1. SAFETY REGULATIONS AND INFORMATION
Read the operating manual carefully before
commencing work at the product. Pay attention to
the following warnings to avoid risk to persons or
malfunctioning. This operating manual is an integral
part of the product. In the event of resale or change
of ownership the operating manual must
accompany the product. This operating manual may
be copied and provided as information on potential
risks and their avoidance.
1.1 Hazard classification of warning notices
The following risk ratings are used in this operating
manual to denote potential risk situations and
important safety instructions:
DANGER:This is a potentially dangerous situation
and warns of an impending health risk or risk of
fatal injury if this warning is not observed. Observe
this warning.
WARNING: The dangerous situation can occur and
can result in major or fatal injuries if the warning is
not observed. Work with extreme care.
CAUTION:The dangerous situation can occur and
can result in minor injuries or damage to property if
the warning is not observed.
NOTE:A potentially dangerous situation can occur
and results in damage to property if not avoided.
1.2 Qualification of personnel
Only skilled electricians are permitted to install the
product, to carry out the test run and to work at the
electrical unit. Only instructed and authorized
skilled personnel are permitted to transport,
unpack, operate and service the product.
1.3 Basic safety regulations
Safety risks related to the product must be
reassessed after installing in the final device. The
operating manual was developed in accordance
with European market requirements and may need
adapting to the market requirements of the country
in question.
Do not make any changes to the product.
WARNING:Impermissible high load
Stop the product immediately after impermissible
loading (e.g. impact, heat, overvoltage).
ADDITIONAL FOR AC-FANS
CAUTTION: In the event of a fault, the product is
energized.
Product has a basic insulation. Do not touch the
product after installing
1.4 Electrical voltage and current
DANGER: Electrical voltage
Regularly check the electrical equipment of the
product. Eliminate immediately loose connections
and defective cables.
1.5 Safety and protective functions
DANGER:Missing safety device and faulty
protective equipment.
Without protective equipment severe injuries can
occur, e.g. by taking hold of the rotating equipment.
Operate the product with protection guards only.
1.6 Electromagnetic radiation
Electromagnetic compatibility (EMC) may affect the
system integration of the product due to
interaction. Ensure the electromagnetic
compatibility of the entire system.
1.7 Moving parts
DANGER: Self-starting product
If voltage is applied, the motor automatically
restarts after a mains failure or when blocking has
been eliminated. Do not stand in the danger zone of

the product. Switch off the mains voltage when
working on the product and secure against
switching on again.
DANGER Rotating impeller:
Contact with the impeller may result in injuries.
Long hair, loose-fitting garments and jewellery can
be caught and pulled into the product. Risk of
injury. Before starting the product, ensure that it is
securely fixed and that the guards are in place. Do
not wear loose-fitting garments or jewellery when
working on moving parts. Protect long hair by
wearing a hair net.
WARNING: Parts transported by the airflow
The product can transport small parts in the airflow
and catapult them out. Ensure that there are no
loose small-parts in the intake and exhaust area. Do
not stand in the danger zone of the product.
CAUTION: High risk of fire spreading
Can cause fire to spread. Never direct the airflow
(intake/exhaust side) at a potential source of fire.
1.8 Hot surface
CAUTION High temperature at motor housing. Risk
of burns
Provide adequate protection against accidental
contact.
1.9 Storage
Store the product in a dry and clean environment
that is well protected. Ensure that the storage
temperature is adhered to. If the product is not
operated for a longer period of time, we
recommend running it for approx. 15 minutes
annually to move the motor bearings.
1.10 Cleaning
NOTE: Product damaged during cleaning
Clean the product carefully with a moist cloth
without applying pressure to the rotor.
Do not use cleaning agents that contain acids,
caustic solutions or solvents.
1.11 Disposal
When disposing of the product, observe all
requirements and regulations that are relevant in
your country.
2. INTENDED USE
The product is designed exclusively as a built-in
device for conveying air according to the technical
data.
Every use that is not in accordance with the
intended purpose, is regarded as misuse of the
product. On-site installations must comply with the
mechanical, thermal and service life requirements.
2.1 Intended use includes:
-Operating the product with all
protective equipment
-Do not put the product into
operation before it has been
installed in the customer's
application
-Observation of the operating manual
2.2 Use for other than the intended purpose
Using the product for the purposes mentioned
below is prohibited and can be dangerous
-Conveyance of air that contains
abrasive particles.
-Conveyance of air that has a highly
corrosive effect.
-Conveyance of air that has a high
dust load, e.g. vacuuming sawdust.
-Conveyance of inflammable
gases/particles.
-Contact with materials that can
damage the product, e.g. acids,
caustic solutions, solvents.
-Exposure to radiation that can
damage product components, e.g.
strong UV rays or thermal radiation.
-Operating during external vibration.
-Operating the product close to
inflammable materials or
components.

