3M 3M-30 Instruction Manual

Statement of use: The 3M-30 can be used with millivolt, 24VAC,
single and 2 stage conventional systems, gas/oil/electric heat, 1
stage heat pumps, 2 stage heat pumps, zoned hot water (2 or 3 wire),
zoned forced air, single and 2 stage cooling and hybrid systems.
Using a TOUCH SCREEN
Thermostat
Mode
FOLD
LINE
PG
2
PG
1
Day
Time of day
Touch here
to change
from 12 to 24hr
clock display.
Time
Slot
Current Room
Temperature
Chirp indicator
Target
Temperature
Menu
button
Program
button
Mode
Switch
Fan
Switch
Day
Time
of day
Time
Slot Current
Room Temperature
Touch
Screen
Thermostat
Mode
Target
Temperature
Basic Screens
The MODE SWITCH of the 3M-30 must be in the HEAT or the COOL position to access all
control functions. The 3M-30 Thermostat has 3 basic screens.
The HOME screen is displayed when unit is operating your system.
Touching the will always return you to this screen.
HOME screen
Operation
3M-30
Please take a moment to try out your
touch screen itself.
To select a function on the touch
screen, place your finger on the main
temp display and give a short firm push.
Try a "tap" of the finger or stylus. Your
input must last long enough for the
system to determine it is not an
accidental 'bump'.
Using the stylus is more comfortable
for some users. Again allow the system
enough time to recognize your inputs.
When you are comfortable with touch
inputs, proceed.

PG
3
PG
4
Displayed when the MENU button is pressed.
Displayed when the PROGRAM button is pressed.
MENU screen
PROGRAM screen
AM
Set Day
Touch this area to set
the day of the week.
Set Time
Touch this area to set
the time of day.
Left arrow goes back,
right arrow goes forward.
Calibration indicator
This shows if you
have altered the
calibration of your unit
Calibration control
Use this to calibrate
your LCD display
match to another
thermometer.
Set
o
C -
o
F
Touch this to set temperature
display.
Lock Program
Touch for 5 sec
to lock or unlock
Filter Timer set
Chirp set
Touch this to turn
the audible chirp
on or off.
Temperature Swing set
Return
HOME
Set Program Day
Touch this area to set the
day of the week you want
to program Target Temps for.
Set Time Slot
Touch this area to set
the Time Slot you
want to program.
Set Program Time
Touch this area to set the
time of day you want each
time period to start.
Left arrow goes back,
right arrow goes forward.
Copy
Touch this area to copy
current program to the
next day
Temp Up /
Temp Down arrows.
Touch these to raise
and lower each
Target Temp.
EPA
Touch and hold for
4 sec to return to
energy saving prog
Review
touch this area to auto cycle
through your program
Return HOME
When programming
is complete touch this
to run your program.
AM
EPA

This Thermostat comes preprogrammed with an energy saving
program. This program is recommended for energy efficiency.
We strongly recommend that you Auto-Run this program for one week,
and see if it works for you. If it does not fit your needs you can always input a custom
program.
• To Auto-Run the energy saving program, select HEAT or COOL with the mode switch.
The unit is now running the energy saving program.
• The clock is displayed on the left. The ambient temperature is displayed in the the
center of the LCD touch screen. The TIME SLOT icon indicates the TIME SLOT active
in the energy saving program.
• The programmed temperature is shown on the lower right. For program details refer to
the energy saving program chart below.
PG
6
All Days 70
o
F 62
o
F 70
o
F 62
o
F
MORN
6:00am
HEATDAY
8:00am
EVEN
6:00pm
NITE
10:00pm All Days 78
o
F 85
o
F 78
o
F 82
o
F
MORN
6:00am
COOL DAY
8:00am
EVEN
6:00pm
NITE
10:00pm
Configure
Press MENU to configure the thermostat (from HOME screen).
Set day of the week
-
Touch the
Day of the week
area to cycle through the days of
the week to select the current day.
Set time of day
-
Touch the
Time of Day
arrows to move the time selection
forward or backward until it displays the current time. Touch
and hold for faster setting.
Set
o
C -
o
F
display
Touch the
o
F
and it will toggle to
o
C.
Set audible chirp
-
Touch the the musical note icon to select the chirp or no chirp.
EPA - Touch and hold for 4 sec to return to Energy Saving program
Return HOME by touching the home icon.
PG
5
ForwardBackward
The Mode Switch must be in
HEAT
or
COOL
mode to configure.
EPA
EPA
Auto-run

Program
Program cont.
NOTE:
60 Second Rule-During
programming, if a button is not pushed in 60
seconds, the unit will return to the home screen. Everything you have changed
while programming will automatically be saved.
PG
7
PG
8
Select HEAT with the HEAT/Cool MODE switch.
Press PROGRAM to go to the programming
screen.
Select the day you want to program
-
Touch the
Day of the week
area to cycle through the
days of the week to select the desired day.
Select the time slot you want to program
-
Touch the
Time slot
area to cycle through the 4 time
slots, until it displays the desired time slot.
Select the time of day
-
Touch the
Time of Day
arrows to move the time selection
forward or backward until it displays the desired time.
Touch and hold for faster time set.
ForwardBackward
Select the desired temperature -
Touch the UP temp / Down temp arrows.
Repeat the above procedures for each day of the week and
each time slot of the day as desired.
To REVIEW your program touch REVIEW.Each time slot for each day
or set of identical days, will be displayed every 3 seconds.
Return HOME by touching the home icon.
To COPY the program from the current day to another day -
Touch COPY on the program screen. The current day will remain solid,
the destination day will flash.
Touch the day area to advance the day and select a copy destination.
Touch COPY again to copy all settings to the destination day.
To program for cooling -
Select COOL with the Heat/Cool MODE switch and repeat the
above procedure.

Manual cont.
Manual
Temporary OVERRIDE -
• At the Manual override screen, Touch the Temp Up / Temp Down arrows to
select your desired temporary Target Temperature.
•Touch HOME to return to operation.
The OVERRIDE icon will go on indicating you have modified the Target Temp
for the current Time Slot only (see PG7-Time Slot).
The 3M-30 has 3 manual override commands. These are accessed by
touching the Current Temp Display at the HOME screen (center of screen).
PG
9
PG
10
Target Temperature
HOLD
Touch this area to set
a comfortable target
temp for the system
to hold until you return
and remove HOLD.
Return HOME
Temp Up / Temp Down arrows
Touch these to raise and lower
the manual override Target Temp.
Manual Override indicator
Shows TEMPORARYwhen
you have modified the Target.
MANUAL override screen
HOLD -
• At the Manual override screen, Touch HOLD to initiate a hold temperature.
•Touch the Temp Up / Temp Down arrows to select your hold temperature.
•Touch HOME to return to operation.
The HOLD ON icon will flash indicating you have changed the Target Temp.
The system will HOLD this temperature until you return to this screen
and de-select HOLD, by touching the HOLD icon again.
The Mode Switch must be in
HEAT
or
COOL
mode to override.
TEMPORARY

Special Features
Spec. Featr. cont.
Swing
Swing setting determines the temperature
difference in degrees from ON to OFF that the
thermostat will command the HVAC system to run.
With the MODE switch in HEATor COOL, press the MENU button.
Touch the SWING icon and the current setting of temp swing is shown on the
display (default at .5o).
To change the swing factor, touch the left or right arrows.
The furnace will cycle more at the lower numbers as it tries to maintain your temp.
Filter
The 3M-30 has a feature that keeps track of actual furnace run time
and reminds you to periodically replace your system's air filter.
Press
MENU
(from HOME screen)
and touch
FILTER
icon.
This will display your accumulated filter run time in weeks.
To zero the filter timer for a new filter, touch the accumulated time display.
To input a new filter life time, touch the
FILTER
icon for 3 seconds.
Input the lifetime in weeks for your new filter.
To leave the filter display, touch
HOME.
Lock
Allows you to to prevent any changes in custom settings.
To Lock Level1, touch the LOCK icon on the MENU screen for 2 sec.
Level1 allows temporary target adjustments but no program changes
To Lock Level2, touch LOCK icon for 2 sec. Level2 allows no changes.
To unlock, Touch the locked icon for 2 sec.
Low Battery
When the batteries are low, the battery icon will flash.
The two AAA Batteries in the unit need to be replaced. In some
installations your heater system will stop functioning when the thermostat loses
power. Replace batteries as soon as you see this warning. The thermostat
programs will remain for 60 seconds while the batteries are changed.
Do not take longer than 30 sec to change the batteries in your unit or you will
lose all custom settings and all programming. Only the energy saving program will
remain. Once the batteries are replaced, the system will return to normal in 2
seconds.
12/24 hour
The thermostat can display time in 12 or 24 hour formats.
At the HOME screen touch the time to toggle from 12 to 24 hr display.
PG
11
PG
12
WKS

P
14
P
13
If you have a heat pump with
Auxiliary heat, the new sequential
staging will give you faster recovery
from set backs. The thermostat can
be configured for Electric aux or
gas/oil aux heat (see installation). If
the heat pump cannot maintain your
desired room temperature, the new
system allows theAux heat to help
maintain your heat all the way to
your desired room temperature.
When using a heat pump withAuxiliary heat, if the heat pump is not working, you can
move the large jumper 3 from B (lower) HEATPUMP position to theA(upper) AUX ONLY
position (reset is not necessary). The Auxiliary heat will then be your only source of heat.
When the heat pump is again operational, be sure to change jumper 3 back to the B
position as theAuxiliary heat is more expensive than the heat pump.
Heat Pump Features
This thermostat can be used with all millivolt and 24VAC heating and cooling systems.
It cannot be used with line voltage systems. This thermostat is digital and your desired
heat or cool temperatures can be easily be set on the large touch screen with the
UP/DOWN arrows. A minimum 4 minute off time protects heating and cooling systems
from damage.
This thermostat uses a new
technique called sequential
staging for more comfort with
faster reaction to requested
temperature changes.
3M-30 Features
HEATPUMP/
AUX ONLY
Jumper
AB

1002-008
NOTE: Your thermostat comes from the factory calibrated to + or -
1
o
F actual temperature. It is an accurate instrument. If you want your thermostat
to display the same temperature as another thermometer in your home, you can
adjust it. Maximum calibration is +/-6
o
.
To change the calibration:
With the switch MODE in
HEAT or COOL.
Press the
MENU
button.
Press the Temp Up/Temp
Down arrows to adjust the
temperature reading.
CALIBRATE DISPLAY ON
will appear.
Press
HOME
to save the
new setting.
Calibration
AM
Customer Support: 888-607-5824 or
Visit our website www.radiothermostat.com/filtrete
Printed in China
Other manuals for 3M-30
2
Table of contents
Other 3M Thermostat manuals
Popular Thermostat manuals by other brands

Riello
Riello BeSMART installer and user manual

Honeywell
Honeywell T8602D installation instructions

Lux Products
Lux Products PH521 Installation and operating instructions

Honeywell Home
Honeywell Home T4 Pro Product information

Amber
Amber Amber-Pro Complete guide

GE
GE RAK148P1 Owner's Manual & Installation Instructions