UPG RAC14J18 THRU 60 Quick start guide

RAC SERIES
SPLIT-SYSTEM AIR CONDITIONERS
14.5 SEER – R-410A – 1 PHASE
1.5 THRU 5 NOMINAL TONS
MODELS: RAC14J18 THRU 60
Due to continuous product improvement, specifications are
subject to change without notice.
Visit us on the web at
www.upgnet.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY*
Extended 10-Years limited parts warranty.
Standard 10-Years limited compressor warranty.
Extended 10-Years limited parts warranty requires online
registration within 90 days of purchase for replacement or clos-
ing for new home construction.
*Does not apply to R-22 models, 3-Phase models, or internet sales.
See Limited Warranty certificate in User's Information Manual for details.
®
TECHNICAL
GUIDE
TECHNICAL
GUIDE
810751-UTG-A-0313
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The 14.5 SEER Series unit is the outdoor part of a versatile cli-
mate system. It is designed with a matching indoor coil compo-
nent from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with acces-
sories and documents to serve specific functions.
FEATURES
•Small Footprint - Extremely lightweight with a compact foot-
print, it is a perfect fit for any application.
•Quality Condenser Coils - The coil is constructed of alumi-
num microchannel tubing and enhanced aluminum fins for
reduced size and increased efficiency.
•Coil Protection - Coils are protected from damage by a slot-
ted, stamped steel coil guard and secondary polymer mesh.
•Optional Factory E-Coat - Available ElectroFin® coated coil
on select models.
•Protected Compressor - Compressors are protected inter-
nally by a high pressure relief valve and a temperature sen-
sor, and externally by the system high pressure switch. A
factory installed liquid line filter-drier further protects the com-
pressor against moisture and debris.
•Environmentally Friendly Refrigerant - The next genera-
tion refrigerant R-410A delivers environmentally friendly per-
formance with zero ozone depletion.
•Durable Finish - An automotive quality finish provides the
ultimate protection from harmful UV rays and rust-creep,
ensuring a long-lasting, high quality apprearance. A powder
paint top coat is applied over a baked on primer using a gal-
vanized, zinc coated steel base material.
•Lower Installed Cost - Installation time and costs are
reduced by easy power and control wiring connections. The
unit is factory charged for a 15-foot lineset. The small base
dimension means less space is required on the ground or
roof.
•Top Discharge - Warm air from the top mounted fan is blown
up, away from the structure and any landscaping. This allows
compact location on multi-unit applications.
•Quiet Operation - The compressor sound blanket and the
swept wing fan blade keep sound to a minimum. The upward
air flow carries the normal operating noise away from the liv-
ing area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the condenser coil
muffle the normal fan motor and compressor operating
sounds.
•Low Maintenance - Long life, permanently lubricated motor-
bearings need no annual servicing.
•Easy Service Access - Fully exposed refrigerant connec-
tions and a single panel covering the electrical controls make
for easy servicing of the unit.
•Secured Service Valves - Secured, re-usable service
valves are provided on both the liquid and vapor sweat con-
nections for ease of evacuating and charging.
•Agency Listed - Safety certified by CSA to UL 1995 / CSA
22.2. Performance certified to ANSI/AHRI Standard 210/240
in accordance with the Unitary Small Equipment certification
program.

810751-UTG-A-0313
2Johnson Controls Unitary Products
All dimensions are in inches and are subject to change without notice.
Overall height is from bottom of base pan to top of fan guard.
Overall length and width include screw heads.
