WINDOW AIR CONDITIONER
ES

IMPORTANT -----------------------------------------
Safety Precautions ---------------------------------
Preparation for Operation ----------------------
Package Contents ---------------------------------
Window Types and Requirements -----------
Requirements before Installation ------------
Install Your Air Conditioner----------------------
Product Diagram ----------------------------------
Specifications ---------------------------------------
Control Panel ---------------------------------------
Remote Control ------------------------------------
Air Direction Adjustment -----------------------
Clean and Maintenance -------------------------
Troubleshooting -----------------------------------
Warranty and Service -----------------------------
Contents
01
06
07
07
09
10
12
20
20
21
23
25
26
28
30

Thanks for choosing TaoTronics Air Conditioner. Please read this User Guide thoroughly before
use and retain it for future reference.
IMPORTANT
READ AND FOLLOW ALL SAFETY INFORMATION AND INSTRUCTIONS. KEEP FOR
FUTURE REFERENCE.
CAUTION
·Contact the authorized service technician for repair or maintenance of this unit.
·Contact the installer for installation of this unit.
·This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved.
·Children shall not play with the appliance.
·Cleaning and user maintenance shall not be made by children without supervision.
·Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock.
·If the power cord is to be replaced, replacement work must be performed by authorized
personnel only.
·Installation work must be performed in accordance with the national wiring standards by
qualified and authorized personnel only.
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions
must be followed. Incorrect operation due to ignoring of instructions may cause harm or
damage. The seriousness is classified by the following indications.
Indicates a hazardous situation that, if not avoided, could result
in death or serious injury.
Indicates a hazardous situation that, if not avoided, may result in
minor or moderate injury.
Indicates important but not hazard-related information, used to
indicate risk of property damage.
Indicates a hazard that would be assigned a signal word
WARNING or CAUTION.
WARNING
CAUTION
NOTICE
Meaning of symbols used in this manual are as shown below.
NEVER DO THIS.
Follow the instruction.
WARNING---Installation
Do not use a power cord, a plug,
or a loose plug or a loose socket
which is damaged.
It may cause a fire or electric shock.
Do not modify or extend the
power cord length.
It will cause electrical shock or fire
due to heat generation.
Always plug into a
grounded outlet.
It may cause a fire or electric shock.
Do not disassemble or modify
the unit.
It may cause failure and
electric shock.
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

Be caution when unpacking
and installing.
Sharp edges may cause injury.
Do not store flammables like
gasoline, benzene, thinner, etc.
near the air conditioner.
It may cause explosion or fire.
WARNING---Operation
Do not place heavy object on the
power cord and ensure that the
power cord is not compressed.
There is danger of fire or electric shock.
Do not share the outlet with
other appliances.
It will cause electrical shock or fire
due to heat generation.
Take the power plug out if necessary,
holding the head of the plug and do
not touch it with wet hands.
It may cause a fire or electric shock.
Do not place the power cord
near a heater.
It may cause a fire or electric shock.
Do not allow water to run into
electric parts.
It will cause failure of machine or
electric shock.
Unplug the unit if strange
sounds, odors, or smoke come
from it.
It may cause a fire or electric shock.
If water enters the product, turn
off the power switch of the main
body of appliance.
Contact service center after taking
the power plug from the socket.
Do not open the suction inlet grill
of the product during operation.
It may cause electric shock
and failure.
No correlation between fan
usage and oxygen depletion.
An oxygen shortage may occur.
Turn off the power and breaker
first when cleaning the unit.
Since the fan rotates at high speed
during operation, it may cause injury.
Unplug the unit when not using
for a long time.
Prevent accidental startup and the
possibility of injury.
Do not operate or stop the unit by
inserting or pulling out the power plug.
It will cause electrical shock or fire
due to heat generation.
Do not damage or use an
unspecified power cord.
It will cause a fire or electric shock.
Do not operate with wet hands
or in damp environment.
It will cause electric shock.
Hold the plug by the head (not
the cable) when taking it out.
It may cause electric shock
and damage.
When gas leaks, open the
window for ventilation before
operating the unit.
It may cause explosion and a fire.
Never touch the metal parts of
the unit when removing the filter.
They are sharp and may
cause injury.
CAUTION---Installation
Install the product so the exhaust
and noise are not aimed directly
at the neighbors.
Be considerate.
Follow installation
instructions exactly.
Otherwise, it may cause vibration
or water leakage.
Use a soft cloth to clean. Do not use
wax, thinner, or a strong detergent.
The appearance of the air conditioner
may deteriorate, change color, or
develop surface flaws.
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

CAUTION---Operation
Do not use this appliance for special
purposes such as cooling pets,foods,
precision machinery, or objects ofart.
It is an air conditioner, not a
precision refrigeration system.
Do not block the inlet or outlet
of air flow.
It may cause product failure.
Use a soft cloth to clean. Do not use
wax, thinner, or a strong detergent.
The appearance of the air conditioner
may deteriorate, change color, or
develop surface flaws.
Do not step on the indoor/outdoor
unit and do not put anything on it.
It may cause an injury through
dropping of the unit or falling down.
Do not drink water drained from
air conditioner.
It contains containments and will
make you sick.
Always insert the filter securely.
Clean it every two weeks.
Operation without filters will
cause failure.
Be cautious not to touch the
sharp edges when installing.
It may cause injury.
If you eat the liquid from the
battery, brush your teeth and see
doctor. Do not use the remote
control if the battery has leaked.
The chemicals in battery could
cause burns or other health hazards.
Instead of running air conditioner
constantly, open a window for
fresh air occasionally.
You will feel better.
Do not insert the hands or bars
through the air inlet or outlet
during operation.
Otherwise, it may cause personal injury.
If the liquid from the battery gets
onto your skin or clothes, wash it
well with clean water. Do not use
the remote control if the battery
has leaked.
The chemicals in battery could
cause burns or other health hazards.
Safety Precautions
CAUTION
The power supply cord with this air conditioner contains a current detection device designed
to reduce the risk of fire. Please refer to the “Operation of Current Device” section for details.
If the power supply cord is damaged, it cannot be repaired. Please contact our Customer
Service for replacement of the cord.
Power supply cord with 3-prong grounding
plug and current detection device.
Do not, under any circumstances, cut,
remove, or bypass the grounding prong.
Operation of Current Device
The power supply cord of window type unit has creepage protection device that senses
damage to the power cord. There are TEST button and RESET button on the plug. You are
suggested to check the power cord periodically. To test your power supply cord, please follow
the steps below:
1. Plug in the Air Conditioner, the indicator turns ON.
2. Press the TEST button, the indicator turns OFF and you will notice a click as the RESET
button pops out.
3. Press the RESET button, again you will notice a click as the button engages. The indicator
turns ON again indicating the protection device is normal.
4. The power supply cord is now supplying electricity to the unit.
Notice:
·Do not use this device to turn the unit on or off.
·Always make sure the RESET button is pushed in for correct operation.
·The power supply must be replaced if it fails rest when either the TEST button is
pushed, or it cannot be reset. Please contact Customer Service for support.
·If power supply cord is damaged, it cannot be replaced. It must be replaced with
a new cord. Please contact Customer Service for support.
Indicator
grounding prong
RESET
TEST
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

WARNING
USE OF EXTENSION CORDS
RISK OF FIRE could cause serious injury or death.
DO NOT use an extension cord with this window air conditioner.
DO NOT use surge protectors or multi-outlet adapters with this window air conditioner.
Preparation for Operation
·Contact an installation specialist for installation.
·Plug in the power plug properly.
·Use a dedicated circuit.
·Do not use an extension cord or an adapter plug.
·Do not start/stop operation by plugging/unplugging the power cord.
·If the power cord/plug is damaged, replace it with an authorized replacement part only.
1 x Top Mounting Rail 1 x Top Mounting Rail Seal Strip
2 x Window Sill and Sash Seal 1 x Foam Top Window Gasket
2 x Accordion Panel Seal 2 x Foam Insulation
Package Contents
1 x Air Conditioner 1 x Left Accordion Panel
1 x Right Accordion Panel
4 x Type A Screws 6 x Type B Screws
User Guide
1 x Remote Control
(Battery not included)
1 x Window Locking Bracket 2 x Frame Locking Bracket
1 x User Manual
ES
T-ON T-OFF
AUTO
COOL
SAVE
FAN
DRY
I FEEL
SLEEP
LOCK
SPEED
°F
°C
.5H
OPER
AUTO
ON/OFF MODE
FAN I FEEL
SLEEP TIMER
Preparation Tools
Phillips-head
screwdriver
Scissors
or knife
Pencil Level Ruler or
tape measure
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

