Socket AC4088-1657 User manual

Charging Mount SKU# AC4088-1657 P/N 9010-01657
User Guide
Charging Mount

Command Barcode
label to place on mount
USB Charging Cable
© 2020 Socket Mobile, Inc. All rights reserved.
Socket®, the Socket Mobile logo, SocketScan®, DuraScan®, DuraSled™, DuraCase™ and Battery Friendly® are registered
trademarks or trademarks of Socket Mobile, Inc. Microsoft® is a registered trademark of Microsoft Corporation in the
United States and other countries. Apple®, iPad®, iPad Air®, iPad mini®, iPad Pro®, iPhone®, iPod touch®, Objective-C®, Swift™,
and Xcode® are registered trademarks of Apple, Inc., registered in the U.S. and other countries. The Bluetooth® Technology
word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Socket
Mobile, Inc. is under license. Other trademarks and trade names are those of their respective owners. Socket Mobile is not
affiliated with Socket Internet Inc., a provider of data, voice and Internet communications services.
Charging Mount
Hanger Bolt
2 x Hex Nuts
Package Contents

Magnet
Hook
Charging Mount
*Illuminates Red when connected to AC adapter.
Charging Pins
LED*
Product Information
3

A. Charging Mount
B. Micro USB (2m)
C. Cushion Crown
D. Pem Cap / Camera Mount*
E. 2 x Hex Nuts
F. Hanger Bolt**
A.
B.
D. E.
F.
C.
*Optional for Camera Mount (see page 14)
**Optional for table mount
¼” - 20
Machine
bolt thread
Screws into
wooden
surface
Tapered
lag-screw
Screws into
camera mount
or Charging
Mount
Assembly Overview
4

A. Remove Micro USB cover.
B. Insert Micro USB connector into port and fit
usb cable into the cord keeper.
C. Secure the cable to prevent from movement.
A.
B.
C.
How to connect USB Cable
5

When charging the scanner, make
sure the charging pins on the
Mount and the scanner make
contact with each other and the
red LED on the Mount is illumi-
nated.
“Beep
Beep”*
Charging Mount Operations
6

4-6 inches
(10 - 15 cm)
Charging Mount Operations
7

Charging Mount Modes
Mobile Mode - Normal (default)* Scan-
ning this barcode will enable the scan-
ner to enter mobile mode. It will always
be in manual trigger mode even when
placed in the mount or cradle.
*Scanner Factory Reset returns to Mo-
bile Mode. #FNB 41FBA50000#
Auto Mode (Presentation Mode)
Scanning this barcode will enable the
scanner to enter auto mode. When the
scanner is in auto mode, it will switch to
presentation trigger mode when it
detects power on the cradle pins. When
the scanner is removed from the cradle
it will remain in presentation trigger
mode until the users press the trigger.
At that point it will switch to normal
manual trigger mode. Auto Mode com-
mand barcode is also printed on the
product label.
#FNB 41FBA50003#
Command Barcodes
8

Auto Mode (In the Mount)
Action Behavior
Notification
Beep
Pattern
LED Activ-
ity
Vibrate
Place
Scanner in
the Mount
Scanner
switches to
Presenta-
tion Mode
High-high
tone confirms
proper seat-
ing*
Battery
status LED
is disabled
None
Place a
barcode in
the
scanner’s
field of
view
Decode
Barcode
1 Beep when
data
successfully
scanned
Green
LED blinks
(while
scanning)
None
Auto Mode: Barcodes placed in the Scanner’s field of view are
automatically scanned.
*Note: Auto Mode available with the following scanners: D740,
D745, D750, D755, D760, S740, S760.
Auto Mode
9

Action Behavior
Notification
Beep
Pattern
LED
Activity
Vibrate
Remove
the Scanner
from the
Mount and
press the
Trigger but-
ton
Scanner
switches
to Mobile
Mode
None Battery
Status LED
is Enabled
Enabled
Press the
Trigger
button
Decode
Barcode
1 Beep
when Data
successfully
scanned
Green
LED blinks
(while
scanning)
Vibrate
when Data
successfully
scanned
Mobile Mode: Pressing the Trigger button initiates a scan.
Mobile Mode (Not in the Mount)
Auto Mode
10

