READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
· To reduce the risk of death, personal injury or property damage from re, electric shock, falling parts, cuts/
abrasions, and other hazards please read all warnings and instructions included with and on the xture box and
all xture labels.
· Before installing, servicing, or performing routine maintenance upon this equipment, follow these general
precautions.
· Installation and service of luminaires should be performed by a qualied licensed electrician.
· Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and
operation and any hazards involved. Regular xture maintenance programs are recommended.
· It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on
ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a
solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry.
Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing
damaged gaskets as necessary.
· DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have
been damaged during transit. Inspect to conrm. Any part damaged or broken during or after assembly should
be replaced.
· Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
· These instructions do not purport to cover all details or variations in equipment nor to provide every possible
contingency to meet in connection with installation, operation, or maintenance. Should further information
be desired or should particular problems arise which are not covered suciently for the purchaser’s or owner’s
purposes, this matter should be referred to Acuity Brands Lighting, Inc.
Disconnect or turn o power before installation or
servicing.
Verify that supply voltage is correct by comparing it with
the luminaire label information.
Make all electrical and grounded connections in
accordance with the National Electrical Code (NEC) and
any applicable local code requirements.
All wiring connections should be capped with UL
approved recognized wire connectors.
WARNING
RISK OF ELECTRIC SHOCK
Allow lamp/xture to cool before handling. Do not
touch enclosure or light source.
Do not exceed maximum wattage marked on
luminaire label.
Follow all manufacturer’s warnings, recommendations
and restrictions for: driver type, burning position,
mounting locations/methods, replacement and
recycling.
WARNING
RISK OF BURN
CAUTION
RISK OF FIRE
Keep combustible and other materials that can burn,
away from lamp/lens.
Do not operate in close proximity to persons,
combustible materials or substances aected by heat
or drying.
CAUTION
RISK OF INJURY
Wear gloves and safety glasses at all times when
removing luminaire from carton, installing, servicing or
performing maintenance.
Avoid direct eye exposure to the light source while it is on.
Please see product specic installation instructions for additional warnings or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.
Our Brands Indoor/Outdoor Indoor Lighting Outdoor Lighting Controls Daylighting
Lithonia Lighting Gotham American Electric Lighting DARK TO LIGHT SunOptics
Carandini Mark Architectural Lighting Antique Street Lamps LC&D
Holophane Peerless Hydrel ROAM
RELOC Renaissance Lighng Tersen Sensor Switch
Light Concepts Winona Lighting Synergy
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
Never connect components under load.
Do not mount or support these xtures in a manner that can cut the outer jacket or damage wire
insulaon.
Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the
luminaire must be checked for compability with the luminaire prior to installaon. LED xtures must
be powered directly o a switched circuit.
Unless individual product specicaons deem otherwise: Do not restrict xture venlaon. Allow for
some volume of airspace around xture. Avoid covering LED xtures with insulaon, foam, or other
material that will prevent convecon or conducon cooling.
Unless individual product specicaons deem otherwise: Do not exceed xtures maximum ambient
temperature.
Only use xture in its intended locaon.
LED products are Polarity Sensive. Ensure proper Polarity before installaon.
Electrostac Discharge (ESD): ESD can damage LED xtures. Personal grounding equipment must be
worn during all installaon or servicing of the unit.
Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter
performance.