Window Types and Requirements
Note:
·The description for below installation is for the standard window. If it’s other types of
window, you may need to adjust the window.
·If you need to install the air conditioner at the small window, you may not need to use
the accordion panel sub-assy. Please refer to requirement of window size for details.
·All parts used for supporting air conditioner should be fixed at solid wooden strap,
brick or metal.
·Socket must be installed at the position where the power cord is available.
Standard window
25“-36"
13.5" Min.
Weather-proof Type Window
The height of window frame is higher than windowsill for some weather-proof type window,
which will affect the installation of air conditioner. In this case, before installing the air
conditioner, add wooden strap on the windowsill, and fix the wooden strap at the windowsill.
Specification of Wooden Strap
Width: about 2”
Length: same to the inner frame size of window
Height: Put the wooden strap on the windowsill, top part of wooden strap and window frame
should be at the same horizontal level, or higher than the top part of window frame for
about 1/4"-1/2"
1/4"-1/2"
Wooden Strap
Windowsill
Inner Wall Side
Weather-proof
Window Frame or
Plastic Window Frame
Requirements before Installation
WARNING
·Observe all governing codes and ordinances.
·Do not use damaged or non-standard power cord.
·Be caution during installation and maintenance. Prohibit incorrect operation to prevent
electric shock, casualty and other accidents.
Selection of Installation Location
Basic requirement
Installing the unit in the following places may cause malfunction. If it is unavoidable, please
consult the local dealer:
1. The place with strong heat sources, vapors, flammable or explosive gas, or volatile objects
spread in the air.
2. The place with high-frequency devices (such as welding machine, medical equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. It’s not allowed to be installed on the unstable or motive base structure (such as truck) or in the
corrosive environment (such as chemical factory).
Requirement of complete unit
1. There should be no obstruction near air inlet and air outlet.
2. Select a location where the condensation water can be dispersed easily and won't affect
other people.
3. The location should be able to withstand the weight of the unit and won't increase noise
and vibration.
4. Select a location where the noise and outflow air emitted by the outdoor unit will not
affect neighborhood.
5. The location should be able to withstand the weight of unit.
6. Select a location which is out of reach for children and far away from animals or plants. If it is
unavoidable, please add fence for safety purpose.
7. Please try your best to keep far away from fluorescent lamp.
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

Selection of Installation Location
Basic requirement
Installing the unit in the following places may cause malfunction. If it is unavoidable, please
consult the local dealer:
1. The place with strong heat sources, vapors, flammable or explosive gas, or volatile objects
spread in the air.
2. The place with high-frequency devices (such as welding machine, medical equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. It’s not allowed to be installed on the unstable or motive base structure (such as truck) or in the
corrosive environment (such as chemical factory).
Requirement of complete unit
1. There should be no obstruction near air inlet and air outlet.
2. Select a location where the condensation water can be dispersed easily and won't affect
other people.
3. The location should be able to withstand the weight of the unit and won't increase noise
and vibration.
4. Select a location where the noise and outflow air emitted by the outdoor unit will not
affect neighborhood.
5. The location should be able to withstand the weight of unit.
6. Select a location which is out of reach for children and far away from animals or plants. If it is
unavoidable, please add fence for safety purpose.
7. Please try your best to keep far away from fluorescent lamp.
Requirements for Electric Connection
Safety Precaution
1. Must follow the electric safety regulations when installing the unit.
2. According to the local safety regulations, use qualified power supply circuit and air switch.
3. Please make sure the power supply complies with the requirement of air conditioner. Unstable
power supply or incorrect wiring may lead to electric shock, fire hazard or malfunction.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to electricity and safety.
6. Do not put through the power before finishing installation.
7. The air conditioner is first class electric appliance. It must be properly grounding with
specialized grounding device by a professional. Please make sure it is always grounded
effectively, otherwise it may cause electric shock.
8. The yellow-green wire or green wire in air conditioner is grounding wire, which can't be used
for other purposes.
9. The grounding resistance should comply with national electric safety regulations.
Install Your Air Conditioner
Step 1: Install Top Mounting Rail
1. Tear off the paster at back side of top mounting rail seal strip, and then align it at the bottom
edge of top mounting rail to stick the top mounting rail seal strip at the bottom of top
mounting rail.
2. Use 4 type A screws to fix the top mounting rail at the outer case of air conditioner.
ES
top mounting rail
top mounting rail
seal strip
type A screw
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