1. Pair and connect the D740, D745, D750, D755, D760, S740, S760 to
your device prior to placing the scanner in Auto Mode. The Scan-
ner is not discoverable when in Auto Mode and in the Mount.
This facilitates a fast connection to the current connected device
when powered on (for example the start of the new business
day).
2. The Trigger button must be pressed to disable Presentation
Mode (and enable Mobile Mode) after the scanner is removed
from the Mount.
3. The Scanner will not turn off when its in Presentation Mode and
in the Mount under AC Power.
4. To avoid excessive power drain, the scanner should not be left
out of the Mount in Auto Mode. Either press the Trigger button
or Power off the scanner.
Auto Mode (Continued)
11

We include a Hanger Bolt to secure the Charging Mount directly to
a wooden surface. Since the Pem Cap connects to a Camera Mount,
popular with IP Cameras, many OEM solutions are available which
do not require the Hanger Bolt.
If you plan to use the Hanger Bolt follow the special instructions
for mounting on a wooden surface.
If you have many Hanger Bolts to install, you may want to use
a ¼”-20 Hanger Bolt Driver with an Electric Screw Driver. (Image
below)
Instructions for Mounting on wooden surface
12
1/
4
“

¼“ x 1¾”
Special instructions for mounting on wooden surface:
1. Screw two Hex nuts (¼”-20 thread, not included) onto the
machine-threaded portion of the Hanger Bolt.
2. Use an open-ended wrench to lock the nuts against each other.
3. Drill a pilot hole into the surface you wish to place the
Charging Mount.
4. Thread the lag portion of the Hanger Bolt into this surface as far
as you can by hand.
5. Use a wrench on the outermost nut to drive the Hanger Bolt into
the surface.
6. When the lag portion is sufficiently threaded, unjam the two
nuts from each other, and run them off (unscrew them).
Instructions for Mounting on wooden surface
13

A. Attach the Pem cap to
your Camera Mount
(¼” - 20, ¾” depth
thread) and turn to
the right.
B. Attach the Charging
Mount to the Pem
cap.
A.
B.
Configuration When Using a Camera Mount
14

Dimensions
Charging Mount Width 1.80 in (46 mm)
Charging Mount Length 5.50 in (140 mm)
Antimicrobial Rating JLS z2801:2000 Test: 2.49 on MRSA 6.07
when cleaned with SaniCloth Plus cloth
wipes Biosafe HM4100, EPA#83019-1
CE MARKING AND EUROPEAN UNION COMPLIANCE
The unit under test was found compliant with all the applicable
Directives, 2004/108/EC and 2006/95/EC.
WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT
The WEEE directive places an obligation on all EU-based manufac-
turers and importers to take-back electronic products at the end of
their useful life.
ROHS STATEMENT OF COMPLIANCE
This product is compliant to Directive 2011/65/EU.
NON-MODIFICATION STATEMENT
Changes or modifications not expressly approved
by the party responsible for compliance.
RoHS
Product Specifications
Compliance Statement
15

Technical Support & Product Registration:
http://support.socketmobile.com
Phone: +1 800-279-1390 (US Toll Free)
+1 510-933-3020 (Worldwide)
Socket Mobile Developer Program:
Learn more at: https://www.socketmobile.com/developers
The User’s Guide (full installation and usage instructions) and
Command Barcodes (Advanced Scanner Configurations) can be
download at:
https://www.socketmobile.com/support/downloads
16
Helpful Resources


2020 6430-00362F Printed in U.S.A.
Other manuals for AC4088-1657
1
This manual suits for next models
1
Table of contents
Other Socket Rack & Stand manuals
Popular Rack & Stand manuals by other brands

MantelMount
MantelMount RB100 Addendum

Premier Mounts
Premier Mounts ECM-3763T installation instructions

Ergotron
Ergotron WorkFit-S installation manual

ULTIMATE SPEED
ULTIMATE SPEED 310469_1904 Assembly, operating and safety instructions

David Engineering & Mfg
David Engineering & Mfg PDR UCMM50 instructions

Middle Atlantic
Middle Atlantic Forward Series instruction sheet