Supco WA412YRE User manual

WINDOW
AIR CONDITIONER
USER MANUAL
950-0215 3/6/2014
FOR MODELS:
COOLING CAPACITY
WA412YRE
12,000 BTU
WA412ZRE
12,000 BTU

Page 1
CONTENTS
INSTALLATION REQUIREMENTS............................................................................................................................2
Tools and Parts..................................................................................................................................................2
Location Requirements......................................................................................................................................3
Electrical Requirements.....................................................................................................................................4
INSTALLATION INSTRUCTIONS..............................................................................................................................5
Remove packaging materials............................................................................................................................5
Prepare Your Unit ..............................................................................................................................................5
Install Your Air Conditioner in the Window ........................................................................................................6
Install the Support Bracket and Seal the Window.............................................................................................7
AIR CONDITIONER CONTROLS (Panel).................................................................................................................8
Air Conditioner Controls ....................................................................................................................................9
REMOTE CONTROL...............................................................................................................................................13
Function buttons..............................................................................................................................................14
Remote Operation ...........................................................................................................................................15
IMPORTANT INFORMATION..................................................................................................................................18
3 minutes delay................................................................................................................................................18
Select
℉
or
℃
.................................................................................................................................................18
Fresh Air Vent Control .....................................................................................................................................18
Air Directional Louvers.....................................................................................................................................19
Normal Sounds................................................................................................................................................19
AIR CONDITIONER CARE......................................................................................................................................20
Cleaning the Air Filter......................................................................................................................................20
Cleaning the Front Panel.................................................................................................................................20
Repairing Paint Damage of Outside Case ......................................................................................................20
Annual Maintenance........................................................................................................................................20
TROUBLESHOOTING.............................................................................................................................................21
SPECIFICATIONS ...................................................................................................................................................23
WARRANTY.............................................................................................................................................................24
FOREWORD
The appearance of the units that you purchase may be slightly different from the ones described in this manual,
but will not affect proper operations and usage.
Please read carefully the sections corresponding to the specific model you have, and keep the manual in a safe
place for reference.
The refrigerant used in your portable air conditioner is environmentally safe.
ATTENTION
Keep small children away from portable unit.
Do not modify or otherwise defeat the plug.
The appliance shall be installed and operated in accordance with National Electrical Code regulations.
Do not operate the machine when the ambient temperature is below 64°F or above 109°F .
If the supply cord is damaged, it must be replaced by a qualified person in order to avoid a fire hazard.
All electrical repairs and connections must be performed by a licensed electrician.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic
precautions:
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Unplug air conditioner before servicing.
Use two or more people to move and install air
conditioner.
Do not operate this unit if the outdoor
temperature is below 64°F.

Page 2
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed here.
Tools Required
Phillips head screwdriver
Flat-blade screwdriver
Pencil
Ruler or tape measure
Level
Scissors or Utility knife
Parts Supplied

Page 3
Location Requirements
IMPORTANT: Observe all governing codes and
ordinances.
Check the location where air conditioner will be
installed. Proper installation is your responsibility.
Make sure you have everything necessary for
correct installation.
The location should provide:
Grounded electrical outlet within 6 ft of
where the power cord exits the air
conditioner.
NOTE: Do not use an extension cord.
Free movement of air in room to be cooled.
A large enough opening for the air
conditioner.
Adequate wall support for weight of air
conditioner. Air conditioner weights up to 70
lbs.
NOTE: Cabinet louvers & rear of the air
conditioner must not be obstructed. Air must be
able to pass freely through the cabinet louvers.
The rear of air conditioner must be outdoors. Not
inside a building or garage.
Window Requirements:
These instructions are for
a standard double hung
window. You will need to
modify them for other
types of windows.
The air conditioner can be
installed without the
accordion panel if needed
to fit in a narrow window.
See Window Opening
dimensions.
All supporting parts must be secured to firm
wood, masonry or metal.
Follow the dimension in TABLE -1.
Models/Cooling
Capacity
Dim. A –
Opening Width
Dim. B - Min
Vertical Opening
12,000
23”-36”
15 1/2”
TABLE -1
Thru the Wall Installation Requirements:
The air conditioner can be thru the wall installed.
The side louvers must never be blocked.
Table -2 provides the maximum wall thickness
dimension from the outer case to side air louvers.
Models/Cooling
Capacity
Front Cover to
Side Vent
Unit Depth
12,000
8”
21.5”
TABLE -2
Storm Window Requirements:
A storm window frame will not allow the air
conditioner to tilt properly which in turn will keep
it from draining properly. To adjust for this,
attach a board or piece of wood to the sill. The
board or wood piece should have a depth of at
least 1 1/2”. Make sure the board or piece of
wood is approximately 1/2” higher than the
storm window frame. This will allow the air
conditioner to tilt enough for proper drainage.
See FIG-1.
FIG-1