-Operating the product in an
explosive atmosphere
-Use of the product as a safety
component or for performing
safetyrelevant functions.
-Operating in medical devices with
life-sustaining or life-saving function,
if not validated.
-Operating in non-stationary systems,
e.g. railway vehicles, aircraft and
spacecraft, if not validated.
-Operating with fully or partially
dismantled or manipulated
protective equipment.
-Operating the product under
conditions other than those
mentioned in the technical data.
-Furthermore, all fields of application
not mentioned under intended use.
An in situ assessment must be conducted of the
heating behavior (appropriate and inappropriate
operation), the protection against contact,
electrical shocks, impact of foreign objects or water
and the usage at altitudes higher than 2000
meters.
3. TECHNICAL DATA
Drawing, see on the backside of packing. The
packing is a part of this operating manual.
Therefore do not dispose the packing.
4. CONNECTION AND COMMISSIONING
4.1 Connect mechanical parts
CAUTION: Risk of cutting/squashing when
removing the product from the packaging and
during mounting.
Grap the housing and lift the product carefully out
of the packaging. Avoid impact.
NOTE: Risk of damage to electronic components.
Use ESD protective equipment when mounting.
4.2 Connect electrical parts
ADDITIONAL FOR AC-FANS
DANGER: Do not touch. Risk of fatal injury from
electrical current
Ensure that the electrical lines are de-energized
Secure the operating voltage against switching on
again. Never work on parts that are energized. Only
allow skilled electricians to work on the product
DANGER: Compliance with the electrical
installation regulations
Observe the connection regulations that are valid in
your country. (e.g. fusing, GFCI)
CAUTION: Electrical voltage - The product is a built-
in component and has no switch for disconnecting
power.
Only connect the product to current circuits that
can be switched off by a switch (all poles
disconnected). When working on the product,
secure the system/machine in which the product is
installed against switching on again.
NOTE:
Electromagnetic compatibility (EMC) may affect the
system integration of the product due to
interaction. Ensure the electromagnetic
compatibility of the entire system.
ADDITIONAL FOR AC-FANS
Ground fault interrupter GFI
Only current-sensitive GFIs (type B) are permissible.
Personal protection is not possible with GFIs when
the product is in operation (see also frequency
converters).
4.3 Requirements:
-Before connecting the product,
ensure that the supply voltage
corresponds with the product
voltage.

-Check whether the data on the
nameplate corresponds with the
interface data.
-Only use cables that are designed for
the current on the nameplate and
the corresponding ambient
conditions.
-Ensure that the electrical interface
data is adequately protected
(mechanical).
Colour
Function
Wire „red“
VCC
Wire „black“
GND
4.4 Check connections
DC-fans ≤ 60V are products of Protection Class lll
and must be operated with safety extra-low
voltage.
AC-Fans are products of Protection Class I and must
be reliably earthed.
4.5 Connect product
Check the product for visible damage and the
operability of protective equipment before
switching on. If damage is visible, do not start the
product.
5. FAULTS, POSSIBLE CAUSES AND REMEDIES
Replace your product by a new one, do not repair it.
DANGER: Electrical voltage at motor
Wait five minutes after the voltage (all poles) has
been switched off before opening the product.
Fault/
Error
Possible cause
Possible remedial
action
Motor is
not
turning
Mechanical
blocking
Switch off,
deenergize and
eliminate
mechanical
blocking
Main voltage
error
Check mains
voltage,
reconnect voltage
supply
Connection
error
Rectify
connection, see
pin connection
Motor too hot
Allow motor to
cool / identify
cause of error
Motor winding
interrupted
Exchange
product.
Ambient
temperature
too high
Reduce ambient
temperature, if
possible
Impeller
out of
true
Unbalance of
rotating parts
Clean product, if
still unbalanced
after cleaning,
exchange
Technical safety Inspection
Require to check
How to
check
Frequency
Protection
against accidental
contact /
Protective
clothing
Visual
Inspectio
n
Min. half a
year.
Check product for
damage
Fixation of
product
Fixation of wires
Insulation of
wires
Check impeller
for wear/
sediments/
corrosion

6. COMPLIANCE
The product bears the CE mark.
The CE mark is affixed to adequately sized
nameplates.
Within the meaning of the EMC Guideline
2014/30/EU this document is intended as:
-Mounting instructions/operating
manual as per Art. 18, Paragraph (1)
-Installation instructions as per Art. 4 -
Operating manual as per Art. 9,
Paragraph (3)
-Instructions for use/operating
manual as per Art. 18, Paragraph (3)
-Maintenance instructions as per
Art.4; Art. 18, Paragraph (1)
Within the meaning of Directive 2014/35/EU -
electrical equipment designed for use within
certain voltage limits this document is intended as:
-Instructions for use/operating
manual as per Art. 6, Paragraph (7);
Art. 8 Paragraph (4)
Within the meaning of the Directive 2006/42/EU
Machine Guideline, this document is intended as
-Mounting instructions as per Art. 13
Errors and Omissions excepted
MOTRAXX ELEKTROGERAETE GmbH
Steinbacher Straße 47-51
90559 Burgthann
Germany
www.motraxx.com
This manual suits for next models
5
Table of contents
Popular Fan manuals by other brands

Hunter Pacific
Hunter Pacific X-OVER DC Installation & user manual

Trane Technologies
Trane Technologies HUV075 Installation, operation and maintenance

Minka Group
Minka Group minkaAire DELANO II Instruction manual warranty certificate

Panasonic
Panasonic F-56MPG Operating and installation instructions

OSTBERG
OSTBERG LPKB 125 B Directions for use

Kichler Lighting
Kichler Lighting IMARI 300365SBK instruction manual