ThermoPro FC-500 Operating instructions

1
AIR COOLER FC-500
MANAUL FOR SAFITY AND USE
English Edition 10E
Helsinki 2015

2
TABLE CONTENTS
1. Introduction............................................................................3
1.1 Documents, taken into account in a process of production
and manual for use set up.......................................................... 3
2. Safety measures working with the Machine.......................... 4
2.1. Precautions and safely when using the equipment. ...........5
3. Description of the Device .......................................................7
3.1.Technical Specification of Air Cooler.................................... 7
3.2. Air Cooler FC-500 delivery set ........................................ 7
4. Start Up...................................................................................8
4.1. First Switch On..................................................................... 8
5. Equipment operation ............................................................. 9
5.1 Operation and Process control............................................. 9
5.2 Process of working completion ........................................... 9
6. Maintanence.......................................................................... 9
7. Terms of Warranty limitation..............................................10
8. Disposal ................................................................................13

3
1. Introduction
We are grateful for your decision to buy our Air Cooler FC-500.
It is fabricated by us especially for You in accordance with the
highest quality standards and tested by our experts on
compliance with EU directives presented in the Section
"Documents taken into account in production and
documentation" before shipping the equipment to you.
Despite the fact that the equipment is simple enough to use, we
strongly recommend that you read the instructions before
starting work, paying close attention to the Safety Instructions.
Air Cooler FC-500 was developed to secure PCB cooling speed
and can work as a separate aggregate. At the same time Air
Cooler FC-500 can be easily integrated into an Reworking
Soldering Center IR-650 Pro. To do this, simply connect the
device to the USB port of the computer and the "TERMOPRO -
Center" Program will automatically recognize it and will adjust a
desired rate of cooling in accordance with a predetermined
thermal profile. Cooler FC-500 is recommended to complete a
soldering set based on Pre-heating systems of NP Series, but
Cooler FC-500 is also often used for cooling circuit boards with
any other Pre-heaters.
1.1 Documents, taken into account in a process of
production and manual for use set up.
For EU Countries only:
OOO NTF “Techno Alliance Electronics” being the responsible
Manufacturer declares that Digital Bottom Pre-Heating and
Soldering System of NP Series with Characteristics presented in
Section 3.1 is a serial product and meets following EU Directives:
-Directive 2006/95/ECs relating to electrical equipment
designed for use within certain voltage limits.

4
- Directive 89/336/ЕС related to electro-magnetic
compatibility of 3rd May 1989;.
- Machinery Directive 2006/42/EC of the European
Parliament and of the Council of 17 May 2006 on machinery and
amending Directive 95/16/EC.
Technical documentation for EU Authority Use is kept by
European official Representative of the Manufacturer:
K&K Kauppa ja Konsultointy Oy:
Fredrikinkatu 33B,
00120 Helsinki
Finland
1.2. Briefly about Manufacturer
The Scientific-Technics Firm "Techno Alliance Electronics" was
founded in 1993 in Moscow, Russia. Since that time the quality and
service of “TERMOPRO” Brand was appreciate by hundreds of
enterprises of dozens High-Tech industries. We have thousands
customers among modern service centers who use modern
methods of repair both with BGA components and without them.
Contact coordinates of OOO
NTF "Techno Alliance Electronics" the office and plant on the page
#9 of this Manual.
2. Safety measures working with the Machine
WARNING: Read all instructions and safety
recommendations. Failure to follow warnings and instructions
may lead to electric shock, burns, fire and / or serious injury.