Physical and Electrical Data
MODEL RAC14J18
4S21(E) RAC14J24
4S21(E) RAC14J30
4S21(E) RAC14J36
4S21(E) RAC14J42
4S21(E) RAC14J48
4S21(E) RAC14J60
4S21(E)
Unit Supply Voltage 208-230V, 1 60Hz
Normal Voltage Range 1187 to 252
Minimum Circuit Ampacity 12.0 16.8 18.4 19.1 23.9 26.3 32.7
Max. Overcurrent Device Amps 220 25 30 30 40 45 50
Min. Overcurrent Device Amps 315 20 20 20 25 30 35
Compressor
Amps
Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll
Rated Load 9.0 12.8 14.1 14.1 17.9 19.9 25.0
Locked Rotor 46 58 73 77 112 109 134
Crankcase Heater No No No No No No No
FactoryExternalDischargeMufflerNoNoNoNoNoNoNo
FactoryExternalCheckValve NoNoNoNoNoNoNo
HS Kit Required with TXV 4No No No No No No No
Fan Diameter Inches 1/8 1/8 1/8 1/4 1/4 1/4 1/4
Fan Motor
Rated HP 0.8 0.8 0.8 1.5 1.5 1.5 1.5
Rated Load Amps 22 22 22 22 24 24 24
Nominal RPM 1075 1075 1075 850 850 850 850
Nominal CFM 2750 2750 2800 3200 3600 3700 3750
Coil Face Area Sq. Ft. 13.1 13.1 17.4 17.4 20.0 21.4 24.0
Rows Deep 1 1 1 1 1 1 1
Fins / Inch 23 23 23 23 23 23 23
Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Vapor Line Set OD (Field Installed) 3/4 3/4 3/4 3/4 7/8 7/8 7/8
Unit Charge (Lbs. - Oz.) 53 - 10 3 - 2 3 - 7 3 - 10 4 - 4 5 - 1 5 - 4
Charge Per Foot, Oz. 0.62 0.62 0.62 0.62 0.67 0.67 0.67
Operating Weight Lbs. 125 128 130 145 172 208 231
Models with “E” on the end of the model number have an ElectroFin® coating on the outdoor coil.
1. Rated in accordance with AHRI Standard 110-2012, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract
the amount of refrigerant, using the difference in length multiplied by the per foot value.
B
C
A
Unit
Model
Dimensions
(Inches) Refrigerant Connection
Service Valve Size
A B C Liquid Vapor
18 28-1/4 29-1/2 29-1/2
3/8
3/4
24 28-1/4 29-1/2 29-1/2
30 36-1/4 29-1/2 29-1/2
36 36-1/4 29-1/2 29-1/2
42 34-1/4 34 34 7/848 36-1/4 34 34
60 40-1/4 34 34

810751-UTG-A-0313
Johnson Controls Unitary Products 3
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the outdoor unit, the smallest matched indoor unit, and 15 feet of interconnecting line tubing.
2. Verify the TXV and additional charge required for specific matched indoor unit in the system using the above table.
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For indoor matches requiring additional charge, the refrigerant needs to be weighed in for specific matched indoor unit and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + charge adder for matched indoor unit +
charge adder for line set.
System Charge for Various Matched Systems
Outdoor Unit RAC14J18
4S21(E) RAC14J24
4S21(E) RAC14J30
4S21(E) RAC14J36
4S21(E) RAC14J42
4S21(E) RAC14J48
4S21(E) RAC14J60
4S21(E)
Required TXV 1,24F1 4F1 4G1 4G1 4G1 4J1 4J1
Indoor Unit 3,4,5 Additional Charge, oz
RFCX18BE 0––––––
RFCX24BE 1516–––––
RFCX30BE 151613––––
RFCX36CE 24 23 19 15 – – –
RFCX42DE – 35 30 25 17 – –
RFCX48DE – – – 24 16 11 –
RFCX60DE – – – 29 22 15 13
RFCX18BP 0––––––
RFCX24BP –16–––––
RFCX30BP ––12––––
RFCX36BP – – 19 15 – – –
RFCX42CP – – – 25 17 – –
RFCX48DP – – – – 16 11 –
RFCX60DP – – – – 22 15 13
FC/MC/PC18 0––––––
FC/MC/PC32 151613––––
FC/MC/PC35 151613––––
FC/MC/PC37 23 22 19 15 – – –
FC/MC/PC43 23 22 19 15 8 – –
FC/MC/PC48 – 34302517 9 –
FC/MC/PC60 – – – 24 16 11 9
FC/MC62 – – – 29 21 15 13
FC64 – – – 39302621
HD24 14––––––
HD36 191916––––
HD48 – 45 40 34 26 – –
HD60 ––––2286
UC18 2––––––
UC48 – – – – 11 10 –
UC60 – – – 24 16 13 11
Some of the combinations shown in the above System Charge table require Advanced Main Air Circulating Fan indoor product. For approved coil
only matches, please see the “COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils” table.
FOOTNOTES:
1. For applications requiring a TXV use S1-1TVM*** series kit.
2. A TXV kit must be used with these indoor units to obtain system performance.
3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower Time Delay Kit S1-2FD06700224.
4. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
5. Refer to Cooling Performance Data tables for actual system performance for specified system matches.

810751-UTG-A-0313
4Johnson Controls Unitary Products
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER COIL
MODEL1
COOLING
MODEL WIDTH RATED
CFM NET MBH SEER EER
TOTAL SENS.
