Stern Foot Washfree Product manual

1
ELECTRONICLY OPERATED FOOT WASHER
Foot WashFree
Foot WashFree 3000
FOOTWASHFREE
FOOT WASHFREE 3000
InstallatIon and maIntenance guIde
ELECTRONICLY OPERATED FOOT WASHER

2 1
INDEX TEchNIcal DaTa
1 TECHNICAL DATA
2-3 PACK CONTENTS
4 PRE-INSTALLATION INFO
5-7 INSTALLATION
8-9 FLOW TIME ADJUSTMENT
9MAINTENANCE
Filters cleaning inructions
Care and cleaning of chrome and special nishes
10-11 BATTERY REPLACEMENT
11 SPARE PARTS LIST
12 WARRANTY
13 TROUBLE SHOOTING
FooT WashFrEE
FooT WashFrEE 3000
Product Control: Touch using Piezo technology
Minimum Operating Water
Pressure: 0.5 bar
Maximum Operating Water
Pressure: 8.0 bar
Max. Hot Water
Supply: 70° C
Power Specication: Internally mounted 9V Lithium battery
Default Flow Time: 8 seconds. Adjustable

2 3
Pack coNTENTs Pack coNTENTs
Familiarize yourself with the part names and conrm that the parts are included. Familiarize yourself with the parts names and conrm that the parts are included.
1 x body with regulating valve 1 x body with regulating valve and shower head
1 x wall flange with rubber seal
1 x wall flange with rubber seal
1 X Shower head
FOOT WASHFREE FOOT WASHFREE

4 5
PrE-INsTallaTIoN INFo
CHECK CONTENTS
Separate all parts from the packaging and check each part with the “Pack contents”
section.
Pay attention to the dierent models variations.
Make sure all parts are accounted for before discarding any packaging material.
If any parts are missing, do not attempt to inall your electronic faucet until you obtain the
missing parts.
WARNINGS
Do not inall facing a mirror or any other electronic syem operated by an infrared sensor.
To prevent reflection problems, it is recommended to keep a minimum distance of 1.50
meters between the faucet and any other objects.
PREPARATION FOR INSTALLATION
Flush water supply lines thoroughly before inalling the faucet. Do not allow dirt, Teon
tape or metal particles to enter the faucet.
Shut o water supply.
IMPORTANT
All plumbing is to be inalled in accordance with applicable codes and regulations.
INsTallaTIoN FOOT WASHFREE
sTEP 1- INsTallING ThE FooT WashEr
1Shut o the water supply.
2
Remove the hexagonal nut, the
disk and the gasket. Do not
remove the O-ring from the base of
the faucet.
3
Place the faucet with O-ring into
the hole in deck or lavatory. Make
sure the O-ring is located between
the deck or lavatory and the
bottom of the faucet.
4
Slide the gasket, disk and
hexagonal nut over the flexible
hose and secure the faucet into
place.
NOTE: If needed, cut the pipe to match the distance between the Alcala body
and the shower head.

6 7
INsTallaTIoN INsTallaTIoN
FOOT WASHFREE FOOT WASHFREE
sTEP 2 – coNNEcTING ThE WaTEr sUPPlY
1
Turn on the central water supply
and the shut-o valves and check
for leaks.
2
Ensure that the regulating valve
is fully open by turning it anti-
clockwise.
sTEP 1- INsTallING ThE FooT WashEr
1
Shut o the water supply.
2
Install the Foot WashfreeI on the wall
connected to the mains water
supply. Use sealing thread or
teflon tape to seal the screw
thread connection. Fit the
wall rosette between the inlet
opening of the regulating valve
and the surface of the wall.
sTEP 2 – coNNEcTING ThE WaTEr sUPPlY
1
Turn on the central water supply and
the shut-o valves (angle valves) and
check for leaks.
2
Ensure that the regulating valve
is fully open by turning it anti-
clockwise.

