Trico Spectrum Essential User manual

Trico Corporation
Spectrum Essential
Oil Storage System
Revision: 10/1/21 – 61267 A


Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 1 | 20
TABLE OF CONTENTS
TABLE OF CONTENTS..........................................................................................................................1
INTRODUCTION .................................................................................................................................2
IMPORTANT SAFEGUARDS .................................................................................................................2
WARNINGS ........................................................................................................................................3
Electrical Precaution.......................................................................................................................3
Flammable Liquids .........................................................................................................................3
Static Discharge..............................................................................................................................3
Running Dry Gear Pumps................................................................................................................3
Possible Pinch Point .......................................................................................................................4
Possible Tipping Point / Caution While Moving ...............................................................................4
OVERVIEW.........................................................................................................................................5
STEP-UP & INSTALLATION ..................................................................................................................6
Time, Materials, Personnel, and Tool Requirements........................................................................6
System Placement Determination...................................................................................................6
Attaching Watchdog Extreme Humidity Desiccant Breathers (Part #39141)......................................7
Spectrum Color Coding ...................................................................................................................7
Mounting the On/Off Motor Switch................................................................................................8
Powering the Motor/Pump.............................................................................................................8
Adding Additional Storage Stacks (Part #37202) to Expand the System ............................................9
OPERATION INSTRUCTIONS..............................................................................................................12
Filling Storage Tank ......................................................................................................................12
Dispensing Lubricant ....................................................................................................................14
MAINTENANCE CHECKLIST ...............................................................................................................15
MOVING THE SYSTEM ......................................................................................................................15
TROUBLESHOOTING.........................................................................................................................16
REPLACEMENT PARTS ......................................................................................................................17
TEMPERATURE VS. VISCOSITY ..........................................................................................................18
LIMITED WARRANTY ........................................................................................................................19

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 2 | 20
INTRODUCTION
Trico Spectrum Oil Storage Systems are an innovative solution to resolving bulk oil storage issues for
constricted space requirements. They allow expansion from the base unit while eliminating
contamination issues. Storage systems are available with up to a 6-tank configuration depending on
your bulk storage requirements. All systems come standard with 1-1/4” Heavy Wall Wire-Yarn
Reinforced clear Phthalate Free PVC lines and brass shutoff valves. Gravity dispensing valves are
standard self-closing bronze with a 3/4" NPT nozzle threading. The tanks are filled using a manifold
system with independent T-Handle valves for each tank, as well as a drain flush valve to minimize cross-
contamination. Each 2-tank stack comes with a 73 Gallon Spill Containment Reservoir with a built-in
dispensing tray area. The motor and pump combination draw a maximum of 17.2 amps requiring the
system to be placed on a separate 20-amp circuit. The bronze gear pump is positive displacement and
self-priming.
Fluid Capacity per Tank
65 Gallons
Containment Capacity
73 Gallons (>110% per Spill Container)
Tank Sight Gauges
3 @ 1” NPT Steel Viewports
Tank Lines
1-1/4” Heavy Wall Wire-Yarn Reinforced clear Phthalate Free PVC
Tank Shut Off Valves
Brass Ball Valves
Dispensing Valves
Self-Closing 1” Bronze with 3/4" NPT Threading
Max Temperature
150°F/65°C
Max Viscosity
12,000 SUS (2600 cSt)
ISO 680 at 70°F
Pump Head
Bronze Gear
Pump Relief
105 PSI
Max Flow Rate @ ISO 32, 70°F
4.5 GPM
Electric Motor
1-1/2 HP TEFC
Electrical Motor Rating
115V, 60Hz, 17.2A, NEMA 5-20P
Rack Weight Capacity Rating
2500 LBS
Wetted Parts Material Composition
Steel – Stainless, Galvanized & Zinc Platted; Viton; Buna; Brass;
Bronze; Iron – Galvanized & Black-Coated; PVC; Aluminum
Warning: Do not store flammable products with a flashpoint below 200°F, products with
a pH below 3, or products with a pH above 13. Storing unapproved products can result in
serious bodily injury or death and will void any product warranty.
IMPORTANT SAFEGUARDS
1. Read and Retain Instructions - All safety and operating instructions should be read before using
the Spectrum Oil Storage System. They also should be retained for future reference.
2. Heed Warnings - All warnings on the product and in the operating manual should be adhered to.
3. Follow Instructions - All operating instructions should be followed.
4. ALWAYS wear appropriate Personal Protective Equipment while operating this system.
5. ALWAYS check that all system hoses and fittings are securely fastened and in good working
condition before operating this system.