RIGHT
ES
RIGHT
ES
Step 2: Install Accordion Panel
1. Stick one accordion panel seal respectively on the left side and right side of accordion panel
installation frame.
2. Undraw the accordion panel, install the accordion panel marked with “LEFT” and “RIGHT” at
both sides of the air conditioner respectively.
Step 3: Stick Window Sill and Sash Seal
Cut the Window sill and sash seal into proper length. Tear off the paster and then stick the seal
at the lower part of the window frame.
Step 4: Place Air Conditioner
1. Ask 2 persons to put the air conditioner at the windowsill, and the lower guide rail should be
stick at the windowsill. Top mounting rail stays at the middle lower side of window and then
window can stick to the top mounting rail when closing it. Please note that the air conditioner
should be placed at horizontal place or inclined outwards slightly.
Front
accordion panel
top mounting rail
Lower Guide Rail
Window sill and sash seal
LEFTLEFTLEFT
LEFT
ES
LOW
Timer Mode Fan On/Off
MED HIGH AUTO
RIGHT
LEFT
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

Window Frame
Lower Guide Rail
Top Mounting Rail
about 3°
horizontal or inclined
about 3°
Inner Wall Side
Side
2. Pull the window, undraw accordion panels at both sides to keep it vertical to the window
frame and then use 5 type B screws to fix the frame of accordion panel at window frame
and windowsill.
Window Frame
type B screw
type B screw
Step 5: Install Window Locking Bracket
Install the window locking bracket at the window frame to fix the window.
Plastic
window
Wooden
window
Step 6: Plug Foam Top Window Gasket
Cut the foam top window gasket into the length same to the width of window. Plug the foam
between glasses and window to prevent rain and insects getting into the room.
foam top window gasket
Note:
If Foam top window gasket is
not proper to your window,
you can select other proper
materials to replace it.
type B screw
ES
LEFT
RIGHT
ES
LEFT
RIGHT
ES
LEFT
RIGHT
Frame Locking Bracket
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

1.Install accordion panel sub-assy. After finishing installation, measure the width L between outer
case of air conditioner and window frame.
L
2. Take out foam insulation from the package. Cut off the foam insulation in rectangular shape
with scissors.
L
Step 8: Sponge Sticking Method and Procedures
Step 7: Drain water
This model features a drain hole to expel condensed water, when the water reaches a given level
it drains away automatically. Connect a proper-sized drain hose (not included) to the drip hole to
divert the water wherever you wish if the drip sound annoys you.
Inner Wall Side
Side
Unscrew the hole
cap off the body
Inner Wall Side
Drain hole
ES
LEFT
RIGHT
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

3. Stick foam insulation evenly on the accordion panel and the screen of window frame. The
redundant 2~3mm of foam insulation in height can be stuffed into the frame for fixing. Product Diagram
Control Panel
Air Outlet Frame
Air In Panel
Power Cord
Specifications
Model
Refrigerant
Cooling Capacity
Cooling Power Input
Cooling Power Current
Rated Voltage
Rated Frequency
Rated Input
Rated Current
CEER
Operating Temperature Range
(Maximum Cooling)
Dimensions
Net Weight
TT-AC003
R32
2345 W
660 W
6.0 A
115 V
60 Hz
780 W
6.9 A
12.1(Btu/h)/W
Indoor side DB/WB (°C/°F): 32/23 (89.6/73.4)
Outdoor side DB/WB (°C/°F): 43/26 (109.4/78.8)
54.2×34.9×47.7cm / 21.4"×13.7"×18.9"
28 kg / 61.7 lbs
RESET
TEST
ES
LEFT
RIGHT
ES
LEFT
RIGHT
ES
Drain hole
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

