Unisolar 20.24 W
IMPORTANT
Dust and dirt on the glass face reduce power production. Clean regularly your panel,
using a soft cloth or a soft brush and soapy water (corrosive products banished).
Setting up Unisun modules in direct contact with the roof (without Unifix mounting
bracket) is banished.
Panel coupling: couple panels with equivalent powers (3 panels maximum).
EN
UNISUN - UNICONNECT
Uniconnect : fast solar connection kits
Unisun : high-performance solar modules
!

UNISUN PANELS : TECHNICAL SPECIFICATIONS
2/16 www.uniteck.fr
Dear customers, thank you very much for purchasing. Please read carefully and thoroughly all the
instructions before using the product.
Unisun is the high-performance monocrystalline module range for leisure applications (boating, camper
van), off-grid or signs.
Their multi-layer structure ensures an exceptional performance even in case of low sunshine or heat
conditions. Their high transmissibility tempered glass and their anodized aluminium frame preserve them
from external attacks (impacts, oxidation, corrosion).
With their anti hot-spot system, the panels are protected against the hotspot effects that can occur with
cells occupation.
The Unisun range is composed of compact panels which optimize the available space. Adjustable for more
power, connecting them in series or parallel is facilitated by their MC4-type solar connectors.
For the module/solar charge controller/battery connection, we recommend the Uniconnect ready-to-use
kits which optimize your electrical performances and make your installation easier:
- Uniconnect 1.6 = 1 module connection
- Uniconnect 2.6 = 2 modules connection
- Uniconnect 3.6 = 3 modules connection
SAFETY INSTRUCTIONS
Take appropriate measures to prevent accidents during the mounting work.
If the module or the bracket are exposed to sunlight for a long time, there is a risk of burns. Protect
yourself.
Once the work is achieved, check that your mounting brackets and modules are perfectly fixed.
During the maintenance, please disconnect the solar system. Connection cables must never be
powered up: risk of electrical arc.
RECOMMENDATIONS
Set the Unisun modules on surfaces presenting a sufficient lift. Consider the extra charge with module
+ bracket.
The placement of the sensors influences your electrical performances. Choose the optimal
inclination and orientation depending on your environment. Avoid shadow areas or objects sources
of shade.
Dust and dirt on the glass face reduce power production. Clean regularly your panel, using a soft
cloth or a soft brush and soapy water (corrosive products are banished).
Check regularly the quality of your module connections.

UNISUN PANELS : OVERVIEW AND WIRING
3/16 www.uniteck.fr
Before fixing and connecting, please respect :
- the maximum distances (indicated below between each element)
- the connection order
Unisun + Uniconnect Wiring
(1) The distance between modules can be extended with one additional meter by adding a 612B and a 612R
Unicable (additional cables not provided with Uniconnect kits, optional).
(2) Battery connexion kit 2 (not provided with Uniconnect kit, optional)
Series/parallel connection
Connection order
To disconnect, follow the opposite order. For more details, refer to the manual of your solar charge controller.
Module 3
Module 2
Module 1
Roof pass
Solar charge
controller
Battery
1 m
max(1)
1 m
max(1)
8 m max
2 m max
4 m
max (2)
1
2
1
Connection : solar charge controller battery
Connection : module solar charge controller
Connection : solar charge controller electrical device
Parallel connection
for more output power (W)
12V/50W + 12V/80W= 12V/110W
Series connection
for your 24V batteries :
12V/50W +12V/50W= 24V/50W

UNISUN PANELS : TECHNICAL SPECIFICATIONS
4/16 www.uniteck.fr
Distance between screws
COMPLIANCE STATEMENT
UNITECK testifies that the modules described in this manual :
UNISUN 5.12M / 10.12P / 10.12M / 20.12M / 50.12M / 80.12M / 100.12M / 145.12M are
manufactured in compliance with the European directives.
It complies with the harmonised standards:
- IEC 61215 & IEC 61730
CE date of tagging: January 2013.
01/01/2013 Yoann Fourmond
Société Uniteck General Manager
132 rue Pierre Simon Marquis de Laplace
34500 Béziers
WARRANTY
The warranty covers all defects or manufacturing flaws for 1 year from the day of purchase (pieces and
workforce).
The warranty does not cover:
- the normal wear of the pieces (for ex.: cables, etc.).
- incidents due to a bad use, fall, disassembly, or any other damage due to the transport.
In case of failure, return the device to your supplier, and join :
- a dated proof of purchase (cashier’s receipt, bill…).
- an explanatory note of the failure.
Caution : Our after-sales service does not accept postage due returns.
After the warranty, our after-sales service ensures repairs after acceptance of a quotation.
After-sales service contact : Uniteck-132 rue Pierre Simon Marquis de Laplace
34500 Béziers -France
E-mail: sav@uniteck.fr Fax: +33 (0)4 88 04 72 20
Unisun
5.12M
Unisun
10.12P
Unisun
10.12M
Unisun
20.12M
Unisun
20.24M
Unisun
50.12M
Unisun
80.12M
Unisun
100.12M
Unisun
145.12M
Distance of
fixation W
x H (mm)
140 x 195
289x188
120x34
183x34
420x260
120x260
420x260
120x260
420 x 500
120 x 500
860 x 500
127 x 500
860 x 500
127 x 500
1100 x 626
600 x 626

