  9. 2-Wire WS.503b User manual

2-Wire WS.503b User manual

Qonnex
1
Quick start 2
-
Wire v3.2
WS.503b (MEMo3) web server
The "MEMo3" webserver is a Modbus master module.
All I/O modules are either connected to the RS485 bus
or wirelessly connected via LoRa or FSK at 868MHz.
From the Memo web server, these I/O modules are
then powered, configured, read, logged and logically
switched. Configuration and reading is done via the
web browser on your tablet or PC without the need
for software. The web server also includes http client functionality so that
data can be uploaded to a central server for central management or
backup. With MQTT token, web servers can be linked to each other or one
can get remote access via the APP HTML.
1. Connect:
Power supply MEMo:
(1)Top left of the module, 15 Volts DC via
the included MeanWell HDR-15-30 power
supply. PAY ATTENTION TO POLARITY !!Use
wire with section 0.5mm² and with solid
core to fit in the terminals (2)Fuse this
power supply SEPARATELY 2P/6A
RS485 Modbus:
(3) Data cable: use type EIB bus cable (max.
80m) with section 0.5mm² and with fixed
core to fit into the bus clamps, or use special
Modbus cable for longer distances. Topology Modbus: only in line so no
branches, both bus ends close between A and B terminal with supplied
end resistor 120 Ohm. Memo3 is located at a terminus of the bus.
(3)Connection: depending on the type of module, only make the
necessary connections: Ground(-)black, A yellow, B white, + red (+ is
power supply to module RG.016 and REL.44).
Network:
MEMo3 has both (8)WiFi 2.4 GHz and (4)LAN linking. By default, WiFi is
disabled and LAN is set to DHCP. When you connect to a router, Memo
gets an IP address and this is displayed on the (7) display.
Note: MEMo3 (and PC) MUST always be connected to the internet (load
graphs into PC, upgrade, equalize clock,...)
With a working MEMo3: Short press on the (5) reset button will reboot
the MEMo3, long press on the menu button (6) until the running bar is
finished you will enter the (7) display menu: Here you can upgrade or
clear the MEMo3 completely. Short press (6) to cycle through menu and
long press (6) to activate the selected function.
2. Configuration via tablet or PC:
When the power supply is switched on, the display (7) lights up and after
about 30 seconds* the LAN IP address and port number can be read.
After typing in the IP address+":"+ port number ( e.g. 192.168.0.20:8080)
in the web browser on PC or Tablet (e.g. Google Chrome, Edge, Safari,... )
you will be taken to the web page of the MEMo3 web server. *If WiFi is
turned on, the display will show 'WiFi connect' and it will take a little longer, about
120 seconds before the LAN address appears. For more information, see 'Activating
WiFi via the REDIRECT method'.
At CONFIGURATION/SETUP you can change this LAN IP address by typing
it in the IP address fields or by checking DHCP to give a new IP address by
the router. After modification, press "SEND IP CONFIG" and then press a
2nd time, after which the web server will reboot and after which you can
load the web page with the new IP settings.
Note: If you unplug the RJ45 during rebooting, the MEMo3 will remain in
DHCP mode, which is useful if you go to a new installation to
automatically connect to the network.
To read or change this LAN IP address and network settings or to make
the WiFi connection with your network, you can also use the 2-Wire IP
server scanner: https://www.2-wire.net/product/ip-serverscanner/ From
this Windows tool you can find all web servers within your network. Place
the cursor on the MEMo3 LAN IP address and click on "Set IP and
SSID/Key" to change LAN IP settings, or configure
the WiFi connection from there.
To activate WiFi via the 2-Wire IP server scanner:
Activate WLAN by entering SSID and KEY and then
tick DHCP and press OK. Automatically, the
MEMo3 now gets a free and FIX IP address set
which then appears on the MEMo3 display after
the auto reboot.
Then from this network
WLAN IP address+":"+
port number ( e.g.
192.168.0.21:8080) in
the web browser on PC
or Tablet and then you
will be taken to the web
page of the MEMo3 via
WiFi.
To activate WiFi via the
REDIRECT method:
By briefly pressing the RESET button (5) of MEMo3, it will reboot. During
this reboot, keep pressing the MENU button (6) until first 'Connect WiFi'
and then 'Start WiFi portal' appears, then release. MEMo3 is now an
'access point', called '2WIRE-MEMo'. Choose 'networking' on your laptop
and if it works properly, the list should now read: '2WIRE-MEMO'. Select
this network. If you are asked for a key: 'adminMEMO'. Automatically
your web browser will open and after a maximum of 1 minute you will be
redirected to a REDIRECT screen where you can enter the IP settings.
REDIRECT page:
Fill in the SSID and password of your network and
if you enter your own IP addresses, they must be
adjusted according to the settings of your own
WiFi network. It is easier to enter '0.0.0.0' for the
4 IP addresses and a port number e.g. '8085', and
in this way the web server itself ensures that a
free and fix IP address is set which appears on the
display. Now press "SAVE" and then go back to
default network. Then the WLAN IP address+":"+
port number ( e.g. 192.168.0.21:8080) in the web
browser on PC or Tablet and you will be taken to
the web page of the MEMo3 via WiFi.
The "CONFIGURATION" button will take you to
the webpage below:
 Settings: enter general settings
 Channels: set resolution graphs and overview
page
2.1. Firmware Upgrade:
Go to "CONFIGURATION/SETTINGS" section 5, click on the "FIRMWARE
VERSIONS" button and if your web server has an internet connection, it
will display available version and installed version.
To test the connection, first press "DOWNLOAD" and wait until all the
firmware of the different modules have been downloaded and get a green
tick before upgrading the MEMo3: To do this, press the "INSTALL" button
and the web server will be upgraded.
IMPORTANT: During the upgrade process, DO NOT interrupt the power or
the internet connection or risk damaging the MEMo!! Wait at least a few
minutes for the web server to REBOOT itself and return to the login page.
TIP: You can also upgrade via the (7) display, see detailed manual.
2.2. MODULES, adding energy meters
Logged in as 'Level3'=installer or
'VRM'=expert, you can enter
Modbus meters, MQTT meters or
meters coming from the RF gateway
(RG.016) or Relay interface (REL.44)
from the homepage.
Set Level3: Click on 'EDIT GROUP-CHANNELS'. Enter 'Level3' and click
'CANCEL'. At the top left you can now read the current level status.
Qonnex
2
Quick start 2
-
Wire v3.2
2.3. CHANNELS, Setting Channels:
As an example1, connect a 3 phase EMM.630.
(1) Make sure you are in 'Level3'. (2)Click on 'GROUP1'. (3)Click on 'CH0'.
(4) Select module 'EMM220-630'.(5)Select mode 'Energy'. (6)Enter the
Modbus address of the EMM.630 vb '1'. (7)Enter Modbus sub-address (
0=phase1, 1=phase2, 3=Phase3) '0'. (8) Enter an appropriate name
'Phase1 + IMPORT'. (9) 'GENERATE' and (9)a read the Modbus instruction
to the meter. (10) 'TEST RX' and read the meter's response with the
translation for 'VOLT','CURRENT','POWER',VA','PF'.(11)Set to 'PAY' and
press (9) 'GENERATE' and (9)a read the new 'meter reading' instruction to
the meter. (10)'TEST RX' and read the meter's response with the
translation for meter reading (12) 'SAVE' this setting. From now on we log
phase 1 (voltage, current, power, VA, PF) and the import meter readings
of an EMM.630. Press 'DAY' or 'MONTH' to read the graphs.
As example 2: logging phase 2 of a 3-phase meter
(1)'EDIT GROUP-CHANNEL' to create a second channel on the help screen
via (2)the blue 'ADD CHANNEL' button. After "ADD CHANNNEL" is the new
channel number and in brackets possibly an unused channel number. It is
preferable to choose this unused channel number by entering it in 'Group
Name / Channel Nr' and only then pressing '"ADD CHANNEL" (3)Click on
'CH1'. (4)Enter channel '0' and click (5)'LOAD' to load a copy of 'CH0'. (6)
Enter sub-address '1' (=Phase2) and change the name (7) to 'Phase2 +
EXPORT'. (8)'SAVE this configuration. (9) gives a sorting table of Modbus
addresses. Press again (9) to hide.
Result: You have now connected your first Modbus meter. Every minute
voltage, current, ... of phase 1 and phase 2 logged together with the
import (= consumption) and the export (= injection) meter reading with
which consumption graphs are then calculated.
From this 'Level3' you can create up to 64 energy channels (CH0.. CH63),
and these can be set as Modbus meters or as measurements from the
REL.44, RG.016,... More information can be found in the detailed manual.
Sort:
As long as the 'SORT CHANNELS' button on the left is turned on (red) you
can grab a channel and drag it to another place or in a different group.
Once done, confirm by clicking 'SAVE LAYOUT'.
Creating Groups
Click on 'EDIT GROUP-CHANNELS' and then 'ADD
GROUP' to create a new group.
Delete a group: select the group in the left page
and then click on 'EDIT GROUP-CHANNELS' and use the 'DELETE GROUP x'
button to delete the group.
Rename a group: select the group in the left sheet and then click on 'EDIT
GROUP-CHANNELS'. Enter a new name under 'Group name' and confirm it
with the green button 'RENAME GROUP x'.
3. General remarks:
 There are NO services associated with the purchase of a MEMo3
module. (NO: installation, configuration, backup, energy advice,...)
 Look online for the latest version of this leaflet, the detailed manual
MEMo3b manual or the MEMo3b video tutorial.
 It is important to work with the latest firmware in the web server
and the 2-Wire modules so upgrade! (see tutorial).
 MEMo3 is a 3rd generation data logger. The SD card of MEMo3 is
NOT compatible with the SD card of MEMo1 and MEMo2
 Remote access can be done via port-forward (see FAQ), or the
HTML-APP .
 A stable internet connection is required for proper operation .
 The MEMo configuration, and 2 year logs are stored on the internal
SD card. If something goes wrong with this SD card, all data will be
lost. The solution is a backup subscription with a cloud application
provider.
 After each submission, take a printout (at SETTINGS) of the
configuration of the modules and save it on PC.
 MEMo3 'MENU' key (6) (top right):keep pressing until the menu
appears on the display: FW CSS-JS / FW Memo / ERASE ALL/ EXIT
Each time you press the button (6) briefly, the menu 1 position continues.
If you have the desired menu (CSS-JS or FW MEMO): press ( 6) until this
menu becomes active. After loading the firmware, the WS.503 will
automatically reboot. (internet required!).
4. Technical data
General:
Power supply MeanWell: 230 Vac/50 Hz – protect with fuse 2P/6A
Web server power supply: 15 VDC/2 A, power consumption: 2 VA.
Internal SD card 4 GB
Operating conditions:
Operating temp. 10 °C to 50 °C; Storage temp.: -10 °C to 60 °C
Maximum humidity: 90%, no condensation. Highest point: 2000m
Physical Properties:
Housing: plastic, self-extinguishing according to . UL94-V0 Degree of
protection: IP20, EN 60529 Mounting on DIN rail, width 2 modules
Dimensions (H x W x L): 62mm x 90mm x 36mm, Weight: approx. 65
grams
Connections:
Power Supply: 15VDC/1A Stabilized
Bus: RS485 Modbus RTU(GAB+) at 9600.8N1 max 32 modules
RF LORA-FSK transceiver 868 MHz, 100mW
Ethernet connection with integrated transformers 10/100Mbit/sec
WiFi 2.4GHz 802.11 b/g/n , Tx power 19.5 dBm, Rx sensitivity -97dBm.
Labels:
RoHS: Non-toxic, cf. Guidelines WEEE/RoHS
CE: In accordance with EMC and low voltage directive: HBES – EN 50090-
2-2 and EN60950 – 1: 2006.
5. Installation instructions
Installation must be carried out by a certified installer and in accordance
with the regulations in force. The module must be built into a fireproof
fuse box. During installation, the following must be taken into account
(non-exhaustive list):
- the applicable laws, standards and regulations.
- the state of the art at the time of installation.
- This manual, which only mentions general provisions and should be read
in the context of each specific installation.
- the rules of good workmanship.
- the specified specs in this manual, otherwise there is a risk of damage to
the module.
This manual must be attached to the electrical installation file. On the 2-
Wire website you can always find the most recent manual of the product.
6. Support
Would you like to have the product repaired in case of a possible defect?
Please contact your supplier or order "inspection module" online.
7. Warranty provisions
The warranty period is two years from the date of delivery. The delivery
date is the invoice date of purchase of the product by the consumer. If no
invoice is available, the production date applies. The consumer is obliged
to inform Qonnex bvba in writing of the lack of conformity, and this at the
latest within two months after discovery. In the event of a lack of
conformity, the consumer is only entitled to a free repair or replacement
of the product, which is determined by Qonnex.
Qonnex is not responsible for a defect or damage resulting from incorrect
installation, improper or negligent use, incorrect operation,
transformation of the product, maintenance in violation of the
maintenance instructions or an external cause such as moisture damage
or damage due to overvoltage. The mandatory provisions in national
legislation on the sale of consumer goods and the protection of
consumers in countries where Qonnex sells directly or through
distributors, agents or permanent representatives take precedence over
the above provisions.
Qonnex bv B-9310 Aalst Belgium [email protected] www.2-wire.net

This manual suits for next models

1

Other 2-Wire Server manuals

2-Wire ML.016 MiLo User manual

2-Wire

2-Wire ML.016 MiLo User manual

2-Wire MEMO2 WS.502 User manual

2-Wire

2-Wire MEMO2 WS.502 User manual

Popular Server manuals by other brands

Bull NovaScale Blade 20 Series Site preparation guide

Bull

Bull NovaScale Blade 20 Series Site preparation guide

UTEK UT-600 Series product manual

UTEK

UTEK UT-600 Series product manual

Gateway E-9520T user guide

Gateway

Gateway E-9520T user guide

HPE ProLiant ML30 Generation9 Quickspecs

HPE

HPE ProLiant ML30 Generation9 Quickspecs

Siemens SINUMERIK 840D sl operating instructions

Siemens

Siemens SINUMERIK 840D sl operating instructions

Allnet ALL6800 user manual

Allnet

Allnet ALL6800 user manual

DSP TP400 PC Reference manual

DSP

DSP TP400 PC Reference manual

HP NetServer LH3 Installation road map

HP

HP NetServer LH3 Installation road map

Advantech FWA-6510 Installation

Advantech

Advantech FWA-6510 Installation

Avigilon VMA-AIA1-CG1 user guide

Avigilon

Avigilon VMA-AIA1-CG1 user guide

Compaq ProLiant DL580 specification

Compaq

Compaq ProLiant DL580 specification

Digital Equipment DIGITAL Server 7100 1200 Service maintenance manual

Digital Equipment

Digital Equipment DIGITAL Server 7100 1200 Service maintenance manual

Dell PowerEdge C6105 Getting started

Dell

Dell PowerEdge C6105 Getting started

Digital Watchdog Blackjack Tower DW-BJST51T Series quick start guide

Digital Watchdog

Digital Watchdog Blackjack Tower DW-BJST51T Series quick start guide

Gigabyte E283-Z91-AAD1 user manual

Gigabyte

Gigabyte E283-Z91-AAD1 user manual

Crystal RS373S17 user guide

Crystal

Crystal RS373S17 user guide

Thecus N4100PRO user manual

Thecus

Thecus N4100PRO user manual

Dell PowerEdge E31S Series owner's manual

Dell

Dell PowerEdge E31S Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.