OPERATING INSTRUCTIONS & PARTS MANUAL
16" REVERSIBLE WINDOW FAN 16" (40,64 cm)
Model 2EJR6G/9155G
Motor...................................................................... 120V, 60 Hz
Blade size .............................................................. 16" (40,6 cm)
Speeds................................................................... 3 intake, 3 exhaust
Control ................................................................... Rotary switch
Approvals................................ ETL Listed. Close mesh fan guard
meets OSHA requirements.
Specifications
Description
The Air King®window fan features three intake and three exhaust
speeds and fits windows 26 1/2" (67,3 cm) to 34 1/2" (87,6 cm) wide
to 22" (55,9 cm) high. The adjustable side panels are designed to
accommodate fan mounting either inside or outside interior window
trim. The 16" (40,64 cm), 3-paddle fan blade is driven by a perma-
nently prelubricated motor, 6 foot (1,8 m), 18/3 cord set.
Rev. G 11/15 12082048A
Rev. G 11/15 82082048A
MODELO 2EJR6G/9155G
MODEL 2ERJ6G/9155G
SPEED HIGH MED LOW
CFM 2470 1700 1360
M3/s 1.17 0.80 0.64
RPM 1480 1110 820
Amps 0.80 0.63 0.50
Watts 90 76 61
dB A 64 50 47
13
14
15
16
17
18
19
20
21
22
23
PARTE
NO. CANT.
NO.
REF DESCRIPCIÓN
4
4
4
1
1
1
1
1
1
1
1
CANT.
NO.
REF DESCRIPCIÓN
*
2090005
2090006
2011805
2011227
*
2090124
2011215
02065508G
*
02070027
PARTE
NO.
Botón
Placa del interruptor
Tornillo #8 x 5/8" HWH
Cubierta del motor
Tornillo #6 x 5/8"
Protector interior
Cordón eléctrico
Tornillo #8 x 3/8" HWH
Collar de fijación de la cubierta del motor
Interruptor
Motor
Panel lateral
1
2
3
4
5
6
7
8
9
10
11
12
2010115
02065209
*
2010609
*
02096025W
02050111A
2091169
2010703
2055052
02030116
2011815
1
1
9
1
6
1
1
1
1
1
1
2
Tornillo para madera #8 x 3/4"
Tornillo #10 x 3/4"
Tuerca tinnerman de ajuste rápido
Cuerpo
Paletas
Arandela de bloqueo con dientes ext #8
Tuerca 1/4-20 LH
Protector exterior
Placa rotulada
Arandela de bloqueo con dientes ext #8
Accesorio del botón
(*) Artículo común de ferretería, a la venta localmente.
Lista de repuestos
Figura 7 - Ilustración de repuestos
GARANTÍA LIMITADA
QUÉ CUBRE ESTA GARANTÍAS: Este producto está garantizado contra defectos de mano de obra y/o materiales.
CUÁNTO DURA ESTA GARANTÍA: Esta garantía se extiende únicamente al comprador original del producto y dura un (1) año a partir de la fecha original de
compra o hasta que el comprador original del producto venda o transfiera el producto, cualesquiera de ambas que ocurriera en primer lugar.
QUÉ HARÁ Air King: Air King, a opción propia, reparará o reemplazará cualquier parte o partes que demuestren ser defectuosas o reemplazará el producto
completo por el mismo modelo u otro comparable. Para todas las reclamaciones de garantía, se debe devolver el producto a Air King Products, Inc. a cargo del
cliente con la prueba de compra dentro del período de garantía. Comuníquese con el departamento de atención al cliente de Air King para obtener una Autorización
de Devolución (“RA”, por sus siglas en inglés). NO devuelva los productos sin una RA o no se procesará la reclamación de la garantía.
QUÉ NO CUBRE ESTA GARANTÍA: Esta garantía no tiene validez si el producto fue dañado o falló debido a un accidente, manipulación u operación inadecuadas,
daño en el envío, abuso, mal uso, reparaciones no autorizadas hechas o el intento de hacerlas, o el uso del producto para servicio comercial o no residencial.
Esta garantía no cubre los costos de envío para la devolución de productos a Air King para su reparación o reemplazo. Air King abonará los cargos de envío de
devolución a Air King con posterioridad a las reparaciones o el reemplazo bajo garantía.