5
Keep these instructions with recommendations for future
use.
Air Cooler FC-500 was designed only for cooling of
electronic modules (PCB’s) in a process of installation and
removal of electronic components. Another use of Cooler as
a separate aggregate or as an integrated part of
Reworking Center will be considered by the manufacturer
as executed by the user at his (User) personal responsibility
and risk.
2.1. Precautions and safely when using the equipment.
Never insert any foreign objects and/or fingers
between fan blades. It can cause serious injury and damage the
equipment.
In case of operation fault, do not open the device
housing case yourself (this can cause even more damage), and
contact a experiences service.
General safety work on electrical installations and heating
devices shall be carried out working with the Cooler. The room in
which the product operates must be equipped with fire
extinguishing agents and exhaust ventilation.
All inter-unit connections have to be made before
connecting the device to the power supply line. All connectors

6
must be secured with cap nuts (where applicable). Before
switching on, make sure that grounding outlet or a separate
ground terminals are in order.
A fuse replace should be carried out only when the
device is switched off (the power cord must be disconnected
from Power line socket).
NEVER!
• connect the unit to Power supply line without the ground ; in
the absence of a reliable grounding the proper functioning of
the installation can not be guaranteed;
• leave turned on unit unattended;
• turn on a Cooler near flammable materials and flammable
liquids;
•spray flamable liquids near working equipment;
• carry out maintenance without shutting down the product
the unit and disconnecting it of power supply line.
WARNING: DO NOT let comfort or experience in
device operation (gained from repeated use) dominate strict
adherence to safety rules for handling this device. Improper use of
tools or failure to follow the safety rules stated in this Manual may
cause serious personal injury.

7
3. Description of the Device
3.1.Technical Specification of Air Cooler
Nominal Voltage / Maximum current
12V / 1А
Max. Air blow rate
2,3 m3/min at 50W
Working modes
Continuous or
intermittent
Noise level (max)
40 dB
Dimensions
80х150х310 mm
Weight (with power adapter)
1,4 (1,9) kg
3.2. Air Cooler FC-500 delivery set
Pic. 1.Air Cooler FC-500
Air Cooler F-500 delivery Set includes:
- Cooler Unit on support

8
- Power adapter ~220-230V/12V 1А
- USB Interface cable for connection with PC
- Grounding wire
Before equipment start up make sure that delivery set is
complete and nothing missed or damaged. If the above items
damaged or missed, please contact your supplier.
4. Start Up
4.1. First Switch On
First of all, please read the present Manual for Safe Use. Then,
the procedure is as follows:
Unpack unit;
Place it on a flat and hard surface of the desktop;
Place the unit in a way to ensure maximum ease of movement
for operator and avoid appearance of foreign subjects against
fan blades;
Fix a ground wire with a control nut on a unit housing case
panel. Other end of the ground wire connects to ground
terminal.
For a work of FC-500 under PC control drivers are to be
installed to computer prior the work (driver can be downloaded
from our web-site or installed from media supplied with
Reworking Center), after that connect unit to PC using supplied
USD interface cable.
Connect Power adapter to a terminal at unit FC-500 housing
first and then to a power line 220V. Red indicator near “power
on” bottom will start blinking.
If it is necessary you can adjust Cooling unit height position. For
this matter unscrew screws on housing and install these into
other fixing holes on supporter. Air flow angle can be also
adjusted against PCB in a work.

9
The unit is ready for an operation.
5. Equipment operation
5.1 Operation and Process control
Press the Power on/off button. The red light will be lit on
constantly, and built-in fans will gain the necessary rotation
speed.
Direct the air flow from device louvers on the circuit board.
Adjust the desired air flow speed of the cooling by pressing [+], [-
]. The speed may have 16 fixed pre-sets of airflow rates which
are changed discretely.
The flow rate can be evaluated on a scale of four LEDs positioned
next to the control buttons.
Never insert foreign objects or fingers against the fan blades, this
can lead to injury or damage to the product.
Working with FC-500 under PC control please study “Termopro-
Center” Program Manual in Sections referring FC-500 unit
control.
5.2 Process of working completion
- Shut down the “Termopro-Center” program.
- Turn the power off
- Disconnect power adapter from Power supply line.
6. Maintanence
Make sure that ground cable has no defect and damages,
and its terminals are properly fixed.

