Senseon 38TREL Series User manual

MODEL 38TREL
Senseon side mount slide with integrated
electronic Touch Release lock.
100lb slide load rating.
Finish: Clear electroplate(C)
Lengths: 12"–28" [300 mm–700 mm]
Note: cabinet depth must include
an additional 3'' to allow room for
the locking mechanism and wiring
at the back of the slide.
SlideLoad
Rating: Up to 100 lbs. [45.5 kg] per pair*
Travel: Full extension
Disconnect: Handed lever disconnect
Height: 1.80'' [46mm]
Height w/Lock: 2.50'' [63.5mm]
Side Space: 0.50 +0.031/-0.0 [12.7mm +0.8/0.0]
or 1/2 + 1/32
Mounting
Hardware: #8 pan or truss head screw
(recommended max. head height 0.100)
Features: Electronic locking mechanism with
manual override. Lock withstands
up to 250 pounds of force.
Drawer opens about 2" when activated by touch. • Slide load rating based on 18" slides mounted in a 24" wide drawer cycled 50,000 times.
38TREL
QUICK REFERENCE
Side Space: (1/2"+1/32) X 2
Lengths: 12"–28''
Height: 1.80"
Slide Load: 100-lb.•
Lock Force: 250 lbf.
APPLICATIONS: Provides an
easy-to-install method to secure
and control access to drawers.
This product is covered by
U.S. (8,328,299), and various
patents pending.
1.38
[35]
.70
[17.8]
.35 [9]
TYP.
2.38
[60.5]
5.04
[128]
A
B
C
D
.42
[10.6]
1.77
[45]
Ø.172
[4.4]
TYP.
.172 x .38
[4.4 x 9.5]
TYP.
.187 x .310
[4.7 x 7.9 ]
TYP.
5.04
[128]
EF
SLIDE LENGTH
▲ SLIDE LENGTH W/LOCK
.85
[21.6]
1.35
[34.3]
1.38
[35.1] .35
[9]
.50
[12.7]
Ø.180
[4.6]
(3X)
.180 x .38
[4.5 x 9.5]
TYP.
Ø.250
[6.4]
TYP.
.45
[11.4]
TYP. .50
[12.7]
TYP.
8.82
[224]
*
.25
[6.4]
¤
SLIDE TRAVEL
**
Lever
disconnect
(not shown)
2.50
[63.5]
.50
[12.7]
1.8
[46]
¤
Inch
[mm]
¤Manual Override
* Only available on 24"–28" lengths.
** Min Gap for connector 1/4" [6.4 mm]
Part
Number
Slide
Length
Length
w/Lock Travel A B C D E F
D38TR-EL12 11.81
[300]
14.61
[371]
12.00
[305]
D38TR-EL14 13.78
[350]
16.58
[421]
14.00
[356]
D38TR-EL16 15.75
[400]
18.55
[471]
16.00
[406]
12.60
[320]
D38TR-EL18 17.72
[450]
20.51
[521]
18.00
[457]
12.60
[320]
13.86
[352]
D38TR-EL20 19.68
[500]
22.48
[571]
20.00
[508]
12.60
[320]
16.38
[416]
D38TR-EL22 21.65
[550]
24.45
[621]
22.00
[559]
12.60
[320]
16.38
[416]
13.86
[352]
17.64
[448]
D38TR-EL24 23.62
[600]
26.42
[671]
24.00
[610]
8.82
[224]
16.38
[416]
13.86
[352]
18.90
[480]
D38TR-EL26 25.59
[650]
28.39
[721]
26.00
[660]
8.82
[224]
16.38
[416]
21.42
[544]
13.86
[352]
21.42
[544]
D38TR-EL28 27.56
[700]
30.36
[771]
28.00
[711]
8.82
[224]
11.34
[288]
16.38
[416]
21.42
[544]
13.86
[352]
21.42
[544]
Drawer opened a
minimum of 2" when
pushed and released.
Minimum gap .080
Drawer front face
Push and release
.080 [2] to open
+.040
-.000 [2 ]
+1
-0
▲

