T&M Performance PROJECT60 User manual

Please follow the instructions in this manual to obtain the optimum resultsfrom this unit.
We also recommend that you keep this manual handyfor future reference.
OPERATION MANUAL
POWER
OUTPUT LEVEL
TAPE
CD
TUNERLINE
PROJECT60
MIC 1 MIC 2 MIC 3 MIC 4 BASS TREBLE
AUX MASTER
0
-12 +12
0
-12 +12
PROJECT60
PROJECT120

TABLE OFCONTENTS
2
1. SAFETYPRECAUTIONS .......................................................................................3
2. GENERALDESCRIPTION ....................................................................................5
3. FEATURES ...............................................................................................................5
4. NOMENCLATUREAND FUNCTIONS
4.1 Front Panel.............................................................................................................6
4.2 RearPanel............................................................................................................. 7
5. CONNECTIONS
5.1. SpeakerConnections ............................................................................................8
5.2. XLR Connections ..................................................................................................8
6. ........................................................................................9
7. APPLICATIONS ......................................................................................................10
8.SPECIFICATIONS ................................................................................................. 11
9.DIMENSIONAL DIAGRAM ....................................................................................13
MACHINE OPERATION
V1.0-2009-11-26
Project60/Project120

Be sure to read the instructions in this sectioncarefully before use.
Make sure to observe the instructions inthis manual as the conventions of safety symbols andmessages
regarded as very important precautions are included.
We also recommend you keep this instructionmanual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground to a
gas pipe as a catastrophic disaster may result.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
When the Unit is in Use
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest dealer. Make
no further attempt to operate the unit in this condition
as this may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest dealer.
t&mSystems
t&mSystems
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
3
1. SAFETY PRECAUTIONS
Project60/Project120

An all-pole mainsswitch with acontact separation ofat least 3mm in eachpole shall beincorporated in
the electrical installationof the building.
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so maycause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.
Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your dealer as to the cleaning.
If dust is allowed toaccumulate in the unit over
a long periodof time,a fire or damage to the
unit may result.
t&mSystems
If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.
Switchoff the power,and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unusedfor 10 daysor
more.Doingotherwise may cause a fire or electric
shock.
1. SAFETY PRECAUTIONS
4
Project60/Project120

5
3. FEATURES
t&mSystems series of public address mixer amplifiers have power ratings from 60 to 120 watts RMS, these
sleek, attractive units provide a compact solution for PAsystem amplification and distribution.
2. GENERAL DESCRIPTION
=.
=
=.
=
=
=.
=.
=.
=
=
=
=.
=
=
Rated power:60W/120W
AC and DC operation
Special Low Cut filter built-in
Level meter and power indicator
Phoenix connector for easy installation
4 Aux input, with inter-lock to avoid blending
Built-in 2 tone and 4 tone chime two options
Pre OUT for other signal processing equipments
Individual input volume and master volume control
Current limiter, overloading, short circuit and thermal protection
With remote priority input to select background music when paging
4 balanced XLR mic input with selectable priority and each with phantom power
Constant voltage 100V and 70V and 50V lines and low impedance 4 ohms speaker terminal
Constant voltage 100V and 70V and 50V lines and low impedance 4 ohms speaker terminal 3. 4
Aux input, with inter-lock to avoid blending
.
..
...
Project60/Project120

6
1. MIC1 \ MIC2 \ MIC3 \ MIC4
MIC volume control (MIC1/MIC2/MIC3/MIC4)
2. AUX
AUX volume control
3. BASS
Adjust bass response. Rotate clockwise to increase
bass output and anticlockwise to reduce it.
4. TREBLE
Adjust treble response. Rotate clockwise to increase
treble output and anticlockwise to reduce it.
5. MASTER
control
6. POWER SWITCH
On top of the opening Power
Press the end, power shut down
Master volume
4. NOMENCLATUREAND FUNCTIONS
1
7. ON
Protection indicator
8. OUTPUT LEVEL
9. TAPE
Select tape channel input keyswitch
10.CD
Select CD channel input keyswitch
11.TUNER
Select tuner channel input keyswitch
12.LINE
Select line channel input keyswitch
Power level indicator
26
4.1 FRONT PANEL
45
37
89
101112
Project60/Project120
PROJECT60
TAPE
CD
TUNERLINE
MIC 1 MIC 2 MIC 3 MIC 4 BASS TREBLEAUX MASTER
OUTPUT LEVEL
POWER
0
-12 +12
0
-12 +12

