1IASBOX - TECHNICAL MANUAL
FOREWORD
FOR THE INSTALLER:
Please follow carefully the specifications relative to electric and security systems realization further to the manufactu-
rer’s prescriptions indicated in the manual provided.
Provide the user the necessary indication for use and system’s limitations, specifying that there exist precise specifi-
cations and different safety performances levels that should be proportioned to the user needs. Have the user view
the directions indicated in this document.
FOR THE USER:
Periodically check carefully the system functionality making sure all enabling and disabling operations were made cor-
rectly.
Have skilled personnel make the periodic system’s maintenance. Contact the installer to verify correct system opera-
tion in case its conditions have changed (e.g.: variations in the areas to protect due to extension, change of the access
modes, etc…)
......................................................
This device has been projected, assembled and tested with the maximum care, adopting control procedures in accor-
dance with the laws in force. The full correspondence to the functional characteristics is given exclusively when it is
used for the purpose it was projected for, which is as follows:
1 Input Analogue Addressable Module
Any use other than the one mentioned above has not been forecasted and therefore it is not possible to guarantee its
correct operativeness.
The manufacturing process is carefully controlled in order to prevent defaults and bad functioning. Nevertheless, an
extremely low percentage of the components used is subjected to faults just as any other electronic or mechanic pro-
duct. As this item is meant to protect both property and people, we invite the user to proportion the level of protection
that the system offers to the actual risk (also taking into account the possibility that the system was operated in a de-
graded manner because of faults and the like), as well reminding that there are precise laws for the design and as-
semblage of the systems destinated to these kind of applications.
The system’s operator is hereby advised to see regularly to the periodic maintenance of the system, at least
in accordance with the provisions of current legislation, as well as to carry out checks on the correct running
of said system on as regular a basis as the risk involved requires, with particular reference to the control unit,
sensors, sounders, dialler(s) and any other device connected. The user must let the installer know how well
the system seems to be operating, based on the results of periodic checks, without delay.
Design, installation and servicing of systems which include this product, should be made by skilled staff with the ne-
cessary knowledge to operate in safe conditions in order to prevent accidents. These systems’ installation must be
made in accordance with the laws in force. Some equipment’s inner parts are connected to electric main and therefore
electrocution may occur if servicing was made before switching off the main and emergency power. Some products
incorporate rechargeable or non rechargeable batteries as emergency power supply. Their wrong connection may da-
mage the product, properties and the operator’s safety (burst and fire).
YOUR DEALER:
www.acornfiresecurity.com
www.acornfiresecurity.com

TECHNICAL MANUAL - 1IASBOX
1. GENERAL
1IASBOX module has been designed for advanced fire detection systems managed by FX/50, FX/20 and FX/10
control panels (and other compatible) equipped with loop operating with AS protocol; it is equipped with 1 balanced/
non-balanced programmable input.
The module can be connected to devices or traditional fire detectors with NO relay output contacts (free from po-
tential).
The digital transmission of the alarm event is triggered when the module receives an alarm, that is, when the de-
tector contact closes. The alarm condition is kept until the contacts go back to NO status. When the contact closes,
a 18KOhm resistance will be connected in parallel to the 47KOhm line balancing resistance; open line or short-cir-
cuited status will be detected as fault condition by the module. The alarm condition can be signalled next to the de-
tector by connecting a low-consumption LED diode (as specified below) to the terminal output. Module input can be
set to "non-balanced" by using the dipswitch no. 1 (OFF). In this case, the end-of-line resistor is not required and the
detector contact has to be directly wired to the terminals. When the detector contact closes, the module will receive
the alarm event, but it will no longer be able to detect (and signal) the fault event (but only alarm event).
1IASBOX is equipped with a two-colour LED to indicate: input fault condition (blinking red), alarm status (steady
red), and interrogation status (blinking green, the unit interrogates the module). Use dipswitch no. 2 (OFF) to disable
input fault conditions and alarm status signalling (red light).
1IASBOX module communicates with the fire panel over serial loop and in case of correct communication, the
two-colour LED will blink green. The loop is connected to the AS protocol via SIG and -S terminals. This connection
does not require an external power supply unit.
1IASBOX module is supplied with a reduced-dimension plastic housing and is also suitable to be installed on 503-
type flush-mount boxes.
2. TECHNICAL SPECIFICATIONS
Model: 1IASBOX
Protection class: IP4X
Power supply: DC24V
Operating voltage: DC20,5 to 27,5V
Power consumption: 3,3 mA idle mode, 4,5 mA max alarm mode.
Connections: terminals for inputs, signals communications and serial loop connection.
LED indicators: (on board) two-colour LED indicator for alarm and fault events (selectable),
and communication status.
Controls: rotary dip switches to set ID address.
6-pin dip switch to set operating functions.
Operating temperature: -10 to +50°C; 93% r.h.
Weight: 58 g.
Dimensions: W 91,6 x H 54,7 x D 20 mm.
Distance
between centers: W 84 mm.
Parts supplied: technical manual, balancing resistors (1 x 18KOhm, 1 x 47KOhm).
3. PRODUCT COMPLIANCE
1IASBOX module is compliant with EMC 89/336/EEC directive: tests have been carried out according to
EN50130-4 +A1 + A2 on immunity and EN 61000-6-3 on electromagnetic compatibility.
As to electric safety, 1IASBOX module is compliant with LVD 73/23/EEC directive on low voltage safety:
tests have been carried out according to EN 60950-1 standard.
1IASBOX module is also compliant with EN54-18 standard.
CPD certification n° 0051 - CPD - 0276.
www.acornfiresecurity.com
www.acornfiresecurity.com