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 3 | 20
WARNINGS
Electrical Precaution
Always use safety around electrical equipment, follow instructions to prevent electrical shock. Electrical
shock may cause death or other serious bodily harm. Although the Trico Spectrum Oil Storage Systems
are designed with Totally Enclosed, Fan-Cooled (TEFC) motors they cannot be submersed into liquids.
Use precaution when operating in wet environments and do not allow excess lubricant to encounter
electrical components. If fluid does encounter electrical components, immediately disconnect the power
by removing the electrical plug at the outlet or turn the power off at the breaker.
Amperage draw from the electric motor varies due to load at normal operating conditions. Full load
amperage for the Spectrum Essential Oil Storage System is 17.2A and a separate 20 Amp circuit is
recommended. Failure to use the appropriate circuit type may cause overloading of the circuit and trip
the breaker. Repeated attempts to use equipment on the same tripped circuit will cause an electrical
fire. Ensure to consult a certified electrician to identify proper outlets before using equipment.
Flammable Liquids
Do not use with flammable liquids. Do not use in areas where there is presence of large amounts of
flammable fumes. Failure to comply may cause an explosion. Always take precautions when working
around open fuel sources.
Static Discharge
Due to the rate of flow of oils across different materials there is always a potential to build up a static
charge. Static discharge can cause an explosion if near, or around, open flammable fluids. Bonding and
ground safety procedures must be used when operating in hazardous duty environments or when there
is a danger of static discharge. See National Fire Protection Code 77 for proper grounding and bonding
procedures. It is the responsibility of the operator to properly inspect and ground equipment before
use, no grounding cabling is included with this system.
The Trico Spectrum Oil Storage Systems are not rated for a hazardous duty environment due to possible
static discharge, use proper bonding and grounding per National Fire Protection Code 77. A Bonding
system connects various pieces of conductive equipment together to keep them at the same potential.
Static sparking cannot take place between objects that are the same potential. Grounding is a special
form of bonding in which conductive equipment is connected to an earthing electrode, or to the building
grounding system, to prevent sparking between conductive equipment and grounded structures.
Grounding is an electrical connection between a metal vessel, pump, motor, and a constant ground.
Failure to bond and ground properly can cause a discharge of static electricity resulting in fire, injury, or
death. If in doubt, do not start the pump! Be sure bonding and grounding wires are secure before
starting operation. (Ground and bond wires must have less than one-ohm resistance for safe usage.
Check continuity before starting.) Always check with a safety engineer when any question arises and
periodically check safety procedures with a safety engineer.
Running Dry Gear Pumps
The Trico Spectrum Oil Storage Systems are self-priming units. Lubrication is not provided to the pump
gears at the factory before the units are shipped. After assembly and before operating for the first time,
it is recommended to place a small amount of oil that is intended to be pumped into the suction wand
line and allow the fluid to enter the pump gears by elevating the suction wand line higher than the
pump head. This should also be done whenever the units have been stationary for over a month or has

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 4 | 20
been cleaned or serviced. Running the pump gears dry will cause premature wear and shorten the life
of your system.
Possible Pinch Point
The Trico Spectrum Oil Storage Systems use Self-Closing 1” Bronze Dispensing Valves. These valves are
spring loaded to always remain closed. Due to the nature of the self-closing valves, a pinch point may be
present on the valve when opening and closing the valves. This pinch point is greatly enhanced when the
dispensing valve lines are under pressure, causing a greater force to open, and ultimately close the
valves. Please use caution when using the valves and be aware this pinch point does exist.
Possible Tipping Point / Caution While Moving
The Trico Spectrum Oil Storage Systems have an empty weight near 1,000 pounds per 2 Tank Stack.
When the systems are filled with lubricants, they can easily weight over 2,000 pounds. Use caution while
moving the system around. The system should be empty when moving. Use the appropriate equipment
to move the system around. Please follow the Moving The System procedure in these instructions if the
system needs to be moved.
DO NOT CLIMB on the Trico Spectrum Oil Storage System in anyway. Climbing on the system may cause
the system to tip over and cause severe injury including death. The intended use of the system is to be
fixed to the floor with the mounting holes located in the spill containment pan skid runners, on a flat,
level surface.