GAIN GAIN GAIN GAIN
MICRO1 MICRO 2 MICRO3 MICRO4 TAPE CD TUNER LINE REC PREOUT
POWERIN
OUT
POWEROUT
100V
70V
50V
4
COM
XLRBAL
1-GND
2-HOT+
3-COLD-
11
2233
PHANTOM MIC
PHANTOM MIC
PHANTOM MIC
PHANTOM MIC
VOLUME
CHIME
CHIME REMOTE
MIC1MIC1 MIC2MIC2 MIC3MIC3 MIC4MIC4
ONON
OFFOFF
ONON
OFFOFF
ONON
OFFOFF
ONON
OFFOFF
MICPRIORITYMICPRIORITY 2T 4T
1234
ON
CHIME
BATTSUPPLY
+ DC24V -
T2AL250V
230V/50Hz
~
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
NOMENCLATUREAND FUCTIONSNOMENCLATUREAND FUCTIONS
7
13.24V DC BATT SUPPLY
14.MIC(1~4)
MICRO(1~4)microphone input
15.GAIN
MICRO(1~4) microphone gain control
16.LINE
Audio source interface
17.REC
To recorder interface
18.POWER IN
Form effect return interface
19.PRE OUT
To effect input interface
20.OUT
Audio output
21.CHIME VOLUME
Chime volume control
22.PRIORITY
Priority control port
4.2 REAR PANEL
14 15 16 17 18 19
20
25
27
13
212223
2426
23.DIPSWITCH MIC POSITIONS (1-4)
When set to the "OFF" position, PHANTOM
POWER is turned off on INPUTS 1-4.When set
to the "ON" position,PHANTOM POWER ( 24V
DC) is available on INPUTS 1-4 ( mic position
only).
24.CHIME(2 Tone\4 Tone)
Chime(2 Tone\4 Tone) volume Control
25.PHANTOM POWER
MIC(1~4) phantom power select switch
26.SPEAKER TERMINALS
Connectors for 4 ohms or 50V \ 70V and 100V
speaker
27.~230V/50Hz AC power input
MIC1 MIC2 MIC3 MIC4
ON
OFF
ON
OFF
ON
OFF
ON
OFF
MIC PRIORITY
Project60/Project120

8
5. CONNECTIONS
70V LINE
50V LINE
5.1 SPEAKERCONNECTIONS
5.2 XLR CONNECTIONS
4
70V 100V
COM 4 50V70V 100V
COM 4 50V 70V 100V
COM 4 50V
100V LINE
70V 100V
COM 4 50V
50V\70V\
42
21 81
41
167
83
Project60/Project120
Project60
Project120 Project60
Project120
Project60
Project120

9
OPERATIONATTENTION
6. MACHINE OPERATION
1 Do not open and close the machine frequently. Reopen
should be after 10 seconds.
2 Power supply should match up to the machine.
The machine outfit with ground line, so please plug on
the connected-ground wire-net
4 As formidable shock or impact on machine such as
(thunder shock,halfway signal pause, excess rated signal
input or other interference), the machine will auto-check
and reopen automatically.
3
Project60/Project120

