Maxsys PC4820 v1.4 User manual

PC4820 v1.4
PC4820 v1.4PC4820 v1.4
PC4820 v1.4 • Installation Manual
Installation ManualInstallation Manual
Installation Manual
WARNING: This manual contains information on limitations
regarding product use and function and information on the
limitations as to liability of the manufacturer. The entire
manual should be carefully read.

Limited Warranty
Digital Security Controls Ltd. warrants the original purchaser that for a period of twelve months
from the date of purchase, the product shall be free of defects in materials and workmanship
under normal use. During the warranty period, Digital Security Controls Ltd. shall, at its option,
repair or replace any defective product upon return of the product to its factory, at no charge for
labour and materials. Any replacement and/or repaired parts are warranted for the remainder of
the original warranty or ninety (90) days, whichever is longer. The original purchaser must
promptly notify Digital Security Controls Ltd. in writing that there is defect in material or work-
manship, such written notice to be received in all events prior to expiration of the warranty
period. There is absolutely no warranty on software and all software products are sold as a user
license under the terms of the software license agreement included with the product. The Cus-
tomer assumes all responsibility for the proper selection, installation, operation and maintenance
of any products purchased from DSC. Custom products are only warranted to the extent that
they do not function upon delivery. In such cases, DSC can replace or credit at its option.
International Warranty
The warranty for international customers is the same as for any customer within Canada and the
United States, with the exception that Digital Security Controls Ltd. shall not be responsible for
any customs fees, taxes, or VAT that may be due.
Warranty Procedure
To obtain service under this warranty, please return the item(s) in question to the point of pur-
chase. All authorized distributors and dealers have a warranty program. Anyone returning goods
to Digital Security Controls Ltd. must first obtain an authorization number. Digital Security
Controls Ltd. will not accept any shipment whatsoever for which prior authorization has not
been obtained.
Conditions to Void Warranty
This warranty applies only to defects in parts and workmanship relating to normal use. It does
not cover:
• damage incurred in shipping or handling;
• damage caused by disaster such as fire, flood, wind, earthquake or lightning;
• damage due to causes beyond the control of Digital Security Controls Ltd. such as excessive voltage,
mechanical shock or water damage;
• damage caused by unauthorized attachment, alterations, modifications or foreign objects;
• damage caused by peripherals (unless such peripherals were supplied by Digital Security Controls
Ltd.);
• defects caused by failure to provide a suitable installation environment for the products;
• damage caused by use of the products for purposes other than those for which it was designed;
• damage from improper maintenance;
• damage arising out of any other abuse, mishandling or improper application of the products.
Items Not Covered by Warranty
In addition to the items which void the Warranty, the following items shall not be covered by
Warranty: (i) freight cost to the repair centre; (ii) products which are not identified with DSC's
product label and lot number or serial number; (iii) products disassembled or repaired in such a
manner as to adversely affect performance or prevent adequate inspection or testing to verify any
warranty claim. Access cards or tags returned for replacement under warranty will be credited
or replaced at DSC's option. Products not covered by this warranty, or otherwise out of warranty
due to age, misuse, or damage shall be evaluated, and a repair estimate shall be provided. No
repair work will be performed until a valid purchase order is received from the Customer and a
Return Merchandise Authorisation number (RMA) is issued by DSC's Customer Service.
Digital Security Controls Ltd.’s liability for failure to repair the product under this warranty after
a reasonable number of attempts will be limited to a replacement of the product, as the exclusive
remedy for breach of warranty. Under no circumstances shall Digital Security Controls Ltd. be
liable for any special, incidental, or consequential damages based upon breach of warranty,
breach of contract, negligence, strict liability, or any other legal theory. Such damages include,
but are not limited to, loss of profits, loss of the product or any associated equipment, cost of
capital, cost of substitute or replacement equipment, facilities or services, down time, pur-
chaser’s time, the claims of third parties, including customers, and injury to property. The laws
of some jurisdictions limit or do not allow the disclaimer of consequential damages. If the laws
of such a jurisdiction apply to any claim by or against DSC, the limitations and disclaimers con-
tained here shall be to the greatest extent permitted by law. Some states do not allow the exclu-
sion or limitation of incidental or consequential damages, so that the above may not apply to
you.
Disclaimer of Warranties
This warranty contains the entire warranty and shall be in lieu of any and all other warranties,
whether expressed or implied (including all implied warranties of merchantability or fitness for a
particular purpose) and of all other obligations or liabilities on the part of Digital Security Con-
trols Ltd. Digital Security Controls Ltd. neither assumes responsibility for nor authorizes any
other person purporting to act on its behalf to modify or to change this warranty, nor to assume
for it any other warranty or liability concerning this product.
This disclaimer of warranties and limited warranty are governed by the laws of the province of
Ontario, Canada.
WARNING: Digital Security Controls Ltd. recommends that the entire system be completely tested on
a regular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering
or electrical disruption, it is possible for this product to fail to perform as expected.
Out of Warranty Repairs
Digital Security Controls Ltd. will at its option repair or replace out-of-warranty products which
are returned to its factory according to the following conditions. Anyone returning goods to Dig-
ital Security Controls Ltd. must first obtain an authorization number. Digital Security Controls
Ltd. will not accept any shipment whatsoever for which prior authorization has not been
obtained.
Products which Digital Security Controls Ltd. determines to be repairable will be repaired and
returned. A set fee which Digital Security Controls Ltd. has predetermined and which may be
revised from time to time, will be charged for each unit repaired.
WARNINGPlease Read Carefully
Note to Installers
This warning contains vital information. As the only individual in contact with system users, it is your
responsibility to bring each item in this warning to the attention of the users of this system.
System Failures
This system has been carefully designed to be as effective as possible. There are circumstances, how-
ever, involving fire, burglary, or other types of emergencies where it may not provide protection. Any
alarm system of any type may be compromised deliberately or may fail to operate as expected for a vari-
ety of reasons. Some but not all of these reasons may be:
Inadequate Installation
A security system must be installed properly in order to provide adequate protection. Every installation
should be evaluated by a security professional to ensure that all access points and areas are covered.
Locks and latches on windows and doors must be secure and operate as intended. Windows, doors,
walls, ceilings and other building materials must be of sufficient strength and construction to provide the
level of protection expected. A reevaluation must be done during and after any construction activity. An
evaluation by the fire and/or police department is highly recommended if this service is available.
Criminal Knowledge
This system contains security features which were known to be effective at the time of manufacture. It is
possible for persons with criminal intent to develop techniques which reduce the effectiveness of these
features. It is important that a security system be reviewed periodically to ensure that its features remain
effective and that it be updated or replaced if it is found that it does not provide the protection expected.
Access by Intruders
Intruders may enter through an unprotected access point, circumvent a sensing device, evade detection
by moving through an area of insufficient coverage, disconnect a warning device, or interfere with or
prevent the proper operation of the system.
Power Failure
Control units, intrusion detectors, smoke detectors and many other security devices require an adequate
power supply for proper operation. If a device operates from batteries, it is possible for the batteries to
fail. Even if the batteries have not failed, they must be charged, in good condition and installed cor-
rectly. If a device operates only by AC power, any interruption, however brief, will render that device
inoperative while it does not have power. Power interruptions of any length are often accompanied by
voltage fluctuations which may damage electronic equipment such as a security system. After a power
interruption has occurred, immediately conduct a complete system test to ensure that the system oper-
ates as intended.
Failure of Replaceable Batteries
This system’s wireless transmitters have been designed to provide several years of battery life under
normal conditions. The expected battery life is a function of the device environment, usage and type.
Ambient conditions such as high humidity, high or low temperatures, or large temperature fluctuations
may reduce the expected battery life. While each transmitting device has a low battery monitor which
identifies when the batteries need to be replaced, this monitor may fail to operate as expected. Regular
testing and maintenance will keep the system in good operating condition.
Compromise of Radio Frequency (Wireless) Devices
Signals may not reach the receiver under all circumstances which could include metal objects placed on
or near the radio path or deliberate jamming or other inadvertent radio signal interference.
System Users
A user may not be able to operate a panic or emergency switch possibly due to permanent or temporary
physical disability, inability to reach the device in time, or unfamiliarity with the correct operation. It is
important that all system users be trained in the correct operation of the alarm system and that they
know how to respond when the system indicates an alarm.
Smoke Detectors
Smoke detectors that are a part of this system may not properly alert occupants of a fire for a number of
reasons, some of which follow. The smoke detectors may have been improperly installed or positioned.
Smoke may not be able to reach the smoke detectors, such as when the fire is in a chimney, walls or
roofs, or on the other side of closed doors. Smoke detectors may not detect smoke from fires on another
level of the residence or building.
Every fire is different in the amount of smoke produced and the rate of burning. Smoke detectors cannot
sense all types of fires equally well. Smoke detectors may not provide timely warning of fires caused by
carelessness or safety hazards such as smoking in bed, violent explosions, escaping gas, improper stor-
age of flammable materials, overloaded electrical circuits, children playing with matches or arson.
Even if the smoke detector operates as intended, there may be circumstances when there is insufficient
warning to allow all occupants to escape in time to avoid injury or death.
Motion Detectors
Motion detectors can only detect motion within the designated areas as shown in their respective instal-
lation instructions. They cannot discriminate between intruders and intended occupants. Motion detec-
tors do not provide volumetric area protection. They have multiple beams of detection and motion can
only be detected in unobstructed areas covered by these beams. They cannot detect motion which occurs
behind walls, ceilings, floor, closed doors, glass partitions, glass doors or windows. Any type of tamper-
ing whether intentional or unintentional such as masking, painting, or spraying of any material on the
lenses, mirrors, windows or any other part of the detection system will impair its proper operation.
Passive infrared motion detectors operate by sensing changes in temperature. However their effective-
ness can be reduced when the ambient temperature rises near or above body temperature or if there are
intentional or unintentional sources of heat in or near the detection area. Some of these heat sources
could be heaters, radiators, stoves, barbeques, fireplaces, sunlight, steam vents, lighting and so on.
Warning Devices
Warning devices such as sirens, bells, horns, or strobes may not warn people or waken someone sleep-
ing if there is an intervening wall or door. If warning devices are located on a different level of the resi-
dence or premise, then it is less likely that the occupants will be alerted or awakened. Audible warning
devices may be interfered with by other noise sources such as stereos, radios, televisions, air condition-
ers or other appliances, or passing traffic. Audible warning devices, however loud, may not be heard by
a hearing-impaired person.
Telephone Lines
If telephone lines are used to transmit alarms, they may be out of service or busy for certain periods of
time. Also an intruder may cut the telephone line or defeat its operation by more sophisticated means
which may be difficult to detect.
Insufficient Time
There may be circumstances when the system will operate as intended, yet the occupants will not be
protected from the emergency due to their inability to respond to the warnings in a timely manner. If the
system is monitored, the response may not occur in time to protect the occupants or their belongings.
Component Failure
Although every effort has been made to make this system as reliable as possible, the system may fail to
function as intended due to the failure of a component.
Inadequate Testing
Most problems that would prevent an alarm system from operating as intended can be found by regular
testing and maintenance. The complete system should be tested weekly and immediately after a break-
in, an attempted break-in, a fire, a storm, an earthquake, an accident, or any kind of construction activity
inside or outside the premises. The testing should include all sensing devices, keypads, consoles, alarm
indicating devices and any other operational devices that are part of the system.
Security and Insurance
Regardless of its capabilities, an alarm system is not a substitute for property or life insurance. An alarm
system also is not a substitute for property owners, renters, or other occupants to act prudently to pre-
vent or minimize the harmful effects of an emergency situation.