14.5 SEER AC WITH AIR HANDLERS
RAC14J184S21(E)
RFCX18BE 17.5 – 610 17.9 13.0 16.25 13.25
RFCX24BE 17.5 – 585 18.1 13.1 16.75 13.50
RFCX30BE 17.5 – 585 18.1 13.1 16.75 13.50
RFCX36CE 21.0 – 730 19.2 15.0 17.50 14.25
RFCX18BP 17.5 – 665 17.7 13.1 14.25 12.00
MX12B 17.5 FC/MC18B 585 17.9 12.8 16.50 13.50
MX12B 17.5 FC/MC35B 660 18.6 14.1 17.50 14.25
MX12B 17.5 FC/MC43B 620 18.5 13.3 17.50 14.00
RAC14J244S21(E)
RFCX24BE 17.5 – 795 25.2 18.7 16.25 13.50
RFCX30BE 17.5 – 795 25.2 18.7 16.25 13.50
RFCX36CE 21.0 – 855 26.2 19.7 17.00 14.25
RFCX42DE 24.5 – 820 26.4 19.5 17.25 14.50
RFCX24BP 17.5 – 740 24.8 17.7 15.00 12.75
MX12B 17.5 FC/MC35B 815 25.6 18.8 17.00 14.25
MX12B 17.5 FC/MC43B 735 25.6 18.4 16.75 14.00
RAC14J304S21(E)
RFCX30BE 17.5 – 985 29.6 21.1 15.50 13.00
RFCX36CE 21.0 – 1000 30.4 21.9 16.25 13.75
RFCX42DE 24.5 – 1000 30.8 22.3 16.75 14.00
RFCX30BP 17.5 – 1115 29.8 21.9 14.25 12.00
RFCX36BP 17.5 – 1060 30.0 21.7 14.50 12.25
MX12B 17.5 FC/MC35B 1085 30.4 22.1 16.00 13.25
MX12B 17.5 FC/MC43B 1095 30.8 22.7 16.25 13.50
MX16C 21.0 FC/MC35C 1035 30.2 21.7 16.50 13.75
MX16C 21.0 FC/MC43C 970 30.4 22.1 16.75 14.00
MX16C 21.0 FC/MC48C 995 30.8 22.3 17.00 14.25
RAC14J364S21(E)
RFCX36CE 21.0 – 1190 35.0 26.0 16.00 13.50
RFCX42DE 24.5 – 1180 35.2 26.4 16.50 13.75
RFCX48DE 24.5 – 1195 35.0 26.2 16.50 13.75
RFCX60DE 24.5 – 1190 35.4 26.6 16.75 14.00
RFCX36BP 17.5 – 1245 34.2 25.2 14.25 12.00
RFCX42CP 21.0 – 1230 34.8 26.2 14.75 12.50
MX12B 17.5 FC/MC43B 1220 35.0 26.2 15.50 13.00
MX12D 24.5 FC/MC48D 1225 35.4 26.8 16.25 13.50
MX12D 24.5 FC/MC60D 1275 35.2 26.8 16.25 13.50
MX12D 24.5 FC/MC62D 1270 35.8 27.4 16.75 14.00
MX12D 24.5 FC64D 1270 36.8 28.6 17.25 14.50
MX16C 21.0 FC/MC43C 1140 34.8 25.8 16.50 13.75
MX16C 21.0 FC/MC48C 1150 35.2 26.4 16.75 14.00
MX20D 24.5 FC/MC60D 1295 35.4 27.4 16.75 14.00
MX20D 24.5 FC/MC62D 1260 35.6 27.4 16.75 14.00
MX20D 24.5 FC64D 1260 36.8 28.6 17.25 14.50
RAC14J424S21(E)
RFCX42DE 24.5 – 1385 41.5 31.0 16.00 13.25
RFCX48DE 24.5 – 1385 40.5 30.6 16.00 13.00
RFCX60DE 24.5 – 1390 41.5 31.4 16.25 13.25
RFCX42CP 21.0 – 1485 41.0 31.2 14.75 12.00
RFCX48DP 24.5 – 1320 39.5 29.2 14.25 11.75
RFCX60DP 24.5 – 1350 40.5 30.2 14.75 12.25
MX16C 21.0 FC/MC43C 1365 41.0 30.6 16.00 13.25
MX16C 21.0 FC/MC48C 1390 41.5 31.2 16.25 13.25
MX16C 21.0 FC60C 1420 40.5 30.8 16.00 13.00
MX20D 24.5 FC/MC48D 1415 41.5 31.2 16.00 13.25
For notes see Page 5.