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 5 | 20
OVERVIEW
Trico Spectrum Oil Storage Systems are meant to store petroleum-based lubricants in a clean, orderly,
organized, space saving method. The Essential Stack is set up to be expandable up to 6 different tanks
connected to one central motor/pump/manifold/tanks combination. The system is set up to have a
main Pump Stack (Part #37200) with additional Storage Stack (Part #37202) on each side of the Pump
Stack. This would keep the main Pump Stack unit with the pumping system in the middle of the overall
complete system set up. Keeping the motor/pump combination, on/off switch, tank manifold assembly,
and the suction wand centralized in the system for easy use.
Below is an image of the Pump Stack (Part #37200) which will be used for installation purposes. Every
Essential Stack will contain at least one Pump Stack, and up to two additional Storage Stacks (Part
#37202) for up to 6 tanks on one tank manifold.

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 6 | 20
STEP-UP & INSTALLATION
Trico Spectrum Oil Storage Systems come almost fully assembled. They are meant to store petroleum-
based lubricants in a clean, orderly, organized, space saving method. The system only requires the
Watchdog Extreme Humidity Desiccant Breathers attached, the correct electrical outlet to plug the
motor in, and to mount the On/Off switch to make the system usable. If more than 2 tanks were
purchased, installing additional manifold valves, and attaching hoses for the additional tanks will need to
be accomplished as well.
Note:Personal Protective Equipment (“PPE”) should be worn when installing,
operating, and maintaining this system.
Time, Materials, Personnel, and Tool Requirements
•Only one person is need to complete installation.
•Assembly Time is approximately 15 minutes for a standalone Pump Stack unit, an additional 30
minutes required for each add-on Storage Stack unit.
•Electrical hook-ups and installation should be completed by your authorized electrical personal
in accordance with all local, federal, and building regulations.
•A narrow, 22” maximum width, hand pallet truck rated for at least 2,000 lbs can be used to
move each unit into its final position.
•A pipe wrench for 2” pipes is needed for adding additional Storage Stack units to the Tank
Manifold on the Pump Stack unit.
•All fittings already assembled on the system are tightened with thread sealant.
•5/16 nut driver, or a crimp clamp tool, for tightening hose clamps.
•Adjustable crescent wrench for hex plugs on manifold.
System Placement Determination
•The system is recommended for indoor use only.
•The system must be installed on a flat, level surface. The surface must have sufficient load-
bearing capacity to support the total system (each 2-tank Stack weighs 2,000 lbs filled with
lubricant).
•The system can be mounted permanently to the floor using the mounting holes in the Spill
Containment. Mounting will not be covered in this manual and will be the responsibility of the
end user to mount using the correct hardware.
•The electric motor on the Pump Stack has a full load amperage of 17.2A and a separate 20 Amp
circuit is recommended for each Pump Stack. The power cord on the motor is approximately 14
feet in length.
•There should be a minimum of 12” of space from the back of the Spill Containment. This
provides room for the hoses. More room may be required behind the units for maintenance and
easier access to the tank shut-off valves, up to 24”.

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 7 | 20
Attaching Watchdog Extreme Humidity Desiccant Breathers (Part #39141)
1. Remove desiccant breathers from packaging.
2. Remove white elastic band around top of desiccant breather to allow airflow and activate the
desiccant breather.
3. Install desiccant breathers on top of each tank. On top of each tank is a 1/2" NPT tee fitting
where the desiccant breathers will screw into.
Watchdog Extreme Humidity Desiccant Breathers (Part #39141) mounted shown below:
Spectrum Color Coding
The Spectrum Oil Storage System comes with Spectrum color coded tags and tank labels. Please ensure
the tanks, corresponding manifold valves, and corresponding dispensing nozzles are color coded to
easily identify the correct lubricant to dispense and fill. Assigning specific colors allows for a tagging
system to be deployed throughout the lubricant chain within the facility. From the point of storage to
the point of application, the operator will know which designated lubricant is to go to each specific
lubrication point. Color coding lubricants from the time they enter the facility to the point of use will
reduce the amount of lubricant cross contamination and misapplication that occurs in everyday top-ups,
re-lubrication, and re-greasing activities.
39141 Desiccant Breather
39141 Desiccant Breather