Control Panel
①⑤②
④
⑥
①On/Off Button
② Dual-8 display
③ Temperature/Timer Increase Button
④Temperature/Timer Decrease Button
⑤ Fan Button
⑥ Mode Button
⑦ Timer Button
Button Control
Function
· Turn the unit ON or OFF.
· Turning on the unit via Control Panel, the unit will operate in Energy
Saver mode automatically.
· Timer Setting: Display time.
· Auto, Cool, Energy Saver and Dry Mode: Display set temperature.
· Fan Mode: Display room temperature.
· Timer Setting: Increase the delay time.
· Cool, Energy Save and Dry Mode: Increase the set temperature.
· Timer Setting: Decrease the delay time.
· Cool, Energy Save and Dry Mode: Decrease the set temperature.
· Confirmation time:
Temperature setting: 3s after setting finished
Timer setting: 5s after setting finished
Adjust the fan speed: Low, Med, High, Auto.
Cycle through modes: Cool, Energy Save, Fan, Dry, Auto.
Button
① Power Button
② Dual-8 display
③ Temperature/Timer
Increase Button
④ Temperature/Timer
Decrease Button
⑤ Fan Button
⑥ Mode Button
· When the unit is OFF, it can be set to automatically turn ON the air
conditioner under Energy Save mode from 0.5 (30 minutes) to 24 hours.
· When the unit is ON, it can be set to automatically turn OFF the air
conditioner from 0.5 (30 minutes) to 24 hours.
· Press ▲/ ▼buttons to adjust the Auto-ON/OFF time, timer setting
will be confirmed after finishing setting for 5s.
After the unit operates for 250 hours accumlatively, Filter cleaning
indicator will light up to notify that the filter needs to be cleaned.
After the filter is cleaned and reinstalled, press and hold “Timer”
button and “—” button simultaneously to clear the operation time. The
Filter cleaning indicator will turn off.
⑦Timer Button
Filter Cleaning
Note:
The temperature is displayed in degree Fahrenheit (°F) by default. To change to degree
Celsius (°C), press and hold the “+” and “-” buttons simultaneously for 3 seconds. Repeat
the process to change it back to degree Fahrenheit (°F).
ES
LOW
Timer Mode Fan On/Off
MED HIGH AUTO
⑦
ES
LOW MED HIGH AUTO
Display
Button
Cool mode Fahrenheit unit
Dry mode
Fan Only mode
Auto mode
Filter cleaning
Indicator
Energy Save
mode
Sleep mode
Low speed
indicator
Medium
speed
indicator
High speed
indicator
Auto speed
indicator
③
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

Remote Control
T-ON T-OFF
AUTO
COOL
SAVE
FAN
DRY
I FEEL
SLEEP
LOCK
SPEED
°F
°C
.5H
OPER
AUTO
ON/OFF MODE
FAN I FEEL
SLEEP TIMER
① ON/OFF Button
②MODE Button
③+ / - Button
④FAN Button
①②
③ ③
④ ⑤
⑥⑦
Button Control
Function
· Turn the unit ON or OFF.
· Turning on the unit via Remote Control, the unit will operate in Energy
Saver mode automatically.
· Cycle through modes: AUTO, COOL, SAVE, FAN and DRY.
Temperature Adjustment:
· Press the button once to increase or decrease the set temperature by 1°F (°C).
· Press and hold the button for 2s to quickly adjust the set temperature.
Time Adjustment:
· Press the button once to increase or decrease the time by 0.5h.
· Press and hold the button for 2s to quickly adjust the time.
Adjust the fan speed:
· Press to activate I FEEL function.
· If controller receives I FEEL order, it will work under ambient temperature
value sent by remote control every 10 minutes.
· After 11 minutes, if controller does not receive ambient temperature value
sent by remote control, it will run with AC ambient temperature.
· If I FEEL is not set, the ambient temperature will adopt sampling value of
AC temperature sensor.
· If power off happens, this function will not be memorized.
· Press to enter SLEEP mode. Press it again to cancel.
· This function is available in COOL, SAVE or DRY mode to maintain the
most comfortable temperature for you.
· Press the button once to activate Auto-ON/ Auto-OFF timer.
· Press the button twice to cancel Auto-timer.
· Press “+” and “-” buttons simultaneously to turn on/ off Child Lock function.
· When the function is activated, LOCK indicator on remote control will turn ON.
When the unit is OFF, press the “-” button and “MODE” button
simultaneously to switch between °C and °F.
Press and hold the "+" and "FAN" buttons simultaneously for 3 seconds to
turn the light on or off.
Button
① ON/OFF Button
② MODE Button
③ + / - Button
④ Fan Button
⑤ I FEEL Button
⑥ SLEEP Button
⑦ Timer Button
Child Lock
Temperature
Display Switchover
Light Function
AUTO
⑤I FEEL Button
⑥SLEEP Button
⑦TIMER Button
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