i
Section 1: Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.1 PC4820 Access Control Module Specifications....................................................................................1
Section 2: Installation and Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.1 Plan Your Installation..........................................................................................................................2
2.2 Installation Steps ................................................................................................................................2
2.3 Inputs – POST, ARM and REX..............................................................................................................2
2.4 Outputs – LED, BUZ and OUT Terminals.............................................................................................3
2.5 Door Locking Devices – LK1 & LK2 Terminals ......................................................................................3
2.6 Access Card Readers...........................................................................................................................3
PC4820 Connection Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
PC4820 List of Supported Readers and Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
PC4820 Access Control Module Reader Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Section 3: Programming the PC4820 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.1 Programming Reader Types ................................................................................................................6
3.2 Reader Options...................................................................................................................................6
3.3 Arming and Disarming with Access Cards...........................................................................................7
3.4 Door Times.........................................................................................................................................7
3.5 Zone Assignment for Access Doors .....................................................................................................7
3.6 Access Door Schedules .......................................................................................................................7
3.7 Access Level .......................................................................................................................................9
3.8 Programming Access Cards ................................................................................................................9
Section 4: Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
4.1 Hardware Reset ................................................................................................................................10
4.2 Diagnostics via VTAL LED (L1) ...........................................................................................................10
Section 5: PC4820 Programming Worksheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Table of Contents

ii
Transformer: 16.5V, 40VA
Example: DSC PTD1640U
DO NOT connect
transformer to receptacle
controlled by a switch.
PRIMARY
50Hz or 60Hz
SECONDARY
16.5VAC, 40VA
Tighten nut to break paint
and make a good connection
to the cabinet
Primary shall be rated
according to the AC Mains
PC4820 Access Control Module
Wiring Diagram

1
Section 1: Introduction
The PC4820 is a versatile Dual Card Reader Access Control
module which will enable you to meet the most demanding
access control requirements of an installation. The PC4820
is monitored and programmed via the PC4010/4020 control
panel. Up to 16 PC4820 modules can be connected to a
PC4010/4020 via a 4-conductor Combus, using standard,
unshielded station wire.
Each PC4820 is capable of providing supervision for two
door inputs which may to assigned to any PC4010/4020
zone. Each door contact may be configured for any zone end
of line option which the control panel can provide.
Each of the two PC4820 Access Card Readers can be pro-
grammed to function independently on different doors, or
together controlling access for both sides of one door.
Control of the access points can be performed using a variety
of equipment. The PC4820 supports four different types of
card readers: the Polaris magnetic stripe reader, the Shadow-
Prox proximity card reader, the HID proximity readers, and
26-bit standard Wiegand card readers. The PC4820 also sup-
ports the use of any request to exit device including the T-
Rex exit detector.
1.1 PC4820 Access Control Module Specifications
Two Zone Inputs
• Two programmable supervised zones
• Zones may be programmed as Standard or Auxiliary delay
zone types
• PC4010/4020: up to 16 PC4820 modules can be added (up
to 32 access points)
Non Volatile RAM (internal memory)
• Does not lose any system programming when the module
is powered down.
Low Current Outputs
Six low current outputs (open collector outputs switched to
ground 25mA max.) :
• Two LED terminals - To the LED input of the reader
• Two BUZ terminals - To the Buzzer input of the reader
• Two OUT terminals - Reserved for future use
Regulated Power Supply ( 1.5 Amp max. )
• Electronic shutdown protection of the battery, auxiliary
output, 5 and 12 V reader power supplies, and lock device
power output
• Auxiliary output supply: 12VDC, 125mA Max
• LK1 and LK2 door strike power: 12VDC, 250mA max
• Reader power 5VDC, 125mA max
• Reader power 12VDC, 125mA max
NOTE: UL has only verified compatibility with the eff-eff
Fritz Fuss model 4104 electric door strike. The 4104 will
fail secure.
Reader Technology
• Polaris, ShadowProx, HID proximity and 26-bit standard
Wiegand format
Access Card Compatibility
• Polaris POL-C1CN - Polaris Magnetic Cards
• Shadow Prox, module numbers:
SH-C1 - ShadowProx card
SH-K1 - ShadowProx keytag
• HID Proximity:
HID-C1325KSF - proximity card
HID-C134KSP - proximity keytag
• Wiegand - standard 26 bit formats
NOTE: UL has only verified compatibility with the Motor-
ola model ASR-500.
Battery
• 12VDC 7.0Ah recommended rechargeable lead acid bat-
tery
Transformer
• 16.5 Vac, 40VA
Operating Temperature
• 0°C to 49°C (32°F to 120°F) operational temperature
range
• 85% ±5% non-condensing relative humidity
Output Voltage
• Output voltage = 13.8VDC (with normal AC and a fully
charged battery). Devices that require power from the
PC4820 should be capable of operation over the voltage
range of 10 to 14VDC.
• 5V Power Supply - Devices connected to the 5V supply
should be capable of operation between 4 and 6V.

2
Section 2: Installation and Wiring
2.1 Plan Your Installation
When designing a security system with access control it is
best to first lay out the system on paper. This will help
determine the total number of zones, additional expanders,
access control points and other system components that
will be required to complete the installation.
When the locations of all points of access are known,
appropriate points may be chosen for access control.
When working from the layout, be sure to locate the
PC4820 module so that the wire runs from each door will
be as short as possible.
When deciding the placement of the access points and
module, remember to check the capacitance limit for the
wire you are using for the Combus. Follow the steps out-
lined in your PC4010/4020 v3.0 Installation Manual (Sec-
tion 2.4 “Capacitance Limits”).
NOTE: Do not run the Combus to the PC4820 in shielded
cable.
2.2 Installation Steps
Once the location of the PC4820 and each access point is
determined, follow the installation steps outlined below.
1 Installation of PC4820 and accessories:
The PC4820 controller cabinet has been designed for sur-
face mounting. The cabinet is large enough to accommo-
date the battery backup supply and the necessary wiring
connections for most applications. The cabinet should be
mounted indoors, in a dry, secure location providing nor-
mal temperature, humidity levels and access to an earth
ground connection. The location should be easily accessi-
ble for servicing the equipment, and it is recommended
that each PC4820 module be near the doors it controls. If
the PC4820 is within the access-controlled area, keys for
the controlled doors must be made available so that the
PC4820 can be accessed for servicing.
Connect the various devices for each access door accord-
ing to the diagram below:
A. Access card readers should be located 107cm (42")
from the floor.
B. Connect door strikes using standard 18-gauge cable.
Recommended door strikes are electric continuous
duty devices which, when power is cut, will remain in
a locked or secured state. When using magnetic locks,
follow local regulations on the use of these devices.
CAUTION: Local regulations may prohibit “Lock on
Power Failure” if the door is used as a fire escape
route.
C. Door contact must be hardwired directly to the
PC4820. Wireless or addressable contacts may not be
used.
D. Install a T-Rex exit detector and door alarm (optional)
inside of the protected area. (See T-Rex Installation
Instructions for details on wiring and proper mounting
locations.)
2 Tamper protection
A tamper switch may be installed on the cabinet to protect
it from unauthorized entry. The normally closed tamper
switch is connected to the TAMP and GND (on right side
of the PC4820). If the tamper switch is not used, the
TAMP terminal must be terminated to any GND terminal
with a wire.
*UL Listed systems require tamper protection.
3 Connect all inputs, outputs, door locking devices and
card readers
Follow the instructions outlined in the sections below for
installing each type of device.
4 Power requirements
For UL/ULC installations, use a UL/CSA Listed Class 2
transformer mounted outside the cabinet. Connect the red
battery lead to the positive terminal and the black battery
lead to the negative terminal. The transformer must be a
Class 2 Fail-safe as per EN60742, permananently con-
nected. The transformer must meet the LVD and/or be cer-
tified for the intended market.
Connect the red battery lead to the positive terminal and
the black battery lead to the negative terminal.
NOTE: Do not apply power until all wiring is complete.
Both the AC and battery connections must be made in
order for the PC4820 to function properly. Connect the
battery before connecting the AC.
2.3 Inputs – POST, ARM and REX
The door inputs are capable of following any type of
supervision. Choose the end of line configuration (nor-
mally closed loops, single end of line or double end of
line) which you have selected for the rest of the security
system.
The POST, ARM and REX inputs are for Auto-arm post-
ponement, Arming buttons and Request to Exit devices,
respectively. These inputs will only be capable of nor-
mally closed loops or single end of line resistors. When
using double end of line supervision, these inputs must
only be wired for single end of line configuration. Please
see section 3.5 “Zone Assignment for Access Doors” for
information on door input zone programming.
POST Inputs
When enabled, this PC4820 input allows postponement of
Auto-arm of the PC4010/4020 for the partitions selected
in the Arm/Disarm mask. To postpone an Auto-arm, the
user must present their access card (during the Auto-arm
pre-alert) and activate the device connected to the POST
input. Typically the POST input will be a push button
device mounted next to the access card reader (107cm /
42" from the floor) which is assigned to the partition(s).
B
D
C
To PC4820 Access Con-
trol Module (see Access
Control Module
Wiring Diagram
for more details).
A