Some components inside the xture may not be serviceable. In the unlikely event your unit may
require service, stop using the unit immediately and contact an ABL representave for assistance.
Always read the xtures complete installaon instrucons prior to installaon for any addional xture
specic warnings.
CAUTION: RISK OF PRODUCT DAMAGE
Installation Instructions
RSX LED
5 year limited warranty
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com Part Number: IM-459 Rev A
Revision Date: 8/29/19
SPA & RPA, see sheet 2 MA, see sheet 4
IS, see sheet 8
WBASC, see sheet 10 AASP/AARP/AAWB/AAWSC, see sheet 12
WBA, see sheet 10
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.
DELIVERY: Upon receipt of xture and accessories (packed separately), thoroughly inspect for any freight damage. All dam-
age should be reported to the delivery carrier. Compare the catalog description listed on the packing slip with the xture
label on the inside of the housing to be sure to correct merchandise was received.
Page #1
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Installation Instructions
RSX LED
RSX SPA/RPA & ESPA/ERPA INSTALLATION INSTRUCTION
Tools Required:
• 3/8" Socket Wrench
• 9/64” Allen Wrench
Minimum Square Pole: 3.5” Face
Minimum Round Pole: 3.2” Diameter
1. Loosen the capve screws of the arm cover (Fig 1) to
access the pole mounng area
2. Two mounng bars are included in the installaon kit:
a. The shorter bar is used for #8 Lithonia drilling paern
and has 3 holes. The top and boom hole are threaded.
b. The longer bar has one top hole and a slot with a slid-
ing threaded hole to be used on poles with exisng drill pat-
terns.
3. If the bar with the #8 drilling paern
(Fig 2a) does not line up with exisng holes,
use the universal mounng bar (Fig 2b) with
the sliding thread.
Insert one of the included 3/8 mounng
bolts through the top hole of the pole and
thread into the mounng bar. For a round
pole, the round pole adapter (RPA) is re-
quired and must be placed between the pole
and the xture as shown with the curved
side contacng pole and at side facing away
from pole (Fig 2c).
Figure 1
Part Number: IM-459 Rev A
Revision Date: 8/29/19
Page #2
Installation Instructions
RSX LED
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19
4. The luminaire is supplied with a variety of slots to
align with exisng pole mounng drill paerns. The top
hole of the luminaire arm has a key hole slot.
Place the luminaire onto the top bolt by passing the
head through the key slot and resng the luminaire
down securely in place (See Fig 3).
WARNING: THE LUMINAIRE IS NOT COMPLETELY
LOCKED DOWN YET. SPECIAL CARE MUST BE TAKEN TO
AVOID JARRING THE LUMINAIRE FROM ITS RESTING
POINT
Ensure the luminaire is resng securely on the top bolt
and snug the bolt but do not completely ghten yet.
Thread the second bolt through the arm slot and into
the available threaded hole of the mounng bar (See
Fig 4).
5. The luminaire is supplied with a clearance slot in the
back to allow wires to be pulled into the pole on exist-
ing hole paerns. Insert the wires through the clear-
ance slot shown in Figure 5 and pull them into the pole.
6. Ensure luminaire is straight/level making sure that
no wires are pinched, ghten the two bolts with a 3/8
socket to 20-30-lbs (overghtening can damage com-
ponents and void warranes). Make sure that wires are
not pinched and tuck excess wire up into the luminaire
mounng area.
7. Reinstall the cover removed in step 1, ghten the two
capve screws with the 9/64 Allen wrench to 18-20 in-
lbs (overghtening can cause thread stripping and void
all warranes) (See Fig 6).
8. Make wire connecons in the pole, observing proper
voltage and polarity. Connect green ground wire from
the xture to the eld ground wire. Secure wires; push
back into pole and replace pole cap.
Page #3
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Installation Instructions
RSX LED
Part Number: IM-459 Rev A
Revision Date: 8/29/19
RSX MAST ARM ADAPTOR INSTALLATION
Tools Required:
• 5/8" Socket wrench
• 3/16" Allen wrench
• 5/32" Allen wrench
Minimum tenon/pole diameter: 2" schedule 40 pipe (2-3/8"OD)
1. Slip luminaire Mast Arm Mount over 2-3/8” Ø pole tenon (See Figure 7a).
2. Use provided set screws and secure the luminaire in required posion to drill the thru hole.