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 8 | 20
Mounting the On/Off Motor Switch
The On/Off Switch that controls the motor has been shipped loose, and not attached onto the system.
The power cord connected to the pump has approximately 6 feet before the On/Off Switch. Once the
best place for the On/Off switch is determined, remove the double-sided tape strip on the backside of
the electrical box and mount the On/Off Switch. The On/Off switch is shown below mounted to the
Dispensing Nozzle Bar; however, the switch can be mounted in any location.
NOTE: The electrical cord connecting the On/Off switch to the
motor is not shown in the image above
Powering the Motor/Pump
The electric motor on the Pump Stack has a full load amperage of 17.2A and a separate 20 Amp circuit is
recommended for each Pump Stack. Once the correct outlet has been installed by a certified electrician,
making sure the On/Off switch is in the OFF position, place the NEMA 5-20P plug into the receptacle.
The power cord from the electric motor has approximately 14 feet of cord until the plug.
ON/OFF Switch

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 9 | 20
Adding Additional Storage Stacks (Part #37202) to Expand the System
The Spectrum Essential Oil Storage System is set up to be expandable up to 6 different tanks connected
to one central motor/pump/manifold/tanks combination. The system is set up to have a main Pump
Stack (Part #37200) with additional Storage Stacks (Part #37202) on each side of the Pump Stack. This
would keep the main Pump Stack unit with the pumping system and Tank Manifold in the middle of the
overall complete system set up. Keeping the motor/pump combination, on/off switch, tank manifold
assembly, and the suction wand centralized in the system for easy use.
Below is an image of a 6-Tank System containing one Pump Stack (Part #37200) and two additional
Storage Stacks (Part #37202).
The Pump Stack (Part #37200) comes with the two center Tank Manifold locations fitted with the tank
fill hosing for the upper and lower tanks on the Pump Stack, above the Motor/Pump.
Tank Manifold
Upper/Lower Tank
Hose Connections

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 10 | 20
Each Storage Stack (Part #37202) comes with two Tank Manifold Valve Assemblies, two hose barbs, and
both two hose clamps and two pinch clamps.
To attach the Tank Manifold Valve Assemblies:
1. Remove corresponding Hex Plugs from Tank Manifold to the location of the corresponding
Storage Rack location will be – 2 from LEFT or RIGHT of center. Below all 4 are shown being
removed for a 6-Tank system.
2. Attach the Tank Manifold Valve Assemblies to the Tank Manifold, starting from the center and
working your way outward. Make sure to use a thread sealant on the fittings during assembly.
Hose Barb
Tank Manifold
Valve Assembly
Tank Manifold
Valve Assembly
Tank Manifold
Tank Manifold
Hex Plugs

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 11 | 20
3. Attach the hose barbs onto the Tank Manifold Valve Assemblies. Make sure to use a thread
sealant on the fittings during assembly.
4. Attach the hoses from the Storage Rack onto the hose barbs on the Tank Manifold Valves. The
correct tank orientation is shown below. The upper tanks normally are the LEFT dispensing
nozzle and LEFT Tank Manifold Valve Assembly. Use either provide hose clamps, or pinch
clamps, to attach the hose securely to the hose barb.
Tank Manifold
Valve Assembly
Hose Barb

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 12 | 20
OPERATION INSTRUCTIONS
Filling Storage Tank
WARNING: The Tank Shut-Off valve, located under the tank, must be in the open
position when operating the system.
1. Locate the Tank Shut-Off valve and open it for each tank. Valve locations are shown below
looking from the back of the system.
2. Do not fill the tank with 55 gallons until there is room in the tank. The lubricant level should be
at the bottom of the lowest Viewport on the tank before refilling the tanks. As noted below, the
approximate remaining gallons at the center of the tank’s Viewports are shown.
Center of Lower
Viewport
9 Gallons
Remain
Center of Middle
Viewport
33 Gallons
Remain
Center of Upper
Viewport
57 Gallons
Remain
Upper Tank
Shut-Off Valve
Lower Tank
Shut-Off Valve