3
The PC4010/4020 will send an Auto-arm Abort reporting
code to the monitoring station if the reporting code is pro-
grammed. The Auto-arm will restart at the end of the Post-
pone Arm time (ref # [00020305]) unless the partition has
been manually rearmed. The auto-arm may be postponed as
many times as desired.
NOTE: To postpone an auto-arm, the user must be
assigned to the partition(s) being armed, and the user’s
access card must have the disarm attribute enabled. See
your PC4010/4020 Instruction Manual for information on
programming access codes and cards.
ARM Inputs
When enabled, this PC4820 input will allow designated
users to arm the selected partitions on the PC4010/4020. To
arm the partition, the user must first ensure that the partition
area to be armed is secure (close all protected doors and stop
movement in areas covered by motion detectors). The user
should present the access card and activate the device con-
nected to the ARM input. The exit delay will begin. Typi-
cally the ARM input will be connected to a push button
device and should be mounted next to the access card reader
(107cm /42" from the floor) which is assigned to the parti-
tion.
NOTE: To arm partitions, the user must be assigned to the
partition(s) being armed, and the user’s access card must
have the arm attribute enabled. See your PC4010/4020
Instruction Manual for information on programming
access codes and cards.
REX Inputs
A Request to Exit device can be used on the inside of the
secured area to provide a method of unlocking the door
without the need for an access card reader on the inside of
the door. When the REX device is tripped, the door will
unlock. This will also allow the door to be opened without
the door being “Forced open.” Request to exit devices can
be of many different types. Be sure to read the installation
sheets provided with each unit for proper installation for the
REX devices.
2.4 Outputs – LED, BUZ and OUT Terminals
LED Outputs
The LED outputs for Out Door 1 and Out Door 2 are used
for controlling the LED on the access card readers. This
allows the PC4820 to provide visual feedback when the
access card is presented to the reader. Connect the wire from
the reader indicated as LED to the LED terminal of the
selected output.
When using this output to switch an external device, the
negative terminal of the device must be connected to the
LED output terminal. The positive terminal of the external
device must be connected to the AUX+ terminal.
BUZ Outputs
The BUZ outputs for Out Door 1 and Out Door 2 are used
for controlling the buzzer of the access card readers. This
will allow the PC4820 to provide audible feedback to indi-
cate error conditions. Connect the wire indicated as buzzer
to the BUZ terminal of the selected output.
When using this output to switch an external device, the
negative terminal of the device must be connected to the
BUZ output terminal. The positive terminal of the external
device must be connected to the AUX+ terminal.
OUT Outputs
Reserved for future use.
2.5 Door Locking Devices – LK1 & LK2 Terminals
Connect door locks to LK1 and LK2. Each lock output can
provide up to 250mA at 12VDC. Always check local regula-
tions concerning the installation of magnetic locking
devices.
The locking device outputs are controlled according to the
installer-programmed parameters for allowing access to a
door, or unlocking the doors according to schedules. These
door locking device outputs can operate DC-powered lock-
ing devices such as electromechanical strikes and can be
configured to operate in fail-safe or fail-secure modes (nor-
mal or reverse action). The typical maximum DC for each
lock output is 250mA.
WARNING: According to local regulations, there may be
strict limitations to installing magnetic locks or other sim-
ilar locking devices on doors used for exit. Be sure to
check local regulations before installing any door-locking
device.
NOTE: The need to employ separate UL Listed panic hard-
ware shall be determined by the local authority having
jurisdiction.
2.6 Access Card Readers
Each PC4820 module can control two access card readers.
These can be installed on one door to control both entry and
exit, or on two separate doors to control access in one direc-
tion only. Using the proper cable, the readers may be located
up to 150 meters (500 feet) from the PC4820 module. The
access card readers should be mounted 107cm/42" from the
floor.
WARNING: Connecting the red wire lead (or power lead)
of a 5VDC reader to the 12VDC terminal may damage the
reader. See reader installation procedure for proper
power connection.
Using Two Readers to Control One Door
When using the Two Readers option, the PC4820 can use
both readers to control entry and exit from a single access
control point. Each reader can be programmed to have its
own access levels (allowing the ability to separately control
entry and exit permissions for each door on the system), and
schedules. See section 3.2 “Door Options” for programming
information.
NOTE: When using the Two Reader option, the Door 2
input must be terminated to any COM terminal.
Access Card / Keypad Readers
Access card readers with integrated keypads may be used
with the PC4820. In order to use this reader type, the user
must first present their access card. The LED on the reader
will flash twice every second to indicate to the user that the
reader is waiting for an access code to be entered. The user
will have 15 seconds to enter their access code. If the code is
entered successfully, the door will be unlocked. The access
code entered must be the correct code for the access card
used; otherwise access will not be granted, even if the code
entered is a valid code on the system. When access is denied
to the user due to a wrong/invalid code being entered, or
because time has expired waiting for the access code, the
LED on the reader will flash 3 times every second and the
buzzer will give an audible beep 3 times every second to indi-
cate that access was denied.

4
Reader LED Flash Rates
Most access card readers will have an LED output to pro-
vide visual feedback when the access card is presented to
the reader. The light will flash in different ways to indicate
the following conditions:
Buzzer Operation
Most access card readers will have a buzzer output to pro-
vide audible feedback. The buzzer output may be con-
nected to operate local warning devices for the following
conditions:
• The access-controlled door has been forced open. The
buzzer will activate and remain active until the door has
been closed.
• The access-controlled door has been left open too long.
The buzzer will activate and remain active until the door
has been closed. The buzzer will pulse on and off for the
last half of the programmed Door Open Time to indicate
that the Door Open Too Long event is about to occur.
*Tamper conenction not available on the MiniProx detector.
LED State Access Condition
Steady Red Door is locked
Steady Green Door is unlocked - Access
Granted
Slow flash (state changes
every half second
The partition that the
Arm/Disarm mask is
assigned to is armed
Medium Flash (state changes
3 times/second
Waiting for a Privileged
card to be presented
LED State Access Condition
Fast flash (state changes 4
times/second
Access denied/Time
expired waiting for a privi-
leged card.
PC4820 Connection Chart
Reader Connection
Function PC4820 Terminal
Polaris/ShadowProx/IoProx HID
Green Green Data 0 GRN
White White Data 1 WHT
Red Red +VDC or +12VDC +5V or +12V
Black Black Ground GND
Blue Yellow Buzzer Buzz
Brown Brown (Red LED) LED LED
Orange/Yellow
(Polaris only)
Terminals marked as Tamper
Common & Tamper Select* Tamper Switch
To PC4010/4020 zone or con-
nected in series with the
assigned door input on this
module (optional)
------- Blue Hold Not used
------- Orange Green LED Not used
------- Violet Return GND
Purple/Grey (POL-2KP only) ------- Independent Switch
Can be used for Arm or Post
inputs. See PC4820 Wiring Dia-
gram for instructions
PC4820 List of Supported Readers and Cards
Reader Type Reader Part Numbers Supply Voltage Card Part Numbers Format
Magnetic Stripe POL-1, POL-1W, POL-2, POL-2KP +5VDC POL-C1CN 00 Polaris
Bar Code BC-201
Proximity:
ShadowProx
SH-1, SH-2, SH-2KP +5VDC to 14VDC SH-C1, SK-K1, SH-CMG1, SH-
CMG2 01-KSFSH-4, SH-5 +12VDC
SH-6, SH-7 +24VDC TO 28VDC
HID
HID-MP5365 - MiniProx +12VDC HID-13666KSF, HID1336KSF,
HID-1386KSF, HID-1326KSF,
HID-1346KSF
02 - 26 Bit Wiegand
HID-PR5355, HID-PR5355KP -Prox-Pro
HID-MX5375 - MaxiProx
+10VDC to 15VDC
+14VDC to 28.5 VDC
IoProx P-100, 200, 300, 400 (all XSF/W26) +5VDC to 14VDC P10SHL, P20DYE
P30DMG, P40KEY
02-W26
07-XSF

