Before you begin
To ensure safe operation, read the following instructions in their entirety.
WARNING
Warning is used to indicate the presence of a hazard that
can cause severe personal injury, death, or substantial
property damage if the warning is ignored.
CAUTION
Caution is used to indicate the presence of a hazard that
will or can cause minor personal injury or property dam-
age if the caution is ignored.
To reduce risk of injury or damage to the equipment:
• Plug only into grounded electrical outlets matching the nameplate
rated voltage
•Do not power the equipment with extension cords, power strips,
or multipurpose sockets
•Do not daisy chain more than (4) units together
•Equipment should only be used in a flat, level position
•Do not obstruct or cover the equipment in any way when in use
•Do not touch the heating element or shade when in use; surfaces
will be hot
•Do not operate unattended
•Closely supervise equipment operating in public areas and/or
around children
•Do not operate if equipment has been damaged or is malfunction-
ing in any way
• Keep equipment and power cord away from open flames, electric
burners or excessive heat
•Unplug equipment and let it cool before cleaning
•Unplug when not in use
• Save this manual for future reference
NOTICE:
Notice is used to note information that is important but
not hazard-related.
Function
Spring USA’s iLume is a streamlined, heat lamp with an adjustable height
and ability to be manipulated in multiple different configurations making
the heat lamp easily adaptable to any application.
The unit was designed specifically for keeping prepared food warm.
Food must be at or above serving temperature before being placed
under the heat lamp.
NOTICE:
The heat lamp only maintains temperature –
it does not cook or continue to cook food.
Electrical Requirements
Item# Voltage Phase Hertz Watts Amps Plug
2791-ILT 120 1 60 300 2.5 NEMA 5-15P
Daisy Chaining
The iLume has a built-in receptacle located in the back of the base of
the unit that allows for daisy chaining. The maximum number of iLume
heat lamps allowed for daisy chaining into one 15-amp/120-volt circuit is
4 lamps.
Installation
Inspect all part of the iLume prior to installation. If the unit is damaged,
do not use. Contact a supplier for a replacement heat lamp. To use the
heat lamp, place the unit on a flat, level surface and plug into a ground-
ed electrical outlet.
How to operate
Turn the iLume ON using the ON/OFF power switch located on the back
of the base of the unit. The iLume is ON when the LED lights found in
the shade of the lamp illuminate.
The heating element will begin to heat immediately.

4 5[email protected]om | springusa.com [email protected]om | springusa.com
CAUTION
Risk of fire or electric shock. Only operate this equipment
with food in place.
The iLume LEDs will always be ON and emit light when the unit is ON.
There are (2) light settings – HIGH and LOW. The HIGH setting is intend-
ed for use in settings with a considerable amount of surrounding light
and provides a spotlight on the food. The LOW setting is intended for
use in settings with little to no surrounding light. To change the light
setting, simply press the light switch found on the back of the base of
the unit.
See Figure 1 below for reference.
NOTICE: Lowering the height of the lamp will increase the heat
transferred to the food. Increasing the height of the lamp will de-
crease the heat transferred to the food.
Figure 1. Switches on Back of Base
To adjust the height of the lamp, simply grasp the stem of the lamp and/
or the loop end caps of the shade and manually move the shade. The
iLume is designed to hold any manually manipulated position.
See Figure 2 below.
Figure 2. Loop End Caps
CAUTION
Do not grasp the shade or heating element directly when
the unit is ON. Surface will be hot.
To turn the shade perpendicular to the stem of the unit, simply grasp
the loop end caps of the shade and turn the head of the lamp.
See Figure 3 below.
Figure 3. Shade Perpendicular to Stem
After use, always turn the iLume OFF using the ON/OFF power switch
located on the back of the base of the unit and allow the unit to cool
before handling.

6 7[email protected] | springusa.com [email protected] | springusa.com
Safety Feature
The iLume is equipped with a safety feature that will shut the power off
if the unit is not in an upright position or in a case of tipping or falling, to
avoid causing a fire
• When the vertical stem of the heat lamp is tilted at an angle
greater than 10 degrees, the heat lamp will shut off automatically.
It will automatically turn back ON when it is returned to its upright
position within approximately 2 seconds.
• When the heat lamp shade is tilted at an angle greater than 15
degrees, the heat lamp will shut off automatically. It will automat-
ically turn ON again when the heat lamp cover is returned to it
horizontal position within approximately 2 seconds.
Figure 4. Vertical Stem Tilted to the Vertical
Figure 5. Lamp Shade Tilted to the Horizontal
Maintenance
To clean the iLume, turn the unit off, unplug the unit from its power
source and allow to cool before handling. Wipe the unit down with a
sponge or cloth with a mild dishwashing liquid. Be sure to avoid the
heating element located in the shade of the unit. This does not need to
be wiped down. See Figure 6 below.
Figure 6. Underside of Shade
Dry with a clean, soft cloth. Never use any abrasive pads or scouring
powders. Completely dry the lamp before installing. Do not immerse
the heat lamp directly in water for cleaning – this will damage the unit.
To easily transport or store the iLume, ensure the shade of the lamp is
parallel to the stem and manually manipulate the lamp until it is in the
folded position shown below in Figure 7. The loop end cap closest to the
base will fit around the tab located in the front of the base to help keep
the unit in the folded position. See Figure 8 for reference.
Figure 7. Folded Position Figure 8. Tab on Front of Base

Troubleshooting
Never attempt to service any part of the iLume. Attempting to service
the heat lamp on your own, or through an unauthorized repair facility,
automatically voids your warranty, contact our Service Department at
630-527-8600. For service forms, visit the Spring USA website, www.
springusa.com
Service & Repair
For Limited Warranty information, visit the Spring USA website at
www.springusa.com/warranty
Warranty
Error Cause Solution
Lamp will not turn on The unit is not switched
on
Check that the unit is
plugged in correctly and
switched on
The plug and/or cord are
damaged
Call Spring USA Service
Department, 1-630-527-
8600
Power supply Check power supply
127 Ambassador Drive, Suite 147
Naperville, IL 60540-4079
P: 630-527-8600
F: 630-527-8677
www.springusa.com
Table of contents
Popular Outdoor Light manuals by other brands

Allen + Roth
Allen + Roth PL1588 quick start guide

marset
marset FUNICULI A Assembly instructions

Lighting Technologies
Lighting Technologies NBR 42 LED manual

Polarlite
Polarlite 1518441 operating instructions

Vista
Vista 7223 Landscape Series installation instructions

SERAX
SERAX Koen Van Guijze 15-03 BLACK instruction manual

Philips
Philips Ecomoods 16909/93/16 Specification sheet

GRUPO T DIFFUSION
GRUPO T DIFFUSION VIBIA Palo Alto 4525 Assembly instructions

Light Efficient Design
Light Efficient Design RemPhos RP-SSL-1W-40K-BK-GI user manual

LightPro
LightPro Opal Manual and safety instructions

Tracon
Tracon BL4008NW user manual

LIGMAN
LIGMAN CAPSULE 1 installation manual