ACME TrussHub U User manual

CA-AN04T

1A
CONTENTS
1. Safety Instructions..............................................................................................2
2. Features...................................................................................................................4
3. Overview..................................................................................................................5
3.1 Front/ Rear View..........................................................................................5
4. Operation Guide.....................................................................................................6
4.1 Startup View..................................................................................................6
4.2 Main menu..................................................................................................7
4.2.1 Rename Device...................................................................................7
4.2.2 Set IP Address.....................................................................................8
4.2.3 Set Netmask.........................................................................................8
4.2.4 Set DMX port .......................................................................................8
4.2.5 Set ID NO...........................................................................................12
4.2.6 Set LCD Backlight.............................................................................12
4.2.7 User Preset........................................................................................12
4.2.8 Version................................................................................................14
5.Application Diagram.............................................................................................15

2A
1. Safety Instructions
WARNING
Please keep this User Manual for future consultation. If you sell the fixture to another user, be
sure that they also receive this instruction booklet.
Please unpack and check carefully there is no transportation damage before using the fixture.
Please disconnect main power before servicing and maintenance.
The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent
surfaces. Be sure that no ventilation slots are blocked.
The ambient temperature is Ta: 0℃-40℃. DO NOT operate it where above or below the range
of temperature.
DO NOT connect the device to any dimmer pack.
The housing must be replaced if they are visibly damaged.
Unit surface temperature may reach up to 85℃. Don’t touch the housing bare-hand during its
operation. Turn off the power and allow about 15 minutes for the unit to cool down before
replacing or serving.
There are no user serviceable parts inside the fixture. Do not open the housing or attempt any
repairs by yourself. In the unlikely event your fixture may require service, please contact your
nearest dealer.
In the event of serious operating problem, stop using the fixture immediately. Never try to
repair the fixture by yourself. Repairs carried out by unskilled people can lead to damage or
Please read the instruction carefully which includes important
information about the installation, usage and maintenance.

3A
malfunction. Please contact the nearest authorized technical assistance center. Always use the
same type spare parts.
Installation:
The unit is fully operational in three different mounting positions, hanging upside-down from a
ceiling or set on a flat level surface. To avoid internal damage to the unit, never mount the unit
on its side as illustrated above. Be sure this fixture is kept at least 0.5m away from any
flammable materials (decoration etc.). Always use and install the supplied safety cable as a
safety measure to prevent accidental damage and/or injury in the event the clamp fails.

4A
2. Features
RJ45 Ethernet (LAN) connector, 10/100M self-adaption, support TCP/IP
protocol
Support standard DMX/RDM and ArtNet protocol
Support ArtNet←→DMX/RDM signal bilateral conversion
DMX input/output can be set as able/disabled
Each DMX output can be set as single, zero, HTP, LTP,RDM mode
Each DMX input can be set as normal / backup mode
Can be acted as DMX/RDM splitter
IP address can be set manually
OLED display indicates each DMX port status
Online updates software
4 DMX output. All the input /output with optoelectronic isolation
Input is electrically isolated from output and output to withstand voltage:
>2000V
NOTE: Some basic knowledge of DMX is required to fully utilize this unit.

5A
3. Overview
3.1 Front/ Rear View
1. Button:
MENU
To enter into move backward or
leave the menu
UP
To go backward to move up in the
menu
DOWN
To go to move down in the menu
ENTER
To perform the desired functions
2. OLED Display:
Display the present status and the available option.
3. LED indicator:
To show the power/signal status of the unit.
4. Ethernet RJ45 connector:
Connect with network cable
5. D MX port 1-4:
Connect with network cable.
6. Power In:
To connect to the mains supply

6A
4. Operation Guide
4.1 Startup View
There are 5 different status (as pictures show) you can check when you power
on your unit. You can switchover them by pressing the UP and DOWN. The
first four options can be changed in the main menu.
In the port status, A/B refers to the DMX port Ethernet IN/ Ethernet Thru;
1/2/3/4 refers to the DMX port 1/2/3/4; In the first line,√/x means the port
status is activity/inactive; “-” means the current port status is disabled. In the
second line, “-” means the current port status is input signal.
When the screen is in the fifth state, Hold the ENTER key for 3 seconds and
enter the MAC address modification interface,You can set their values by
pressing the UP and DOWN, confirm you change by press the ENTER.

7A
4.2 Main menu
4.2.1 Rename Device
Enter into the main menu by press MENU, then pressing the UP and DOWN
to choose the Rename Device option and then press the ENTER to confirm
your selection. Now you can rename the device by pressing UP and DOWN
now. Confirm you change and move to next option by press the MENU.

