Part number 550-142-950/0919 3
FreeStyle® Series 2 wall mount gas-fired water boiler — Boiler Manual
Failure to adhere to the guidelines below can result in severe personal injury, death or substantial property damage.
7HENSERVICINGBOILER
s To avoid electric shock, disconnect all
ELECTRICAL SUPPLIES TO THE BOILER BEFORE
PERFORMINGMAINTENANCE
s To avoid severe burns, allow boiler to
COOLBEFOREPERFORMINGMAINTENANCE
s This boiler contains ceramic fiber and
lBERGLASSMATERIALS2EFERTOTHE7!2.-
).'ANDINSTRUCTIONSON page 25.
"OILEROPERATION
s $ONOT BLOCK mOW OFCOMBUSTIONOR
ventilation air to boiler.
s Should overheating occur or gas supply
FAILTOSHUTOFFDONOTTURNOFFORDISCON-
nect electrical supply to pump. Instead,
SHUTOFF THE GAS SUPPLY AT A LOCATION
external to the appliance.
#OMBUSTIONAIR
s $/./4INSTALLCOMBUSTIONAIRINTAKE
WHERETHEREISARISKOFCOMBUSTIONAIR
contamination.
#ARBONMONOXIDEDETECTOR
s !CARBON MONOXIDEDETECTORTHAT IS
wired on the same electrical circuit as
the boiler is strongly recommended.
352'%02/4%#4/2
s Provide surge protection in the boiler
power supply. This will reduce the pos-
SIBILITYOFDAMAGETOTHEBOILERCONTROL
*
In some locations, a carbon monoxide
detector is required by the law.
"OILERWATER
s The FreeStyleHEATEXCHANGERISMADEOF
stainless steel, and requires that system
water chemistry be within the limits in
this manual. Use Sentinel X100 inhibitor
in the boiler. !$$)4)/.!,#(%-)#!,
42%!4-%.4 -!9"%.%#%33!29. See
page 75FORDETAILS
s Thoroughly flush the system (BEFORE
connecting boiler) to remove sediment.
4HEHIGHEFlCIENCYHEATEXCHANGERCAN
be damaged by build-up or corrosion
due to sediment.
s Do not use petroleum-based cleaning
or sealing compounds in boiler system.
'ASKETSANDSEALSINTHESYSTEMMAYBE
damaged. This can result in substantial
property damage.
s #ONTINUALFRESHMAKEUPWATERWILL
REDUCEBOILER LIFE-INERAL BUILDUP IN
EATEXCHANGERREDUCESHEATTRANSFER
overheats the aluminum heat exchanger,
ANDCAUSESFAILURE!DDITIONOFOXYGEN
carried in by make-up water can cause
internal corrosion. Leaks in boiler or
piping must be repaired at once to
prevent make-up water. Use this boiler
/.,9INACLOSEDLOOPSYSTEM
s Do not add cold water to a hot boiler.
Thermal shock can cause heat exchanger
to crack.
&REEZEPROTECTIONmUIDS
s .%6%2USE AUTOMOTIVEOR STANDARD
GLYCOLANTIFREEZE5SEONLYFREEZEPROTEC-
TIONmUIDSMADEFORHYDRONICSYSTEMS
Follow all guidelines given by the anti-
FREEZEMANUFACTURER4HOROUGHLYCLEAN
and flush any replacement boiler system
THATHASUSEDGLYCOLBEFOREINSTALLINGTHE
new boiler Use only the products listed
BY7ILLIAMSON4HERMOmOFORUSEWITH
this boiler. See page 121FORDETAILS
Frozen Water Damage
Hazard
Residences or buildings that are unat-
tended in severely cold weather, boiler
SYSTEMCOMPONENTSFAILURESPOWEROUT-
AGESOROTHERELECTRICAL SYSTEM FAILURES
COULDRESULTINFROZENPLUMBINGANDWATER
DAMAGEINAMATTEROF HOURS&ORYOUR
protection, take preventative actions such
as having a security system installed that
operates during power outages, senses low
TEMPERATUREANDINITIATESANEFFECTIVEAC-
tion. Consult with your boiler contractor
or a home security agency.
If any part of a boiler, burner or its controls has
been sprayed with or submerged under water,
either partially or fully, DO NOT attempt to op-
erate the boiler until the boiler has been either
replaced or completely repaired, inspected, and
you are sure that the boiler and all components
are in good condition and fully reliable.
Otherwise, by operating this boiler, you will
cause a fire or explosion hazard, and an electrical
shock hazard, leading to serious injury, death, or
substantial property damage. See the instructions
at right.
Saltwater Damage — 4HEEXPOSUREOFBOILER COMPONENTSTO
SALTWATERCANHAVEBOTHIMMEDIATEANDLONGTERMEFFECTS7HILE
THEIMMEDIATEEFFECTSOFSALTWATERDAMAGEARESIMILARTOTHOSEOF
FRESHWATERSHORTINGOUT OF ELECTRICALCOMPONENTS WASHINGOUT
OFCRITICALLUBRICANTSETCTHE SALT AND OTHER CONTAMINANTS LEFT
BEHINDCANLEADTOLONGERTERMISSUESAFTERTHEWATERISGONEDUETO
THECONDUCTIVEANDCORROSIVENATUREOFTHESALTRESIDUE4HEREFORE
Williamson-Thermoflo equipment contaminated with saltwater
or polluted water will no longer be covered under warranty and
should be replaced.
%LECTRICAL $AMAGE)FANYELECTRICAL COMPONENT or wiring
came into contact with water, or was suspected to have come into
contact with water, replace the boiler with a new Williamson-
Thermoflo boiler.
Commonwealth of
Massachusetts
7HENTHEBOILERISINSTALLEDWITHINTHE#OMMONWEALTHOF-ASSACHUSETTS
s This product must be installed by a licensed plumber or gas fitter.
s )FANTIFREEZEISUSEDAREDUCEDPRESSUREBACKmOWPREVENTERDEVICESHALLBEUSED
s Sidewall vent air installations — see instruction on page 18.
)NSTALLER— Read all instructions, including this
MANUALANDALLOTHERINFORMATIONSHIPPEDWITHTHE
BOILERBEFOREINSTALLING0ERFORMSTEPSINTHEORDER
given.
User 4HISMANUALISFORUSEONLYBYAQUALIlED
HEATINGINSTALLERSERVICETECHNICIAN2EFERTO5SERS
)NFORMATION-ANUALFORYOURREFERENCE
User — Have this boiler serviced/inspected by a
qualified service technician, at least annually.
Failure to comply with the above could result in severe
personal injury, death or substantial property damage.
Write in the Consumer Protection (CP) number in
the space provided on the Installation certificate on
page 136IFNOTALREADYSHOWN
When calling or writing about the boiler— Please
HAVETHEBOILERMODELNUMBERFROMTHEBOILERRATING
LABELANDTHE#0NUMBERFROMTHEBOILERJACKET
Consider piping and installation when determining
boiler location.
!NYCLAIMSFORDAMAGEORSHORTAGE IN SHIPMENT
must be filed immediately against the transportation
company by the consignee.
1 Please read before proceeding