UNISUN PANELS : TECHNICAL SPECIFICATIONS
5/16 www.uniteck.fr
UNISUN
5.12M
UNISUN
10.12P
UNISUN
10.12M
UNISUN
20.12M
UNISUN
20.24M
Performance
Max power (Pm)*
5 W
10 W
10 W
20 W
20 W
Power range*
0/+3%
0/+3%
0/+3%
0/+3%
0/+3%
Operating voltage
12 V
12 V
12V
12 V
24 V
Technology
Mono.
Poly.
Mono.
Mono.
Mono.
Voltage at maximum power (Vmp)*
17,4 V
17,4 V
17,6 V
17,6 V
35,2 V
Intensity at maximum power (Imp)*
0,29 A
0,57 A
0,57 A
1,14 A
0,57 A
Open circuit voltage (Voc)
21,6 V
21,6 V
21,77 V
21,7 V
43,54 V
Short circuit current (Icc/Isc)
0,32 A
0,65 A
0,65 A
1,26 A
0,65 A
Min. intensity charge controller IMR
(=IMP +25%)
0,36 A
0,71 A
0,71 A
1,43 A
0,71 A
Solar cells efficiency
18 %
17 %
18,4%
15,8 %
18,4 %
Solar module efficiency
7,5 %
8,8 %
12,5 %
10,8 %
12,5 %
Temperature sensitivity
Operating temperature
-40 °C to
+85°C
-40 °C to
+85°C
-40 °C to
+85°C
-40 °C to +80
°C
-40 °C to
+85°C
NOCT/TUC**
45 +/- 2°C
45 +/- 2°C
45 +/- 2°C
45 +/- 2°C
45 +/- 2°C
Temperature ratio :
- Pm :
- Voc :
- Icc :
-0,48 %/°C
-0,34 %/°C
0,037 %/°C
-0,47 %/°C
-0,34 %/°C
0,045 %/°C
-0,48%/C°
-0,34%/C°
0,037%/C°
-0,50 %/°C
-0,35 %/°C
-0,060 %/°C
-0,48%/C°
-0,34%/C°
0,037%/C°
Mechanical characteristics
Cells dimensions
62,5 x
15,6mm
78 x 26 mm
62,5 x 31,25
mm
62,5 x
62,5mm
125 x 15,5
mm
Number of cells
36 (4x9)
36 (4x9)
36 (4x9)
36 (4x9)
72 (4x18)
Module dimension
216 x 306
x 18 mm
310 x 368
x 18 mm
310 x 383 x
35 mm
660 x 310
x 35 mm
310 x 660 x
35 mm
Cable length
-
-
900 mm
300 mm
900 mm
Module weight
0,8 kg
1,5 kg
1,5 kg
2,5 kg
2,5 kg
* Under standard test conditions (STC) : sunshine - 1 000 W/m2, AM 1.5, cells temperatures (25 °C)
** Nominal operating cell temperature : sunshine - 800 W/m²,
With an ambient temperature of 25 °C and a wind of 1 m/s.