Page 4
Electrical Requirements
LCDI TYPE
Wiring Requirements
NEMA 5-15P
115-Volt (103.5 min to
126.5 max.)
0 to 13amps
15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit
only.
NEMA 6-15P
230-Volt (198 min to 253
max.)
0 to 12 amps
15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit
only.
TABLE - 3
Recommended Grounding Method
This air conditioner must be grounded. This air
conditioner is equipped with a power supply cord
having a grounded 3 prong plug. To minimize
possible shock hazard, the cord must be
plugged into a mating, grounded 3 prong outlet,
grounded in accordance with all local and
national codes. If a mating outlet is not available,
it is the customer’s responsibility to have a
properly grounded 3 prong outlet installed by a
qualified electrical installer.
It is the customer’s responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation
is adequate and in conformance with
National Electrical Code, ANSI/NFPA
70- latest edition, and all local codes
and ordinances.
Power Supply Cord
NOTE: Your unit’s device may differ from the
ones shown.
This room air conditioner is equipped with a
power supply cord required by UL. This power
supply cord contains state-of-the-art electronics
that sense leakage current. If he cord is crushed,
the electronics detect leakage current and power
will be disconnected in a fraction of a second.
To Test your power supply cord:
1. Plug power supply cord into a grounded 3
prong outlet.
2. Press RESET
3. Press TEST (listen for click, Reset button
will trip and pop out).
4. Press and release RESET (listen for click;
Reset button will latch and remain in). The
power supply cord is ready for operation.
NOTES:
The reset button must be pushed in for
proper operation.
The power supply cord must be replaced if it
fails to trip when the test button is pressed
or fails to reset.
Do not use the power supply cord as an
off/on switch. The power supply cord is
designed as a protective device.
A damaged power supply cord must be
replaced with a new power supply cord
obtained from the product manufacturer and
must not be repaired.
The power supply cord contains no user
serviceable parts. Opening the tamper-
resistant case voids all warranty and
performance claims.

Page 5
INSTALLATION INSTRUCTIONS
Remove packaging materials
Remove and dispose of/recycle packaging
materials. Remove tape and glue residue
from surfaces before turning on the air
conditioner. Rub a small amount of liquid
dish soap over the adhesive with your
fingers. Wipe with warm water and dry.
Do not use sharp instruments, rubbing
alcohol, flammable fluids, or abrasive
cleaners to remove tape or glue. These
products can damage the surface of your air
conditioner.
Handle air conditioner gently.
Prepare Your Unit
Install the Top Mounting Rail
Locate provided bag of screws.
Place top mounting rail on top of air
conditioner, lining up the 4 holes in rail with
the 4 holes on top of air conditioner.
Using 4 screws, attach top mounting rail to
air conditioner.
NOTE: Your unit may have top rail preinstalled,
skip this step if it is installed.
NOTE: Your units
may have the seal
strip already attached
to the top mounting
rail. If applicable, skip
this step.
Attach the rail seal
strip
Remove the backing
from the top
mounting rail seal
strip and attach the seal strip to the bottom of
the top mounting rail, along the front edge.