CUALESQUIERA Y TODAS LAS GARANTÍAS, EXPLÍCITAS O IMPLÍCITAS (INCLUYENDO, SIN LIMITACIÓN, CUALESQUIERA GARANTÍA IMPLÍCITA DE
COMERCIABILIDAD), DURAN UN AÑO A PARTIR DE LA FECHA ORIGINAL DE COMPRA O HASTA QUE EL COMPRADOR ORIGINAL DEL PRODUCTO VENDA
O TRANSFIERA EL PRODUCTO, CUALESQUIERA DE AMBAS QUE OCURRIERA EN PRIMER LUGAR Y EN NINGÚN CASO LA RESPONSABILIDAD DE Air King
BAJO CUALQUIER GARANTÍA EXPLÍCITA O IMPLÍCITA INCLUIRÁ (I) DAÑOS INCIDENTALES O POR CONSECUENCIA POR CUALQUIER CAUSA QUE FUERE,
O (II) REEMPLAZO O REPARACIÓN DE CUALESQUIERA FUSIBLES HOGAREÑOS, CORTA-CIRCUITOS O TOMACORRIENTES. INDEPENDIENTEMENTE DE
CUALQUIER DECLARACIÓN CONTRARIA, EN NINGÚN CASO LA RESPONSABILIDAD DE Air King BAJO CUALQUIER GARANTÍA EXPLÍCITA O IMPLÍCITA PODRÁ
EXCEDER EL PRECIO DE COMPRA DEL PRODUCTO Y DICHA RESPONSABILIDAD TERMINARÁ AL VENCIMIENTO DEL PERÍODO DE GARANTÍA.
Algunos estados y provincias no permiten limitaciones sobre la duración de una garantía implícita, o sobre la exclusión o limitación de los daños incidentales o por
consecuencia, por lo tanto dichas exclusiones o limitaciones podrían no aplicarse en su caso. Esta garantía le otorga a usted derechos legales específicos. Usted
también podría tener otros derechos que varían de estado en estado y de provincia en provincia.
Se requiere prueba de compra antes que se acepte un reclamo bajo garantía.
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE,
INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RE-
SULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
10 22
5
17
3
8
7
3
23
1
2
4
5
6
9
11
12
13
14 15
16
21
20
18
19
Rev. G 11/15 22082048A Rev. G 11/15 72082048A
MODELO 2EJR6G/9155G
MÉTODO A: (Exterior del contramarco)
Herramientas necesarias: Tornillería incluida:
Destornilladores Cuatro tornillos #8 x 3/4 con
cabezas ranuradas
1. Afloje los tornillos “B”
y extienda los paneles
laterales de manera que
libren el borde exterior
del contramarco a am-
bos lados de la ventana. Figura 1
Ranura C
2. Descanse el ventilador en el
antepecho de la ventana con
las salientes de los paneles
laterales sobre el contrama-
rco. Presione los paneles
laterales contra el borde
exterior del contramarco. Figura 2
3. Con el panel lateral en posición, marque la ubicación de los tornillos
en la parte superior de la ranura “C” y atornille los 4 tornillos “A” para
madera (incluidos) hasta que queden apretados.
4. Apriete los 4 tornillos “B” del alojamiento del ventilador y habrá comple-
tado la instalación.
Figura 3
1. Marque la ubicación de los
tornillos sobre los bordes in-
teriores del contramarco de la
ventana utilizando la plantilla
incluida tal como se muestra
en la ilustración.
2. Atornille los 4 tornillos “A” en
el contramarco. NO LOS APRI-
ETE HASTA EL TOPE. Deje un
espacio de 1/8" (3.2 mm) entre
las cabezas de los tornillos y
el contramarco de la ventana.
MÉTODO B: (Interior del contramarco)
Herramientas necesarias: Tornillería incluida:
Destornilladores Cuatro tornillos #8 x 3/4 con
cabezas ranuradas
ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIOS O DESCAR-
GAS ELÉCTRICAS, NO USE ESTE VENTILADOR CON NINGÚN DISPOSI-
TIVO DE CONTROL DE VELOCIDAD DE ESTADO SÓLIDO.
INSTALACIÓN
La gran variedad de estilos y tipos de ventanas hace imposible describir un
procedimiento de instalación universal.
Los métodos esbozados a continuación se recomiendan como aptos para
la mayoría de los estilos más comunes de ventanas de guillotina. Sea
cual sea el método que usted elija, asegúrese de que la ventana cierre
fácilmente, para su seguridad y para proteger sus muebles contra las
condiciones meteorológicas. Refiérase a las ilustraciones al ir siguiendo el
Método A o B a continuación.
Figura 4
3. Afloje los 4 tornillos “B”
y extienda los paneles a
cada lado del alojamien-
to hasta que el ventila-
dor ajuste exactamente
entre el contramarco
izquierdo y derecho de
la ventana.
Ranura C
4. Monte el ventilador en
la ventana haciendo que
las ranuras “C” entren en
los tornillos “A” del borde
interior del contramarco.