3. Use thru-bolt hole provided as pilot and drill 1/2" Ø hole on tenon through mast arm from both side (See Figure 7b).
Ensure no wires are at risk of being damaged by the drilling operaon.
Page #4
Installation Instructions
RSX LED
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19
3. Loosen the set screws enough to ip the luminaire over as shown below in gure 8a, then loosen the six capve screws
on door to access the wire connecon area. Remove the rubber grommet (see gure 8b) before feeding the wires.
4. Remove the luminaire from the tenon to insert input wires through the holes of the rubber grommet, pull them into the
wire connecon area. Replace the rubber grommet back as originally assembled before wire feeding (See Figure 8b & 8c).
Page #5
Installation Instructions
RSX LED
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-479 Rev A
Revision Date: 8/28/19
5. Insert the ground wire from tenon to the 3-way wire nut with the green wires from SPD and luminaire ground connecon
and lock it. Repeat this step for black (hot) and white (neutral) wires. Select matching colored wires coming from SPD (See
Figure 9a, 9b, 9c).
6. Use cable e and bundle all newly aached wires as
shown in Figure 10.
7. Make sure that wires and door tethers are not pinched
and that the door gasket is sll snugly in its groove on the
door. Reinstall the mounng door (Fig 11) that was re-
moved, ghten the six capve screws with the 5/32 Allen
wrench to 25-30 in-lbs (overghtening can cause thread
stripping and void all warranes).
Page #6
Installation Instructions
RSX LED
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19
8. Reorient luminaire to desired posion on the tenon and Insert provided 7/16"-14 x 4-1/2" bolt through Mast Arm Mount
and drilled 1/2" Ø hole on tenon and place provided 7/16" nut onto bolt (see gure 12) and ghten securely to 45-50 -lbs.
9. Evenly ghten the Six (6) 3/8-16 UNC Mast Arm Set Bolts while maintaining the correct posion of the luminaire to 23-27
-lbs.
10. Energize the luminaire to verify its operaon and proper illuminaon of area.
WARNING: USE AND PROPERLY TIGHTEN THRU-BOLT AND NUT. FAILURE TO CORRECTLY INSTALL COULD RESULT IN SERIOUS
INJURY OR PROPERTY DAMAGE
Page #7
Installation Instructions
RSX LED
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19
Tools Required:
• 9/64” Allen Wrench
• 5/16” Allen Wrench
• 3/8” Allen Wrench
Maximum tenon/pole diameter: 2” schedule 40
pipe (2-3/8” OD)
NOTE: This luminaire is pre-wired with UL listed
supply wire leads. It is not necessary to access
xture housing to install or wire the luminaire.
1. Remove the two (2) 8-32 splice access cover
fasteners from knuckle assembly, remove the
splice access cover, and pull supply wire leads
from knuckle cavity (See gures 13a and 13b)
2. Slip luminaire knuckle er over 2-3/8” Ø
pole tenon and evenly ghten the six (6) 3/8-16
UNC knuckle tenon set screws to 23-27 -lbs,
while maintaining the correct posion of the
luminaire
3. Cut and splice the wires. Recommended cut
length is 6" for wires for ease of splicing and
securing in the knuckle
4. Make all wiring connecons via the supplied
wire leads in accordance with NEC and local
codes.
5. Push all xture and supply wires completely
within the knuckle cavity and replace the splice
access cover, gasket, and two (2) 8-32 splice ac-
cess cover fasteners.
RSXF INTEGRAL SLIPFITTER (IS) INSTALLATION ON VERTICAL TENONS (+/- 5 °)
Note: Luminaire can be lted up to 90 degrees (maximum) above horizontal.
Page #8
Installation Instructions
RSX LED
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19
Page #9
6. Aim xture as required and tighten the 7/16-14 SHC knuckle adjustment bolt using an approximately
38 -lbs. (See gure 14) For units with photocontrol receptacle, the xture mounting/aiming angle must be
restricted from 0° to 45° from horizontal per ANSI C136.10-2010.
7. Energize the luminaire to verify its operation and proper illumination of area.
WARNING: DO NOT MOUNT THE KNUCKLE FITTER TO A TENON OR BRACKET THAT IS MORE
THAN 5 DEGREES FROM VERTICAL. MOUNTING AT AN ANGLE GREATER THAN 5 DEGREES RE-
QUIRES USE OF A PROPERLY TIGHTENED THRU-BOLT AND LOCKNUT. FAILURE TO CORRECTLY
INSTALL COULD RESULT IN SERIOUS INJURY OR DEATH.
Figure 14
Emergency
Magnetic Switch
Installation Instructions
RSX LED
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19
RSX WBA & WBASC INSTALLATION
Tools Required:
• 9/16" Socket wrench
• 9/64" Allen wrench
• 3/16" Allen wrench
• Flathead Screwdriver (WBASC opon only)
CAUTION: APPLY A CONTINUOUS BEAD OF WEATHER – PROOF CAULKING BETWEEN MOUNTING BASE PLATE AND WALL TO
ENSURE WEATHER–TIGHT INTEGRITY OF ELECTRICAL COMPONENTS (See Fig 13a or 13b)
1. Place the base plate in orientaon shown in Figures 15a (WBASC) and 15b (WBA) and secure to wall with secure base plate
to wall with (4) 1/4” diameter fasteners (not included with luminaire) using the (4) holes located on the outer corners of the
base plate. Check the base plate to conrm that it is level and plumb in all direcons (See Figure 15b). Note that the WBA and
WBASC have slightly dierent mounng paerns for the ¼” bolts.
2. WBASC OPTION ONLY: With the base plate securely fastened to the wall, remove the desired conduit plug(s) from the base
plate using a at head screwdriver, feed in supply wires, and aach ¾ NPT conduit pipe.
3. Prepare the cover plate by ensuring the factory-installed, black foam gasket is in place on the backside of the cover plate
(See Fig 16) NOTE: For the next steps the curved poron of the cover plate should point upwards when mounted to the wall as
shown in gure 18.
Page #10
Installation Instructions
RSX LED
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19
4. Loosen the two cover screws of the SPA to access the pole mounng area (See Fig 17) and route supply wires through the
clearance slot and WBA cover hole.
5. Making sure that no wires are pinched, insert the 3/8” bolts (included with luminaire) through the mounng arm of the
xture housing, through the cover plate, and then thread into the threaded steel bar (See Fig 18). Tighten the two bolts with a
9/16” socket to 20-30 -lbs (overghtening can damage components and void warranes).
6. Make sure no wires are pinched and tuck excess wire up into the luminaire mounng area and reinstall the SPA Cover that
was removed in step 3. Tighten the two cover screws with the 9/64 Allen wrench to 18-20 in-lbs (overghtening can cause
thread stripping and void all warranes).
CAUTION: THE NEXT STEPS WILL REQUIRE ASSISTANCE
7. Make all wiring connecons via the supplied wire leads in accordance with NEC and local codes.
8. Place the enre light xture/cover plate assembly onto the base plate (installed in step 1) and have someone ghten the top
(2) 3/8” x 1-1/4” stainless steel recessed hex set screws (See Fig 19) unl 3/8” to 1/4” of the screw threads are sll visible, then
ghten the boom set screws.
9. Now, alternang between the top and boom set screws, gently ghten unl snug (approximately one thread will remain
showing on each screw).
Page #11
Installation Instructions
RSX LED
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19
NOTE: Luminaire can be lted up to 90 degrees above horizontal
Tools Required:
• 3/8" Socket Wrench
• 9/64" Allen wrench
• 3/8” Allen Wrench
Minimum Square Pole: 3.5” Face
Minimum Round Pole: 3.2” Diameter
1. Loosen the cover screws of the arm cover (See gure 20) and
remove the cover to gain access to the top half of the key-slot
mounng feature.
2. Idenfy which mounng bar should be used to aach the
luminaire to the pole. Refer to the RPA/SPA installaon instruc-
ons, steps 2 through 6. Note that main dierence in mounng
is that the top bolt on the AASP/AARP will be inside the wiring
area and the boom bolt will be exposed. Once the luminaire is
mounted securely to the pole, the angle of the luminaire can be
safely adjusted.
3. If the luminaire angle will be adjusted DO NOT pull
the luminaire supply wires taut – leaving slack in the input wires
will make angle adjustment easier. If the luminaire angle will not
be adjusted, skip to step 5.
4. Loosen the 7/16-14 adjustment bolt, reorient luminaire as
desired, up to 90°, and reghten adjustment bolt to 35-40 -lbs
(See Fig 21). For units with photocontrol receptacle, the xture
mounng angle must be restricted per ANSI C136.10 and it is
recommended to not install beyond 45° from horizontal.
5. Make all wiring connecons via the supplied wire leads in ac-
cordance with NEC and local codes.