810751-UTG-A-0313
Johnson Controls Unitary Products 5
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
RAC14J424S21(E) MX20D 24.5 FC/MC60D 1470 41.0 31.6 16.25 13.25
MX20D 24.5 FC/MC62D 1470 41.5 32.2 16.25 13.50
MX20D 24.5 FC64D 1470 43.0 33.4 16.75 13.75
RAC14J484S21(E)
RFCX48DE 24.5 – 1600 46.0 32.6 15.25 12.50
RFCX60DE 24.5 – 1565 46.5 33.2 15.75 13.00
RFCX48DP 24.5 – 1610 45.5 32.0 14.25 11.75
RFCX60DP 24.5 – 1620 46.5 33.0 14.50 12.25
MX16C 21.0 FC/MC48C 1685 45.5 34.0 15.25 12.25
MX16C 21.0 FC60C 1420 45.5 31.0 15.75 13.00
MX20D 24.5 FC/MC48D 1525 45.5 33.4 15.50 12.75
MX20D 24.5 FC/MC60D 1470 45.5 31.2 16.00 13.00
MX20D 24.5 FC/MC62D 1605 47.0 34.0 16.00 13.25
MX20D 24.5 FC64D 1605 47.5 34.4 16.50 13.50
RAC14J604S21(E)
RFCX60DE 24.5 – 1835 56.5 39.6 14.50 12.50
RFCX60DP 24.5 – 1870 56.0 39.1 13.75 11.75
MX20D 24.5 FC/MC60D 1780 55.5 37.4 14.50 12.50
MX20D 24.5 FC/MC62D 1795 57.0 39.6 15.00 12.75
MX20D 24.5 FC64D 1795 57.5 41.0 15.25 13.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in
watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER COIL
MODEL1
COOLING
MODEL WIDTH RATED
CFM NET MBH SEER EER
TOTAL SENS.
14.5 SEER AC WITH AIR HANDLERS
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT MODEL COIL CFM RANGE
(MIN.-MAX.)
COOLING
MODEL WIDTH RATED
CFM NET MBH SEER 1EER
TOTAL SENS.
14.5 SEER AC COIL ONLY RATINGS
RAC14J184S21(E)
FC/MC/PC18 14.5,17.5 450-750 600 17.3 12.4 14.00 11.50
FC/MC/PC32 14.5 450-750 600 17.8 12.8 14.50 12.00
FC/MC/PC35 17.5,21.0 450-750 600 17.8 12.8 14.50 12.00
FC/MC/PC37 14.5 450-750 600 18.0 12.9 14.75 12.00
FC/MC/PC43 17.5,21.0 450-750 600 18.0 12.9 14.75 12.00
HD24 – 450-750 600 17.9 12.8 14.50 12.00
HD36 – 450-750 600 17.3 11.9 14.00 11.50
UC18 14.5,17.5 450-750 600 17.4 12.5 14.00 11.75
RAC14J244S21(E)
FC/MC/PC32 14.5 500-900 700 24.4 17.2 14.50 12.30
FC/MC/PC35 17.5,21.0 500-900 800 25.0 17.6 14.50 12.35
FC/MC/PC37 14.5 500-900 800 25.4 17.9 14.50 12.35
FC/MC/PC43 17.5,21.0 500-900 800 25.2 18.0 14.70 12.50
FC/MC/PC48 21.0,24.5 500-900 800 25.6 18.3 14.80 12.65
HD36 – 500-900 800 24.8 17.0 14.00 12.00
HD48 – 500-900 800 25.6 17.9 14.50 12.35
RAC14J304S21(E)
FC/MC/PC32 14.5 800-1200 1000 29.0 21.0 14.00 12.00
FC/MC/PC35 17.5,21.0 800-1200 1000 29.0 21.0 14.00 12.00
FC/MC/PC37 14.5 800-1200 1000 29.6 21.6 14.50 12.35
FC/MC/PC43 17.5,21.0 800-1200 1000 29.6 21.8 14.50 12.30
FC/MC/PC48 21.0,24.5 800-1200 1000 30.0 21.8 14.50 12.35
HD36 – 800-1200 1000 28.8 20.2 14.00 12.00
HD48 – 800-1200 1000 29.8 21.4 14.50 12.35
For notes see Page 6.
Table of contents
Other UPG Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual