Page 20
Victrix Zeus Superior 26/32kW Instructions
could be due to a fault in the flue flow meter detected after restoring the electric mains voltage If this per-
sists, contact a qualified technician for assistance
16. Fan fault. This occurs if the fan has a mechanical or electrical fault To eliminate the “fan
fault” the Reset button “C” must be pressed If this fault persists, contact a qualified technician for assis-
tance
20. Parasite flame block. This occurs in case of a leak on the detection circuit or fault in the flame control
unit The boiler can be reset in order to allow a new ignition attempt If the boiler does not start, contact a
qualified technician for assistance
23. Return probe error. In this condition the boiler does not correctly control the pump if set as “Auto”
The boiler continues functioning but to eliminate the error, contact a qualified technician for assistance
24. Push button control panel fault. This occurs when the circuit board detects a fault on the
push button control panel If normal conditions are restored the boiler restarts without having to
be reset If this fault persists, contact a qualified technician for assistance
27. Insufficient circulation. This occurs if there is overheating in the boiler due to insufficient water
circulating in the primary circuit; the causes can be:
- low circulation; check that no interception devices are closed on the central heating circuit and that
the system is free of air (deaerated);
- circulating pump blocked; free the circulating pump
If this occurs frequently, contact a qualified technician for assistance
31. Loss of remote control communication. This occurs in the case of connection to a remote
control that is not compatible or if there is a loss of communication between the boiler and CAR remote con-
trol or Super CAR remote control Try the connection procedure again by turning the boiler off and then
back on again If the Remote Control is still not detected on re-starting the boiler will switch to local
operating mode, i e using the controls on the boiler itself In this case the boiler cannot activate
the “CH ON” function To make the boiler function in “CH ON” mode, activate the “P33” function pre-
sent inside the “M3” menu If this occurs frequently, contact a qualified technician for assistance
37. Low power supply voltage This occurs when the power supply voltage is lower than the allowed limits
for the correct functioning of the boiler If normal conditions are restored, the boiler restarts without having
to be reset If this occurs frequently, contact a qualified technician for assistance
38. Loss of flame signal This occurs when the boiler is ignited correctly and the burner flame switches off
unexpectedly; a new attempt at ignition is performed and if normal conditions are restored, the boiler
does not have to be reset (this error can be checked in the list of errors P19 present in the “M1” menu) If
this incident occurs frequently, contact a qualified technician for assistance
Other maintenance operations :
Lack of water in boiler.
Not enough water pressure detected in the heating circuit to guarantee correct boiler operation Make sure
that the pressure in the system is between 1 and 1 2 bar N B Close the valve on completion If pressure
valves reach around 3 bar the safety valve may be activated In this case contact a professional technician
for assistance In the event of frequent pressure drops, contact qualified personnel for assistance to elimi-
nate system leakage
Syste flow NTC sensor fault.
If the unit detects a problem with the system delivery NTC sensor, the boiler will not start; call a qualified
technician
Do estic circuit NTC sensor fault.
If the unit detects a problem in the domestic circuit NTC sensor, the boiler will not produce domestic hot
water; call a qualified technician
No water circulating.
This occurs if there is overheating in the boiler due to insufficient water circulation through the boiler
-
check
that no shutoff devices are closed and that the system is free of air Check that the circulating pump is run-
ning freel
y.
If necessary, remove the pump cover screw and manually rotate the pump impellor using a flat
bladed screwdriver If lockout occurs repeatedly, contact a qualified technician for assistance
Draining the syste .
To drain the boiler, use the special drain cock Before draining, ensure that the filling valve is not con-
nected closed
Draining the boiler.
To drain the boiler, use the special drain cock N B : Before carrying out this operation, close the boiler cold
water inlet cock and open any domestic circuit hot water cock to allow air to enter the boiler