5
PC4820 Access Control Module Reader Connections
Cabling Specifications
Polaris Readers (POL-1, POL-2, POL-2KP) ShadowProx Readers
NOTE: Only use the +5V power supply when
using Polaris Readers.
NOTE: Only use the +12V power supply when using
ShadowProx Readers.
HID Readers Connecting External Power Supplies
Component Maximum Wire Length Cable Description
Reader 5V 150m (500ft) 3 pair, #18AWG, stranded, overall shield
with extra drain conductor
Reader 12V 150m (500ft) 3 pair, #22AWG, stranded, overall shield
with extra drain conductor
Inputs (Door, REX, Post, Arm) 300m (1000ft) 2 pair, #22AWG, twisted pairs
AC Transformer 8m (25ft) 1 pair, #18AWG Ground
1 conductor, #18AWG, solid

6
Section 3: Programming the PC4820
Programming of the PC4820 is performed at the PC4010/
4020 control panel in Installer’s Programming mode.
Refer to Section 4 “How to Program” of the PC4010/4020
Installation Manual for instructions.
The following programming sections must be pro-
grammed for each PC4820 enrolled on the system. To
select a module, enter reference number [0011XX] where
“XX” refers to the PC4820 module number.
The control panel will transfer all necessary information
(access codes, scheduling, etc.) to each PC4820 module
whenever one of the following occurs:
1. the main panel is powered up
2. Installer’s Programming is exited (on PC4010/
PC4020 v3.1 and lower systems only)
3. a PC4820 loses and then restores communication
with the control panel
4. a PC4820 is hardware-defaulted
5. a PC4820 is enrolled
6. a downloading session has disconnected.
The data transfer can take up to 2.5 minutes per PC4820
module. When the transfer is completed, all keypads will
beep 16 times. Changes to PC4820 programming will not
take effect until the data transfer is complete.
3.1 Programming Reader Types
Ref # [0011XX00] where XX = PC4820 module #
The PC4820 is capable of supporting different types of
access card readers. The same type of reader must be used
on both doors of an access card module, but different mod-
ules may use different reader types. Enter the 2-digit code
for the reader type you are installing on the selected zone.
00 Polaris 1- Magnetic card reader. 7 Digits with clock
and data.
01 ShadowProx - Extended range proximity reader SH5,
SH6, SH7, SH-VR 32 Bits.
02 Io Prox, 26 bit standard Wiegand reader, HID proxim-
ity readers with non KSF cards.
The default access card reader type is 00 (Polaris 1).
07 InOut Kantech XSF format, 39 bit Wiegand (only on
v3.3 and higher).
NOTE: Use reader type 01 when using Kantech Secure
Format (KSF) devices.
3.2 Reader Options
Ref # [0011XX01] where XX = module #
This section contains the programming for the selected
PC4820. First, you must select which of the two doors to
program. Use the arrow (< >) keys to scroll to either Door
1 or Door 2 and press the [*] key to select. A series of tog-
gle options will be available for each door. Again, use the
arrow (< >) keys to scroll through each option and press
the [*] key to turn the selected option on or off.
The options available for each door are as follows:
•Lock Reversed: If enabled, power will be applied to
lock the door. The lock will remain closed when idle
and will deactivate when a valid access card is used to
open the door. The programming for this option is
dependent on the type of locking device being used.
Check the installation sheet provided with the locking
device to see what is required for power.
If disabled, power will be applied to unlock the door. This
option is for use with “Fail Secure” devices such as elec-
tronic door strikes (default = No).
•Unlock on REX: If enabled, tripping a Request To Exit
device will cause the door to unlock for the programmed
Door Unlock time (see Section 3.4 “Door Times”). If
disabled, tripping the Request To Exit device will not
cause the door to unlock (default = Yes).
•Flash When Arm: If enabled, the armed status of the
assigned partition(s) will be indicated by the light on the
reader assigned to the door. The LED will flash slowly
for the duration of the armed period.
NOTE: The partition(s) to which the door’s zone is
assigned must also be selected in the Arm/Disarm mask
for proper operation of this function.
If disabled, the LED on the access card reader will not
indicate the armed status (default = Yes).
•Relock On Arm: If enabled, a Request To Arm will relock
the door when the arm input is activated. If disabled, a
Request to Arm will not relock the door (default = No).
•Lock On Close: If enabled, a door unlocked by an access
card or by a REX device will lock once the zone is opened
and then closed. If disabled, a door unlocked by an access
card or by a REX device will relock once the zone is
opened (default = No).
•Code Required: If enabled, a valid access code must be
entered at an adjacent keypad in addition to the card swipe
in order for the door to unlock. If disabled, no code will be
required (default = No).
•LED Reversed: If enabled, the normal state of the LED
output on the PC4820 will be an open collector. If dis-
abled, the output’s normal state will be low (default = No).
•Two Readers: If enabled, both “doors” (card readers)
will be assigned to the same zone. This will allow the
PC4820 to control access both into and out of a secured
area at a single access point. The zone and partition
assignment of both doors on the PC4010/4020 must be
the same. (See section 3.5 “Zone Assignment for Access
Doors” and your PC4010/4020 Programming Manual
for information on zone and partition programming).
Any time an access card is presented at one reader to open
the door, the second reader will also allow access. This
will prevent a door forced open event (both lock outputs
will unlock).
Each door can still be programmed to have its own access
levels (allowing the ability to control both entry and exit
permissions for each door on the system), and schedules.
NOTE: This option can only be enabled for Door 1.
If disabled, doors 1 and 2 will have their own zone and
partition assignments (Default = No).
•Door Shunt*: If enabled, when the system gives a user
access, the system will bypass the door’s zone for the
length of the Door Unlock time. If the door is forced
open, the zone will go into alarm (or start an entry
delay). If the door is left open past the Door Open time,
the zone will go into alarm (or start an entry delay). If
the Door Shunt option is disabled, the system will not
bypass the zone that the door is assigned to after giving
a user access (Default = No).
•Unlock Safety*: If enabled, when a door is scheduled to
unlock at a specific time, it remains locked until a user
swipes a valid access card - the system then opens the
door. If disabled, the system will unlock the door at the
scheduled time (Default = No).