Page 6
Install the Accordion Panel
Hold the accordion panel in one hand and
gently pull back to free the open end.
Slide the free end and (I section) of the
accordion panel into the cabinet as shown in
Fig 2. Slide the panel down. Be sure to
leave enough space to slip the top and
bottom of the frame into the rails on the
cabinet.
NOTE:
There is a right and a left accordion panel. Be
sure to use the proper panel for each side.
Once the panel has been installed on the
side of the cabinet, make sure it sits
securely inside the frame channel by making
slight adjustments. Slide the top and bottom
ends of the frame into the top and bottom
rails of the cabinet. See Fig.3.
Slide the panel all the way in and repeat on
the other side.
Install Your Air Conditioner in the
Window
Handle air conditioner gently.
Be sure your air conditioner does not fall out
of the opening during installation or removal.
The place where the power cord exits the air
conditioner should be no more than 6 ft (182
cm) from a grounded 3 prong outlet.
Do not block the louvers on the front panel.
Do not block the louvers on the outside of
the air conditioner.
FIG.1
FIG.2
FIG.3
FIG.4

Page 7
Install Your Unit
Center the air conditioner in window. Check
that lower rail of air conditioner is behind
and against back side of window sill.
Maintain a firm hold on the air conditioner
cabinet. Lower window sash to hold cabinet
in place.
Measure the distance between the right-
hand side of the cabinet and the inside of
the window channel.
Repeat for the left side. Adjust the cabinet
until the distance on each side is the same.
Extend the left and right accordion panels to
the vertical window sashes and use the
screws to attach.
Install the frame locking brackets between
the bottom of the accordion panel and the
window sill. Attach with 2 screws.
To prevent the window sill from splitting,
drive the pilot holes before driving screws.
Check that air conditioner cabinet is tilted to
the outside so that water will run to the
outside.
Install the Support Bracket and Seal the
Window
CAUTION:
To prevent broken glass or damage to windows,
on vinyl or other similarly constructed windows,
attach the window locking bracket to the window
side jamb with one screw.
Attach the right angel sash lock with screw
as shown below.
Cut the foam top window gasket to the
window width.
Stuff the foam between the glass and the
window to prevent air and insects from
getting into the room.
If the gasket supplied does not fit the window,
obtain appropriate material locally to provide a
proper installation seal.

Page 8
AIR CONDITIONER CONTROLS (Panel)
Before you begin, thoroughly familiarize yourself with the control panel and remote as shown below and all its
functions then follow the symbol for the functions you desire. The air conditioner can be controlled by the remote or the
control panel.
Unit Control Panel

Page 9
Air Conditioner Controls
TO TURN UNIT ON:
TO CHANGE TEMPERATURE SETTING:
TO ADJUST FAN SPEED:
Change Temperature:
Press or hold either Left (<)
or Right (>) button until the
desired temperature is seen
on the display.
Temperature range is 62°F
(17°C) to 86°F (30°C) in 1°F
(1°C) increments.
Display indicates set
temperature in all modes
except "FAN ONLY" mode.
Select Fan Speed:
Used to select the Fan Speed
oAuto
oLow
oMedium
oHigh
Each time the button is
pressed the fan speed is
shifted.
If the DRY mode is selected
the fan will operate in LOW
speed.
Press button to turn unit on or off.

Page 10
Air Conditioner Controls (Cont.)
TO SELECT THE OPERATING MODE:
TO USE THE ENERGY SAVER MODE:
Select Operating Mode:
To choose operating mode, press the Mode button.
Each time you press the button, a mode is selected
in a sequence that goes from Auto, Cool, Dry and
Fan. The indicator light above the Mode Button will
be illuminated.
To Operate Cooling Mode:
Press the MODE button to select Cool mode,
temperature could be set between 62 ºF and 86 ºF
in 1 ºF increments
In cooling mode, the FAN-AUTO function can be
selected, automatically changing the fan speed as
the room temperature gets closer to set point.
To Operate Auto Mode:
When the "AUTO" function is selected, it will
automatically select the cooling or fan function. The
set temperature can be selected as desired. The
temperature range is 62°F to 86°F.
The air conditioner will control room temperature
automatically around the temperature set point.
In the "AUTO" mode, the fan speed is not
selectable. The fan will change speeds according to
the room temperature and the set point.
If "AUTO" mode is not comfortable, select another
mode.
To Operate Fan Only Mode:
Use this function only when cooling is not desired
such as for room air circulation or to exhaust stale
air. Open the outside vent for maximum circulation.
The outside vent should be closed for all other
modes (Cooling, Auto and Dry). Fan speed is
selectable (Auto, Low, Med, and High).
The FAN ONLY function will display the actual room
temperature.
In other modes the set point is displayed.
In Fan only mode, the temperature is not adjustable.
If the Fan-Auto is selected, the temperature is
automatically set to 75 °F . The fan speed will
decrease as the room temperature approaches set
point.
To Operate Dry Mode:
The air conditioner will operate in the form of a
dehumidifier. Since the conditioned space is a
closed or sealed area, some degree of cooling will
continue.
Energy Saver Mode:
This function is available in COOL/DRY/AUTO
mode. The fan will continue to run for 3 minutes
after the compressor shuts off. The fan then cycles
on for 2 minutes at 10 minute intervals. If the room
temperature goes above the set point, the
compressor turns on and begins to cool.
Press the temperature UP/DOWN buttons to select
the desired set temperature. The temperature range
is 62°F to 86°F.
The fan speed is selectable in the Energy Saver
mode.