6. Ensure that the arm cover gasket is sll in place and place it
back in the channel if it has come loose.
7. Place wires back into the arm cavity and, ensuring that no
wires or tethers are going to be pinched, reaached the arm
cover. Tighten the cover screws to 18-20 in-lbs.
8. Energize the luminaire to verify its operaon and proper il-
luminaon of area.
AASP/AARP INSTALLATION INSTRUCTIONS
Page #12
Installation Instructions
RSX LED
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19
AAWB/AAWSC INSTALLATION INSTRUCTIONS
NOTE: Luminaire can be lted up to 90 degrees above horizontal
Tools Required:
• 9/64” Allen Wrench
• 5/32” Allen Wrench
• 3/16” Allen Wrench
• Flathead Screwdriver (AAWSC only)
Minimum Square Pole: 3.5” Face
Minimum Round Pole: 3.2” Diameter
CAUTION: APPLY A CONTINUOUS BEAD OF WEATHER – PROOF CAULKING BETWEEN MOUNTING BASE PLATE AND WALL TO
ENSURE WEATHER–TIGHT INTEGRITY OF ELECTRICAL COMPONENTS (See Fig 15a & 15b)
1. Install the wall-mount base plate, refer to steps 1-3 outlined in the WBA/WBASC installaon instrucons on sheet 9. Note
that the image above shows the AAWSC opon.
2. Before mounng the luminaire, remove the arm cover (See gure 20 on the previous page) and unpack the luminaire input
wires, if necessary, to make roung supply wires into the arm cavity easier.
Page #13
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19
Installation Instructions
RSX LED
3. While one person supports the luminaire, route the
supply wires through the mounng plate and into the arm
cavity. Make all electrical connecons in accordance with
NEC and local codes. Ensure that wires coming out of the
luminaire have some slack, this will make aiming the lumi-
naire easier and will ensure no wires are pinched or strained
when aiming.
4. Place the enre luminaire assembly onto the base plate
(gures 22) and have the second person ghten the top two
(2) 3/8” x 1-1/4” stainless steel recessed hex set screws (See
gure 19) unl 3/8” to 1/4” if the screw threads are sll vis-
ible, ghten the boom set screws to the same length.
5. Now alternang between the top and boom sets of
set screws, gently ghten unl snug. If the base plate was
installed level, approximately 1 threads should be visible on
each set screw aer all screws have been fully ghtened.
6. If the luminaire aiming angle will not be adjusted, skip
to the next step, otherwise loosen the 7/16-14 adjustment
bolt, reorient luminaire as desired, up to 90° from horizon-
tal, and reghten the adjustment bolt to 35-40 -lbs (See
gure 21).
For units with photocontrol receptacle, the xture mounng
angle must be restricted per ANSI C136.10 and it is recom-
mended to not install beyond 45° from horizontal.
7. Reaach the arm cover. Make sure that the cover gasket
is securely placed in its groove and that all wires and tethers
are move out of the way so that they are not pinched when
the cover is put back into place. Tighten the cover screws to
18-20 in-lbs.
8. Energize the luminaire to verify its operaon and proper
illuminaon of area.
CAUTION: THE NEXT STEPS WILL REQUIRE ASSISTANCE
Page #14
Installation Instructions
RSX LED
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19
RSX FAO SETTING INSTRUCTIONS
NOTE: If FAO does not need to be adjusted (default seng is maximum output), install luminaire as normal.
1. Loosen six capve screws and remove RSX door to access the luminaire electronics (Fig 23). Set aside for reinstallaon.
2. In all RSX family luminaires, the FAO module is in the approximate locaon shown in gure 24a. Use a at-head screwdriver
to turn the FAO dial (gure 24b). Note that posion 8 is the default seng and the maximum output value (no dimming).
For Contractor Select conguraons, refer table 1 on the next sheet for lumen output values.
Page #15
Installation Instructions
RSX LED
©2016 Acuity Brands Lighting, Inc.
All Rights Reserved.
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: IM-459 Rev A
Revision Date: 8/29/19
3. Make sure that wires and door tethers are not pinched and that the door gasket is sll snugly in its groove on the door. Re-
install the mounng door that was removed in step 1, ghten the six capve screws with the 5/32 Allen wrench to 25-30 in-lbs
(overghtening can cause thread stripping and void all warranes).
Page #16

