Description
Model 9700B AQUA-TIGER
Bronze Centrifugal DC Pump
Installation, Operation, Repair and Parts Manual
Form 335C
General Safety Information
1. WARNING: DO NOT pump solvents, thinners or
gasoline, as explosion may result causing personal
injury or death and/or property damage. DO NOT
use in explosive atmospheres. The pump should be
used only with liquids compatible with the pump
component materials. Failure to follow this warning
will void the product warranty.
2. WARNING: DO NOT operate with any of the mount-
ing bolts removed from the motor case. Explosion
resulting in personal injury, death or property dam-
age may occur. Case openings must be sealed to
avoid explosion and maintain ignition protected
rating.
3. Do not pump liquids at temperatures higher than the
recommended maximum temperatures (140oF).
4. Disconnect power before servicing.
5. Drain all liquids from the system before servicing any
component.
6. Check hose for weak or worn condition before each use.
Make certain that all connections are tight and secure.
7. Periodically inspect the pump and the system compo-
nents. Perform routine maintenance as required (see
Maintenance section).
8. Do not use these pumps for pumping water or other
liquids for human or animal consumption.
SPECIFICATIONS
Body and Impeller: .......................................... Bronze
Seal: ...................................................... Lip type Viton*
Port Size: ................................................ 3/4 " NPT (F)
Max. Temperature: ............................................. 140oF
Max. PSI: ........................................................... 7.0 psi
Max. Current: ............................................... 5.0 Amps
Weight: ........................................ 5 lb (2.3 kg) approx.
Motor: ...................... Stainless steel shaft, permanent
magnet, fully enclosed, ignition
protected.
Model 9700B-12V D.C.
APPLICATION
The Aqua-Tiger is suitable for general pumping applications
where a flooded intake is provided. Typical applications
include livewell filling and circulation, and any other appli-
cation not requiring a self-priming pump.
09/01
Performance Chart
VOLTS PSI AMPS GPM
13.5
(Alternator)
Engine
Running
1 5.5 19.0
2 5.3 16.5
3 5.0 14.0
4 4.9 12.5
5 4.5 10.0
64.1 6.5
73.7 2.7
Model 9700B Aqua-Tiger
-2-
1. Always drain and flush the pump before servicing or
disassembling for any reason (see instructions).
2. Always drain and flush pumps prior to returning unit for
repair.
3. Never store pumps containing hazardous chemicals.
4. Before returning the pump for service/repair, drain out
all liquids and flush the unit with neutralizing liquid.
Then, drain the pump. Attach a tag or include a written
notice certifying that this has been done. Please note
that it is illegal to ship or transport any hazardous
chemicals without United States Environmental Protec-
tion Agency Licensing.
Hazardous Substance Safety Information
The pump must be mounted in a dry location. The motor is
not waterproof; therefore, it must not be submerged. The
unit can be operated in any positon. It is advantageous to
mount the pumps so the water dripping from a loose port
connection will not wet the motor. The pump head may be
mounted at 90oincrements on the motor to allow mounting
as needed.
Installation and Operation
ELECTRICAL HOOKUP
WARNING: If the pump is operated in an area containing
flammable vapors, wire leads must be joined by insulated
mechanical locking connectors. Loose or inadequate
wire connections can spark resulting in explosion. Prop-
erty damage, injury or death may occur.
CAUTION: Lead wires on the motor must not be
shortened or the warranty will be voided.
Positive terminal of the battery is connected to an overload
protected distribution panel. The red lead with the fuse holder
is connected to the distribution panel. The black wire is
connected to the negative terminal of the battery. For proper
operation, the motor must rotate clockwise when viewed from
the pump end. The proper sized fuse has been installed in the
fuse holder. If this fuse blows, replace it with the same size
fuse after determining the reason for the blown fuse. Use the
proper wire size as determined by the wiring table.
OPERATION
Try not to run the pump dry because doing so shortens the
seal life. If you must run the pump dry, do so only for short
periods of time. The pump may run against a closed outlet.
Small particles will pass through the pump, so a 50-mesh
intake strainer should be fitted to the pump.
CAUTION: The motor runs hot, up to 180oF on the motor
case. Contact during operation may cause a burn.
Red Wire
Fuse
Outlet
Inlet
Black Wire
Overload Protected
Distribution Panel
Wiring Table for 9700B
Connection length
between battery Wire Gage
and motor
1-10 ft. ................................... #12
11-20 ft. ................................. #10
12-30 ft. .................................. #8
Fuse Sizes for 9700B
Approximate Amp Draw ....... 8
Fuse Size ............................ 10
Model 9700B-12DC
MAINTENANCE
Check all electrical and plumbing connections periodically.
In salt water applications, corrosion of the electrical connec-
tions can cause a loss of performance or non-operation. The
motor should be protected with a corrosion inhibiting spray.
Any rust should be removed and the motor repainted.
DISASSEMBLY
1. Remove the cover screws, cover and o-ring.
2. Remove the pipe plug on the side of the housing and
rotate the impeller so the set screw aligns with the plug
hole. Insert a 3/32" allen wrench through the plug hole
and loosen the impeller set screw. Remove the impeller.
3. Remove the screws that secure the housing to the
motor, and remove the housing.
4. From the inside of the housing, insert a dowel into the
seal area and press the seal out of the seal bore.
ASSEMBLY
1. From the rear of the housing, press the seal into the seal
bore with the open lip toward the pump cavity.
2. Apply a small amount of grease to the motor shaft in the
area where the seal contacts it. Slide the housing onto
the shaft and secure it to the motor with the (2) two hex
head screws.
3. Align the impeller set screw with the flat on the motor
shaft and slide the impeller onto the shaft until it contacts
the rear of the housing. Slide the impeller forward 1/32"-
1/16" and secure it with the set screw. Rotate the
impeller by hand to ensure that it does not rub on the
housing. Reinstall the pump plug in the housing.
4. Clean the surfaces of the cover and housing where they
make contact. A small amount of grease on the o-ring
will ease installation. Place the o-ring on the cover.
Align the cover with the housing and secure it with the (3)
three cover screws and lock washers.
Maintenance
Ref. Qnty. Part
No. Req'd. Number Description Ref. Qnty. Part
No. Req'd. Number Description
IMPORTANT:
When ordering parts, give PART NUMBER
and PART DESCRIPTION. Reference
Numbers are used ONLY to point out parts
in the drawing and are NOT to be used as
ordering numbers.
1 3 9940-12686 Cover Screw
2 3 9940-343 Lock Washer
3 1 9940-19893 Cover
4 1 9940-19929 Set Screw
5 2 9940-19927 Hex Head Screw
6 1 9940-336 Pipe Plug
7 1 9940-19891 Housing
8 1 9940-19928 Seal, Viton*
9 1 9940-19898 O-ring, Viton*
10 1 9940-19892 Impeller
11 4 9940-21138 Grommet
12 1 9940-19926 Motor 12VDC (9700B)
*Viton is a trademark of E.I. Dupont deNemour and Company
2001 Hypro Corporation
Limited Warranty on Hypro Pumps and Other Hypro Products
Care of the Pump
AFTER USE PUMP CARE
A. GUMMING — Gumming or corrosion inside the pump can
be prevented by thoroughly flushing the pump clean with
water or a liquid that will neutralize the liquid pumped. (For
many liquids, a solution of 1 gallon ammonia mixed with
6 gallons of water works well.)
B. To PREVENT RUST/CORROSION, we recommend
(after Step A) flushing the pump with permanent-type
automobile radiator antifreeze containing a rust inhibitor,
and then preventing air from getting in the pump. Use a 50-
50 solution of antifreeze and water. Flush it through the
pump, and then drain it. Plug the ports to keep air from
getting into the pump during storage. Cleaning and rust
protection should be done when the pump will be stored
away for more than two to three days.
Hypro Corporation (“Hypro”) warrants to the original purchaser of its products (the “Purchaser”) that such products will be free from defects in
material and workmanship under normal use for the period of one (1) year for all products except: oil crankcase plunger pumps will be free from
defects in material and workmanship under normal use for the period of five (5) years, and accessories will be free from defects in material and
workmanship under normal use for the period of ninety (90) days. In addition, Hypro warrants to the purchaser all forged brass pump manifolds
will be free from defects in material and workmanship under normal use and from damage resulting from environmental conditions for the life of the pump.
“Normal use” does not include use in excess of recommended maximum speeds, pressures, vacuums and temperatures, or use requiring
handling of fluids not compatible with component materials, as noted in Hypro product catalogs, technical literature, and instructions. This
warranty does not cover freight damage, freezing damage, normal wear and tear, or damage caused by misapplication, fault, negligence,
alterations, or repair that affects the performance or reliability of the product.
THIS WARRANTY IS EXCLUSIVE. HYPRO MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Hypro’s obligation under this warranty is, at Hypro’s option, to either repair or replace the product upon return of the entire product to the Hypro
factory in accordance with the return procedures set forth below. THIS IS THE EXCLUSIVE REMEDY FOR ANY BREACH OF WARRANTY.
IN NO EVENT SHALL HYPRO BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND, WHETHER FOR
BREACH OF ANY WARRANTY, FOR NEGLIGENCE, ON THE BASIS OF STRICT LIABILITY, OR OTHERWISE.
Return Procedures
All pumps or products must be flushed of any chemical (ref. OSHA Section 0910.1200 (d)(e)(f)(g)(h)) and hazardous chemicals must
be labeled before being shipped* to Hypro for service or warranty consideration. Hypro reserves the right to request a Material Safety
Data sheet from the Purchaser for any pump or product Hypro deems necessary. Hypro reserves the right to “disposition as scrap” pumps or
products returned which contain unknown substances, or to charge for any and all costs incurred for chemical testing and proper disposal of
components containing unknown substances. Hypro requests this in order to protect the environment and personnel from the hazards of
handling unknown substances.
For technical or application assistance, call the Hypro Technical/Application number: 1-800-445-8360.
The Hypro Service and Warranty number is: 1-800-468-3428, or Hypro Service and Warranty FAX: (651) 766-6618.
*Carriers, including U.S.P.S., airlines, UPS, ground freight, etc., require specific identification of any hazardous materials being shipped.
Failure to do so may result in a substantial fine and/or prison term. Check with your shipping company for specific instructions.
Dimensions are in inches.

