manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. York
  6. •
  7. Furnace
  8. •
  9. York YP8C Quick start guide

York YP8C Quick start guide

TECHNICAL GUIDE
80% MODULATING (ECM MOTOR)
GAS-FIRED RESIDENTIAL
MULTI-POSITION GAS FURNACES
STANDARD & Low NOx MODELS
MODELS: YP8C / YPLC
NATURAL GAS
60 - 120 MBH INPUT
Due to continuous product improvement, specifications are
subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Lifetime limited warranty on heat exchanger to the original purchaser; a
20-year limited warranty from original installation date to subsequent
purchaser.
10-year warranty on the heat exchanger in commercial applications.
Standard 5-year limited parts warranty.
Extended 10-year limited parts warranty when product is regis-
tered online within 90 days of purchase for replacement or closing
for new home construction.
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
402703-YTG-C-0409
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category I listed and may be common vented
with another gas appliance as allowed by the National Fuel Gas
Code.
FEATURES
• Modulating heating operation includes:
- Modulating gas valve, inducer and circulating blower
- Modulating operation from 100% input to 50% input in 1%
increments
• Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
• Compact, easy to install, ideal height 33" tall cabinet.
• ECM variable speed motor for cooling SEER enhancement,
blower delay options for comfort, and continuous fan options
for IAQ performance.
• Easy access to controls to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement application.
• All models are convertable to use propane (LP) gas.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• 100% shut off main gas valve for extra safety.
• 24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Blower door safety switch.
• Solid removable bottom panel allows easy conversion.
• Low NOx models have been designed to meet specific code
requirements.
• Airflow leakage less than 1% of nominal airflow for
ductblaster conditions.
• No knockouts to deal with, making installation easier.
• Movable duct connector flanges for application flexibility.
• Quiet inducer, burner and blower operation.
• Inducer rotates for easy conversion of venting options.
• Fully supported blower assembly for easy access and
removal of blower.
• External air filters used for maximum flexibility in meeting
customers IAQ needs.
• Venting applications - may be installed as a common vent
with other gas-fired appliances.
• Insulated blower compartment for thermal and acoustic
performance.
• 1/4 turn knobs provided for easy door removal.
402703-YTG-C-0409
2Johnson Controls Unitary Products
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
LEFT SIDE RIGHT SIDE
.5”
.5”
RETURN END
B
24.25”
30.25”
28.5”
Gas Pipe
Entry
Thermostat
Wiring
FRONT
14”
1”
1.5”
23”
SUPPLY END
C
24.38”
20”
.5”
B
Gas Pipe
Entry
Thermostat
Wiring
33”
A
.5”
Electrical
Entry
Electrical
Entry
Vent Connection
Outlet
Vent
Connection
Outlet
4” Diameter
Outlet
Vent Connection
Cabinet and Duct Dimensions
Models Nominal
CFM (m3/min) Cabinet
Size Cabinet Dimensions (Inches) Approximate
Operating Weights
A B C Lbs
YP(8,L)C060A12MP11 1200 A 14 1/2 13 1/4 10.3 94
YP(8,L)C080B12MP11 1200 B 17 1/2 16 1/4 11.8 103
YP(8,L)C080C16MP11 1600 C 21 19 3/4 13.6 114
YP(8,L)C100C16MP11 1600 C 21 19 3/4 13.6 118
YP(8,L)C100C20MP11 2000 C 21 19 3/4 13.6 122
YP(8,L)C120C20MP11 2000 C 21 19 3/4 15.8 129
Ratings & Physical / Electrical Data
Models Input
Max/Min Output
Max/Min AFUE Nominal
Airflow Total
Unit
Amps
Air Temp.
Rise Max
Input
Air Temp.
Rise Min
Input
MBH MBH CFM °F °F
YP(8,L)C060A12MP11 60/30 47/24 80.0 1200 7.0 30-60 20-50
YP(8,L)C080B12MP11 80/40 62/32 80.0 1200 7.5 40-70 20-50
YP(8,L)C080C16MP11 80/40 62/32 80.0 1600 10.0 35-65 20-50
YP(8,L)C100C16MP11 100/50 78/40 80.0 1600 10.0 35-65 20-50
YP(8,L)C100C20MP11 100/50 78/40 80.0 2000 12.0 35-65 20-50
YP(8,L)C120C20MP11 120/60 95/48 80.0 2000 12.0 45-75 25-55
Models
Max.
Outlet
Air Temp Blower Blower
Wheel
size
Max
Over-Current
Protect
Min. wire Size
(awg) @ 75 ft
one way
°F HP Amps
YP(8,L)C060A12MP11 160 1/2 4.8 11 x 8 15 14
YP(8,L)C080B12MP11 170 1/2 4.8 11 x 8 15 14
YP(8,L)C080C16MP11 165 3/4 7.5 11 x 10 15 14
YP(8,L)C100C16MP11 165 3/4 7.5 11 x 10 15 14
YP(8,L)C100C20MP11 165 1 14.5 11 x 11 20 12
YP(8,L)C120C20MP11 175 1 14.5 11 x 11 20 12
402703-YTG-C-0409
Johnson Controls Unitary Products 3
FILTER PERFORMANCE
The airflow capacity data published in the “Blower Perfor-
mance” table represents blower performance WITHOUT filters.
All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabi-
net. DO NOT attempt to install any filters inside the furnace.
NOTE: Single side return above 1800 CFM is approved as long
as the filter velocity does not exceed filter manufacturer’s rec-