8 9
FloW TIME aDJUsTMENT FloW TIME aDJUsTMENT
ADJUSTMENT LEVELS
The flow time is programmable on site. If necessary, the default flow time of 8 seconds
can be adjusted to any value between 1 to 60 seconds. The Alcala adjustment mechanism
is composed of 3 adjustment levels for changing the flow time. An indicator light (LED)
will guide you from one level to the other.
The following table shows the number of steps in each level, the duration of each step
and how to recognize in what adjusting level you are.
HOW TO ADJUST THE FLOW TIME IN ALCALA
1) Open the piezo cap using the provided 2 mm Allen key.
2) Disconnect the internal battery.
3) Touch the piezo cap twice.
4) Then, reconnect the battery.
5) The indicator light (LED) on the back of the Piezo cap will start blinking. Aer a few
blinks the LED will give a steady red light. Touch the Piezo cap when the steady red light is
still on to enter into the adjusting mode. When done correctly, the light will stop blinking.
NOTE: If you will not press at the indicated area, the previous adjustment will remain.
6) By touching the Piezo cap the new flow time will be programmed.
In adjusting mode level 1, each touch increases the flow time by 1 second with a maxi-
mum of 10 seconds. You will see the LED blinking every time
that a new step is performed.
7) If your desired flow time is within 10 seconds, no other adjusting levels are needed and
you can stop pressing the Piezo cap. The LED will blink 2 times, then 3 times and aer 4
times you will leave the adjusting mode.
The Foot Washfrees now adjusted to the desired flow time.
8) If you need to perform steps at adjusting level 2, wait until you see
the LED blink twice and then, perform the needed quantity of steps (with a maximum of
steps of seconds).
If you do not need more levels, stop pressing. The indicator light will blink
3 times and aer 4 times you will leave the adjusting mode. The Alcala is now adjusted to
the desired flow time.
9) If you need to perform steps at adjusting level 3, wait until you see the LED blink 3
times and then, perform the needed quantity of steps (with a maximum of 2 steps of 15
seconds).
10) To leave the adjusting mode wait until the LED blinks 4 times.
The Foot Washfrees now adjusted to the desired flow time.
Level 1 Level 2 Level 3 Out of
adjusting mode
No. of steps 10 steps 10 steps 2 steps
Seconds to be
increased by
touching once
1 second 2 seconds 15 seconds
Adjustment
level indicator
After entering
into adjusting
mode level 1 is
reached
Indicator light
blinks twice
Indicator
light blinks
3 times
Indicator light blinks
4 times
MaINTENaNcE
FILTER CLEANING INSTRUCTIONS
The system is provided with two stainless steel lters preventing foreign particles to enter
the lines. If the water flow has decreased, this may be because the lters are clogged. The
lters can be cleaned as follows:
1. Shut-o the water shut o valve.
2. Disassemble the Alcala, and remove the lter located between the body and the shut
o valve.
3. Wash the lter under running water.
4. Reassemble the parts.
5. Make sure that there is no water leakage.
CARE AND CLEANING OF CHROME AND SPECIAL FINISHES
DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the
like. Use of any prohibited cleaning or maintenance products or substances could dam-
age the surface of the faucet.
For surface cleaning of faucets use ONLY soap and water, then wipe dry with clean cloth or
towel. When cleaning bathroom tile, the faucets should be protected from any splattering
of harsh cleansers.

10 11
BaTTErY rEPlacEMENT
LOW BATTERY INDICATOR
Alcala has an advanced battery level management system consisting of two steps. In the rst step,
the battery still has enough power to open and close the solenoid valve and allows the solenoid
valve to open.
In the second step the battery might not have enough power to open and close the solenoid valve.
In this case, the battery level management system does not allow the solenoid valve to open.
Instead of providing an opening and closing pulse, the systems provides two closing pulses.
BaTTErY rEPlacEMENT INsTrUcTIoN
1
Unscrew the M4X4 Allen screw
on the Alcala cap and pull out the
piezo cap.
2Disconnect the connectors and take
out the old battery.
3
Replace the used battery with a
new 9V battery. A lithium battery is
recommended.
4Reconnect the connectors between
the battery and Piezo cap.
5Place the Piezo cap back into place
and tighten the Allen screw.
NOTE:
· Do not allow moisture or water into the system while the battery is being replaced.
· The interior of the shower control must be fully dry before reassembling the parts. If it is not fully
dry, carefully dry it.
NEW
BATTERY
FOOT WASHFREE:
FOOT WASHFREE :
sParE ParTs lIsT
SEALS AND SCREWS KIT
FILTER
COVER KIT
SOLENOID VALVE KIT
SPRAY PLATE+SCREW KIT
SEALS AND SCREWS KIT
FILTER & RESTRICTOR KIT
COVER KIT
SOLENOID VALVE KIT
SPRAY PLATE+SCREW KIT

