SCALIX PRECISION BALANCE
FGL-SERIES
INSTRUCTION MANUAL

SPECIFICATIONS
FEATURES
•g, ct oz or tola Conversion
•Auto Zero Tracking
•Tare Facility
•Large 15mm LCD
•Auto Backlight LCD
•User Calibration
•Plastic Protection Cover
•Low Battery Indication
IMPORTANT: Remove batteries if using AC/DC Adaptor
2
CALIBRATION
All electronic scales and instruments are affected by environmental
conditions in which they are used. Periodic calibration checks should be
carried out. At least once a year, a full calibration & verification should be
carried out to certified tractability.
ATP Instrumentation Ltd offer full verification and calibration to traceable
standards and documented procedures. A certificate of calibration is then
issued detailing the true weight and the scale readings in laboratory
conditions.
Please call our technical helpline on 01530 566804 for currents prices and
turnaround times.
7
Model number
Capacity
Resolution
Weighing Pan
FGL-300
300g
0.005g
115mmØ
FGL -600
600g
0.01g
115mmØ
FGL-3000
3000g
1g
150 x 175mm
FGL-3001
3000g
0.1g
150 x 175mm
Net/gross weight
850/1500g
Package
Standard carton: 32.5×22.5×11.5 (cm3)
Operating
Temperature
0-40°C (32-104°F)
Power source
4 x AAA Size Batteries or
AC/DC Power Adapter 9V/300mA

Tare Facility
If a container is to be used, place the container on to the pan. The scale will
display the container’s weight. Press [ZERO] and display will read zero.
Place items in to the container and the displayed weight will be the contents
only.
Check Weighing
Place an item or weight on to the pan. Press [TARE] and the display will
read 0.00 (reference). Remove the item or weight. The display will read
(minus) the weight value removed. Place a similar item on to the pan. If the
scale reads zero there is no difference to the (reference). If there is a
difference the display will read a plus or minus value to the (reference).
Auto Power Off
After approx. 3mins, it can be user disabled.
Make sure the scale is switched off, press and hold down [TARE], then
press [ON/OFF], whilst keeping [TARE] pressed, the display will show
A_ON or A_OFF. Press [TARE] to select A_ON to activate power off
function or A_OFF to deactivate power off function.
Turn the scale off to save the change.
Low Battery Indication
If the power level falls below the required level then will be displayed.
The batteries should then be changed. To continue weighing with this
symbol displayed will result in non-accurate weighing.
IMPORTANT: Remove batteries if using AC/DC Adaptor
6
DESCRIPTION
SIDE
AC/DC Power Adaptor
Socket
TOP
Weighing platform
The arch face of platform is front.
Correct the direction of the pan.
Display
ON/OFF key
Turn the scale
power on/off.
TARE key
Set display to zero or
Subtracts weight of a container.
MODE key
Change weighing units
BOTTOM
Battery compartment
Battery compartment cover
Batteries
Use 4 x AAA Batteries
DISPLAY
ZERO indicator Weighing unit
STABLE indicator
Indicates when the reading is stable.
Low battery indicator
3

PREPARATION
Installing Batteries / Connecting the AC/DC Adaptor
Batteries
Battery Remove the battery compartment
compartment cover and insert four batteries(R6P/LR6
/AAA) into the battery compartment,
taking extreme care that the polarities
plus and minus is observed.
4 x LR6/AAA size
Dry batteries.
Battery compartment cover
AC/DC 300mA PowerAdapter (optional)
Plug theAC/DC Adapter to the
AC/DC Adaptor adapter socket on the side.
socket The AC input requirement could
be 110,120,220,230 or 240Volts
(50/60Hz) depending on the area
where used, so please verify that
the adaptor is correct
Setting up the scale/balance
CAUTION
Avoid installing the scale/balance in direct sunlight that may cause
discoloration or malfunctions. Place your scale/balance on a firm weighing
table so that the scale/balance is level. (The scale/balance will not perform
accurately when it is not level.)
4
Before weighing
Whenever possible, please allow the balance to warm up for 10 minutes
after first turning the power on, so that the balance will function properly and
accurately.
Error messages
EEEE: Overload
: Low battery
Weighing Functions
Press [ON/OFF] to turn on the scale. When the power is turned on the scale
will go through a self-verification process and display all segments (8888)
for a few seconds and then "0" will appear on the display. The scale is ready
for use.
Unit Weight Selection
To select the weighing unit, press [UNIT] to select g or ct or oz or tola. An
indicator confirms the selected weight unit.
LCD Backlight
Place the objects to be weighted onto the scale’s pan. The weight is then
displayed. The scale has an AUTO-BACKLIGHT which activates when any
weight is placed on the pan. It will automatically turn off if the scale is idle.
5