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 13 | 20
WARNING: Do not overfill the Tank. Confirm there is enough room in tank before re-
filling with a drum. Best practice is to empty the tank before re-filling.
3. Once the tank has been emptied or confirmed to fit a drum or whatever size lubricant refill, it is
now safe to fill the tank. Place the drum, or similar container, of the lubricant to be filled next to
the Pump Stack or suction wand of the system.
4. Attach the appropriate static discharge cabling per National Fire Protection Code 77 to prevent
static discharge from filling. Ground and bond wires must have less than one-ohm resistance for
safe usage. Check continuity before starting (NOTE: Cabling is not provided).
5. Lift out suction wand from holder and make sure the wand is clean of any contamination. Then
insert suction wand into the full drum of lubricant to be transferred.
6. On the Tank Manifold, close the valves to the tanks (upper valves), and open the drain valve
(lower valve) to flush the manifold of any other product. This flushing is to prevent cross-
contamination of different lubricants into the storage tank.
7. Start the self-priming gear pump by flipping the On/Off Switch to the “ON” position. The
lubricant is now pumped from the drum, through the manifold, and out the drain hose. Once
the lubricant is seen in the drain hose, and no other products contaminating the new lubricant,
close the drain valve.
8. Once the drain valve is closed, open the correct corresponding tank valve where the lubricant
will be stored. Now the lubricant should be transferred from the drum to the tank through the
Tank Manifold.
CAUTION: Never leave pump unattended while using the system and the pump is
powered ON.
Suction Wand
Cross-Contamination
Drain Valve
Tank Manifold
Tank Fill Valves

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 14 | 20
9. As the lubricant is being filled, check the Tank Viewports to avoid over-filling. Do not over fill the
system tank, this will cause damage to the Watchdog Desiccant Breather.
10. To remove the remaining few gallons from the drum, tip the drum at approximately 30 degrees,
with the suction tube placed at the bottom most portion of the drum. The positive displacement
pump will completely evacuate all lubricant from the drum.
11. When the drum, or container, is empty, lift the suction wand out of the drum and allow the
pump to pull any residual oil remaining in the hose out. Then turn the On/Off Switch to the
“OFF” position.
12. Remove suction wand from empty drum, wipe dry and place in holder.
13. On the Tank Manifold, close the valve to the tank (upper valves). This will prevent any access
lubricant in the hose system to drain into the Tank manifold. This step also helps with the
prevention of cross-contamination between lubricants on the next fill.
14. Remove the static discharge cabling and dispose of the empty drum appropriately.
Note: It is normal for air to be trapped inside the hoses during the initial filling of the
system. Once the air bubbles have passed thru the system, fluid should be dispensed
normally. If air bubbles continue to persist after initial fill, there may be a problem
with a fitting, connection, or hosing.
Dispensing Lubricant
1. Place container on Dispensing Area below the correct tank Dispensing Nozzle.
2. Pull Dispensing Nozzle handle towards you, away from the system, to allow lubricant to flow.
3. Release Dispensing Nozzle handle and the flow will stop.
CAUTION:Pinch Point possible when releasing dispensing Nozzle handle.
Dispensing Area
Dispensing Nozzle

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 15 | 20
MAINTENANCE CHECKLIST
Trico Spectrum Oil Storage Systems should have scheduled, routine maintenance every three months
after installation. Personal Protective Equipment (“PPE”) should be worn when performing any
maintenance service on the system.
CAUTION: The Tank Shut-Off valves, located under the tank, must be in the closed
position when servicing the system. Main power supply should be removed and
locked out before any service is performed.
Check and replace Watchdog Extreme Humidity Desiccant Breathers. The orange beads will turn
dark green indicating the desiccant has been used.
Inspect all hoses for crack or kinks
Inspect all fitting for leaks
Inspect and tighten all bolts as needed
Clean all surfaces and motor
Empty Spill Containment pan either by the 1” NPT hole on bottom of pan, or by using the
suction wand and discharge valve into a separate container
MOVING THE SYSTEM
Trico Spectrum Oil Storage Systems can be easily moved around with a hand pallet truck, or forklift.
Follow the procedures below to relocate the system.
1. Empty all Tanks and hoses.
2. Close Tank Shut-Off Valves on the bottom of the Tanks.
3. Close all valves on the Tank Manifold on the Pump Stack.
4. Remove any additional Storage Stack hoses from the Tank Manifold.
5. Disconnect the power by removing the electrical plug at the outlet or turn the power off at the
breaker to each motor.
6. Empty and clean out Spill Containment.
7. Remove bolts from surface mounting holes, if mounted.
8. Move System into new location using a hand pallet truck or forklift. There should be a minimum
of 12” of space from the back of the Spill Containment. This provides room for the hoses. More
room may be required behind the units for maintenance and easier access to the tank shut-off
valves, up to 24”.
9. Once in place, continue with normal installation steps.

