Vaillant auroTHERM VFK 145 H/V User manual

auroTHERM
VFK 125
VFK 135 D
VFK 140 D
VFK 145 H/V
VFK 150 H/V
ES, GB, NL, PT
In roof

For the expert technician
Installation manual
auroTHERM
VFK 145 H/V
VFK 150 H/V
In-roof mounting
GB

1 Notes on the documentation
The instructions below are intended to help you
throughout the entire documentation.
1.1 Other applicable documents
All installation instructions of flat collectors and compo-
nents of the installation must be observed when install-
ing the solar system. These instructions are included
with the individual components of the system and the
additional components.
We accept no liability for a damage caused by failure
to observe these instructions.
1.2 Attachment and storage of documents
Please pass on this installation manual and all other ap-
plicable documents and auxiliary equipment to the plant
operator, whose responsibility it is to ensure the manu-
als and auxiliary equipment are available whenever re-
quired.
1.3 Symbols used
Please observe the safety instructions in this installation
manual for the installation of the collector!
dDanger!
Immediate risk of serious injury or death!
eDanger!
Risk of death from electric shock!
HDanger!
Danger of burning and scalding!
aCaution!
Potentially dangerous situations for the prod-
uct and the environment!
hNote
Useful information and instructions.
• Symbol indicating the required action
1.4 Applicability of the manual
These installation manual applies exclusively to flat col-
lectors with the following article numbers:
Collector type Article number
VFK 145 H 0010004457
VFK 145 V 0010004455
VFK 150 H 0010006285
VFK 150 V 0010006283
Table 1.1 Collector types and article numbers
For the flat collector article number please see the iden-
tification plate on the upper collector edge.
Contents
1 Notes on the documentation.............................. 2
1.1 Other applicable documents ...................................... 2
1.2 Attachment and storage of documents .................. 2
1.3 Symbols used ................................................................. 2
1.4 Applicability of the manual......................................... 2
2 Intended use ..........................................................3
2.1 Combination with other components ...................... 3
2.2 Operational conditions ................................................ 3
2.3 CE mark ........................................................................... 3
3 Safety instructions ............................................. 4
3.1 Technical Guidance.......................................................4
3.2 Related documents.......................................................4
3.3 Regulations for the prevention of accidents .........4
3.4 Lightning protection.....................................................5
3.5 Frost protection.............................................................5
4 Installation............................................................ 5
4.1 Before installation ........................................................5
4.2 Scope of delivery ..........................................................6
4.3 Collector field packaging........................................... 10
4.4 Interconnection diagram.............................................11
4.5 Installation dimensions...............................................12
4.6 Hydraulic connection preparation...........................14
4.7 Installation .....................................................................14
4.8 Concluding work..........................................................25
5 Disposal...............................................................25
6 Vaillant Customer Service and warranty.......25
6.1 Vaillant warranty.........................................................25
6.2 Vaillant Service............................................................25
7 Technical data .................................................... 26
Installation manual auroTHERM 0020057148_032
Contents
1 Notes on the documentation

Vaillant auroTHERM flat collectors are available in dif-
ferent versions: one for the horizontal position, one for
the vertical position.
Besides, collectors in the collector field can be arranged
side by side and on top of each other.
Generally, the installation steps and the instructions
described in this manual are valid for both collector
positions and field arrangements.
Any different installation steps are clearly pointed out:
wWith horizontal collector position
sWith vertical collector position
nWith fields arranged side by side
uWith fields arranged on top of each other
2 Intended use
The Vaillant auroTHERM flat collectors are built and de-
signed according to accepted safety rules and regula-
tions.
Nevertheless, improper use may cause danger to life
and limb of the user or third parties and could impair
the operation of the unit and other objects.
The unit is not intended for use by persons (including
children) with reduced physical, sensory or mental capa-
bilities, or lack of experience and/or knowledge, unless
they have been given supervision or instruction con-
cerning use of the unit by a person responsible for their
safety.
Children must be watched to ensure that they do not
play with the unit.
Vaillant auroTHERM flat collectors are used for heating
support and for solar hot water generation.
Any other use or use exceeding the above-mentioned
applications shall be considered as improper use. The
manufacturer/supplier shall not be responsible for any
damages resulting from such improper use. The user
alone bears the risk.
Use includes observance of the operating and installa-
tion manuals and all other applicable documents, as well
as adherence to the maintenance and inspection condi-
tions.
aCaution!
Any improper use is forbidden!
2.1 Combination with other components
Vaillant flat collectors should be combined only with
Vaillant components (fixing, connections) and system
components.
The use of other components or system components
shall be considered as improper use. We accept no liabil-
ity.
2.2 Operational conditions
aCaution!
Collector damage!
Flat collectors are suitable for a maximum
snow load of 5.0 kN/m2and a maximum wind
load of 1.6 kN/m2.
Caution!
The roof may collapse!
Mount the flat collectors only on roofs with a
sufficient load-carrying capacity.
If necessary, call a technician.
Caution!
Lack of tightness!
For in-roof mounting, the roof must have a
pitch of ≥22°.
With roof angles <22° rainwater can collect on
the cover plates and leaks can occur.
With roof angles of 15°-22° use the Vaillant
cover kit 0020059599 or 0020059879.
2.3 CE mark
The CE mark certifies that the appliances, according to
the models available, satisfy the basic requirements of
the following directives:
— Directive 97/23/EWG of the European Parliament and
Council for approximation of the laws of the member
states regarding pressure equipment
auroTHERM flat collectors are built accord-
ing to the state of the art and recognised
safety rules and regulations.
Conformity with the applicable standards
has been demonstrated.
auroTHERM flat collectors have been suc-
cessfully tested according to the rules and
requirements for the Solar Keymark.
3Installation manual auroTHERM 0020057148_03
Notes on the documentation 1
Intended use 2
GB

3 Safety instructions
The following safety instructions, technical rules and ac-
cident prevention regulations must be observed when
installing the flat collectors.
dDanger!
Risk of death from falls and falling objects!
Observe the national regulations for working at
heights.
HDanger!
Danger of burning and scalding!
In case of solar irradiation inside the units, col-
lectors can reach 200 °C. Remove the sun pro-
tection film installed at the factory only after
the solar energy system has been started up.
HDanger!
Danger of burning and scalding!
In case of solar irradiation inside the units, col-
lectors can reach 200 °C.
Do not perform maintenance work under direct
sunlight.
aCaution!
Collector damage!
In order to install flat collectors according to
the installation manual, a qualified engineer is
required. The installation should be performed
only by qualified engineers.
3.1 Technical Guidance
The system must be installed in accordance with all rel-
evant and applicable national regulations, and must be
installed to suit site conditions.
Observe all national regulations, including:
— Working at Heights Regulations 2005
— Health and Safety at Work Act 1974
— Electricity at Work Regulations 1989
— IEE Wiring Regulations BS 7671
— Lightning protection requirements
— Equipotential bonding of electrical installations.
3.2 Related documents
The installation of the solar system must be in accord-
ance with the relevant requirements of Health and Safe-
ty Document No. 635 (The Electricity at Work Regula-
tions 1989), BS7671 (IEE Wiring Regulations) and the
Water Supply (Water Fitting) Regulations 1999, or The
Water Bylaws 2000 (Scotland). It should also be in ac-
cordance with the relevant requirements of the Local
Authority, Building Regulations, The Building Regula-
tions (Scotland), The Building Regulations (Northern Ire-
land) and the relevant recommendations of the follow-
ing British Standards:
— BS EN 806: Specification for installations inside build-
ings conveying water for human consumption
— BS 6700: Services supplying water for domestic use
within buildings and their curtilages.
— BS. 5449 Forced circulation hot water central heating
systems for domestic premises.
Note: only up to 45 kW.
— BS. 6880 Low temperature hot water heating systems
of output greater than 45 kW.
Part 1 Fundamental and design considerations.
Part 2 Selection of equipment.
Part 3 Installation, commissioning and maintenance.
— BS 6114: Expansion vessels using an internal dia-
phragm for unvented hot water supply systems
— BS 4814 Specification for: Expansion vessels using an
internal diaphragm, for sealed hot water heating sys-
tems.
Unvented hot water systems must comply with building
regulation G section 3.
3.3 Regulations for the prevention of accidents
When carrying out works such as solar installation work
it is necessary to do so in a safe and workman like man-
ner, taking due care of any aspects of the works that
could result in injuries to person in or about the building
as well as workers, passers by and the general public at
large. To that end these works must conform, but not be
limited to, the current regulations in force such as the
following
— Health and Safety at Work act 1974
— Work at Height Regulations 2005.
— Electricity at Work Regulations 1989
— All necessary Building Regulations.
Work should be preceded by a risk assessment covering
all aspects of health and safety risks, or training re-
quirements that can reasonably be foreseen to be asso-
ciated with the work. All scaffolding in the UK, other
than prefabricated (zip-up) scaffold towers, must be de-
signed and constructed by a vetted contractor, and
have suitable kick boards, hand rails and where appro-
priate netting. Areas around the scaffolding should be
zoned off and marked with suitable warning signs to a
suitable distance to protect persons from falling objects.
Workers should have available and use personal protec-
tive equipment as necessary. This would include equip-
ment such as fall protection systems, safety gloves,
goggles, dust masks as well as any specialised equip-
ment that may be in use such as lifting and handling
equipment.
The completed works shall comply with all necessary
BS EN Standards and Codes of practice as well as Build-
ing control or planning requirements and be confirmed
where necessary by notification to building control or
the appropriate competence based notification body.
Installation manual auroTHERM 0020057148_034
3 Safety instructions

3.4 Lightning protection
aCaution!
Damage from lightning!
If the installation height is more than 20 m or
if the collectors are projected above the roof
ridge, electro-conductive components must be
connected to a lightning protection device!
3.5 Frost protection
aCaution!
Damage due to frost!
Under no circumstances should water on its
own be in the collector if there is a danger of
frost!
After pressurisation and flushing, the collectors
may contain water residues.
Immediately fill the solar system with solar
fluid. Check the fluid concentration with a frost
protection tester. Water remaining in the solar
circuit may dilute the fluid.
4 Installation
4.1 Before installation
Please note the following instructions before and during
installation:
dDanger!
Risk of death from falls and falling objects!
Observe the national regulations for working at
heights.
Wear the Vaillant safety belt
(article number 302066).
dDanger!
Risk of death from falls!
During installation never step on the cover
plate. It might break due to an excessive load.
HDanger!
Danger of burning and scalding!
In case of solar irradiation inside the units, col-
lectors can reach 200 °C. Remove the sun pro-
tection film installed at the factory only after
the solar energy system has been started up.
aCaution!
Collectors may be damaged by incorrect stor-
age!
Always store the collectors in a dry place and
protected from the elements.
Caution!
Roof construction damage due to missing rear
roof ventilation!
There must be roof back ventilation in accord-
ance with regulations.
Caution!
System error function due to air bubbles!
To fill the system, use the fill trolley
(article number 0020042548) to avoid air
bubbles.
Use the manual air vent installed on the collec-
tor field.
Alternatively, install the Vaillant solar
automatic air vent (article number 302019) in
the highest point of the system or the auto-
matic de-aerator (article number 302418) in
the solar circuit. Observe the relevant installa-
tion and operating manual.
5Installation manual auroTHERM 0020057148_03
Safety instructions 3
Installation 4
GB

4.2 Scope of delivery
• Check the mounting kit for completeness based on the
illustrations and bills of materials.
9
12
20
22
23
17
27
29
19
24
11
21
13 10
18
26
15
16
28
25
14
Fig. 4.1 Vertical collector mounting kit
hNote
The vertical collectors are arranged side by
side in the collector field.
1
2
4
56
3
78
Installation manual auroTHERM 0020057148_036
4 Installation

Roof angle 15-22° Roof angle 22-75°
Basic kit Basic kit Extension kit
Number of
collectors
23121
Pos. Description Number Kit
no.
Number Kit
no.
Number Kit
no.
Number Kit
no.
Number Kit
no.
1 Clamp 4
0020065267
4
0020065267
4
0020065267
4
0020065267
-
2 Upper supply (with probe) 1 1 1 1 -
3 Return (inlet) 1 1 1 1 -
4 Lower plug 1 1 1 1 -
5 Upper plug (with ventilation) 1 1 1 1 -
6 Pipe coupling 2
0020055181
4
2x
0020055181
2
0020055181
2
0020055181
2
0020055181
7 Clamp 4 8 4 4 4
8 Collector 2 3 1 2 1
9 Tile bar 2
0020059599
3
0020059879
1
0020060175
2
0020055196
10 Ridge plate - - 1 - -
0020055198
11 Upper ridge plate coupling - - - 1 1
12 Right ridge plate - - - 1 -
13 Left ridge plate - - - 1 -
14 Ridge plate extension - - - - 1
15 Ridge plate 2 collectors roof angle
15-22° 1----
16 Ridge plate 3 collectors roof angle
15-22° -1---
17 Right side section 1 1 1 1 -
18 Left side section 1 1 1 1 -
19 Profile end 3 4 2 3 1
20 Central front section - 1 1 - 1
21 Right front section 1 1 - 1 -
22 Left front section 1 1 - 1 -
23 Intermediate plate 1 2 - 1 1
24 Support board - - 1 1 1
25 Lower ridge plate coupling - - 2 3 1
26 Roof batten 3 3 2 3 3
27 Inner clamp 9 12 6 9 3
28 Bolt kits (no. 1-5)
(TX 25)
Bolts no. 1 28 40 16 28 12
Bolts no. 2 17 19 15 17 2
Bolts no. 3 10 13 7 10 3
Bolts no. 4 10 14 6 10 4
Bolts no. 5 3 5 - 3 2
29 External clamp 10 10 10 10 -
Table 4.1 Vertical collector mounting kit side by side
7Installation manual auroTHERM 0020057148_03
Installation 4
GB

hNote
The horizontal collectors can be arranged in the
collector field both side by side and on top of
each other.
11
29
25
20
28
17
26
24
13
10
23
14
19
22
9
21
31
2712
30
18
16
15
Fig. 4.2 Horizontal collector mounting kit
7
4
6
3
2
5 1
8
Installation manual auroTHERM 0020057148_038
4 Installation

Basic kit
side by side
Basic kit
side by side
Extension side by
side
Extension on top of
each other
Collectors 1 2 1 2
Pos. Description Number Kit no. Number Kit no. Number Kit no. Number Kit no.
1 Clamp 4
0020065267
4
0020065267
--
2 Upper supply (with probe) 1 1 - -
3 Return (inlet) 1 1 - -
4 Lower plug 1 1 - -
5 Upper plug (with
ventilation) 11--
6Pipe coupling - 2
0020055181
2
0020055181
-
7Clamp - 4 4 -
8 Collector 1212
9 Central ridge plate -
0020059906
2
0020055197
2
0020055199
-
0020059911
10 Upper ridge plate coupling 1 3 2 -
11 Right ridge plate 1 1 - -
12 Left ridge plate 1 1 - -
13 Right side section 1 1 - -
14 Left side section 1 1 - -
15 Right side section (lower) - - - 1
16 Left side section (lower) - - - 1
17 Profile end 2 3 1 -
18 Central front section - 1 1 -
19 Right front section 1 1 - -
20 Left front section 1 1 - -
21 Intermediate plate - 1 1 -
22 Support board 1 2 1 -
23 Lower ridge plate coupling 3 5 2 -
24 Horizontal intermediate
plate ---1
25 Retainer strip - - - 2
26 Spacer - - - 2
27 Tile bar 1 2 1 -
28 Roof batten 4848
29 Inner clamp 6 9 6 12
30 Bolt kit (no. 1-5)
(TX 25)
Bolt no. 1 22 44 22 7
Bolt no. 2 15 20 5 7
Bolt no. 3 7 10 3 6
Bolt no. 4 10 18 8 8
Bolt no. 5 3 7 4 -
31 External clamp 8 8 - 8
Table 4.2 Horizontal collector mounting kit
9Installation manual auroTHERM 0020057148_03
Installation 4
GB

4.3 Collector field packaging
Define the required components based on Tab. 4.3.
Number of collectors: 1 2 3 4 5 6 7 8 9 10
Field arrangement side by side
22-75° roof angle
Horizontal collector position
In-roof covering
1st kit horizontal
Article number 0020059906
1---------
In-roof covering
2nd kit horizontal
Article number 0020055197
-111111111
In-roof covering
Extension horizontal
Article number 0020055199
--12345678
Hyd. connection kit
Article number 0020065267 1
Hyd. connection kit
Article number 0020055181 -123456789
Vertical collector position
In-roof covering
1st kit vertical
Article number 0020060175
1---------
In-roof covering
2nd kit vertical
Article number 0020055196
-111111111
In-roof covering
Extension vertical
Article number 0020055198
--12345678
Hyd. connection kit
Article number 0020065267 1
Hyd. connection kit
Article number 0020055181 -123456789
15-22° roof angle
Vertical collector position
In-roof covering
2nd kit vertical
Article number 0020059599
-1--------
In-roof covering
3rd kit vertical
Article number 0020059879
--1-------
Hyd. connection kit
Article number 0020065267 -11-------
Hyd. connection kit
Article number 0020055181 -12-------
Field arrangement on top of
each other
Horizontal collector position
In-roof covering
1st kit horizontal
Article number 0020059906
11--------
In-roof covering
Extension horizontal
Article number 0020059911
-1--------
Hyd. connection kit
Article number 0020065267 11--------
Hyd. connection kit
Article number 0020059894 -1--------
Table 4.3 Collector field package
Installation manual auroTHERM 0020057148_0310
4 Installation

4.4 Interconnection diagram
hNote
Observe the planning information when dimen-
sioning the field volume flow.
aCaution!
Lack of tightness!
For in-roof mounting, the roof must have a
pitch of ≥22°. At roof pitches < 22° rainwater
can collect on the cover plates and leaks can
occur.
With roof angles of 15°-22° use the Vaillant
cover kit 0020059599 or 0020059879.
nField arrangement side by side
hNote
If you connect 1 to 5 collectors one after anoth-
er, the hydraulic connections can be laid one
below the other on one side.
145...
Fig. 4.3 Field arrangement side by side for 1 - 5 collectors
hNote
If you connect 6 or more collectors one after
another, the hydraulic connections must be ar-
ranged diagonally, to force a complete flow.
112
11
2...
Fig. 4.4 Field arrangement side by side for 6 - 12 collectors
uField arrangement on top of each other
max. 2
Fig. 4.5 Field arrangement on top of each other
11Installation manual auroTHERM 0020057148_03
Installation 4
GB

4.5 Installation dimensions
D
A
B
E
C
G
F
Fig. 4.7 Dimensions for the installation field and the position of
the battens (The reference line in each case is the roof
tile border)
ABCDEF G
sVertical collector position
nField arrangement side by side 2725 see Tab.
4.5 2291 2191 n. a.
309
(min. 280) 150
wHorizontal collector position
nField arrangement side by side 1925 see Tab.
4.5 1487 1387 n. a.
uField arrangement on top of
each other
see Tab.
4.5 2597 2796 2586 1146
Table 4.4 Dimensions of the installation field in mm
Number of collectors 1 2 3 4 5 6
Field
arrangement
side by side
Vertical
Exposed surface width (B) 2073 3336 4599 5862 7125 8388
Covered surface width
(Roofing border to the metal protection from left to right) 1457 2720 3983 5246 6509 7772
Horizontal
Exposed surface width (B) 2873 4936 6999 9062 11125 13188
Covered surface width
(Roofing border to the metal protection from left to right) 2337 4400 6463 8526 10589 12498
Field
arrangement
on top of
each other
Horizontal
Exposed surface height (A) 1925 3230
n. a.
Covered surface width
(Roofing border to the metal protection from left to right) 2337 2337
Table 4.5 Dimensions of the covered/exposed surface
Installation manual auroTHERM 0020057148_0312
4 Installation

4.6 Hydraulic connection preparation
Fig. 4.8 Feeding the pipe through the sarking membrane
If there is a sarking membrane, proceed as follows:
• Cut the sarking membrane vee-shaped.
• Fold the upper, larger tab on the roof batten above,
and the lower, smaller tab on the roof batten below.
• Fix the sarking membrane tight to the roof batten.
This ensure that the dampness flows away to the side.
• With the roofs activated, cut out a hole with the com-
pass saw.
• Work the roofing felt as described for the sarking
membrane.
4.7 Installation
• For the installation of flat collectors, prepare the fol-
lowing tools and materials.
Fig. 4.9 Installation tools: water level, cordless screwdriver,
Torx bit (TX25, supplied), drill 4.5 mm, hammer, meas-
uring tape/folding rule, rubber mallet, trimming knife,
waterproof silicone and hand riveter (supplied)
Vaillant flat collectors are available in different versions:
one for the horizontal position, one for the vertical posi-
tion.
Besides, they can be arranged in the collector field side
by side and on top of each other.
Generally, the installation steps and the instructions
described in this manual are valid for both collector
positions and field arrangements.
Any different installation steps are clearly pointed out:
wWith horizontal collector position
sWith vertical collector position
nWith fields arranged side by side
uWith fields arranged on top of each other
13Installation manual auroTHERM 0020057148_03
Installation 4
GB

Fig. 4.10 Defining the installation field
• Based on the dimensions (see Fig. 4.7),
define the installation field on the roof.
• Remove the tiles.
• Mount additional roof battens in accord-
ance with Fig. 4.7.
aCaution!
If you use the existing roof battens
for fixing, check the roof battens for
sufficient load carrying capacity!
1
A
B
Fig. 4.11 Mounting the left lower frame
• Hook the left front section (A) to the roof
batten.
• When mounting a single vertical collector,
hook the front section (B) to the roof bat-
ten.
• With 6 sealing bolts (bolts no. 1) (1) screw
the front section to the roof batten using
the supplied Torx bit.
aCaution!
Remove the protection film from the
flexible protection adhesive surface
only after the installation of the en-
tire collector field!
1
2
Fig. 4.12 Mounting the remaining lower frames
• Slide the next front section up to the mark
(1) on the first front section and with the
supplied Torx bit screw it to the roof bat-
ten with the 6 supplied sealing bolts (bolts
no. 1).
• Gradually fix the remaining frame compo-
nents from left to right based on the
number of collectors.
• Conclude the field with the right front sec-
tion.
1
Fig. 4.13 Inserting the right collector
• Hook the right collector to the straps on
the front section.
• Align the collector laterally with the mark
(1) on the front section.
Installation manual auroTHERM 0020057148_0314
4 Installation

1
2
Fig. 4.14 Screwing the flat collectors
• With the supplied Torx bit screw the collec-
tor laterally to the roof battens with 4 sup-
plied clamps and bolts no. 3.
The folded side (1) of the clamp must point
away from the collector.
• Take care that the chamfered side (2) of
the clamp grips the edge of the collector.
1
Fig. 4.15 Screwing the spacers
uWith fields arranged on top of each
other
• With the supplied Torx bit screw the spac-
ers to the roof battens above the collector
with the supplied bolts no. 3.
1
2
Fig. 4.16 Preparing the collector
uWith fields arranged on top of each
other
Upper collector preparation
• Insert the retainer strips into the lower slot
of the collector frame (1).
• Slide the retainer strips under the upper
collector edge, until they lock (2).
Fig. 4.17 Placing the collector
uWith fields arranged on top of each
other
• Place the next collector so that it flashes
with the spacers.
15Installation manual auroTHERM 0020057148_03
Installation 4
GB

a
1
2
Fig. 4.18 Hydraulic connection
uWith fields arranged on top of each
other
• Connect the collectors with the O-ring pipe
coupling.
• Fix the connection with the clamps.
aCaution!
Danger of damage to the collector as
a result of incorrect assembly!
Make sure that the clamps (1) slide
into the slot on the O-Ring pipe cou-
pler (2).
1
2
3
4
Fig. 4.19 Hydraulic connections
uWith fields arranged on top of each
other
• Connect the supply (outlet with opening
for collector sensor) (1) on top.
• Insert the collector sensor into the corre-
sponding opening in the supply.
• Connect the return (inlet) (2) at the bot-
tom.
• Mount the plug without valve (3) in the
lower part of both collectors.
• Mount the plug with bleeding valve (4) on
top of both collectors.
• Fix connections and plugs with the clamps.
• Connect the collector supply and return to
the system with the connection pipes.
• If necessary check the connections for
leaks.
1
Fig. 4.20 Fixing the lower side sections
uWith fields arranged on top of each
other
• Slide the longer side sections (from exten-
sion kit, Article No. 0020059911) laterally
over the lower collector.
• Make sure that the side section is on the
collector frame and that it is locked.
• Fix the longer side sections to the roof bat-
tens with the supplied brackets (1) and
No. 2 screws using the supplied Torx bit.
Installation manual auroTHERM 0020057148_0316
4 Installation

17Installation manual auroTHERM 0020057148_03
2
2
1
Fig. 4.21 Fixing the horizontal intermediate plates
uWith fields arranged on top of each
other
• Slide the intermediate plates into each
other (1).
• Slide the horizontal intermediate plates be-
tween the collector edge and the interme-
diate plate (2).
• Slide the plates over the upper edge of the
lower collector until they can be felt lock-
ing .
1
Fig. 4.22 Fixing the upper side sections
uWith fields arranged on top of each
other
• Slide the shorter side sections (from basic
kit, Article No. 0020059906) laterally over
the upper collector.
• Make sure that the side section is on the
collector frame and that it is locked.
• Fix the side sections to the roof battens
with the supplied brackets (1) and bolts
no. 2 using the supplied Torx bit.
2
1
2
1
a
A
B
Fig. 4.23 Mounting the hydraulic connection pipes
nWith fields arranged side by side
• Insert the pipe couplings into the side
openings of the collector (1) up to the stop.
• Fix the pipe couplings with clamps (2).
aCaution!
Danger of damage to the collector as
a result of incorrect assembly!
Make sure that the clamp (A) slides
into the slot in the pipe coupler (B).
Installation 4
GB

Installation manual auroTHERM 0020057148_0318
1
3
2
a
A
B
Fig. 4.24 Inserting the remaining collectors
nWith fields arranged side by side
• Hook the next collector to the straps of the
front sections (1).
• Compress the collectors (2) and align them
with the marks on the front sections.
The pipe couplings should slip and fit in
the side openings.
• Make sure that the right side of the moved
collector slips under the retainer clamps of
the adjacent collector.
• Fix the pipe couplings with clamps (3).
• With the supplied Torx bit screw the collec-
tor laterally to the roof battens with 4 sup-
plied clamps and bolts no. 3 (see Fig. 4.14).
aCaution!
Danger of damage to the collector as
a result of incorrect assembly!
Make sure that the clamp (A) slides
into the slot in the pipe coupler (B).
1
2
3
4
Fig. 4.25 Mounting the hydraulic connections (1-5 collectors)
nWith fields arranged side by side
• Connect the supply (outlet with opening
for collector sensor) (1) on top.
• Insert the collector sensor into the corre-
sponding opening in the supply.
• Connect the return (inlet) (2) at the bot-
tom.
• Mount the plug without valve (3) in the
lower part of the collector.
• Mount the plug with bleeding valve (4) in
the highest position.
• Fix connections and plugs with the clamps.
• Connect the collector supply and return to
the system with the connection pipes.
• If necessary check the connections for
leaks.
4 Installation

19Installation manual auroTHERM 0020057148_03
1
2
3
4
Fig. 4.26 Mounting the hydraulic connections (6-12 collectors)
nWith fields arranged side by side
hNote
If you connect 6 or more collectors
one after another, the hydraulic con-
nections must be arranged diagonal-
ly, to force a complete flow.
• Insert the return (inlet) (2) in the lower
side opening on one side and, diagonally
across it, the supply (outlet with opening
for collector sensor) (4) into the upper
side opening.
• Insert the collector sensor into the corre-
sponding opening in the supply.
• Fix connections and plugs with the clamps.
• Mount the plug without valve (3) in the
lower part of the collector.
• Mount the plug with bleeding valve (1) in
the highest position.
• Connect the collector supply and return to
the system with the connection pipes.
• If necessary check the connections for
leaks.
1
Fig. 4.27 Screwing the side sections
nWith fields arranged side by side
• Fix the side sections to the roof battens
with the supplied brackets (1) and bolts no.
2 using the supplied Torx bit.
• Make sure that the side section is on the
collector frame and that it is locked.
Installation 4
GB
This manual suits for next models
2
Table of contents
Popular Rack & Stand manuals by other brands

Riley Hopkins
Riley Hopkins RileyFLASH 16x16 Assembly instructions

Verkada
Verkada ACC-MNT-CORNER-1 installation guide

Audio Visual Furniture
Audio Visual Furniture PM2-S Assembly instructions

Novopro
Novopro LIG300 instruction manual

Buffalo
Buffalo TeraStation Installation

peerless-AV
peerless-AV PM 610 Installation and assembly