10
Remove a dust from the unit surface.
Make sure that all four built-in fans are rotating.
Replace a fan in case of increased noise level.
7. Terms of Warranty limitation
The Manufacturer reserves the right to introduce any
changes into design, working scheme, internal program of the
Controller and into software, supplied with equipment, any time
and without preliminary notification. The present Manual also can
be changed any time without preliminary notification.
The manufacturer is committed to the toll-free repair or
replacement of hardware components within 12 months, subject to
the user's manual of recommendations set forth herein. Possibility
of warranty repair service is determined by an authorized local
service company or by the manufacturer after the examination
(inspection) equipment.
For repairs, contact the organization at the place of
purchase of the system. After the warranty period repair is possible
for an extra charge. The cost of repair is determined by an
authorized local service company or the manufacturer after the
examination of faults.
The Manufacturer does not provide Warranty services
either obvious or undermine if these are not presented and listed
into the Clause. Any undermine warranties are limited by the
present warranty by Law.
Within Warranty period:
The manufacturer provides free repair or replacement of
the defective product (products) of its with similar product without
defects during the limited warranty period. If the product is no
longer available, the defective product will be replaced with the

11
same product or a similar type, if a defect in material or
workmanship is found within the limited warranty period.
The warranty period starts from the date of first customer
purchase. Evidence of the date of purchase is a waybill or transport
company consignment note with date delivery to the first customer.
Also, the reference period of the guarantee may start from the date
specified in the warranty card manufacturer provided if the product
serial number, signature and seal of the trading organization are
presented on the card.
If the buyer can not submit the above mentioned
documents, the warranty period begins on the date of product
acceptance by Manufacturer product control department. Date of
acceptance is determined by the serial number of the product. This
limited warranty does not extend to any product from which the
serial number has been removed (or replaced). Warranty repairs
carried out on the territory of the manufacturer, and any transport
costs borne by the Buyer. The warranty period is extended for a
period of the product repair. Extending the guarantee does not
apply at the time of return shipment of the product to a place of
repair.
The Buyer has to cover the costs of materials and repair job,
if a warranty service work is carried out when warranty period is
over.
Manufacturer warranty within the warranty period in applied
at:
Materials used for manufacturing;
Quality and precision of mechanical parts work;
Assembly correctness and calibration of equipment.
Stability in time of declared technical characteristics and
functions.
Manufacturer Warranty does not cover following:
Natural wear and loss of materials and parts.

12
gradual loss of electrical contacts due to high temperatures
exposure in combination with corrosive vapors of materials
used, and other external factors.
Destruction of the paint, electroplating, corrosion due to
high temperatures exposure and corrosive vapors used in
the materials as well as other external factors.
Violations of the present manual recommendations by user
during equipment operation.
Mechanical or other damage to the product due to
negligence of User.
Unauthorized changes of design or electrical schematic by
User.
Attempts of unauthorized repair.
Improper and untimely maintenance.
Damage to products due to improper transportation.
Any damage caused by natural disasters, earthquakes,
lightning, abnormal voltage or environmental influences.
All costs the manufacturer carries for non-warranty repair and/or
replacement are on a buyer’s side.
The manufacturer does not hold warranty for the following
materials and products:
Perishable parts
Lubricants
Packing materials and manual itself
Cables, connectors from other manufacturers supplied in a
set with equipment (these are covered by its manufacturer
warranty).

13
8. Disposal
Disposal of old and replaced equipment parts, spare parts and/or
the center as a whole should be carried out by the Buyer or the End
User in accordance with the laws of Your Country.

14
Deisgn and production of all “ThermoPro” devices,
“ThermoPro-Center” Software and all rights to this brand owner is
OOO NTF “Techno-Alliance Electronics”
Russian Federation 113570, Moscow, Ulitsa Krasnogo
Mayaka, 13, k4
Tel: +7 (495) 231-37-21
http://www.termopro.ru, E-Mail: ta@termopro.ru
Edition 10E от 10.12.2015
The program Developers and Writerts:
V. Kuzichkin, A.Rukavishnikov
Editor: E. Shulika
English Translation: M.Kondrashov
All notes, advices, recommendation as well as information
about mistakes can be sent to company mail: termopro2010@mail.ru
Table of contents
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual