Safety regulations
Please read the safety regulations and operation guide
carefully before operating.
Please read all of the operational guide and safety regulations
in this manual before operation . Improper operations without
complying with this manual guided could cause damage to the
device, influence on measurement result or bodily injury to
the user.
The instrument is not allowed to disassemble or repair in any
ways. It is forbidden to do any illegal modification or
performance change for laser emitter. Please keep it out of
reach of children and avoid using by any irrelevant personnel.
It is strictly prohibited to shoot eyes or other parts of body with
the laser. It is not allowed take the laser to shoot any objects’
surface with strong reflecting.
Due to electromagnetic radiation interference to other
equipment and devices, please don't use the meter in the plane
or around medical equipment, don’t use it in inflammable,
explosive environment.
Discarded batteries or meter device shall not processed just like
household garbage, please handle them in line with related law
and regulations.
Any quality issues or any questions on the meter, please contact
local distributors or manufacturer in time, we are ready to offer
solutions for you.
- 1 -

DISPLAY / KEYBOARD
Keyboard
Turn on/Measuring
Area/Volume/
Pythagorean Mode
Turn off/Remove
Reference Point/
Unit Switch
Addition &
Subtration/Save
Power Supply
Area, Volume and
Pythagorean
Laser on
Maximum
Auxiliary Display
Record
Minimum
Major Display
Display
Length
- 2 -

Batteries Installation
Start the Instrument / Menu Setting
Under off status, press button , device and laser
get starting simultaneously and stand by for
measurement.
Battery Installation and Replacement
Turn On/Off the Instrument
Under on status, long press button for 3 seconds
to turn the device off. The device can also be shut off
without any operation for 150 seconds.
Discharge the battery door on the back of device, and
place battery according to correct polarity, then cover
the battery door.
Only 1.5 V AAA alkaline battery is applied to the meter.
If not used for a long time, please take out the battery to
avoid battery corrosion to meter body.
- 3 -

Short press key to change the reference point.
The device reference point by default is rear.
Back Light On/Off
Changing Reference Point
Long press button , reset current measurement
unit, the default unit is: 0.000m. There are 6 units for
selection.
Unit Setting
The back light is set to turn on and off automatically.
The back light can be on for 15s while operating, and
it will be shut off automatically in 15s when there is no
operation to the device.
Keys sound
When the rangefinder is turned on, the buzzer sound
will be turned on by default and cannot be muted.
Units:
Length Area Volume
1
6
5
4
3
2
0.000m
0.00 ft
0'00" 1/16
0 1/16 in
0.0 in
0.00m
0.000 m2
0.00 ft2
0.00 ft2
0.00 ft2
0.00 ft2
0.00 m2
0.000 m3
0.00 ft3
0.00 ft3
0.00 ft3
0.00 ft3
0.00 m3
- 4 -

Single Distance Measuring
Continuous Measuring
Long press button under measuring mode and enter
into continuous measuring mode.
Maximum and Minimum measuring results display in
auxiliary display area.
Present result displays in major display area. Short press
botton or to exit continuous measuring mode.
Turn on the laser beam by short press of the button
under measuring mode, press the button again for
single measurement of length, then the measured results
displayed in the major display area.
Self-Calibration
This function can keep the precision of the device.
Instruction: Power off, long press button , and then
press . Release the button , then release button
till "CAL" and a figure shows on the screen.
User can adjust the figure with button according
to the accuracy of the meter.
Adjusting range: -9 to 9mm, then, press button to
save the calibration result.
- 5 -

Area Measurement
Volume Measurement
The device calculates and shows the result in the major
display area.
Press , clear off the result and measuring again if
necessary.
Press again to exit the mode.
Press button twice to enter volume measurement
mode. A will shows on the top of screen. Please
follow the below instruction for volume measuring:
Press for length
Press again for width
Press thirdly for height
The resent measuring result of length is showed in the
auxiliary display area. Press , clear off the result
and measuring again if necessary.
Press once for length
Press again for width
The device calculates and shows the result in the major
display area.
Press button , shows on the screen. One of
the side of rectangle blinking on the display, please
follow the below instructions for area measuring:
Press again to exit the mode.
- 6 -

Pythagoras
Short press four times, when one leg of
blinking.
Press , measure the length of one leg (a)
Press , measure the length of another leg (b)
Device calculates the length of hypotenuse (x)
Short press three times to enter Pythagoras mode,
the hypotenuse of blinking.
Press , measure the length of hypotenuse (a)
Press , measure the length of one leg (b)
Device the length of another leg (x)
1. Calculate the second leg by measuring the hypotenuse
and another leg.
2. Calculate the hypotenuse by measuring the length of
two legs.
There are four Pythagoras modes in case that user gets
hard to reach the target.
- 7 -

Addition / Subtraction
4. Press six times till the hypotenuse of blinking
on the screen.
Press , measure the length of one hypotenuse (a)
Press , measure the length of one leg (b)
Press , measure the length of another hypotenuse(c)
Device calculates the length of the leg in full line (x)
Press , measure the length of one side (a)
Press , measure the length of the median line (b)
Press , measure the length of another side (c)
Device calculates the length of the leg in full line (x)
3. Press five times till the one side of blinking
on the screen.
Legs must short than hypotenuse, or there will be "err"
shows on screen. In order to guarantee the accuracy,
please make sure all measurements are start from the
same point.
The device can be used for length addition and
subtraction. Press to select the function once get
the length measuring result.
Short press , "+" shows in the major display area,
entering cumulation mode. Value of last measurement
and the result of cumulation will be showed on the
screen.
- 8 -

Do round-robin selection between continous addition
and continuous subtraction by pressing button .
Short press , "-" shows in the major display area,
entering subtraction mode. Value of last measurement
and the result of subtraction will be showed on the
screen.
Area cumulative function: Measure the first area as
showing in PIC1. Then press button , and measure
the second area as showing in PIC2, there is a "+" in the
left bottom. At last, press button to get the summation
result of these two areas which is showing in PIC3.
Not only length can be caculated in addition and
subtraction, but area and volume can do the caculation
as well. Take area as sample:
PIC1 PIC2 PIC3
- 9 -

Record Function
Tips
Read / Delete the Record:
Long press button , read the records by press button
. Long press to clear up all the records.
Short press or to exit record mode.
In measurement mode, the current data is valid, the
instrument will automatically store, and the record
number at the top of the screen will continue to
accumulate.
Err1
Err
Err2
Err3
Err4
Err5
Info
message Cause Solution
Signal is too weak
Out of distance
measurement range Use the device within the range
Chose the surface with stronger
reflectance. Use the reflecting
plate.
Signal is too strong
Chose the surface with weaker
reflectance. Use the reflecting
plate.
Low battery voltage Change the power supply.
The working
temperature is out
of working range
Pythagoras
measuring error.
Re-measure and ensure that
Hypotenuse is bigger than
Cathetus.
Use the device in the specified
temperature.
You may get some warning information as below:
- 10 -

Technology Specifications
0˚C~40˚C
-20˚C~60˚C
8000 times for single measurement
√
√
√
√
√
√
√
√
Ⅱ
150s
20s (single measurement)
99 units
630-670nm,<1mW
±(3mm+d 10-4) *
*
20%~80%RH
1.5V 2xAAA
0.05-40m
SW-G4S
0.05-60m
SW-G6S
0.05-80m 0.05-100m
ITEM
104x48x25mm
Working Range
Distance measure-
ment precision
Continuous measure-
ment function
Area and Volume
measurement function
Pythagorean proposition
measurement function
Add and subtract
measurement function
Area measurement
function
Min/Max value
Self-Calibration
Laser level
Laser type
Max storage
Automatically
cut off laser
Automatic shutdown
Battery life
Buttons/Keys sound
Storage temperature
Working temperature
Storage humidity
Battery
Dimension
Note: Use a target plate to increase the measurement range
during daylight or if the target has poor reflection properties.
SW-G8S SW-G10S
- 11 -

Instrument Maintenance
Delivery Package
The meter should not be stored in high temperature
and strong humidity environment for long time. If it
is not used very often, please take out the battery and
place the meter in the allocated potable bag and store
in cool and dry place.
Please keep the device surface cleaning. Wet soft cloth
is applied to clean dust, but erosion liquid is never
allowed to use for the meter maintenance. Laser output
window and its focus lens can be maintained according
to maintenance procedures for optical device.
Please check if the accessories are completed according
to the below list.
Giftbox
User' s manual
Laser distance meter 1
1
1
1
2
3pc
No. Item Unit QTY Note
pc
pc
*Typical Tolerance: ±3mm, when reflectivity 100%
(white surface), environment light <2000 LUX. 25°C
Tolerance is usually affected by the distance,
reflectivity, and environment light etc. It probably
gets tolerance around ± (3mm+0.1mm/m) .
- 12 -


Hongkong Sndway Instrument Company Limited
Url: www.sndway.com
E-mail: market@sndway.com
This manual suits for next models
3
Table of contents
Popular Laser Level manuals by other brands

GEO-Laser
GEO-Laser NL-9V operating instructions

ADA INSTRUMENTS
ADA INSTRUMENTS ROTARY 400 HV Servo operating manual

geo-FENNEL
geo-FENNEL Pro Series user manual

Nedo
Nedo Acceptor 1 operating instructions

Johnson Level & Tool
Johnson Level & Tool 40-6164 instruction manual

Pittsburgh
Pittsburgh 20110 Instructions and precautions