SSS Siedle PUMA X User manual

REV.2016(08.08)
shown with optional transport kit
MODEL:PUMA X 3-SPEED AIR MOVER
VV78112TR
FORYOUR CONVENIENCE, RECORDTHEFOLLOWING
IMPORTANTINFORMATION
MODEL:
SERIALNUMBER:
DATE PURCHASED:
PURCHASEDFROM:

1
current warranty for this machine.
Please contact your Triple S Distributor for a copy of the
Warranty Information

2
FIGURE 2
FIGURE 1

3
FIGURE 3

4
FIGURE 4
1
2
3
456789
10
11
12
16
13
14
15
17

17 VV78406 ttt TRANSPORT KIT(OPTIONAL PART) 1
1/3HP Air Blower Specification(Figur7e 7 )7
5
PUMA X 120V 60 1 3HP 3.7 3.8 4.0 64 68 72 1000 1200 1400 2000 2200 2400 405X402X468 10
PUMA X Circuit Connection Diagram
pPUMA X PART LIST
(Figure6)
FIGURE 5
DIA NO PART NUMBER PART DISCRIPTION QTY
2 VV78106 FAN WHEEL KIT 1
4 VV78202 REAR RUBBER FOOT KIT 1
VV78203 KICK STAND 1
6 VV78204 FRONT SUPPORTING FOOT KIT 1
8 VV78206 WATERPROOF COVER KIT 1
10 VV78014 SOCKET 1
11 VV78210 3 SPEED CONTROL KNOB KIT 1
12 VV78211 3 SPPED SWITCH 1
13 VV78019 CIRCUIT BREAKER 1
16 VV78214 US POWER CORD 1
9
3
1 VV78200 MOTOR SIDE VENT COVER KIT 1
7 VV7820 FRONT OUTLET VENT KIT 1
VV78207 CONTROL PLATE KIT 1
14 VV78212 OUTER HOUSING KIT 1
1 VV78213 FAN WHEEL SIDE VENT COVER KIT 1
Air flow
110~120V
6 0 H z
S i n g le
P h a s e
P o w e r
S u p p ly
S J W 1 4 / 3 C P o w e r S u p p l y C o r d
W i r i n g D i a g r a m
B l a c k
G r e e n
W h i t e
R o t a r y
S w i t c h
O F F 1
2
3
. P .
C a p a c i t o r
C ir c u i t B r e a k e r
Model No. Voltage
(V) Frequency
(Hz) Power
(W) Amp Draw
(L M H)A
Sound
Level
(L M H)
dBA
Motor Speed
(L M H)
rpm ((L M H))
CFM
Shipping
Dimension
(mm)
Shipping
Weight
(kg)
VV78201 120V MOTOR ASSEMBLY KIT 1
7

6
SAFETY PRECAUTIONS
All operators shall read, understand and exercise the following safety precautions:
1) Do not operate machine:
Unless trained and authorized.
Unless you ha e read and understand the operators manual.
Inflammable or explosi e areas.
With a damaged cord or plug.
If not in proper operating condition.
In outdoor areas.
In standing water.
With the use of extension cords.
2) Before operating machine:
Make sure all safety de ices are in place and operate properly.
3) When using machine:
Do not pull machine by cord or plug.
Do not pull cord around sharp edges or corners.
Do not unplug machine by pulling on the cord.
Do not stretch cord.
Do not handle plug with wet hands.
Keep cord away from heated surfaces.
Report machine damage or faulty operation immediately.
4) Before lea ing or ser icing machine:
Turn off machine.
Unplug cord from outlet.
5) When ser icing machine:
An experienced technician should only perform ser ice work.
Unplug cord from outlet.
Use manufacturer supplied or appro ed replacement parts.
ENGLISH OPERATING INSTRUCTIONS

attachment plug to fit the proper grounding ty
type
5) To stop the machine at any time, simply turn the
4) This machine has 3 power settings. Turn the power
3) Plug power cord into a grounded outlet.
2) Adjust machine to desired position for operation
adjustments.(Air blower drying direction without Transport kit refer to
units to
1) Check the machine for any obstructions in fan pri
7
refer to .
work together on one circuit
Figure 2
)
Figure 1
GROUNDING INSTRUCTIONS
General – This air mo er shall be grounded while in use to protect the operator from electrical
shock. The machine is pro ided with a three – conductor cord and a three – contact grounding
pe receptacle.
The green (or green & yellow) conductor in the cord is the grounding wire. Ne er connect this wire to
anything other than the grounding pin of the attachment plug.
Make sure that all the safety functions are normal, and ensure that the actual operation oltage is in
accordance with the required oltage rate.Make sure that the machine is connected to an outlet
ha ing the same configuration as the plug. No adapter should be used with this machine.
This machine is intended for commercial use only. It is constructed for use in an indoor en ironment
and is not intended for any other use.
BASIC OPERATION
or to operation.
• If an item blocks the intakes of the air mo er, this will hurt the performance of the machine,
and could cause the motor to o erheat.
by pulling it back to its preset height
• Do not use an extension cord in conjunction with the standard power cord.
knob to the desired speed.
• Low = 1 Med = 2 High = 3.
power knob to the “off” position.
• Ne er stick any object into the air inlet ents or the air outlet ent.
DAISY CHAIN
The can be connected in a “Daisy Chain” allowing for two aditional
NOTE: The Air Mo er has an onboard circuit breaker. If the auxiliary outlet o erloads, the circuit
breaker will trip. If the breaker trips, unplug the units and press the circuit breaker reset button. Plug
the units back into the power source and turn on the switch.
ENGLISH OPERATING INSTRUCTIONS
PUMA X PUMA X

8
Figure 4+ 5
part list drawing refer to
Figure 7
Figure 6
Air blower specification refer to
refer to
MAINTENANCE
To keep this machine performing well for many years, please follow the following maintenance
procedures:
Always confirm he machine is unplugged from he power source prior o performing
any main enance or repairs!
1) Unplug machine as soon as you are done using it.
2) Check power cord for any damage. If any damage is detected, replace the cord immediately.
3) Lubricate the handle assembly and wheels with a water resistant lubricant e ery month.
4) Check machine for loose or missing nuts and bolts, and replace as necessary.
5) Clean the outside of the machine with a mild cleaner.
PART LIST
WIRING DIAGRAM
wiring diagram
AIR BLOWER SPECIFICATION
ENGLISH OPERATING INSTRUCTIONS
PUMA X
PUMA X
Table of contents
Popular Fan manuals by other brands

STIEBEL ELTRON
STIEBEL ELTRON LWZ 130 Operations & installation guide

Home Decorators Collection
Home Decorators Collection FREYTON 51503 Use and care guide

Hunter
Hunter 41835 Installation and operation manual

Termozeta
Termozeta WINDZETA 30 instruction manual

Casablanca
Casablanca 59021A Parts guide

PARMAIR EXIUS
PARMAIR EXIUS JrS TECHNICAL SPECIFICATIONS AND IMPLEMENTATION GUIDE

Monte Carlo Fan Company
Monte Carlo Fan Company 5VBR60 D Series owner's manual

Emerson
Emerson RAPHAEL CF2605PW00 owner's manual

Field Controls
Field Controls FIELD DIRECT VENT SYSTEM FDVS product manual

Outsunny
Outsunny 842-280V90 user manual

Midea
Midea FT30-16JB Service manual

Emerson
Emerson CF936GBZ00 owner's manual