8A
4.2.2 Set IP Address
Enter into the main menu by press MENU, then pressing the UP and DOWN
to choose the Set IP Address option and then press the ENTER to confirm
your selection. Now you can set IP address by pressing UP and DOWN now.
Confirm you change by press the ENTER.
Please note: Each of the IP address should be unique.
4.2.3 Set Netmask
Enter into the main menu by press MENU, then pressing the UP and DOWN
to choose the Netmaskoption and then press the ENTER to confirm your
selection. Now you can set Netmaskby pressing UP and DOWN now.
Confirm you change by press the ENTER.
4.2.4 Set DMX port
Enter into the main menu by press MENU, then pressing the UP and DOWN to

9A
choose the set DMX port option and then press the ENTER to confirm your
selection. Then you can set the parameter of the each port by pressing UP
/DOWN and ENTER now.
1) 1-4 DMX Input
You can enter to any of the DMX port 1-4 and set as below:
1, Port Status, DMX port status can be set as IN / OUT/ DIS;
2, As the DMX port set as Input status, then the Mode only can be set as
normal or backup.
3, Framerte/fs
4,NET
5,Principal
6,Secondary
7, Resend
8,Display Mode Dec
Normal mode means it will send the data received from DMX IN port to the
universal of network regardless if there is any data in the universal of the
network.
Backup mode refers that when there is any data on the universal of
network, the CA-AN04T won’t send any data to universal of network. Only
when the universal of network is no any data, then the CA-AN04T will
receive the data from DMX IN port and send it to the universal of network
simultaneously.
2) 1-4 DMX output

10A
Any of the port 1-4 also can be set as Output or Disabled status. Upon the port
has been set as Output status, there are LTP, HTP, Zero, Single and RDM
these 5 modes can be selected.
Zero means the port output should be “0’;
Single means this port will only output one universal.
LTP means this port will output the latter one between the universal of principle
and secondly. The unit will compare the two universal and resend the later one
to the network.
Please note that in the LTP mode, you should ensure the Resend option
is not at the status of Disabled. Or it won’t resend the data to the network.
HTP means the port will output the one with higher value between the
universal of principle and secondly. The unit will compare the two universal and
resend the higher data to the network. They can be set within the range of
0.0-F.F./001-255. (These two formats can be change through Display Mode)

11A
Please note that in the HTP mode, you should ensure the Resend option
is not at the status of Disabled. Or it won’t resend the data to the network.
RDM means the port output can support Remote Device Manager.
3) 1-3 DMX port disabled
Any of the port 1-4 can be set as Disabled status. Upon the port has been set
as Disabled status, the DMX port will be disabled, it cannot send or receive any
data from now on.
Please note that the Framerte/fs only available for Output status; The Secondly and
Resend option only available for the HTP/LTP mode under the status of Output.

12A
4.2.5 Set ID NO.
Enter into the main menu by press MENU button, pressing UP and DOWN to
choose the Set ID NO. option, then press the ENTER to confirm your selection.
You can set the ID No. for the unit from 000 to 255. The ID is only used to
recognize each of the unit easily.
4.2.6 Set LCD Backlight
Enter into the main menu by press MENU button, then pressing the UP and
DOWN to choose the Set LCD Backlight option and then press the ENTER to
confirm your selection. You can choose its status as ON/OFF. ON means the
LCD backlight will turn on all the time. OFF means the LCD backlight will turn
off automatically after idle 30 seconds.
4.2.7 User Preset
Enter into the main menu by press MENU button, then pressing the UP and
DOWN to choose the User Preset option and then press the ENTER to
confirm your selection. This setting help you easily use the application avoid
complicated setup procedure. You can simply choose you desired mode by

13A
pressing UP and DOWN, and confirm your choose by pressing ENTER..
1) 4 x Input: Make the 4 DMX port as Input status.
2) DMX Split 1-3: This setting will help you make the unit as one splitter
which with one DMX input to 3 DMX output. Please note that the LED
indicator of the DMX Output port will light up in green.
3) ArtNet Clone: Direct through mode, the preset is used to replicate a
standard ArtNet signal from 2 (1-2) Input ports to 2(3-4) output ports.
4) Isolated Mode:It will isolate the DMX input and output. The DMX input
wouldn’t output the DMX signal to the DMX out port. The range of DMX

14A
port 1-4 is 0.0~0.7.They will receive the signal from the network
individually.
5) Factory Setting: All of the setting including the device name, device ID as
well as device IP will be restored to the original status.
4.2.8 Version
You can check the version number from this option.

15A
5. Application Diagram
Please Note that the unit cannot be circular connected, or it will cause
cyber storm to affect the performance of system.

16A
Technical Specification
Voltage:AC100-240V, 50/60Hz
Power consumption:5W
Dimension/ Weight:
174x148x144mm, 1.9Kg
6.9"x5.8"x5.7"in, 4.2lbs

17A
It can be installed in truss of different sizes(Φ40MM/50MM/60MM)

18A

19A
Declaration of Conformity
We declare that our products (lighting equipments) comply with the
following specification and bears CE mark in accordance with the
provision of the Electromagnetic Compatibility (EMC) Directive
89/336/EEC.
EN55103-1: 2009+A1:2012; EN55103-2: 2009;
EN61000-3-2: 2014; EN61000-3-3: 2013.
&
Harmonized Standard
EN 60598-1:2015; EN 60598-2-17:1989 + A2:1991;
EN 62471:2008; EN 62493: 2010
Safety of household and similar electrical appliances
Part 1: General requirements
Innovation, Quality, Performance
This manual suits for next models
1
Table of contents
Other ACME Amplifier manuals