TECHNICAL MANUAL - 1IASBOX
5. FLUSH-MOUNT DIAGRAM
6. ID ADDRESS SETUP
The setup procedure of 1IASBOX module ID address is very easy: it is equipped with three rotary dip
switches corresponding, respectively, to hundreds (x100), tens (x10), and units (x1) of the code to set.
Please consider that code setup is fundamental for the correct identification of the module from the control
panel; the module will be detected as one input module.
Example:
1IASBOX module with ID code 035:
IMPORTANT: do not use the ID addresses 0 (zero) and 255.
503 FLUSH-MOUNT BOX
503 FLUSH-MOUNT
BOX COVER
www.acornfiresecurity.com
www.acornfiresecurity.com

1IASBOX - TECHNICAL MANUAL
7. FUNCTIONS SETUP
To setup module functions, use the dipswitch indicated in “OVERVIEW AND WIRING DIAGRAM” on
page 4.
Functions are listed in the following table:
8. DISPOSAL INSTRUCTIONS
Dispose of analogue addressable module 1IASBOX in compliance with current city regulations and by lea-
ving the device in a dumping ground that is authorized for the disposal of electronic products.
If required, please contact the appropriate city office for additional information.
The materials used for this product are very harmful and polluting if dispersed in the environment.
Dip Switch Position Function
1ON Balanced input
OFF Non-balanced input
2ON Enables lighting ON (red light) of INPUT 1 LED
OFF Disables lighting ON (red light) of INPUT1 LED
3ON Not used.
4ON Not used.
5ON Not used.
6ON Not used.
www.acornfiresecurity.com
www.acornfiresecurity.com

TECHNICAL MANUAL - 1IASBOX
9. CONTENTS
1. GENERAL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3
2. TECHNICAL SPECIFICATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3
3. PRODUCT COMPLIANCE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3
4. OVERVIEW AND WIRING DIAGRAM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4
5. FLUSH-MOUNT DIAGRAM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5
6. ID ADDRESS SETUP - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5
7. FUNCTIONS SETUP - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
8. DISPOSAL INSTRUCTIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
9. CONTENTS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7
www.acornfiresecurity.com
www.acornfiresecurity.com
This manual suits for next models
1
Table of contents
Popular I/O System manuals by other brands

National Instruments
National Instruments NI 9234E Operating instructions and specifications

Rockwell Automation
Rockwell Automation Allen-Bradley Micro800 Wiring diagrams

IFM
IFM Ecomat 100 CR2011 Device manual

Nittan
Nittan NAM-AS3 Installation & technical manual

ICP DAS USA
ICP DAS USA CAN-2060C quick start

M-system
M-system R7M-DC8C instruction manual