7
NOTE*: The Door Shunt and Unlock Safety features are
only available when the PC4820 is connected to a PC4020
v3.2 or higher.
•Unlock on Fire: If enabled, when a fire alarm occurs on
the same partition as the PC4820 door, the door will
unlock. The door will lock again when a successful fire
reset is performed.
NOTE: This feature is only available on PC4020 v3.5 or
higher.
3.3 Arming and Disarming with Access Cards
The PC4820 can be set up so that users may arm and dis-
arm, or postpone the autoarm of any active partition on the
system. To set up partitions to be armed and disarmed from
an access control module, the following must be pro-
grammed:
1. The user’s access card must be assigned to the appro-
priate partition(s); an access level must be assigned to
the access card; and the access card must have the
arm and or disarm attribute enabled (see section 3.8
“Programming Access Cards”).
2. The access door must be assigned a PC4010/4020
zone (see section 3.5 “Zone Assignment for Access
Doors”), and the zone must be assigned to the appro-
priate partitions (see below).
3. The Arm/Disarm mask must be programmed to
include the partition(s) that are to be armed/dis-
armed from that access card reader (see below).
4. The Postpone Arm, Arm Request and Disarm
Request schedules must be programmed with a date
schedule other than [00] (see section 3.6 “Access Door
Schedules”).
TIP: When using the arming/disarming options of the
PC4820, the use of Bell Squawk and a Partition Status
output will allow for clear indication of the armed status
of the partition(s). These options can be enabled/disabled
on each partition (see your PC4010/4020 Installation Man-
ual for more information on programming partitions).
NOTE: Do not turn on the One-time Use option for users
that also have access cards assigned.
Arm/Disarm Partition Mask
Ref # [0011XX01YY01] where XX = module #; YY = door #
In this section select the partition(s) which users will be able
to arm and/or disarm when they present the appropriate
access card at the reader for the access door.
NOTE: The zone assigned to the door must be assigned to
the same partitions selected in the Arm/Disarm Partition
Mask (Partition Programming, reference # [0100XX03],
where XX = partition #).
3.4 Door Times
Ref # [0011XX01YY02] where XX = module #; YY = door #
Door Unlock Time
The amount of time that the door will remain unlocked after
a valid access card has been presented is programmed in
this section. This is also the Request To Exit time period.
The default setting is 10 seconds. Valid entries are from
001-255 seconds.
Door Open Time
This section will program the amount of time an access door
can remain open before a Door Open Too Long event is
generated. After half of the Door Open Time has expired,
the reader buzzer will pulse on and off as a warning. At the
end of the Door Open Time, the buzzer will sound steady to
indicate that the door has been left open too long. The
default setting is 030 seconds. Valid entries are from 001-
255 seconds.
3.5 Zone Assignment for Access Doors
Ref # [0011XX01YY03] where XX = module #; YY = door #
Assign each “door” to a zone on the PC4010/4020. Any zone
from Zone 17 to 128 may be used (Zone 9 to 64 on the
PC4010).
You can use any zone supervision option provided by the
PC4010/4020 for PC4820 zones. The end of line resistors used
for the door inputs are 5600W for the alarm contact. If you will
be using DEOL resistors, the tamper contact is also 5600W.
The door’s zone must be programmed as a Standard Delay,
or an Auxiliary Delay zone (PC4010/4020 programming
reference number [0100XX03], where XX=partition num-
ber). See your PC4010/4020 v3.0 Installation Manual, sec-
tion 5 “Zone Programming”.
3.6 Access Door Schedules
A date schedule can be assigned to each of the following
access door features. A date schedule will include the start
and end times for each event, the days of the week the
schedule will be active for and any holiday groups the event
will observe.
Date Schedules 00 and 01
If date schedule 00 is programmed, the feature will be disabled
(schedule is never active). If date schedule 01 is programmed,
the feature will be always on (schedule is always active).
For more information regarding date schedule program-
ming, please refer to your PC4010/4020 Installation Man-
ual, “Date Schedules”.
There are 11 access door features which can be sched-
uled. They are as follows:
Postpone Arm Schedule
Ref # [0011XX01YY04] where XX = module #, YY = door #
This schedule will program at what times the auto arming
sequence can be postponed by a user presenting their access
card at the appropriate reader. Only the partitions to which
the door’s zone are assigned and that are selected in the
Arm/Disarm mask will be affected.
The user’s access card must also be assigned to the appro-
priate partitions and have the disarming attribute enabled
for the feature to work correctly. See your PC4010/4020
Instruction Manual for information on programming access
codes and cards.
The default date schedule is 01.
Arm Request Schedule
Ref # [0011XX01YY05] where XX = module #, YY = door #
This schedule will program when the selected partitions
may be armed by a user presenting their access card at the
appropriate reader. Only the partitions assigned to the door
zone and selected in the Arm/Disarm mask will be affected.
The user’s access card must also be assigned to the appro-
priate partitions and have the arming attribute enabled in
order for arming to occur. See your PC4010/4020 Instruc-
tion Manual for information on programming access codes
and cards.
The default date schedule is 01.
Door Unlock Schedule
Ref # [0011XX01YY06] where XX = module #, YY = door #
This schedule will determine when an access door will be
unlocked. When the door is unlocked, a user will not require
an access card to open the door. The door will remain
unlocked for the duration of the schedule. Opening the door
will not cause a door forced open event.
When the partition(s) to which the door zone is assigned are
armed, the door will automatically lock at the beginning of
the exit delay. If the Door Unlock schedule becomes active
while the partition(s) are armed, the door will not unlock.