Replacement of Batteries in Remote Control
1. Remove the battery box cover.
2. Replace with two new #7 (AAA 1.5V) dry batteries. Make sure positions for “+” pole and “-” pole
are correct.
3. Reinstall the battery box cover.
NOTICE
·The distance between signal sender and receiving window should be no more than 8
meters, and there should be no obstacles between them.
·As the signal will be interfered in the room with electronic fluorescent lamp, conversion
fluorescent lamp or wireless phone, please get closer to the air conditioner when using
the remote control.
·Replace with new batteries of the same model when replacement is required.
·When not using the remote control for a long time, please take out the batteries.
Air Direction Adjustment
Adjusting Horizontal Air Flow Direction
You can adjust the horizontal direction by moving the fan direction adjusting frame to the left or right.
Adjusting Vertical Air Flow Direction
You can switch the vertical direction by pressing any corner of the air outlet frame up or down.
Clean and Maintenance
WARNING
· Turn off the air conditioner and disconnect the power before cleaning the air conditioner to
avoid electric shock.
· DO NOT wash the air conditioner with water to avoid electric shock.
· DO NOT use volatile liquid to clean the air conditioner.
Cleaning the Filter
ES
ES
ES
1. Pull the groove at both sides of panel
forcibly to open the panel to a certain angle.
ES
ES
2. Remove the filter.
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

NOTICE:
· Clean the filter about once every three months. If there are lots of dust in operation
environment, you can increase the clean times.
· There are shaft metal fins in the air conditioner, do not touch the fins after removing the
filter to avoid scratching.
· DO NOT dry the filter on fire or use hair drier to dry the filter. Otherwise, the filter may be
deformed or catch fire.
· DO NOT operate the air conditioner when the filter hasn’t been installed.
Cleaning the Panel
If the surface of panel is very dirty, you are suggested to use soft dry cloth or wet cloth dipped with
neutral abluent to wipe it.
Note: Do not remove the panel when cleaning it.
Note: In order to reduce damage or rust under no-use season, you can cover the air
conditioner with protective covering.
Maintaining the Outer Case
You are suggested to check the outer case of air conditioner one or twice every year. If the outer
case is damaged or rusted, please contact the dealer.
Troubleshooting
Please check below items before asking for maintenance. If the problem still cannot be solved,
please contact Customer Service for support.
What To Do
Wait after power recovery.
Make sure the air conditioner plug is pushed
completely into the outlet.
Try plugging the air purifier into a different outlet.
Ask professional person to replace the circuit.
Wait after voltage is resumed.
Please press RESET button on plug again. If the
power trips off again with a sound, there's
malfunction for the plug or the unit. Please
contact Customer Service for support.
Wait after voltage is resumed.
Make sure there are no curtains, blinds, or
furniture blocking the front of the air conditioner.
Clean the air filter.
Adjust the temperature.
Close the door and window.
Please pull out the plug. Insert the plug after
about 3 minute, and then turn on the unit.
The receiving range of remote control is 8
meters. Do not exceed this range.
Remove the obstacles.
Check the batteries of remote control. If the
power is low, please replace the batteries.
Possible Causes
Power failure.
The air conditioner
is unplugged.
The air switch is
tripped off or fuse
is burnt.
Circuit malfunction.
The unit is restarted
up after stopping
immediately.
The protection
device for the plug
of power cord trips off.
The power is too low.
The airflow is restricted.
The air filter is too dirty.
The temperature is
not set properly.
The door and
window are not closed.
The unit is interfered
seriously (such as
static pressure,
unstable voltage).
The remote control
is out the receiving
range.
The remote control
is blocked by obstacles.
The sensitivity of remote
controller is low.
Problem
Air
conditioner
cannot start
Air
conditioner
does not cool
as it should
Air
conditioner
can't receive
signal from
remote control
or the remote
control is not
sensible
3. Clean the Filter
· Use dust catcher or water to clean the filter.
· If the filter is very dirty, you can use the
warm water (below 113°F) dissolved with
neutral abluent, and then put it under the
shady place.
ES
4. Install the filter and then buckle the
panel cover.
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