This manual suits for next models

1

Popular Water Pump manuals by other brands

Sealey wpd133a quick start guide

Sealey

Sealey wpd133a quick start guide

KSB B Series Installation and operating manual

KSB

KSB B Series Installation and operating manual

Franklin Electric Little Giant 5-APCP instructions

Franklin Electric

Franklin Electric Little Giant 5-APCP instructions

NEPTUN classic NCGP-E 70 Original operating instructions

NEPTUN classic

NEPTUN classic NCGP-E 70 Original operating instructions

GORMAN-RUPP PUMPS 811/4A3-B Installation, operation, and maintenance manual with parts list

GORMAN-RUPP PUMPS

GORMAN-RUPP PUMPS 811/4A3-B Installation, operation, and maintenance manual with parts list

PVA PCP Series Operation manual

PVA

PVA PCP Series Operation manual

Pfeiffer Vacuum HIPACE 350 operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum HIPACE 350 operating instructions

Dover PSG Ebsray R Series Installation, operation & maintenance instructions

Dover

Dover PSG Ebsray R Series Installation, operation & maintenance instructions

Metabo TPF 18 LTX 2200 Original instructions

Metabo

Metabo TPF 18 LTX 2200 Original instructions

Barnant Company PK15 operating manual

Barnant Company

Barnant Company PK15 operating manual

TLV PowerTrap GP10L instruction manual

TLV

TLV PowerTrap GP10L instruction manual

Siccom FLOWITA EVO quick start guide

Siccom

Siccom FLOWITA EVO quick start guide

Glentronics PHCC 2400 Pro Series instruction manual

Glentronics

Glentronics PHCC 2400 Pro Series instruction manual

Pentair MYERS C25 Series Installation and service manual

Pentair

Pentair MYERS C25 Series Installation and service manual

pumpa AD Translation of the original instruction manual

pumpa

pumpa AD Translation of the original instruction manual

Alcatel ADP One Series user manual

Alcatel

Alcatel ADP One Series user manual

Graco 19D873 manual

Graco

Graco 19D873 manual

Rothenberger ROAIRVAC R32 2.0 CL Instructions for use

Rothenberger

Rothenberger ROAIRVAC R32 2.0 CL Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.