Page 11
Air Conditioner Controls (Cont.)
SLEEP MODE:
TIMER: AUTO START/STOP FEATURE:
SLEEP MODE:
The temperature setting will increase by 2 °F in 30 minutes. In
another 30 minutes the temperature setting will increase by
another 2 °F.
This temperature will be maintained for 6 hours and then the
temperature will return to the original set point temperature.
To cancel the sleep mode, press the "Sleep" button.
TIMER ON / TIMER OFF:
Press the Timer button to select "On or Off". After the
time is selected the unit will either turn on or off after the
timer has timed out.
Example:
If the unit is operating and "OFF' is selected the unit will
turn off after the selected time times out.
If the unit is off and "On" is selected the unit will turn on
after the selected times out.
Press or hold the UP or DOWN button to change the
Auto time by 0.5 hour increments up to 10 hours, then at
1 hour increments up to 24 hours. The control will count
down the time remaining until the unit starts or stops.
The selected time will update in 5 seconds. The system
will automatically revert back to display the previous
temperature setting or room temperature when the unit is
on. (When the unit is off, there is no display.)
Turning the unit ON or OFF at any time or adjusting the
timer setting to 0.0 will cancel the Auto Start/Stop timed
program.

Page 12
Air Conditioner Controls (Cont.)
CHECK FILTER FEATURE:
DISPLAYS:
CHECK FILTER FEATURE:
This feature is a reminder to clean the Air Filter for more
efficient operation. The LED (light) will illuminate after 250
hours of operation. To reset after cleaning the filter, press
the Check Filter button and the light will turn off.
DISPLAY INDICATIONS:
Displays the following possibilities:
* °F or °C
* Timer setting
* Set temperature (all modes other than fan).
* Room temperature in the fan mode
* Error codes
Error codes:
1) AS - Room temperature sensor error. Unplug the
unit and plug it back in. If error repeats, call for
service.
2) LO or HI –(Fan Only Mode) Room temperature
sensor error. Unplug the unit and plug it back in. If
error repeats, call for service.
3) “·”(see picture to the left) - Evaporator
temperature sensor error. Unplug the unit and plug
it back in. If error repeats, call for service.
4) HS -Electric heating sensor error. Unplug the unit
and plug it back in. If error repeats, call for service.

Page 13
REMOTE CONTROL
Handling and location of the remote controller
Use the remote controller at a distance of 16 ft., or less, from the appliance. Point it towards the receiver on the air conditioner.
Communication is confirmed with a beep.
CAUTIONS
The air conditioner will not operate if curtains, doors or other materials block the signal from the remote control to the air
conditioner.
Avoid
oLiquids
oDirect Sunlight
oExtreme Temperatures
If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly.
If other electrical appliances react to the remote controller, either move these appliances or consult your local dealer.
Replacing Batteries
The remote control is powered by two AAA alkaline batteries housed in the back of the remote. (Do not use rechargeable batteries)
(1) Remove the cover by pressing down and sliding back.
(2) Remove the old batteries and insert the new batteries, observing polarity.
(3) Replace the battery cover.
NOTE: When the batteries are removed, the remote control erases all settings. After inserting new batteries, the remote controller
settings must be selected.
Remote Control Specifications
Rated Voltage
3.0V
Lowest Voltage of CPU
Emitting Signal
2.4V
Signal Receiving Range
16 ft
Environment
23-140︒F
1) The remote control is a sending device only. The display on the control panel of the air
conditioner will indicate changes made by the remote control.
2) The illustrations in this manual are for explanation purposes only. The actual shape of remote
controller may be slightly different.