Slide Installation
Install Cabinet Member
1. Separate the slide members by first actuating the manual
override located on the locking mechanism.
2. Then, lift the disconnect lever to release the inner (drawer)
member.
3. Overlay drawer front:
- Conventional mounting, see Figure 1.
- 32 mm system mounting, see Figure 2.
System Holes
2.0 mm
38.1
mm
Min.
For overlay
drawer front
37.0 mm Cabinet
Member
32 mm system mounting - CabinetFigure 2.
Conventional mounting - Cabinet
Cabinet Member
1 7/8"
Min. 1 1/2"
Drawer
For overlay
drawer front
Figure 1.
IMPORTANT:
• Be sure the interior cabinet depth allows for an additional 3"
beyond the length of the slide to provide room for the locking
mechanism and wiring (Figure 1). See the chart below for
minimum cabinet depth. For the inset drawers, be sure to
provide sufficient cabinet depth to allow for the slide setback.
Slide Length Min. Cabinet Depth
16" 19"
18" 21"
20" 23"
22" 25"
• Slides will not function properly if side space is less than .50"
[12.7 mm]. For optimum performance, construct drawer 1-1/16"
[27.0 mm] smaller than the opening of the cabinet.
Installation Instructions 2
WARNING! Before installing the drawer, insure
you have access to the lock’s manual override
lever or the activation device must be connected
and working properly. Otherwise, you will not be
able to unlock the slide and open the drawer.
4. Inset drawer front:
Slide setback is the thickness of the drawer front plus 1/8"
[3.2 mm].
5. Use only the 32 mm system holes or the wood screw holes
located at the tip of the breathing tabs. Do not use any other
holes on the cabinet member for mounting (Figure 3).
Install Drawer Member
1. See Figure 4 for drawer member setback.
2. Install the drawer member with a screw through the cam adjuster
and a screw through a hole or slot at the rear (see Figure 4).
Use all mounting tabs to achieve load rating.
Figure 3.
No
Yes
Manual Override
Cabinet Member Fastener Locations
Refer to Senseon Installation Guide for complete system instructions.
11/16" [17.8]
Drawer Member Setback
Flush for conventional mounting
2mm (+1.0/-0.0) for 32mm system mounting
Cam Adjustment
1/4" [6.4]
1 1/4" [31.8]
Figure 4.
Conventional Mounting and 32 mm Mounting - Drawer
Drawer Insertion and Adjustment
WARNING! Before installing the drawer, you must
have access to the lock’s manual override lever
or the activation device must be connected and
working properly. Otherwise, you will not be able to
unlock the slide and open the drawer.
1. Make sure the ball bearing retainers in the cabinet are fully
forward. Install drawer into cabinet and close the drawer.
2. Install additional screws to secure the drawer-member after
verifying form and function install.

Slide members and ball retainers: Cold rolled steel
Ball bearings: Carburized steel/acetal polymer
Lock: Zinc and black polymer
RoHS compliant
NOTE: Specifications, materials, prices, terms, and
delivery are subject to change without notice.
Specications
A pair of slides packaged in a box with two 38TREL e-locks.
Bulk Pack (P): Full box quantity, electronic locks are packaged in
a larger box with 4 individual boxes with a pair of 38TREL each.
Required Kits
Proximity Kit: One proximity kit per each Senseon system.
Part number SEPROX-US-Kit1.
This kit includes:
1 RFID Reader
1 Power Supply
1 Reader Holder
1 DC Power Cable
1 Reader Splitter Cable
1 AC Cord
1 Proximity Kit Box
2 Power Supply Holders
12 Cable Clips
Hub Kit: One Hub Kit per cabinet opening (drawer and door).
Modular wiring kit part number SEHUBX-Kit1.
This kit includes:
1 Hub Assembly
2 Hub to Lock Cable
4 Cable Clips
6" Double Stick Tape
Note: To complete your order refer to required kit part numbers.
D38TR-EL (Touch Release)
For the most current technical information please visit www.accuride.com
Optional Kits
Linking Cables: To connect multiple banks of lock openings.
Top Linking SELINK-TOP-KIT1
Bottom Linking SELINK-BTM-KIT1
Extension Cables: Available in 3 lengths
6" SECBLX-6-KIT1
12" SECBLX-12-KIT1
24" SECBLX-24-KIT1
Note: See installation and ordering guides.
Click here for Installation Guide
Click here for Ordering Guide
Warranty
Copyright © 2019 Accuride International Inc. 3700-9575(1271)-MK975-R3-1019
For warranty information visit
http://www.senseonsecure.com/warranty
Packaging Options 3
Slide Ordering Instructions
For the most current technical information visit www.accuride.com
Accuride International Inc.
12311 Shoemaker Avenue
Santa Fe Springs, CA 90670
TEL (562) 903-0200
FAX (562) 903-0208
Manufacturing, Engineering, and Sales
United States • Germany • Japan •
Mexico • United Kingdom • China
WARNING: This product can expose you to chemicals including nickel,
which is known to the State of California to cause cancer and birth defects or
other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Complete your slide order for 38TREL by specifying the
following:
8 prs D38TR EL 14 P
Total Slides Required
Slide Model Touch Release
Electronic Lock
Slide Length
Packaging
This manual suits for next models
9
Popular Rack & Stand manuals by other brands

PT
PT W54024 owner's manual

Starburst Technologies
Starburst Technologies SB-3790ART-FM installation manual

Atdec
Atdec Levitate User operating guide

CHIEF
CHIEF K0W1I2TB installation instructions

Cerwin-Vega
Cerwin-Vega CVE Series instruction manual

Premier Mounts
Premier Mounts GB-PIPE1 installation instructions