Victrix Zeus Superior 26/32kW Instructions
Flue Systems
When the boiler is installed on an external wall, the standard horizontal concentric 60/100 flue kit will normally
be used to flue the boiler This is shown in the diagram
It is often necessary to install a longer flue system to cater for site conditions There are several different flue
system sizes available for the Victrix Zeus 20/27 boiler
Horizontal concentric kit 60 /100
Install the bend with flange (2) on the left hole of the boiler insert-
ing the seal (1) with the round protrusions facing downwards in con-
tact with boiler flange and tighten using the screws supplied with
the kit
Fit the smooth male end of the 60/100 concentric terminal pipe (3)
until it reaches to the stop on the female end of the bend (2), mak-
ing sure the internal and external sealing rings are fitted; this will
ensure the connection is properly sealed Additional extensions
and bends may be installed if required using the same method
Ensure that all seals are fitted and that the outer and inner pipes
are installed so that all joints are perfectly sealed Ensure that the
terminal is installed the right way up
A lubricant may assist in overcoming the friction of the seals Oils
and conventional greases are not compatible with the EPDM seals
used and should never be used for this purpose Talc may be
used Please contact RVR for more information
A rigid supporting clamp should be fitted on each 1 0 metre or 2 0
metre flue extension in all cases The flue system should be inclined at a minimum slope of 1% so that conden-
sate flows towards the boiler The elbow above the boiler is the low point of the flue system and the terminal at
the outside wall is the high point of the system The fall should be continuous over the full length of the flue sys-
tem and the there should be no low points which would allow condensate to build up within the flue pipes This
avoids any drips from the external flue terminal
The maximum possible overall length after the first bend (2)
is 12.9 straight and horizontal meters. See the section on
extended flue design for more information.
Vertical concentric kit 60 /100
Install the concentric flange (2) on the left hole of the boiler in-
serting the seal (1) with the round protrusions facing downwards
in contact with boiler flange and tighten using the screws sup-
plied with the kit
Fit the male end (smooth) of the adapter (3) in the female end of
the concentric flange (2) until it reaches the stop on the female
end of the flange, making sure the internal and external sealing
rings are fitted; this will ensure the connection is properly sealed
Additional extensions and bends may be installed if required us-
ing the same method
Installing the flashing- Replace tiles with the aluminium sheet (5),
shaping it to ensure that the rainwater runs off Position the fixed
half-shell (7) on the aluminium tile and insert the intake/exhaust
pipe (6) Fit the male end (6)(smooth) of the 60/100 concentric
terminal up to the stop on the female end of the adapter(3),
making sure that the ring (4) is already fitted; this will ensure hold and joining of the elements making up the kit
Ensure that all seals are fitted and that the outer and inner pipes are installed so that all joints are perfectly
sealed A lubricant may assist in overcoming the friction of the seals Oils and conventional greases are not com-
patible with the EPDM seals used and should never be used for this purpose Talc may be used Please contact
RVR for more information
A rigid supporting clamp should be fitted on each 1 0 metre or 2 0 metre flue extension in all cases
The maximum possible overall length including the terminal is 14.4 straight and horizontal meters.
NB: If the terminal or extension pipes need shortening ensure that the inner pipe protrudes by 5mm with
Figure 7—Horizo tal co ce tric kit
Figure 8—Vertical co ce tric kit
The kit i cludes :
N° 1 - Gasket (1)
N° 1 - Female
co ce tric fla ge (2)
N° 1 - Wall seali g
plate (3)
N° 1 - Alumi ium
tile (4)
N° 1 - Co ce tric
termi al i t./exhaust
Ø
60/100 (5)
N° 1 - Fixed half-
shell (6)
N° 1 - Mobile half-
shell (7)
The kit i cludes:
N° 1 - Gasket (1)
N° 1 - Co ce tric be d Ø 60/100 (2)
N° 1 - Co ce tric termi al i t./exhaust Ø
60/100 (3)
N° 1 - I ter al white wall seali g plate (4)
N° 1 - Exter al grey wall seali g plate (5)