What To Do
Move the remote control close to
air conditioner.
Turn off the fluorescence lamp and
try it again.
This is normal. If too loud, set to
lower FAN speed.
Refer to installation instructions or
check with installer.
Clean the air filter.
Set FAN speed to a faster setting to bring
air through cooling coils more frequently
Eliminate the obstacles.
Temperature cannot be adjusted under
AUTO mode.
Temperature setting range: 61°F ~86°F
Increase the set temperature.
For proper water disposal, make
sure the air conditioner slants slightly
from the case front to the rear.
Eliminate the off-flavor source.
Clean the filter.
Disconnect the power, and then
turn on the unit again.
It is normal that there is flowing sound of
refrigerant inside the air conditioner.
Heat expansion or shrinkage for the
panel due to temperature change,
which causes friction sound.
Possible Causes
There's fluorescence lamp
in the room.
Air movement sound.
Window vibration – poor
installation.
Dirty air filter - air restricted.
Outside temperature
extremely hot.
The air outlet or air inlet
is blocked.
The unit operates under
AUTO mode?
The required temperature
exceeds the temperature
setting range?
Set temperature too low.
The air conditioner is not
tilted to the outside.
There's off-flavor source in
the room, such as furniture,
cigarette, etc.
The unit is interfered by
thunder, radio, etc.
The unit is turned on or
turned off just now.
The unit is turned on or
turned off just now.
Problem
Air conditioner can't
receive signal from
remote control or the
remote control is not
sensible
Noise when
unit is cooling
Air conditioner
turns on and off
rapidly
No air blewout
from air conditioner
Set temperature
cannot be
adjusted
Room too cold
Water drips
indoors
There's off flavor
There's abnormal
sound during operation
You can hear
water-flowing sound
You can hear
"PAPA" sound
WARNING
· If below abnormalities occur, please turn off the air conditioner and disconnect the power
immediately. After that, please contact Customer Service for support.
→Power cord is overheating or damaged.
→ There's abnormal sound during operation.
→ There's burning smell.
→ Power cord test or reset button often bounces automatically.
→ Water leakage at indoor side.
· Do not repair or refit the air conditioner by yourself.
· Operate the air conditioner under abnormal status will cause malfunction, electric shock or
fire hazard.
Warranty and Service
This product is covered with TaoTronics product and labor warranty for 12 months from the
date of its original purchase. If any problems occur, please contact the TaoTronics Customer
Care Centre via the contact information listed in this User Guide.
We can only provide after sales service for products that are sold by TaoTronics or TaoTronics
authorized retailers and distributors. If you have purchased your unit from a different place,
please contact your seller for return and warranty issues.
29 30
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28

E-mail:
MANUFACTURER
Manufacturer: Shenzhen NearbyExpress Technology Development Co.,Ltd.
Address: Floor 7, Building E, Galaxy World Phase II, Shenzhen, China
Rev_1.0_EN
01 03 05 07 09 11 13 15
17 19 21 23 25 27
02 04 06 08 10 12 14 16
18 20 22 24 26 28
MADE IN CHINA
Table of contents
Other TaoTronics Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Haier
Haier HWF05XCJ Service manual

Fujitsu
Fujitsu ASYE14 installation manual

LG
LG MFL42803121 installation manual

Whirlpool
Whirlpool PORTABLE AIR CONDITIONER Use & care guide

Friedrich
Friedrich CP15F10A Installation and operating manual

Mitsubishi Electric
Mitsubishi Electric PEFY Series Technical & service manual