8
However, if the partition is disarmed while the door unlock
schedule is active, the door will unlock, and will remain
unlocked until the scheduled end time.
NOTE: If the door is assigned to more than one parti-
tion, the door will only lock once the last partition to be
armed has begun its exit delay.
The default date schedule is 00 (disabled).
Request To Exit (REX) Schedule
Ref # [0011XX01YY07] where XX = module #, YY =
door #
This schedule controls the Unlock on REX option. When
the schedule is active, tripping a Request To Exit device
will cause the door to unlock for the programmed Door
Unlock time (see section 3.5 “Door Times”). If the sched-
ule is not active, a Request To Exit will not cause the door
to unlock.
The default date schedule is 01.
Second Card Schedule
Ref # [0011XX01YY08] where XX = module #, YY =
door #
This schedule will determine when users with the Wait For
Privilege option enabled will require a Privileged user to
grant them access to the area. If the Second Card Schedule
is active, the following will occur:
The user with the Wait For Privilege card presents their
card first. The LED on the card reader will flash slowly for
10 seconds. If during this time a Privileged card is used,
the door will be unlocked. Only privileged cards are capa-
ble of allowing access to the system. If a non-privileged
card is used, the door will not be unlocked and the event
will be logged to the buffer. This feature is used for moni-
toring the access of users on the system.
The default date schedule is 00 (disabled).
Disarm Request Schedule
Ref # [0011XX01YY09] where XX = module #, YY =
door #
This schedule will program the times when the selected
partitions may be disarmed by a user presenting their
access card at the appropriate reader. Only partitions
which have the door’s zone assigned to them, and which
are selected in the Arm/Disarm mask, will be affected.
To disarm the partition(s), the user must present their
access card and open the door. The partition(s) will be dis-
armed if the Disarm Request schedule is active. If the user
presenting their card is outside of the Disarm Request
schedule time window, the door will be unlocked but the
partition(s) will not be disarmed when the door is opened.
The user must then enter their access code at a keypad to
disarm the partition(s).
NOTE: To disarm a partition or enter a partition which is
armed, the user must be assigned to the partition, and
the user’s disarm attribute must be enabled in access
code and card programming. See your PC4010/4020
Instruction Manual for information on programming
access codes and cards.
The default date schedule is 00 (disabled).
Code Schedule
Ref # [0011XX01YY11] where XX = module #, YY =
door #
When this schedule is active, the door will not unlock until
the card is presented AND a valid access code is entered
on the keypad. When the schedule is inactive, the door
will unlock when an access card is presented.
If Schedule [00] is programmed into this section, the door
will be unlocked by an access card only when the parti-
tion(s) the door is assigned to are disarmed. When the par-
titions are armed, an access code will also be required.
NOTE: The Code Required option must be enabled in
order for this feature to work.
The default date schedule is 01.
Forced Open Schedule
Ref # [0011XX01YY12] where XX = module #, YY =
door #
When this schedule is active and a door is opened without
tripping a REX device, a Door Forced Open event will be
logged to the event buffer and transmitted to the central
station. When the schedule is inactive and a door is forced
open, the event will be logged, but not transmitted.
NOTE: In order for this option to work, the door must
be assigned a zone and that zone must be assigned to
one or more partitions.
The default date schedule is 00 (disabled).
Forced Open Bell Schedule
Ref # [0011XX01YY13] where XX = module #, YY =
door #
When this schedule is active and a door is opened without
tripping a REX device, the partition(s) the door is assigned
to will go into alarm. The alarm will be on until the bell
cut-off time expires, or until an access code is entered to
silence the alarm.
NOTE: In order for this option to work, the door must
be assigned a zone and that zone must be assigned to
one or more partitions.
The default date schedule is 00 (disabled).
Open Too Long Schedule
Ref # [0011XX01YY14] where XX = module #, YY =
door #
When the schedule is active and the assigned door is left
open past the Door Open time, an Open Too Long event
will be logged to the event buffer and transmitted. When
the schedule is inactive and the door is left open past the
Door Open time, the event will be logged but not transmit-
ted. The default Door Open time is set at 30 seconds but
can be changed (see Section 3.4 “Door Times”).
NOTE: In order for this option to work, the door must
be assigned a zone and that zone must be assigned to
one or more partitions.
The default date schedule is 00 (disabled).
Open Too Long Bell Schedule
Ref # [0011XX01YY15] where XX = module #, YY =
door #
When the schedule is active and the assigned door is left
open past the Door Open time, the partition(s) the door is
assigned to will go into alarm. The alarm will remain on
until the bell cut-off time expires, or until an access code is
entered to silence the alarm. The Door Open time is set at
30 seconds by default, but can be changed (see Section 3.4
“Door Times”).
NOTE: In order for this option to work, the door must
be assigned a zone and that zone must be assigned to
one or more partitions.
The default date schedule is 00 (disabled).

9
3.7 Access Level
Ref # [0011XX01YY10] where XX = module #, YY = door #
Access levels allow specific users to have access to areas of
the system at various times of the day. Each door can have
multiple access levels assigned to it. Each access level will
follow one date schedule.
There are 63 access levels for each door. To program access
levels, select an access level number (02-63) and then enter
the schedule number that the access level will follow.
Access cards programmed with access level 01 always have
access to all doors. Access levels 02 - 63 will be recognized
by the card reader during the windows provided by the
assigned date schedule.
Date Schedules 00 and 01
Access levels programmed with date schedule 01 will
always be recognized by the door. Access levels pro-
grammed with date schedule 00 will never be recognized by
the door. In order to disable an access level for a door,
assign the access level to Date Schedule 00.
By default all access levels are assigned to Date Schedule
00 (disabled).
3.8 Programming Access Cards
In order for an access card to function on the PC4820 the
card must first be programmed into the PC4010/4020. This
is done through user programming (enter [*][5][system
master code] or [supervisory code]). See your PC4010/4020
Instruction Manual for more information on programming
access codes and cards.

10
Section 4: Diagnostics
4.1 Hardware Reset
On occasion, it may be necessary to perform a reset of the
PC4820 to factory default programming. To perform a
hardware reset of the PC4820, the following steps must be
performed:
1. Power down the PC4010/4020 by removing both
AC and battery power from the control panel.
2. Power down the PC4820 modules by removing both
AC and battery power from the units.
3. Remove all connections from the following PC4820
terminals; OUT (for OUT DOOR 1), Door (for
INPUTS DOOR 1) and AUX+.
4. On the selected PC4820, connect a short from the
terminals marked as OUT (for OUT DOOR 1) and
Door (for INPUTS DOOR 1). Next connect a 5600
Ohm resistor from the Door input to the AUX+ ter-
minal.
5. Restore AC power to the PC4820 module(s).
6. Wait for 10 seconds; then remove AC power to the
PC4820 module(s).
7. Remove the connections made in Step 4.
8. Any terminal connections removed in Step 3 can
now be reconnected.
9. Restore AC and battery power to the PC4820 mod-
ule(s)
10. Restore AC and battery power to the PC4010/4020
control panel.
The PC4820 will now indicate to the PC4010/4020 that a
hardware default has been performed and the PC4010/
4020 will retransmit all programming information back to
the PC4820 modules. All keypads on the system will beep
quickly 16 times to indicate that the programmed informa-
tion has been sent to the PC4820.
Be sure to remove all connections involved in the hard-
ware default procedure when the hardware default has
been completed.
NOTE: When performing a hardware or software
default of the PC4010/4020 be sure to also perform a
hardware default on the PC4820. This will ensure that
all unwanted programming has been removed from the
module.
4.2 Diagnostics via VTAL LED (L1)
The VTAL LED (located on the right hand side of the cir-
cuit board) of the PC4820 is capable of providing diagnos-
tics information for various conditions that may appear on
the module.
• Steady flash (once per second) indicates normal opera-
tion.
• Fast flash indicates that communication to the PC4010/
4020 has been lost (Combus fault).
• On steady (1/2 second) indicates data is being received
from an access card reader.

