Aaronia UBBV Series User manual

Pre-Amplifier UBBV-Series
Manual
Rev 1.2 EN
18.03.2013
M a d e i n G e r m a n y

HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com
2
Please read this manual
carefully before starting up
the preamplifier. The manual gives you
useful instructions how to operate the
unit correctly.

Section Page
1.0 Safety instructions 4
2.0 Scope of delivery 5
3.0 SMA connections 6
4.0 Operating at SPECTRA 7
5.0 Operating at external devices 8
6.0 Operating at HyperLOG X antennas 9
7.0 Operating at PBS ProbeSet 10
8.0 Activating the UBBV preamplifier 11
9.0 Power connection 12
10.0 Reading out the calibration data 13
11.0 Warranty 14
12.0 Developer- et, User Forum and more! 15
13.0 Frequency charts for spectrum analyzers & antennas 16
Content
HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com 3

Don’t bring ever the UBBV preamplifier in contact with water. Don’t use it if it is
raining. The sensitive electronic system could otherwise be damaged.
Because of the high sensivity the electonic system of the UBBV preamplifier is
very shock- and impact-sensitive. Always treat your preamplifier carefully. Don’t
let the UBBV falling down, as it could be damaged.
We recommend to use always our transport case for storage and trans-
port.
The UBBV preamplifier is maintenance-free. Please clean it therefore only out-
side with enclosed cleaning brush or a damp cloth. Don’t use cleaning supplies.
ATTE TIO :
Please screw antennas and adapter always in a non-violent way with the
UBBV preamplifier. Please use for loosening or screwing of SMA-
connections O LY the enclosed SMA tool, which offers a over-tightening
protection.
1.0 Safety instructions
HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com 4
WAR I G:
Please avoid to overstress the UBBV-preamplifier by inputting to much
power as otherwise the UBBV preamplifier could be damaged. The maxi-
mum peak-power, which you can put at the input of the preamplifier, is
20dBm.
The output power of the UBBV-preamplifier could be up to 20dBm.
Please ensure that your connected measurement unit will not be dama-
ged due to this power.

Please check before initial operation the completeness of delivery. Please
reclaim missing parts immediately at Aaronia or at your Aaronia dealer.
Included in delivery are the following items:
(1) Cleaning brush
(2) SMA adapter for operation with external devices (optional)
(3) UBBV preamplifier with integrated battery
(4) SMA to adapter for operation with external devices (optional)
(5) SMA tool
(6) International battery charger (power supply) with four adapters
(7) Two mounting brackets for SPECTRAN measuring unit
(8) Mini USB cable for reading out the calibration data
2
4
67
5
3
2.0 Scope of delivery
HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com
5
8
1

There are different versions of the UBBV-preamplifier available, which only vary
in the SMA connections. At all versions the position of the input and output are
identical:
The input of the UBBV-preamplifier is always located at the site which is bent
outwards.
The output of the UBBV-preamplifier is always located at the site which is bent
inwards.
Version #1: Input: Female with SMA jack; Output: Male with SMA plug and cap
nut.
This version can for instance be mounted directly at the front part of our SPEC-
TRAN measurement devices. Please see the instruction in section 4.0
„Operating at SPECTRAN”.
By using our optional SMA adapter the version #1 can be also inserted between
two SMA cables (see instruction at section 5.0 „Operating at external devices“).
Here the SMA adapter is screwed at the male SMA plug with cap nut. You will
receive then a further female SMA plug.
Version #2: Input: Male with SMA jack and cap nut; Output: Female with SMA
jack.
This version is fixed screwed with our Hyper OG X antenna series and is spe-
cially suited for the respective antenna (see instruction at section 6.0
„Operating at Hyper OG X antennas“) and therefore cannot be used for other
purposes!
3.0 SMA connections
HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com 6
Version #2
Version #1
Input
Output

4.0 Operating at SPECTRAN
HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com
7
Please put the enclosed mounting brackets
consistently and in a non-violent way in the
intended slots of the SPECTRAN until it
locks firmly.
Please put then the protruding mounting
brackets of the SPECTRAN consistently and
in a non-violent way in the intented slots of
the UBBV-preamplifier until the SMA jack of
the SPECTRAN and the SMA plug of the
UBBV-preamplifier lock in place together.
Screw then with enclosed SMA tool the SMA
plug of the preamplifier with the SMA jack of
the SPECTRAN. Avoid tilting the UBBV-pre-
amplifier in order to avoid damaging the sen-
sitive SMA jacks. Screwing should be carried
out very smooth. Refrain from using force!
As soon as you feel any resistance, please
retighten the screw connection. Do this also
in a non-violent way! The SMA tool offers a
over-tightening protection and starts to slip
down if too strong forces are affecting.
The UBBV-preamplifier should be now firmly
fixed with the SPECTRAN without wobbling.
Please leave always, if possible, the both
devices connected as every removal and
re-assembly could wear out the SMA
jacks and could cause damages!
ATTE TIO : If you don’t use the SPEC-
TRAN together with our CS or MCS soft-
ware, you have to activate the UBBV-pream-
plifier in the menu “RefOff” (by choosing the
headword “UBBV12”) in order that the
SPECTRAN is calibrated correctly!

5.0 Operating at external devices
HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com
8
By using our SMA adapter you can
equip the male output of version#1 of
the UBBV-preamplifier with a female
SMA jack.
That way the in- and output of our
UBBV-preamplifier can be connected
with one of our optional 1m, 5m or 10m
SMA cables and you can plug in any
spectrum analyzer, oscilloscope, anten-
na etc..
If your measurement unit or antenna is
equipped with a N-input, you will need
our optional SMA to N adapter as well.

6.0 Operating at Hyper OG X antennas
HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com
9
Version #2 (Input: Male with SMA jack and cap nut; Output: Female with SMA
jack) is fixed screwed with our Hyper OG X antenna series and is specially sui-
ted for the respective antenna and therefore cannot be used for other pur-
poses!
Nevertheless the preamplifier can be
mounted and removed as follows:
Please put the protruding mounting
brackets of the Hyper OG antenna con-
sistently and in a non-violent way in the
intented slots of the UBBV-preamplifier
until the SMA jack of the Hyper OG
antenna and the SMA plug of the UBBV-
preamplifier lock in place together.
Screw then with enclosed SMA tool the
SMA plug of the preamplifier with the
SMA jack of the Hyper OG antenna.
Avoid tilting the UBBV-preamplifier in
order to avoid damaging the sensitive
SMA jacks. Screwing should be carried
out very smooth. Refain from using
force! As soon as you feel any resi-
stance, please retighten the screw
connection. Do this also in a non-violent
way! The SMA-tool offers a over-tigh-
tening protection and starts to slip down
if too strong forces are affecting. The
UBBV-preamplifier should be now firmly
fixed with the Hyper OG antenna with-
out wobbling.
ATTE TIO : Please leave always the
UBBV-preamplifier connected to the
antenna (as delivered) as every remo-
val and re-assembly could wear out the SMS jacks and could cause dama-
ges!

7.0 Operating at PBS Probe Set
HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com
10
Operating at SPECTRA :
If you are using our SPECTRAN, you
can connect the UBBV-preamplifier at
the SPECTRAN as described in section
„4.0 Operating at SPECTRAN“. After this
please put the SMA cable of the PBS
Probe Set directly at the installed UBBV-
preamplifier.
Operating at external devices:
If you are using our UBBV-preamplifier
together with an external device, you
have to equip the UBBV-preamplifier
with our SMA adapter according to
instruction „5.0 Operating at external
devices“.
Thereafter you can connect directly the
SMA cable of the PBS Probe Set to the
SMA jack.

The UBBV-preamplifier can be turned on
and off at the switch on the back side of
the preamplifier. With the integrated
iPo-battery the preamplifier has a run-
time of approx. 3-4 hours.
When starting up the preamplifier it
might be necessary to charge the bat-
tery first. Please pay attention to the
instruction in section 9.0.
If the UBBV-preamplifier is switched on,
a red control ED on the upper side of
the preamplifier lights up.
8.0 Activating the UBBV preamplifier
HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com 11

Battery operation:
The UBBV-preamplifier includes a iPo
power battery, which is already installed
in the preamplifier. The run-time of the
battery is about 3-4 hours.
The battery can be charged by enclosed
battery charger. For this please connect
the battery charger to the mains supply
and the jack plug of the battery charger
to the power connection of the UBBV-
preamplifier. The battery will be loaded
then. The control ED next to the power
connection changes its colour after
some seconds from green to red. After the battery is loaded completely, the con-
trol ED lights up green again.
A complete charging takes about 90 minutes.
Long-term operation with external power supply:
As described before, the external power connection is used for charging the
internal battery. Additionally you can use it to operate the UBBV-preamplifier
independently from the internal battery (long-term operation).
For this the battery charger will be connected to the mains supply and the jack
plug of the battery charger will be plugged to the power connection of the UBBV-
preamplifier. The control ED next to the power connection should light up then
green. With an empty battery the control ED lights up red. As soon as the bat-
tery is charged completely, the control ED lights up green again. The UBBV-
preamplifier operates independantly of the state of charge.
You can connect also other DC sources with 12V. As connecting plug a 3,5mm
jack plug has to be used. The connecting plug has to be poled as follows: The
inner pole is “+” and the outer pole is “-”. With our optional power adapter for
the cigarette lighter (see our pricelist) you can charge or operate the UBBV-pre-
amplifier also in the car.
All cables/equipment, which you want to connect to the external power supp-
ly of the preamplifier, have to deliver DC of 12V. Please use a standard jack
plug with a diameter of 3,5mm (inner pole P US, outer pole MINUS).
9.0 Power connection
HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com 12

Every Aaronia UBBV-preamplifier is already individually calibrated in our factory.
The corresponding calibration data are stored at an EEprom in the preamplifier.
These data you can read out at any time via USB-interface of the preamplifier.
Reading out the calibration date (still in preparation!):
Please connect for this the enclosed USB 2.0 cable (USB A at Mini USB B 5pol)
with your computer and switch on the
UBBV-preamplifier (power ED lights up
red).
Reading out the data can be done by
using our free MCS analysis software
(for Windows, MAC-OS or inux), which
you can find at enclosed CD or at our
forum website http://spectran-develo-
per.net.
The read-out data you can export as a
textfile and e. g. print out or put and illu-
strate in a spreadsheet.
You can also use the typical calibration data of the UBBV-preamplifier, but there
might be some small variations within the series. Therefore we recommend to
use always for an accurate measurement the internal calibration data of the
UBBV-preamplifier. That way you can better compensate the frequency depen-
dant amplification of each UBBV-preamplifier.
10.0 Reading out the calibration data
HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com
13

11.0 Warranty
HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com
14
The Aaronia warranty
Guaranteed upgrade service to „higher-value models“.
Your can exchange your UBBV-preamplifier, just by paying the differential amo-
unt, for a higher-value model of the same series (e. g. UBBV1 to UBBV2) at
any time.
Guaranteed exchange when launching new models.
Once we are launching new devices, you can at any time exchange your UBBV-
preamplifier, just by paying the differential amount, for a new version of your
choice.
10 years warranty on all models.
We offer 10 years warranty for all our UBBV-preamplifiers (battery excluded).
We promptly exchange defective units in a non-bureaucratic way.

HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com 15
12.0 Developer-Net, User Forum and more!
Please visit our support website:
http://spectran-developer.net
Here you can find e.g..:
- Free Firmware updates
- Free PC Analyzer-Software (for MAC OS, inux and Windows)
- P-CODE Programme, examples and SPECTRA TU I G
-User Forum incl. FAQ
- ews about latest Aaronia products

HW UBBV / © 2010-2013 Aaronia AG, D-54597 Euscheid, www.aaronia.com
16
13.0 Frequency charts for analyzers & antennas
Frequency charts for SPECTRA spectrum analyzers
Frequency charts for HyperLOG and BicoLOG antennas and probes
Table of contents