ommendation and a transition is used to allow use of a 20 x 25
filter.
NOTES:
1.Air velocity through throwaway type filters may not exceed 300 feet per min-
ute (91.4 m/min). All velocities over this require the use of high velocity fil-
ters.
2.Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one return with a transition to allow use of a 20x25 filter.
ACCESSORIES
PROPANE (LP) CONVERSION KIT -
1NP0680 - All Models
This accessory conversion kit may be used to convert natural
gas (N) units for propane (LP) operation.
SIDE RETURN FILTER RACKS -
1SR0200 - All Models
1SR0302 - All Models
1SF0101 - All Models
BOTTOM RETURN FILTER RACKS -
1BR0514 or 1BR0614 - For 14-1/2” cabinets
1BR0517 or 1BR0617 - For 17-1/2” cabinets
1BR0521 or 1BR0621 - For 21” cabinets
1BR05xx series are galvanized steel filter racks. 1BR06xx are
pre-painted steel filter racks to match the appearance of the fur-
nace cabinet.
COMBUSTIBLE FLOOR BASE KIT -
For installation of these furnaces in downflow applications
directly onto combustible flooring material, These kits are
required to prevent potential overheating situations. These kits
are also required in any applications where the furnace in
installed in a downflow configuration without an evaporator coil,
where the combustible floor base kit provides access for com-
bustible airflow.
1CB0514 - For 14-1/2” cabinets
1CB0517 - For 17-1/2” cabinets
1CB0521 - For 21” cabinets
EAC TRANSITION KITS -
For installation of EAC accessories with these furnaces to pro-
vide easy transition of return airflow through the EAC to get the
proper sealing and reduced airflow leakage.
1TK1001 - For all models using side return
1TK1014 - For 14-1/2” cabinets using bottom return
1TK1017 - For 17-1/2” cabinets using bottom return
1TK1021 - For 21” cabinets using bottom return
1TK1024 - For 24-1/2” cabinets using bottom return
HIGH ALTITUDE - No high altitude kits are required.
ROOM THERMOSTATS - A wide selection of compatible ther-
mosets are available to provide optimum performance and fea-
tures for any installation.
1H/1C, manual change-over electronic non-programmable ther-
mostat.
1H/1C, auto/manual changeover, electronic programmable,
deluxe 7-day, thermostat.
1H/1C, auto/manual changeover, electronic programmable.
* For the most current accessory information, refer to the price
book or consult factory.
Recommended Filter Sizes
CFM Cabinet
Size Side
(in) Bottom
(in)
1200 A 16 x 25 14 x 25
1200 B 16 x 25 16 x 25
1600 C 16 x 25 20 x 25
2000 C (2) 16 x 25 20 x 25
Unit Clearances to Combustibles
Application Top Front Rear Left
Side Right
Side Flue Floor/
Bottom Closet Alcove Attic Line
Contact
UpflowB-Vent 130001CombustibleYesYesYes No
DownflowB-Vent130001 11
1. Special floor base or air conditioning coil required for use on combustible floor.
Yes Yes Yes No
HorizontalB-Vent130001CombustibleNoYesYesYes2
2. Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal position) of the furnace jacket and building
joists, studs or framing.
Subject to change without notice. Published in U.S.A. 402703-YTG-C-0409
Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes: 402703-YTG-B-1008
Johnson Controls Unitary Products
5005 York Drive
Norman, OK 73069
All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0”
to 0.6” w.c. static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than
1.0” w.c. external static pressure is not recommended.
NOTE: At some settings, LOW COOL airflow may be lower that what is required to operate an airflow switch on certain models of electronic air cleaners. Con-
sult the instructions for the electronic air cleaner for further details.
Blower Performance CFM - Any Position
High / Low Speed Cooling CFM
060A12 080B12 Jumper Settings
Hi Cool Lo Cool Hi Cool Lo Cool COOL Jumper ADJ Jumper
1340 900 1290 790 H B
1125 750 1065 660 MH B
1225 820 1165 720 H A
1050 680 960 600 MH A
1100 740 1050 590 H C
890 600 855 525 ML B
920 615 875 540 MH C
675 450 640 395 L B
815 545 775 495 ML A
600 440 580 380 L A
720 499 700 430 ML C
540 440 525 380 L C
High / Low Speed Cooling CFM
080C16 100C16 Jumper Settings
Hi Cool Lo Cool Hi Cool Lo Cool COOL Jumper ADJ Jumper
1715 1165 1600 1120 H B
1520 1020 1450 980 MH B
1575 1060 1500 1020 H A
1395 930 1345 900 MH A
1430 950 1315 930 H C
1320 875 1265 845 ML B
1260 840 1210 805 MH C
1100 730 1080 700 L B
1200 795 1165 765 ML A
1000 665 980 635 L A
1080 715 1050 695 ML C
900 600 885 585 L C
High / Low Speed Cooling CFM
100C20 120C20 Jumper Settings
Hi Cool Lo Cool Hi Cool Lo Cool COOL Jumper ADJ Jumper
2110 1360 1990 1290 H B
1670 1085 1760 1030 MH B
1900 1235 1900 1210 H A
1515 990 1510 935 MH A
1710 1130 1800 1095 H C
1465 950 1540 900 ML B
1370 890 1440 845 MH C
1255 815 1320 790 L B
1330 865 1400 835 ML A
1140 740 1200 725 L A
1195 780 1260 750 ML C
1025 665 1080 650 L C

This manual suits for next models

13

Other York Furnace manuals

York TM8V C Series User manual

York

York TM8V C Series User manual

York LC8 Guide

York

York LC8 Guide

York G8C07516(MU,MD)C12 Quick start guide

York

York G8C07516(MU,MD)C12 Quick start guide

York TM9M Quick start guide

York

York TM9M Quick start guide

York AFFINITY PV9A12N040UP11 Quick start guide

York

York AFFINITY PV9A12N040UP11 Quick start guide

York P XD-V Series User manual

York

York P XD-V Series User manual

York PV9 Quick start guide

York

York PV9 Quick start guide

York TG8S Quick start guide

York

York TG8S Quick start guide

York P4UCB30N12206 User manual

York

York P4UCB30N12206 User manual

York Affinity PC9 Manual

York

York Affinity PC9 Manual

York DGU04008U User manual

York

York DGU04008U User manual

York GY9S User manual

York

York GY9S User manual

York PC9B12N060UP11 Quick start guide

York

York PC9B12N060UP11 Quick start guide

York TM9V Quick start guide

York

York TM9V Quick start guide

York AFFINITY PT9 Quick start guide

York

York AFFINITY PT9 Quick start guide

York TP9C Series Guide

York

York TP9C Series Guide

York TM9T Quick start guide

York

York TM9T Quick start guide

York PV9A12N040UP11 Quick start guide

York

York PV9A12N040UP11 Quick start guide

York GF9S*DH User manual

York

York GF9S*DH User manual

York GY8S-DH Quick start guide

York

York GY8S-DH Quick start guide

York TM9V080B12MP11 Quick start guide

York

York TM9V080B12MP11 Quick start guide

York GY8S*UH Series Quick start guide

York

York GY8S*UH Series Quick start guide

York PS9A12N040UP11 Quick start guide

York

York PS9A12N040UP11 Quick start guide

York TG8S Quick start guide

York

York TG8S Quick start guide

Popular Furnace manuals by other brands

Trane UD1A040A9H21B installation guide

Trane

Trane UD1A040A9H21B installation guide

Nordyne TC060 installation instructions

Nordyne

Nordyne TC060 installation instructions

Modine Manufacturing DFP Installation and service manual

Modine Manufacturing

Modine Manufacturing DFP Installation and service manual

KeepRite F96VTN Installation, start-up, operating and service and maintenance instructions

KeepRite

KeepRite F96VTN Installation, start-up, operating and service and maintenance instructions

Unitary products group PV9 installation manual

Unitary products group

Unitary products group PV9 installation manual

Zirkon zahn ZIRCONFEN 600 Operator and  maintenance manual

Zirkon zahn

Zirkon zahn ZIRCONFEN 600 Operator and maintenance manual

Ashley AGDV8 OWNER'S OPERATION AND INSTALLATION MANUAL

Ashley

Ashley AGDV8 OWNER'S OPERATION AND INSTALLATION MANUAL

Lennox G24M SERIES User's information manual

Lennox

Lennox G24M SERIES User's information manual

Drolet TUNDRA II Installation and operating instructions

Drolet

Drolet TUNDRA II Installation and operating instructions

Central Boiler MaXIM M255 PE owner's manual

Central Boiler

Central Boiler MaXIM M255 PE owner's manual

Rinnai EX08C (RHFE-202FTA) Operation and installation manual

Rinnai

Rinnai EX08C (RHFE-202FTA) Operation and installation manual

Lennox G24-200 installation instructions

Lennox

Lennox G24-200 installation instructions

ICP N9MP1 installation instructions

ICP

ICP N9MP1 installation instructions

Nortek L9X1 installation instructions

Nortek

Nortek L9X1 installation instructions

International comfort products C9MVX installation instructions

International comfort products

International comfort products C9MVX installation instructions

USSC Hotblast 1303 owner's manual

USSC

USSC Hotblast 1303 owner's manual

vita VACUMAT 6000 MP manual

vita

vita VACUMAT 6000 MP manual

Heatmor 200X Operation and maintenance manual

Heatmor

Heatmor 200X Operation and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.