GAIN GAIN GAIN GAIN
MICRO1 MICRO 2 MICRO3 MICRO4 TAPE CD TUNER LINE REC PREOUT
POWERIN
OUT
POWEROUT
100V
70V
50V
4
COM
XLRBAL
1-GND
2-HOT+
3-COLD-
11
2233
PHANTOM MIC
PHANTOM MIC
PHANTOM MIC
PHANTOM MIC
VOLUME
CHIME
CHIME REMOTE
MIC1MIC1 MIC2MIC2 MIC3MIC3 MIC4MIC4
ONON
OFFOFF
ONON
OFFOFF
ONON
OFFOFF
ONON
OFFOFF
MICPRIORITYMICPRIORITY 2T 4T
1234
ON
CHIME
BATTSUPPLY
+ DC24V -
T2AL250V
230V/50Hz
~
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
10
7. APPLICATIONS
REAR PANEL CONNECTIONS
SPEAKERS
LINK
INPUTS
XLR BAL
1-GND
2-HOT+
3-COLD
1
2312
3
OUTPUTS
INPUTS
AC~ 200V-240V
50~60Hz
T5AL250V
POWER AMPLIFIER
AM
GND
ADDRESSTAG COM
ANTENNA
LOOPANTENNA
FM 75
AUDIO
OUT
RR
LL
T1AL250V
~230V/50Hz
CD PLAYER
~230V 50Hz
T1AL250V
AUDIO
OUT
R
L
COM
ADRESSTAG
AM/FM TUNER
MIC 1 MIC 2 MIC 3 MIC 4
DC 24V
CASSETTE EQUIPMENTS
RECORDER EQUIPMENTS
CONNECT WITH AUDIO PROCESSOR
EQUIPMENTS PLEASE USE SHORT
PLUGS WHEN YOU DO NOT CONNECT
EQUIPMENTS
Project60/Project120
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:

8. SPECIFICATIONS
MODEL
RATED POWER OUTPUT
Project60
60W
4 MICROPHONE INPUTS
SENSITIVITY
SIGNALTO NOISE RATIO
FREQUENCY RESPONSE
PHANTOM POWER
4 AUXILIARYINPUTS
TUNERANDTAPEINPUTS
SENSIVITY/IMPEDANCE
CD AND LINE INPUTS
SENSIVITY/IMPEDANCE
SIGNALTO NOISE RATIO
FREQUENCY RESPONSE 40/18.000Hz (-3dB)
90 dB
500 mV/47 KÙ
200 mV/47 KÙ
+48 V
40 /17.000 Hz(-3 dB)
>68 dB
-50 /-2dB2.5 /500 mV
CONTROL
BASS
TREBLE
CHIME
OUTPUTS
OUTPUT ELECTRO/IMPEDANCE
OUTPUT REC/IMPEDANCE
DISTORTION
OPERATINGCONDITION
AC MAINSINPUT
DIMENSIONS (DX WX H)mm
POWER CONSUMPTION
WEIGHT
450X340X88
230VAC 50Hz,24V DC(optional)
< 0.1%
200 mV/1KÙ
775 mV/47KÙ
2 toneand 4tone options
+12 dB
+12 dB
90W
10.1Kg
11
120W
120W
10.9Kg
450X380X88
Project60/Project120
XLR Balancedwith phantompower
Project120
FUSE 2A 3.15A

100
Over
100
Over
Over
100
9. DIMENSIONALDIAGRAM
UNIT :mm
6
84 84
340
325
88
94
436
450
UNIT :mm
12
Project60/Project120
PROJECT60
TAPE
CD
TUNERLINE
MIC 1 MIC 2 MIC 3 MIC 4 BASS TREBLEAUX MASTER
OUTPUT LEVEL
POWER
0
-12 +12
0
-12 +12
GAIN GAIN GAIN GAIN
MICRO1 MICRO2 MICRO3 MICRO 4 TA PE CD TUNER LINE REC PRE OUT
POWERIN
OUT
POWEROUT
100V
70V
50V
4
COM
XLRBAL
1-GND
2-HOT+
3-COLD-
11
2233
PHANTOM MIC
PHANTOM MIC
PHANTOM MIC
PHANTOM MIC
VOLUME
CHIME
CHIME REMOTE
MIC1MIC1 MIC2MIC2 MIC3MIC3 MIC4MIC4
ONON
OFFOFF
ONON
OFFOFF
ONON
OFFOFF
ONON
OFFOFF
MICPRIORITYMICPRIORITY 2T 4T
1234
ON
CHIME
BATTSUPPLY
+ DC24V -
T2AL250V
230V/50Hz
~
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
PROJECT60
TAPE
CD
TUNERLINE
MIC 1 MIC 2 MIC 3 MIC 4 BASS TREBLEAUX MASTER
OUTPUT LEVEL
POWER
0
-12 +12
0
-12 +12

PUBLIC ADDRESS SYSTEM
2009-11 Version1.0
This manual suits for next models
1
Table of contents
Other T&M Performance Amplifier manuals