The following safety precautions must be taken when using your air
conditioner.
SAFETY PRECAUTIONS
1. Warning: Prior to repair, disconnect the power cord.
2. Use proper parts: use only exact replacement parts. (Also, we recommend replacing parts rather
than repairing them.)
3. Use the proper tools: use the proper tools and test equipment, and know how to use them. Using
defective tools or test equipment may cause problems later-intermittent contact, for example.
4. Power cord: prior to repair, check the power cord and replace it if necessary.
5. Avoid using an extension cord, and avoid tapping into a power cord. This practice may result in
malfunction or fire.
6. After completing repairs and reassembly, check the insulation resistance.
Procedure: prior to applying power, measure the resistance between the power cord and the ground
terminal. The resistance must be greater than 30 megohms.
7. Make sure that the grounds are adequate.
8. Make sure that the installation conditions are satisfactory. Relocate the unit if necessary.
9. Keep children away from the unit while it is being repaired.
10. Be sure to clean the unit and its surrounding area.
1
2
Location of indoor unit
A place solid enough to bear the weight of the unit and not cause any shake.
Good ventilation, less dust, far from direct rain and sunshine.
Avoid places close to inflammable gas leakage.
Keep the air inlet and outlet at a far distance from the blockage.
Keep the height distance between the indoor and outdoor unit at most 5m.
Mount on the wall solid enough to bear the weight of the unit and not cause any shake.
Avoid direct sunshine.
A place easy for condensate drain and easy for connecting with the outdoor unit.
Keep a far distance away from the fluorescent lamp, it may influence the operation of remote controller.
Location of outdoor unit
Keep at least 1m away from the TV radio and other home appliances.
A place where the air discharged out of the outdoor unit or the operation noise will not annoy your
neighbours.
No blockage near the outdoor unit.
Avoid places close to inflammable gas leakage.
Selecting area for installation
INSTALLATION
Select an area for installation that is suitable to the customers needs.
It is harmful to the air conditioner if it is used in the following environments: greasy areas (including area
near machines). Salty area such as coastal areas, areas where sulfuric gas is present such as hot spring
areas. Contact your dealer for advice.
Caution:
2
All manuals and user guides at all-guides.com
front
right
back
Underside Left-back
back
Notice: do not elevate the
drain hose.
The copper pipe can be led
from back, right, underside,
or left-back side.
Cover connecting pipe with
adiabatic material.
Sponge plastic adiabatic
material with the
thickness of 8mm.
While installing the pipeline on the
thin armor plate or on the wall of
metal mesh, you should use the
wooden board to clamp between
the wall and the pipeline, or wrap
up the pipeline with 7-8 layers of
insulating plastic tape.
left
100mm以上
above 300mm
above 500mm
above 300mm
above 500mm
above 500mm
INSTALLATION
Installation diagram of indoor unit and outdoor unit
Confirm the installation position by the mark of the indoor mounting plate.
or
or or
above 155mm
above 250mm
Above 20mm
above 105mm
3
All manuals and user guides at all-guides.com
Securing the mounting plate and drill on the wall
1
Secure the mounting plate
The mounting plate should be attached to the structural part of wall (post etc).
fasten string at the central hole
105mm or more
from sidewall
155mm or more
at least 250mm
from sidewall
Tapping screw
ST4×25(5)
mounting plate
NOTICE: The holes at solid arrow position must be secured to avoid the shake of mounting plate.
When the expansion bolts are used, two holes ( 11×20 or 11×26 ) that the distance
between them is 450mm should be adopted.
Drill on the wall
Center of hole( 65mm)
Confirm the position of holes, and drill holes on the wall.
NOTICE:
Fasten string at the central hole
105mm or more
from sidewall 455mm or more
at least 250mm
from sidewall
Tapping screw
ST4×25(5)
mounting plate
plumb
40mm
at least 24mm
plumb
fasten string at the central hole
105mm
45mm
Center of hole( 65mm)
plumb
NOTICE:
The holes at solid arrow position must be secured to avoid the shake of mounting plate.
When the expansion bolts are used, two holes ( 11×20 or 11×26 ) that the distance
between them is 450mm should be adopted.
Confirm the position of holes, and drill holes on the wall.
INSTALLATION
440mm
fasten string at the central hole
at least250mm
230mm
440mm
at least 120mm
at least 120mm
Φ
90mm
plumb
Φ
90mm
Pipe hole
40mm
Pipe hole
plumb
fasten string at the central hole
at least 250mm
at least 180mm
at least 140mm
120mm
Center of hole( ) 65mm
Center of hole( ) 65mm
4
All manuals and user guides at all-guides.com

This manual suits for next models

2

Other Vivax cool Air Conditioner manuals

Vivax cool ACP-09CH25GEK/I User manual

Vivax cool

Vivax cool ACP-09CH25GEK/I User manual

Vivax cool ACP-18CH2525AEL User manual

Vivax cool

Vivax cool ACP-18CH2525AEL User manual

Vivax cool ACP-09PT25GN User manual

Vivax cool

Vivax cool ACP-09PT25GN User manual

Vivax cool ACP-12CTIFM35GECI User manual

Vivax cool

Vivax cool ACP-12CTIFM35GECI User manual

Vivax cool ACP-12CC35GECI User manual

Vivax cool

Vivax cool ACP-12CC35GECI User manual

Vivax cool ACP-09CH25AEI/I User manual

Vivax cool

Vivax cool ACP-09CH25AEI/I User manual

Vivax cool ACP-18CH50GEK User manual

Vivax cool

Vivax cool ACP-18CH50GEK User manual

Vivax cool ACP-24CH70GEEO User manual

Vivax cool

Vivax cool ACP-24CH70GEEO User manual

Popular Air Conditioner manuals by other brands

Fujitsu ASYG 09 LLCA installation manual

Fujitsu

Fujitsu ASYG 09 LLCA installation manual

York HVHC 07-12DS Installation & owner's manual

York

York HVHC 07-12DS Installation & owner's manual

Carrier Fan Coil 42B Installation, operation and maintenance manual

Carrier

Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity IDUFCI60KC-3 installation manual

intensity

intensity IDUFCI60KC-3 installation manual

Frigidaire FAC064K7A2 Factory parts catalog

Frigidaire

Frigidaire FAC064K7A2 Factory parts catalog

Sanyo KS2432 instruction manual

Sanyo

Sanyo KS2432 instruction manual

LG MultiV Series installation manual

LG

LG MultiV Series installation manual

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

CLIMAVENETA

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

Midea EWK06CW5 user manual

Midea

Midea EWK06CW5 user manual

Pioneer FAB Series installation manual

Pioneer

Pioneer FAB Series installation manual

SPT WA-1511S user manual

SPT

SPT WA-1511S user manual

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Mitsubishi Electric

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic CS-S18HKQ Service manual

Panasonic

Panasonic CS-S18HKQ Service manual

Panasonic CS-E15NKE3 operating instructions

Panasonic

Panasonic CS-E15NKE3 operating instructions

Gree GWH18TC-K3DNA1B/I Service manual

Gree

Gree GWH18TC-K3DNA1B/I Service manual

Friedrich ZoneAire Compact P08SA owner's manual

Friedrich

Friedrich ZoneAire Compact P08SA owner's manual

Daikin R32 Split Series installation manual

Daikin

Daikin R32 Split Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.