Page 14
Function buttons
ON/OFF button
Operation starts when this
button is pressed and
stops when it is pressed
again.
TEMP / TIME UP
button
Push this button to
increase the temperature
setting in 1 ºF increments.
Temperature range is 62 ºF
to 86 ºF.
Adjust the time setting.
TIMER button
Push this button to
activate the “Auto Start”
or “Auto Stop” program.
ONE TOUCH button
Push this button; the system will
automatically shift to COOL
Operation with auto fan speed, the
setting temperature is 80°F . And
the timer setting program will be
cancelled.
SLEEP button
Press this button to
activate the Sleep mode.
This function is available
on COOL, HEAT or AUTO
mode only.
FAN button
Used to select the fan
speed in four steps: Auto,
Low, Med and High.
TEMP / TIME DOWN
button
Push this button to decrease the
indoor temperature setting in 1 ºF
increments. Temperature range
is 62 ºF to 86 ºF.
Adjust the time setting.
MODE button
Press this button to select
the desired operation mode
from AUTO, COOL, DRY,
and FAN.

Page 15
Remote Operation
Press to turn unit ON/OFF
Auto operation
1. Press the ON/OFF button to start the air conditioner.
2. Press the MODE button to select Auto. The panel
"AUTO" LED will illuminate when selected.
3. Press the TEMP UP/DOWN button to set the
desired temperature. The temperature range is 62 ºF -
86 ºF in 1 ºF increments.
NOTE:
1. In the Auto mode the air conditioner will select
Cooling or Fan depending upon set point vs. room
temperature.
2. In the Auto mode, you cannot switch the fan
speed. It is automatically controlled.
3. If the Auto mode is not comfortable select another
mode for manual operation.
ONE TOUCH button
4. Push this button; the system will automatically shift
to COOL Operation with auto fan speed, the setting
temperature is 80°F . And the timer setting program will
be cancelled.
Cooling/Fan operation
1. Press the ON/OFF button to start the air conditioner.
2. Press the MODE button to select Cool or Fan mode. The
panel "Cool" or “Fan” LED will illuminate when selected.
3. Press the TEMP UP/DOWN button to set the
desired temperature. The temperature can be set within the
range of 62 ºF - 86 ºF in 1 ºF increments.
4. If cooling is selected, the FAN-AUTO function can be
selected, automatically changing the fan speed as the room
temperature gets closer to set point. The panel “Fan-Auto"
LED will illuminate when selected.
5. Press the FAN button to select the fan speed in four steps
- Auto, Low, Med, or High.
6. In the FAN mode, actual room temperature is displayed in
the control panel. If the Fan-Auto is selected, the
temperature is automatically set to 75 °F. The fan speed will
decrease as the room temperature approaches set point.

Page 16
Remote Operation (cont.)
Dehumidifying (DRY) operation
1. Press the ON/OFF button to start the air conditioner.
2. Press the MODE button to select DRY. The panel "DRY"
LED will illuminate when selected.
3. Press the TEMP UP/DOWN button to set the desired
temperature. The temperature can be set within a range of
62 ºF - 86 ºF in 1 ºF increments.
NOTE:
In the Dehumidifying mode, you can not change the fan speed. It is
controlled in low speed.
SLEEP operation
Press this button to activate the SLEEP mode. This function is
available on COOL or AUTO mode only and maintains the most
comfortable temperature for you. The panel "SLEEP" LED will
illuminate when selected.
In this mode the selected temperature will increase by 2 ºF in 30
minutes after the mode is selected. The temperature will then
increase by another 2 ºF after an additional 30 minutes. This
new temperature will be maintained for 6 hours before it returns
to the originally selected temperature.
This ends the SLEEP mode and the unit will continue to operate
as originally programmed.
The SLEEP mode program may be cancelled by pressing the
MODE, ON/OFF, FAN SPEED and SLEEP button during
operation.

