tracking.
12. While using wall charger, aim the
charger connector (female) to NB5
charge socket (male), push till the end
to lock the device. Unplug the wall
charger in correct direction to avoid
from charge socket or charger
malfunction.
13. Connected and charged.

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
12
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
Cutting Tools
1. Make sure that the front side of the cutting tool faces to you and that the strap’s entrance
direction.
The spare blades are restored in the red rectangle.
2. Check that the blade is right on the block that should be cut.

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
13
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
3. After making sure the location is right, push the top of cutting tool to cut the strap
4. Exchange the blade if needed.
Release the screw ant then remove the blade. Note that releasing completely the screw is not
necessary.
Notice the direction of the blade since we need to install the spare blade on the same direction
later.

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
14
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
5. Install the blade. Please make sure the edge of the blade is inside the white area on the
cutting tool.
Push the top of cutting tools to the bottom so that the blade is back to the right place and
screw it up.

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
15
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
NB5 SMS Command Quick Setting
SMS Command setting
1. Any setup command must be started with a “#” sign and ended up with a “*” sign. Please note
that all the characters which include “#”, “*”and comma (,) should be HALFWIDTH form.
2. Please be aware of the upper (capital)/lower cases when entering the SMS command.
3. While entering any SMS command, note that NO SPACE is allowed between the characters,
comma and signs in the
SMS.
4. The comma (,) can be abbreviated if no further setup required for the command besides Set
up APN for 3G Service. Please refer to the examples of Set up Auto Report.
5. The device will update setting only when the password, username and setup command are all
correct.
If the command is not valid, a failure report is going to be sent to the user’s cell phone.
6. If the device set up the authorized number, SMS commands should be sent via authorized
number.
7. If the command is valid, a success report is going to be sent to the user’s cell phone.
8. Please make sure that the Call-Forward function of SIM card is turned off and Call-Display
function of SIM card is turned on.
9. Please make sure that the PIN-Code of SIM card if off. If the PIN-Code is necessary, use 0000
as PIN-Code.
SETP 0: Send the Alarm-OFF Command
STEP 1: Set up Username/Password (Optional)
STEP 2: Set up Phone Book and Security Phone Number (Optional)
STEP 3: Set up HA ID
SETP 4: Set up RF Detection Range Test (Optional)
SETP 5: Set up RF Power
STEP 6: Set up APN for 3G Service
STEP 7: Set up Route for Data Transmission
STEP 8: Set up URL and TCP/UDP IP Address
STEP 9: Set up Auto Report (Optional; default setting 60 seconds/each report)
STEP 10: Request IMEI Number

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
16
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
SETP 0: Send the Alarm-Off Command
Once the events such as strap violation and device tamper are triggered, NB5 will send the reports with the
alarm message followed by the beep sound and vibration.
This command is used to deactivate the alarm status, and then the device will be detecting the events.
Setup Format:#<User Name>, <Password>, <Function Mode>*
Example:#username,0000,alarmoff*
(1) Turn on ‘buzz sound when alarming’ function (Function Code 19).
Example: #username,0000,19,1,1 (0 means to disable it)*
The 1st parameter is for toggling the buzz alarm function. The 2nd is for toggling the vibration alarm function
(2) Once the events are triggered, deactivate all alarm by sending Alarm-Off commands if it’s necessary.
Example: #username,0000,alarmoff*
Note: If triggered events occurred, vibration and buzz alarm can be stop temporarily by sending Alarm-Off
commands. However, afterward, vibration and buzz alarm will be generated again if triggered events
continuously occurred.
SMS Text
Description
#
Start sign.
username
Default ID of BRACELET.
If you have changed the Username, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
alarmoff
Function to turn off all alarms
*
End sign.
Table: Alarm-off Setup Format Description
Situation
Message Reply
Setup Succeeds
[username] +, Alarm is set off.
Table: Alarm-off Setup Response Description

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
17
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
STEP 1: Set up Username/Password (Optional)
Set up Username
Generally, SMS command execution needs correct user name (I.D) with password, or it will remain the same
setting.
The SMS command default user name is “username”. It can be changed by following the command format.
For example, entering the SMS command as the following allows user to change the user name from “username”
to a new user name “abc”.
Only enter new command with new user name after it has been changed.
Setup format:#<username>,<Password>,<Function Code>,<New username>*
Example:#username,0000,1, abc *
SMS Text
Description
#
Start sign.
username
Default ID of Bracelet.
If you have changed the username, please use the updated one.
0000
Default password of Bracelet.
If you have changed the password, please use the updated one.
1
Mode 1 defines user name setup mode.
abc
New defined user name.
At the maximum of 16 letters which can only be a~z,A~Z,0~9, @ - _ /
*
End sign.
Table: Username Setup Format Description
Situation
Message Reply
Setup Succeeds
[username] + Device username is updated.
Setup Fail
[username] + Device username setup fail!
Incorrect username or
command format
[username] + command error
Table: Username Setup Response Description

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
18
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
Set up Password
Generally, SMS command execution needs correct user name with password, or it will remain the same setting.
The SMS command default password is “0000”. It can be changed by following the command format.
For example, entering the SMS command as the following allows user to change the password from “0000”to
a new password “1111”. Only enter command with new password will be valid for setting change after it has
been changed.
Setup format:#<username>,<Password>,<Function Code>,<new Password>,<new Password>*
Example:#username,0000,2,1111,1111*
SMS/ COTA Command
Description
#
Start sign.
username
Default ID of the device.
If you have changed the username, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
2
Mode 2 defines the password setup mode.
1111
New password (Please note at the maximum of 4 number)
1111
Reconfirm the password
*
End sign.
Table: Password Change Format Description
Situation
Message Reply
Setup Succeeds
[username] + Device Password is updated.
Setup Fail
[username] + Password setup Fail!
Table: Password Change Response Description

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
19
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
STEP 2: Set up Phone Book and Security Phone Number (Optional)
Security Phone Number allows limited administrators to manage and change the settings of the bracelet.
When the Security Phone Number is set, even the User Name and Password are correct, if the setup phone
number is not matched, the setup or any change will be invalid. Please be careful when setting up Security
Phone Number.
Security Phone Number also is the number that is used when the router is set as HTTP/SMS, TCP/SMS or SMS
mode.
If the router of the device is set as those above, the device will send the reports via SMS to the Security Phone
Number as the backup router in the occasion in which the device cannot send out the reports due to the poor
GSM signal or something.
The maximum set of Security Phone Number is 3. We can simply set up one number or two numbers as well.
Setup format: #<User Name>, <Password>, <Function Mode>, <Security Number1>, <Security Number2>,
<Security Number3>*
Example:#username,0000,5,+886123456789*
Example:#username,0000,5,+886123456789,+886123456789*
Example:#username,0000,5,+886123456789,+886123456789,+886123456789*
Using this command to empty the phone book:
Example:#username,0000,5,0,0,0*
Note that both adding and not adding the ‘+’ sign in front of the cellular phone number(s) are both acceptable,
while the ‘+’ sign should precede the national code.
SMS/ COTA Command
Description
#
Start sign.
username
Default ID of the device.
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
5
Mode “5”defines the Phone Book and the Security Number setup mode.
+886123456789
The Security Phone number 1 and Phone number 1 you would like to assign to the
device.
+886123456789
The Security Phone number 1 and Phone number 1 you would like to assign to the
device.
+886123456789
The Security Phone number 1 and Phone number 1 you would like to assign to the
device.

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
20
www.etek.com.tw
© Unictron Technologies Corp.
All specifications subject to change without notice.
www.sanav.com
www.unictron.com
*
End sign.
Table: Security Phone Number Setup Format Description
Situation
Message Reply
Setup Succeeds
[username] + Device phone book is updated.
Table: Security Phone Number Setup Response Description
STEP 3: Set up HA ID
The bracelet (HA) ID is set for identification. The ID number ranges from 1 to 9999.
The ID will be shown in the reports.
E.g.
imei=356496041252545&rmc=$GNRMC,020733.00,A,2457.80794,N,12125.53854,E,0.012,,170720,,,A*67,
AUTO,I0200,,,,9999,M14,4182mV,33,1.48,466,1,24A5,13E16E9,30,FFFF,29,10613,26,19,FFFF,195,10613,26
,19
NB5’s HA ID is for the purpose that user can quickly recognize which bracelet (NB5) is and manage it more
easily.
Setup Format:#<username>, <Password>, <Function Mode>, <HA ID Number>*
Example:#username,0000,haid,200*
SMS Text
Description
#
Start sign.
username
Default ID of Bracelet.
If you have changed the Username, please use the updated one.
0000
Default password of Bracelet.
If you have changed the password, please use the updated one.
haid
Mode “haid”defines HA ID setup mode.
200
HA ID number. Ranges from 1 to 9999.
*
End sign.
Table: HA ID Setup Format Description
Situation
Message Reply
Setup Succeeds
[username] + setup OK. Device ID setting is updated.
Table: HA ID Setup Response Description
Table of contents
Other SANJOSE Technology GPS manuals