UNISUN PANELS : TECHNICAL SPECIFICATIONS
6/16 www.uniteck.fr
UNISUN
50.12M
UNISUN
80.12M
UNISUN
100.12M
UNISUN
145.12M
Performance
Max power (Pm)*
50 W
80 W
100 W
145 W
Power range*
0/+3%
0/+5%
0/+3%
0/+3%
Operating voltage
12 V
12 V
12 V
12 V
Technology
Monocrystaline
Monocrystaline
Monocrystaline
Monocrystaline
Voltage at maximum power
(Vmp)*
18,5 V
17,5V
18,7 V
18,15 V
Intensity at maximum power
(Imp)*
2,7 A
4,57 A
5,43 A
7,99 A
Open circuit voltage (Voc)
22,7 V
21,9 V
22,4 V
21,72 V
Short circuit current (Icc/Isc)
2,84 A
4,95 A
5,66 A
8,41 A
Min. intensity charge
controller IMR
(=IMP +25%)
3,38 A
5,71 A
6,78 A
9,98 A
Solar cells efficiency
18,8 %
15,8 %
18,5 %
18.4%.
Solar module efficiency
14,2 %
12,10 %
15,5 %
15.2%
Temperature sensitivity
Operating temperature
-40 °C to +80 °C
-40 °C to +80 °C
-40 °C to +85 °C
-40 °C to +85 °C
NOCT/TUC**
45 +/- 2°C
45 +/- 2°C
45 +/- 2°C
45 +/- 2°C
Temperature ratio :
- Pm :
- Voc :
- Icc :
-0,50 %/°C
-0,35 %/°C
0,060 %/°C
-0,50 %/°C
-0,35 %/°C
0,060 %/°C
-0,48 %/°C
-0,34 %/°C
0,037 %/°C
-0,48 %/°C
-0,34 %/°C
0,037 %/°C
Mechanical characteristics
Cells dimensions
125 x 62,5 mm
156 x 78 mm
125 x 125 mm
156 x 156 mm
Number of cells
36 (4x9)
36 (4x9)
36 (4x9)
36 (4x9)
Module dimension
640 x 550
x 35 mm
960 x 550 x 35
mm
1200 x 550 x 35 mm
1482 x 676 x 35
mm
Cable length
300 mm
300 mm
500 mm
500 mm
Module weight
4,5 kg
7,5 kg
8,0 kg
11,5 kg
* Under standard test conditions (STC) : sunshine - 1 000 W/m2, AM 1.5, cells temperatures (25 °C)
** Nominal operating cell temperature: sunshine - 800 W/m²,
With an ambient temperature of 25 °C and a wind of 1 m/s.

UNICONNECT KIT : MODULE WIRING
7/16 www.uniteck.fr
For the connection module/solar charge controller/battery, we recommend the Uniconnect ready-to-use
kits:
- Uniconnect 1.6 = 1 module connection
- Uniconnect 2.6 = 2 modules connection
- Uniconnect 3.6 = 3 modules connection
Uniconnect kits are equipped with flexible solar cables with a tinned copper core resistant to extreme
conditions (from -40°C to 120°C, UV, immersion…). With its 6 mm² section, it optimizes the output
power of your installation by assuring a minimal voltage drop.
It easily and rapidly fits with panels (MC4-type solar connectors). They include a fuse kit to protect your
installation and your battery and are supplied with a waterproof roof-pass (UV resistant), battery
terminals and cable guides.
OVERVIEW OF THE UNICONNECT WIRING
Connection
inter-module
Connection
module /charge controller
Connection
Charge controller/battery
Guide
cables
Unicable
612 B + 612 R
(1 meter)
Bypass kit
Unicable
681 B + 681 R
(8 meters)
Roof
Pass(3)
Connection kit battery 1
With battery terminals
+ fuse protection kit
Guides
cables(4)
Uniconnect 3.6
x 2
x 2
x1
x1
x1
x 2
Uniconnect 2.6
x 1
x 1
x1
x1
x1
x 4
Uniconnect 1.6
-
x1
x1
x1
x 6
(1) The distance between modules can be extended with one additional meter by adding a 612B and a 612R
Unicable (additional cables not provided with Uniconnect kits, optional).
(2) Battery connexion kit 2 (not provided with Uniconnect kit, optional)
(3) The roof pass is made to be sticked. To ensure sealing, use the adhesive included in the Unifix 1C kit or a
sealing adhesive.
(4) Cable guides allows you to guide and fix your cables
Module 3
Module 2
Module 1
Roof pass
Solar charge
controller
Battery(ies)
1 m
max(1)
1 m
max(1)
8 m max
2 m max
4 m
max(2)
1
2

UNICONNECT KIT : MODULE WIRING
8/16 www.uniteck.fr
Please respect the following connection order :
To disconnect, please follow the opposite order. For more details, refer to the manual of your photovoltaic
solar charge controller.
ZOOM INTER-MODULE CONNECTION (SERIES CONNECTION)
Uniconnect 1.6
NB : For the pannel connection, remove plugs placed at the end of your cables. Keep them for protecting
your cables when you disconnect your modules (ex. : for your cleaning/maintenance operations).
x2
x2
x2
1
Connection : solar charge controller -> battery
Connection : module -> solar charge controller
Connection : solar charge controller -> electrical load