11
Section 5: PC4820 Programming Worksheet
Record your PC4820 module programming information here. Make one copy of this sheet for each PC4820 you will install.
[0011] PC4820 Options (XX = module #; YY = door#)
[0011XX]PC4820 Module Number: |______|______|
[0011XX00] Reader Type Default: 00 |______|______|
[0011XX01YY]Select Door Number:Door 01 Door 02
[0011XX01YY00] Toggle Options: Default |_________| Default |_________|
Lock Reversed? N |_________| N|_________|
Unlock on REX? Y |_________| Y|_________|
NOTE: *The Door
Shunt and Unlock
Safety features are
only available when
the PC4820 is con-
nected to a PC4020
v3.2 or higher.
** Only available on
PC4020 v3.5 or higher
Flash when Arm? Y |_________| Y|_________|
Relock on Arm N |_________| N|_________|
Lock on Close? N |_________| N|_________|
Code Required? N |_________| N|_________|
LED Reversed N |_________| N|_________|
Two Readers? N |_________| N|_________|
Door Shunt?* N |_________| N|_________|
Unlock Safety?* N |_________| N|_________|
Unlock on Fire** N |_________| N|_________|
[0011XX01YY01] Arm / Disarm Mask
Partition: 12345678 12345678
NNNNNNNN NNNNNNNN
I_________I_________I_________I_________I_________I_________I_________I__________I I_________I_________I_________I_________I_________I_________I_________I__________I
[0011XX01YY02] Door Times: Default Default
Door Unlock Time 010 I_________I ________I_________I 010 I_________I ________I_________I
Door Open Time 030 I_________I ________I_________I 030 I_________I ________I_________I
[0011XX01YY03] Zone Assignment 000 I_________I ________I_________I 000 I_________I ________I_________I
[0011XX01YY04] Postpone Arm Schedule 01 I_________I________I 01 I_________I ________I
[0011XX01YY05] Arm Request Schedule 01 I_________I________I 01 I_________I ________I
[0011XX01YY06] Door Unlock Schedule 00 I_________I________I 00 I_________I ________I
[0011XX01YY07] REX Schedule 01 I_________I________I 01 I_________I ________I
[0011XX01YY08] Second Card Schedule 00 I_________I________I 00 I_________I ________I
[0011XX01YY09] Disarm Request Schedule 00 I_________I________I 00 I_________I ________I
[0011XX01YY10] Access Level (enter 02-63) Default [00] (ALL Levels)
Access
Level Schedule
Number Access
Level Schedule
Number Access
Level Schedule
Number Access
Level Schedule
Number Access
Level Schedule
Number Access
Level Schedule
Number
02 I_________I ________I 23 I_________I ________I 44 I_________I ________I 02 I_________I ________I 23 I_________I ________I 44 I_________I ________I
03 I_________I ________I 24 I_________I ________I 45 I_________I ________I 03 I_________I ________I 24 I_________I ________I 45 I_________I ________I
04 I_________I ________I 25 I_________I ________I 46 I_________I ________I 04 I_________I ________I 25 I_________I ________I 46 I_________I ________I
05 I_________I ________I 26 I_________I ________I 47 I_________I ________I 05 I_________I ________I 26 I_________I ________I 47 I_________I ________I
06 I_________I ________I 27 I_________I ________I 48 I_________I ________I 06 I_________I ________I 27 I_________I ________I 48 I_________I ________I
07 I_________I ________I 28 I_________I ________I 49 I_________I ________I 07 I_________I ________I 28 I_________I ________I 49 I_________I ________I
08 I_________I ________I 29 I_________I ________I 50 I_________I ________I 08 I_________I ________I 29 I_________I ________I 50 I_________I ________I
09 I_________I ________I 30 I_________I ________I 51 I_________I ________I 09 I_________I ________I 30 I_________I ________I 51 I_________I ________I
10 I_________I ________I 31 I_________I ________I 52 I_________I ________I 10 I_________I ________I 31 I_________I ________I 52 I_________I ________I
11 I_________I ________I 32 I_________I ________I 53 I_________I ________I 11 I_________I ________I 32 I_________I ________I 53 I_________I ________I
12 I_________I ________I 33 I_________I ________I 54 I_________I ________I 12 I_________I ________I 33 I_________I ________I 54 I_________I ________I
13 I_________I ________I 34 I_________I ________I 55 I_________I ________I 13 I_________I ________I 34 I_________I ________I 55 I_________I ________I
14 I_________I ________I 35 I_________I ________I 56 I_________I ________I 14 I_________I ________I 35 I_________I ________I 56 I_________I ________I
15 I_________I ________I 36 I_________I ________I 57 I_________I ________I 15 I_________I ________I 36 I_________I ________I 57 I_________I ________I
16 I_________I ________I 37 I_________I ________I 58 I_________I ________I 16 I_________I ________I 37 I_________I ________I 58 I_________I ________I
17 I_________I ________I 38 I_________I ________I 59 I_________I ________I 17 I_________I ________I 38 I_________I ________I 59 I_________I ________I
18 I_________I ________I 39 I_________I ________I 60 I_________I ________I 18 I_________I ________I 39 I_________I ________I 60 I_________I ________I
19 I_________I ________I 40 I_________I ________I 61 I_________I ________I 19 I_________I ________I 40 I_________I ________I 61 I_________I ________I
20 I_________I ________I 41 I_________I ________I 62 I_________I ________I 20 I_________I ________I 41 I_________I ________I 62 I_________I ________I
21 I_________I ________I 42 I_________I ________I 63 I_________I ________I 21 I_________I ________I 42 I_________I ________I 63 I_________I ________I
22 I_________I ________I 43 I_________I ________I 22 I_________I ________I 43 I_________I ________I
Default Default
[0011XX01YY11] Code Schedule 01 I_________I ________I 01 I_________I ________I
[0011XX01YY11] Forced Open Sched 00 I_________I ________I 00 I_________I ________I
[0011XX01YY11] Forced Open Bell 00 I_________I ________I 00 I_________I ________I
[0011XX01YY11] Open Too Long Schedule 00 I_________I ________I 00 I_________I ________I
[0011XX01YY11] Open Too Long Bell 00 I_________I ________I 00 I_________I ________I

FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved by Digital
Security Controls Ltd. could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not
installed and used properly, in strict accordance with the manufacturer’s
instructions, may cause interference to radio and television reception. It has
been type tested and found to comply with the limits for Class B device in
accordance with the specifications in Subpart “B” of Part 15 of FCC Rules,
which are designed to provide reasonable protection against such interfer-
ence in any residential installation. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does
cause interference to television or radio reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Re-orient the receiving antenna
• Relocate the alarm control with respect to the receiver
• Move the alarm control away from the receiver
• Connect the alarm control into a different outlet so that alarm control and
receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/tele-
vision technician for additional suggestions. The user may find the follow-
ing booklet prepared by the FCC helpful: “How to Identify and Resolve
Radio/Television Interference Problems”. This booklet is available from the
U.S. Government Printing Office, Washington, D.C. 20402, Stock # 004-
000-00345-4.
©2003 Digital Security Controls Ltd.
Toronto, Canada • www.dsc.com
Tech. Support: 1-800-387-3630 (Canada & U.S.) or 905-760-3036
Printed in Canada
29005940R003
Table of contents
Other Maxsys Control Unit manuals
Popular Control Unit manuals by other brands

SSS Siedle
SSS Siedle LEDM 600-0 Product information

Mercury Racing
Mercury Racing VesselView Installation, Calibration & Operation Manual

elobau
elobau 363 098 manual

Matrix Orbital
Matrix Orbital GLK24064-25 Technical manual

M-system
M-system R7ML-EA16 instruction manual

Luceo Technologies
Luceo Technologies PARALLEX Series user manual

Siemens
Siemens SIMATIC S7 3964 Connection manual

Genebre
Genebre 2108 Installation, operation and maintenance manual

Texas Instruments
Texas Instruments BOOSTXL-TPS652170 user guide

Graco
Graco Advanjet HV-2000b Setup and operation

CKD
CKD USB2 Series instruction manual

Vaporless
Vaporless ARM-4073 Installation & operation manual