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 16 | 20
TROUBLESHOOTING
The following troubleshooting guide gives issues, causes, and corrective action. If any of these actions do
not solve the issue entirely, please contact Trico for additional support.
Symptom
Possible Cause(s)
Corrective Action
Pump system does not
prime
Suction wand above liquid
Ensure open end of suction wand remains
completely below surface of liquid
Clogged suction wand
and/or discharge hose line
and/or manifold valves are
closed
Clean suction wand and/or discharge hose line
and/or open manifold valves
Suction wand line too long
Reduce length in suction line to reduce pressure
Insufficient flow
Clogged/ kinked discharge
hose line or nozzle
Remove and flush discharge hose line and
nozzle, inspect for damage
Fluid viscosity exceeds
recommended viscosity for
motor
Check viscosity of fluid at temperature. See SUS
vs. Temp. chart or contact fluid supplier. If
viscosity exceeds maximum cSt, fluid must be
warmed to reduce viscosity
Fluid Leaking from
manifold or any fittings
Loose fittings and/or
connections
Check tightness of hose/fitting connections
Electric motor does not
function/ or stops
working
Power On/Off switch not
fully switched
Check On/Off switch
No power to receptacle
Check outlet for power and breaker
Unit has overheated
tripping internal overload
breaker
Turn unit power to the “OFF” position, allow
motor to cool, turn back to “ON” position and
resume filling
Unit generates excessive
heat
Fluid viscosity exceeds maximum recommended
viscosity
Tank is not filling
Tank Manifold Valve is
closed
Open Correct Tank Manifold Valve
Tank is not dispensing
fluid
Tank Shut-Off Valve is
closed
Open Tank Shut-Off Valve below the tank to
have gravity feed for the Dispensing Nozzle
Dispensing Nozzle is
clogged
Clean Dispensing Nozzle to remove
contamination or clogs

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 17 | 20
REPLACEMENT PARTS
Item #
Part Number
Description
Qty
1
39141
Watchdog Extreme Humidity Desiccant Breather
2
2
34307
1" NPT Viewport with Baffle - Steel
6
3
18363
1” NPT Dispensing Nozzle - Brass
2
4
18313
Dispensing Area Expanded Metal PVC Coated Mesh
1
5
18337
Tank Manifold T-Handle Valve, 1" NPT, Brass
Up to 7
Below Tanks
18354
Tank Shut-Off Valve, 1" NPT, Brass
2

Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008 Page 18 | 20
TEMPERATURE VS. VISCOSITY
Table of contents
Other Trico Storage manuals
Popular Storage manuals by other brands

Salsbury Industries
Salsbury Industries 18-51000 Series installation instructions

Exabyte
Exabyte 110L LTO Ultrium AUTOLOADER Field Instruction

Seagate
Seagate ST8000VX000 product manual

Panasonic
Panasonic JU-314 Service manual

Hitachi
Hitachi Ultrastar HUS103030FL3600 install guide

IBM
IBM FC 5026 installation instructions

Hitachi
Hitachi Travelstar 7K100 Quick installation guide

Sun Microsystems
Sun Microsystems Sun StorEdge 3900 Series Site preparation guide

Synology
Synology DS3611xs Quick installation guide

Seagate
Seagate FreeAgent Go Product information

Qsan
Qsan XCubeSAN XS5224D user manual

Sony
Sony SRR1000 installation manual