12 13
sErVIcE chEck lIsT
Check the battery. Low or used up
battery. Replace the battery. See page 10
Check the flow time. See page 8.
Check the connection between the
piezo cap connector and the solenoid
connector.
Check the solenoid valve. If debris or
scale are present, unscrew the solenoid
valve, pull out the plunger and the spring
and clean them.
Use scale remover if needed. When
replacing the spring, make sure that it is
in vertical position.
Check the diaphragm. If needed, clean
the orifice or replace it.
Check the water supply pressure. It must
be 0.5-8.0 bar (7-116 PSI) . With water
pressure of more than 8 Bars, use a
pressure reducing valve.
No water is coming out
Water flow does not stop
Water flow diminished Check the filter. If needed, remove it,
clean it and reinstall it. See page 8.
Check the flow time. If needed adjust it
following the instructions at page 10.
Check the solenoid valve. If debris or
scale is present, unscrew the solenoid
valve, pull out the plunger and the spring
and clean them.
Use scale remover if needed. When
replacing the spring, make sure that it is
in vertical position.
WarraNTY
Y. Stern Engineering Ltd. warrants that its electronic faucets, flush valves and controls will
be free of defects in material and workmanship during normal use for two years from the
date the product is purchased.
If a defect is found in normal use, Y. Stern Engineering Ltd. will, at its discretion, repair,
provide a replacement part or product, or make appropriate adjustments. Damage caused
by accident, misuse, or abuse is not covered by this warranty. Improper care and cleaning
will void the warranty. Proof of purchase (original sales receipt) must be provided to Stern
Engineering Ltd. with all warranty claims.
Stern Engineering Ltd is not responsible for labor charges, installation, or other incidental
or consequential costs other than those noted above. In no event shall the liability of
Stern Engineering Ltd. exceed the purchase price of the faucet, valve or control.
If you believe that you have a warranty claim, contact your Stern Distributor, Dealer or
Plumbing Contractor. Please be sure to provide all pertinent information regarding your
claim, including a complete description of the problem, the product, model number,
the date the product was purchased, from whom the product was purchased and the
installation date. Also include your original invoice.
Y. STERN ENGINEERING AND/OR SELLER DISCLAIM ANY LIABILITY FOR SPECIAL,
INCIDENTAL OR CONSEQUENTIAL DAMAGES. This warranty excludes product damage due
to installation error, incorrect maintenance, wear and tear, battery, water composition,
product abuse, or product misuse, whether performed by a contractor, service company,
or the consumer. This warranty does not cover product damage caused by the following:
- Incorrect installation, inversions of supply pipes.
- Pressures or temperatures exceeding recommended limits.
- Improper manipulation, tampering, bad or lapsed maintenance.
- Foreign bodies, dirt or scale introduced by the water supply.

14
.
Passaic Avenue, Clifton NJ,, USA
Tel: + |Fax: +
Toll Free:
info@sternfaucets.com | sternusa@sternfaucets.com
This manual suits for next models
3
Table of contents
Popular Washer manuals by other brands

Siemens
Siemens WM14UQ92GB User manual and installation instructions

Midea
Midea MAH180-A2801PS/01FM-US Service manual

VESTEL
VESTEL CME-M 6108 T user manual

Electrolux
Electrolux EWT 1066 TDW Installation instruction

Asko
Asko PROFESSIONAL WMC844V operating instructions

Grundig
Grundig GW5P582210X user manual