Page 17
Remote Operation (cont.)
Timer operation (Combined)
(Setting both ON and OFF timers simultaneously)
AUTO STOP-> AUTO START
(On-> Stop ->Start operation)
This feature is useful when you want to stop the air conditioner after you go to
bed, and start it again in the morning when you wake up or when you return
home.
Example:
To stop the air conditioner 2 hours after setting and start it again 10 hours after
setting.
1. Press the TIMER button until the TIMER OFF indicator is displayed on the
LED display of the air conditioner.
2. Use the UP/DOWN button to display “2.0” on the LED display.
3. Press the TIMER button again to display the TIMER OFF
4. Use the UP/DOWN button to display “10”.
5. Wait for 5 seconds until the previous display revert back to the LED window.
AUTO START -> AUTO STOP
(Off ->Start->Stop operation)
This feature is useful when you want to start the air conditioner before you wake
up and stop it after you leave the house.
Example:
To start the air conditioner 5 hours after setting, and stopping it 8 hours later.
1. Press the TIMER button until the TIMER ON indicator is displayed.
2. Use the UP/DOWN button to display “5.0”.
3. Press the TIMER button again to display the TIMER OFF.
4. Use the UP/DOWN button to display “8.0”.
5. Wait for 5 seconds until the previous display reverts back to the LED
window.
Timer operation
Press the TIMER button to initiate the Auto-start and Auto-stop
setting program of the unit. The time can be set for 0~24 hours.
To set the Auto-start/stop time.
1. Press the TIMER button, when the TIMER ON indicator
displayed on the LED window of the air conditioner, it indicates
the Auto Start setting program is initiated. When the TIMER OFF
indicator displayed on the LED window of the air conditioner, it
indicates the Auto Stop setting program is initiated.
2. Press or hold the Up(▲) or Down(▼) to change the Auto
time by 0.5 hour increments up to 10 hours, then at 1 hour
increments up to 24 hours. The control will count down the time
remaining until starts/stops.
3. The selected time will register in 5 seconds and the air
conditioner will automatically revert back to display the previous
temperature setting.
4. Turning the unit ON or OFF at any time will cancel the Auto
start/stop function.
5. To cancel the TIMER setting, push the TIMER button and
press or hold the Up (▲) or Down (▼) until 0 hour is displayed
on the LCD window of the air conditioner

Page 18
IMPORTANT INFORMATION
3 minutes delay
The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents
overheating of the compressor and possible circuit breaker tripping. The fan will continue to run during this time.
Select
℉
or
℃
The unit is shipped in degree F as the default indication.
The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert from one to the
other, press and hold the UP and DOWN temperature (Timer) buttons on control panel simultaneously for 3 seconds.
Fresh Air Vent Control
Fig 1 (VENT CLOSED)
Fig 2 (VENT OPEN) Fig 3 (VENT & EXHAUST OPEN)
The Fresh Air Vent allows the air conditioner to:
1. Recirculate inside air - Vent Closed (See Fig.1)
2. Draw fresh air into the room- Vent Open (see Fig.2)
3. Exchange air from the room and draws fresh air into the
room - Vent and Exhaust Open (see Fig.3)

Page 19
Air Directional Louvers
Air Direction
Normal Sounds
When your air conditioner is operating normally, you may hear sounds such as:
Droplets of water hitting the condenser, causing a pinging or clicking sound. The water droplets help to cool
the condenser.
Air movement, for improved operation.
Clicks from the thermostat cycling.
Vibrations or noise due to poor wall or window construction.
A high-pitched hum or pulsating noise caused by the modern high-efficiency compressor cycling on and off.
The louvers will allow you to direct the air flow Up or
Down (on some models) and Left or Right
throughout the room as needed. Pivot horizontal
louvers until the desired Up/Down direction is
obtained.
Move the Levers from side to side until the desired
Left/Right direction is obtained.
This manual suits for next models
1
Table of contents
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual