TABLE OF CONTENTS
WWW.CLEANCOMFORT.COM
2IO-VENT-SS
Notice: Prior to installing, serious consideraon must
be taken to ensure this venlaon system will operate
properly if integrated with any other type of mechanical
system such as a forced air system or an air handling unit.
To ensure proper operaon and compabilies of both
systems, the airows of the Heat Recovery Venlator
(HRV) or Energy Recovery Venlator (ERV) must be
balanced by the installer, by following the procedures
found in this manual.
The way in which your HRV/ERV is installed may make a
signicant dierence to the electrical energy consumed
when operang. To minimize the electricity use of the
HRV/ERV, a stand-alone fully ducted installaon is
recommended. If you choose a simplied installaon that
operates your furnace or air handler for room-to-room
venlaon, electrical energy consumpon and operang
cost will be greatly reduced if the blower of the system's
furnace or air handler has an electronically commutated
(ECM) motor.
Limitations: The product is for residenal applicaons
only and must be installed in accordance with all naonal
and local regulaons, building and safety codes.
*INSTALLATION DATE (MM/DD/YYYY) ( / / )
________________________________________________________________
MODEL#: ____________________________________________________
SERIAL #: _____________________________________________________
*Ask Dealer to provide this information.
Proprietary Notice
This document and the informaon disclosed herein are
proprietary data of Daikin North America LLC. Neither this
document nor the informaon contained herein shall be
reproduced, used, or disclosed to others without the
wrien authorizaon of Daikin North America LLC except
to the extent required for installaon or maintenance
of recipient’s equipment.
Liability Notice
Daikin North America LLC does not accept any liability for
installaons of venlaon equipment installed by unqualied
personnel or the use of parts/components/equipment that are
not authorized or approved by Daikin.
Our connuing commitment to quality products may
mean a change in specicaons without noce.
© 2015 DAIKIN NORTH AMERICA LLC
All rights reserved.
Houston, Texas • USA
www.cleancomfort.com
1-888-724-5211
iCAUTION!
Do not install in a cooking area or connect directly
to any appliance. Turn o all integral disconnects
before servicing.
SAFETY CONSIDERATIONS ................................ 3
VENTILATION REQUIREMENTS ........................ 4
Determine Your Venlaon Needs 4
FITTING EQUIVALENT LENGTHS ...................... 5
TYPES OF INSTALLATIONS ............................... 6
Independent System installaon 6
Exhaust at the Source and Supply in the Return 6
Exhaust and Supply in the Return 7
Installaon Kit 7
Finding a Suitable Installaon Area HRV or ERV 7
INSTALLATION .................................................. 8
Installaon of the HRV / ERV 8
Insulated Flex from Unit to Outside Wall 8
Condensaon Drain Line 9
Supplying Power to the HRV/ERV 9
Installing Venlaon Hoods 10
MATRIX™ Venlaon Hoods 10
CONTROLS WIRING ......................................... 11
Controls Connecon 11
Wiring Diagrams for Furnace interlock systems 11
Alternate Forced-air Interlocking Wiring 12
SEQUENCE OF OPERATIONS ........................... 13
Sequence of Operaons for Venlator and
Connected Wall Controls and Timer 13
VENTILATION CONTROL ................................. 13
BALANCING THE UNIT .................................... 14
TROUBLESHOOTING ....................................... 16
MAINTENANCE ................................................ 17
WARRANTY ...................................................... 18