This manual suits for next models

9

Other Acuity Brands Lighting Outdoor Light manuals

Acuity Brands Lighting Holophane Wallpack HLWCP2 Manual

Acuity Brands Lighting

Acuity Brands Lighting Holophane Wallpack HLWCP2 Manual

Acuity Brands Lighting Lithonia Lighting CSXW LED User manual

Acuity Brands Lighting

Acuity Brands Lighting Lithonia Lighting CSXW LED User manual

Acuity Brands Lighting Holophane High Mast System 2 Manual

Acuity Brands Lighting

Acuity Brands Lighting Holophane High Mast System 2 Manual

Acuity Brands Lighting Lithonia Lighting LDN8 SWW User manual

Acuity Brands Lighting

Acuity Brands Lighting Lithonia Lighting LDN8 SWW User manual

Acuity Brands Lighting Holophane 05 User manual

Acuity Brands Lighting

Acuity Brands Lighting Holophane 05 User manual

Acuity Brands Lighting Lithonia Lighting FML4W Wrap User manual

Acuity Brands Lighting

Acuity Brands Lighting Lithonia Lighting FML4W Wrap User manual

Acuity Brands Lighting Pedestrian LED Luminaire Series Manual

Acuity Brands Lighting

Acuity Brands Lighting Pedestrian LED Luminaire Series Manual

Acuity Brands Lighting Holophane 25 User manual

Acuity Brands Lighting

Acuity Brands Lighting Holophane 25 User manual

Acuity Brands Lighting Lithonia Lighting LIL LED 30K MVOLT User manual

Acuity Brands Lighting

Acuity Brands Lighting Lithonia Lighting LIL LED 30K MVOLT User manual

Acuity Brands Lighting Holophane 15 User manual

Acuity Brands Lighting

Acuity Brands Lighting Holophane 15 User manual

Acuity Brands Lighting Lithonia Lighting HLA LED User manual

Acuity Brands Lighting

Acuity Brands Lighting Lithonia Lighting HLA LED User manual

Popular Outdoor Light manuals by other brands

Quoizel TFIK8411VA Assembly instruction sheet

Quoizel

Quoizel TFIK8411VA Assembly instruction sheet

physa MF-22 user manual

physa

physa MF-22 user manual

Beachside Lighting MB-SERIES quick start guide

Beachside Lighting

Beachside Lighting MB-SERIES quick start guide

LIGMAN TRIANGLE 5 installation manual

LIGMAN

LIGMAN TRIANGLE 5 installation manual

V-TAC VT-762-2 instruction manual

V-TAC

V-TAC VT-762-2 instruction manual

IKEA ORGEL VRETEN quick start guide

IKEA

IKEA ORGEL VRETEN quick start guide

WE-EF VFL500-SE Series Installation and maintenance instructions

WE-EF

WE-EF VFL500-SE Series Installation and maintenance instructions

Philips 16942-93-16 user manual

Philips

Philips 16942-93-16 user manual

Vaxcel T0321 Assembly and installation instructions

Vaxcel

Vaxcel T0321 Assembly and installation instructions

Home Decorators Collection Y37029A-151 Use and care guide

Home Decorators Collection

Home Decorators Collection Y37029A-151 Use and care guide

Delta Light WALKER 55 HP quick start guide

Delta Light

Delta Light WALKER 55 HP quick start guide

Gude L 18 Translation of the original instructions

Gude

Gude L 18 Translation of the original instructions

LIGMAN VANCOUVER 61 installation manual

LIGMAN

LIGMAN VANCOUVER 61 installation manual

FiberLamp FL5600 Operation manuals

FiberLamp

FiberLamp FL5600 Operation manuals

FLOS TOIO manual

FLOS

FLOS TOIO manual

Totec AMA-SW01 quick guide

Totec

Totec AMA-SW01 quick guide

LIGMAN AQUA 4 installation manual

LIGMAN

LIGMAN AQUA 4 installation manual

LIGMAN HAMILTON4 installation manual

LIGMAN

LIGMAN HAMILTON4 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.