UNICONNECT KIT : MODULE WIRING
9/16 www.uniteck.fr
Uniconnect 2.6
nb : For the pannel connection, remove plugs placed at the end of your cables. Keep them for protecting
your cables when you disconnect your modules (ex. : for your cleaning/maintenance operations)
x1
x1
x3
x3
x 4

UNICONNECT KIT : MODULE WIRING
10/16 www.uniteck.fr
Uniconnect 3.6
nb : For the pannel connection, remove plugs placed at the end of your cables. Keep them for protecting
your cables when you disconnect your modules (ex. : for your cleaning/maintenance operations)
x2
x2
x4
x4
X6

UNICONNECT KIT : ROOF PASS INSTALLATION
11/16 www.uniteck.fr
Follow these instructions :
Drill the wall with a hole saw. Diameter between 15 and 20mm.
Roof pass fixing :
- For a vehicle use with Unifix 1C kit:
Clean the selected area with the degreaser supplied with the Unifix 1C kit (do not use alcohol/
white spirit...).
Apply the adhesive supplied with your Unifix 1.C bracket on the white area shown (see image
below). Then place it on the drilled place.
-For a use on roof/wall: fix your roof pass using 2 self-strapping screws.

UNICONNECT KIT : ROOF PASS INSTALLATION
12/16 www.uniteck.fr
Pass the cables. Keep a sufficient length for your wiring. Tighten the nuts from the gland to ensure
impermeability.
Close the cover with 2 plastic screws.
Connect the connectors together. (No risk of mistakes, the connectors are polarized).
x2

UNICONNECT KIT : BATTERY KIT N°1 ASSEMBLY
13/16 www.uniteck.fr
Battery kit n°1 : Assemble the red cables and the fuse kit.
Battery kit n°1 : Add the terminals using the wing nut. If desired, you can fix the fuse kit with the
provided self-tapping screw.
D8 Terminal
L= 2m
x 1
L= 1,7m
D5 Terminal
x 1
L=0,3
D5 Terminal/ D8 Terminal
x 1
x 1
L = 2m
L = 1,7m
L = 0,3m

UNICONNECT KIT : BATTERY KIT ASSEMBLY N°2 (OPTIONAL)
14/16 www.uniteck.fr
With its 2 battery outputs, the battery kit n°2 (optional) links the Unisolar 20-24D, which has 2
battery outputs, to your second battery. Its 4 m cable makes easier the connection between your
Unisolar charge controller and your starter battery (located in the engine compartment).
Put the red cables and the fuse kit together.
Add terminals using the wing nut. If desired, you can fix the fuse kit using the provided self-tapping
screw.
D8 Terminal
L= 4m
x 1
L= 3,2m
D5 Terminal
x 1
L=0,8
D5 Terminal/ D8 Terminal
x 1
x 1
L = 2m
L = 1,7m
L = 0,3m

UNICONNECT KIT : BATTERY KIT ASSEMBLY N°2 (OPTIONAL)
15/16 www.uniteck.fr
Battery kit n°1 : Link your connection kit to the battery output of your solar charge controller and
then to your battery 1.
Battery kit n°2 (optional) : link your connection kit to the second battery of your Unisolar 20-24D
solar charge controller and then to your battery 1.

UNICONNECT KIT : TECHNICAL SPECIFICATIONS
16/16 www.uniteck.fr
UNICONNECT
Cables section
6 mm²
Conductor
Flexible class 5/6
Outer sheath
Fireproof rubber
EM8 type, without halogen type E16 with low smoke
and corrosive gases in case of fire
Cable resistance
- water
- operating temperature
- in short circuit (5 sec)
- uv
- impacts
AD7 (immersion)
-40 °C/+120 °C
250 °C
Yes
Average impact (AG2)
Cable norms
EN 60332-1 / EN 50267-1/ EN 50267-2 / EN61034 /
IEC 60332-1 / IEC60754-1 / IEC 60754-2 / IEC 61034
Module connector
MC4-type
Battery connection
Connector
Battery terminals
Fuse
- rating
- centre distance
60 A
30 mm
This manual suits for next models
13
Table of contents
Popular Control Unit manuals by other brands

Buderus
Buderus EM100 Installation instructions for skilled labour

Ensemble Designs
Ensemble Designs Avenue 5030 user guide

Eaton
Eaton Series NRX installation instructions

Asus
Asus AAEON NIM-S13A Quick installation guide

Texas Instruments
Texas Instruments DAC8771EVM user guide

Polycom
Polycom SoundPoint IP 670 quick start guide