Baje el ventilador sobre
los tornillos “A” hasta que
descanse en el antepecho
de la ventana o en la mol-
dura del marco de ésta.
Ranura C Figura 5
5. Apriete el tornillo “B” del
alojamiento para fijar el
ventilador en posición. Figura 6
Operación
El ventilador de ventana Air King® es accionado por un durable motor de
condensador divisor de 3 velocidades, reversible eléctricamente. (Existe
velocidad alta, media y baja en modalidad tanto de entrada como de
salida.) El interruptor de control del motor se encuentra convenientemente
localizado en la cubierta del motor. Ajuste el control a la dirección y veloci-
dad deseadas.
SOLO PARA RESIDENTES DE CALIFORNIA:
ADVERTENCIA: Este producto puede exponerle a un
producto químico [o productos químicos] conocido(s) por el
Estado de California como causante de cáncer.
ADVERTENCIA: Este producto puede exponerle a un
producto químico [o productos químicos] conocido(s)
por el Estado de California como causante de toxicidad
reproductiva.
MANTENIMIENTO
ADVERTENCIA: SIEMPRE
DESENCHUFE EL CABLE ANTES DE
MOVER O DAR SERVICIO AL VENTILADOR.
ADVERTENCIA:¡NOSUMERJAEL VENTILADOR
EN AGUA!
LIMPIEZA: Utilice un paño suave humedecido con una
soluciónjabonosaliviana,tal comoundetergentelíquido para
lavar platos. Seque TODAS LAS PARTES POR COMPLETO
antesde rearmar. Después de dar mantenimientoo servicio,
REARMEPOR COMPLETO la unidad en la forma descritaen
este manual de instrucciones, antes de volver a conectarla
a la fuente de poder.
PRECAUCIÓN: No utilice gasolina, bencina, acetona,
limpiadoresabrasivos,etc.puestoquedañaránelVentilador.NUNCAuseALCOHOL
O SOLVENTES.
LUBRICACIÓN: Los cojinetes de precisión vienen sellados de por vida en la
fábrica y no precisarán ninguna lubricación adicional.
ALMACENAMIENTO: Guarde el Ventilador con estas instrucciones en un
lugar fresco y seco.
DISPOSICIÓN: Los materiales de empaque de cartón corrugado son
reciclables. Para desechar este producto de manera ecológicamente
responsable, comuníquese con su proveedor de servicio de desechos local
o visite www.1800recycling.com®
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION
When using electrical appliances, basic precautions should always be followed to reduce
the risk of fire, electrical shock and injury to persons, including the following:
Read all instructions before using this Fan.
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR PERSONAL INJURY, ALWAYS
FOLLOW THESE IMPORTANT SAFETY INSTRUCTIONS AND WARNINGS:
DO NOT use this fan to ventilate areas where flammable liquids or vapors are used, stored or are present, including paints, gaso-
line, varnishes, floor refinishing products or solvents. ALWAYS read and follow all warnings and instructions on the containers for
these products!
ALWAYS be sure the plug fits tightly into the outlet. When plugs fit loosely into outlets, they may slip partially out of the outlet and
create a poor connection. This may cause outlets to overheat and create a potential fire hazard. Outlets in this condition should be
replaced by a qualified electrician.
ALWAYS unplug the power cord when servicing, cleaning or moving the Fan. DO NOT use the ON/OFF switch as the sole means of
disconnecting power. NEVER leave children unattended when the Fan is on or plugged in. ALWAYS turn off and unplug the Fan when
not in use.
BE CERTAIN that the power source for the Fan is 120V AC. DO NOT plug the Fan into 240V or other power source.
The Blue Plug™ on your AirKing fan is a safety feature. It contains a non-replaceable safety device (fuse) that should not be removed or
tampered with. To reduce the risk of fire, electric shock and personal injury, DO NOT attempt to remove, replace, repair or tamper with
the originally supplied plug. If the Fan has stopped functioning, it may be due to the safety device incorporated in this plug.
The power cord is equipped with a three-prong grounded plug that must be inserted into a matching receptacle. Under no circum-
stances should the grounding prong be cut off the plug. Where a two-prong wall receptacle is encountered, it must be replaced
with a properly grounded three-prong receptacle installed in accordance with the National Electrical Code (NEC) and all applicable
local codes and ordinances. This work must be done only by a qualified electrician, using copper wire only.
DO NOT USE A THREE-PRONG TO TWO-PRONG ADAPTER. IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTRI-
CAL SHOCK. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.
• AVOID the use of extension cords, power strips, power taps, outlet style air fresheners or other cord connected device, as these de-
vices may overheat and cause a fire hazard.
•DO NOT route power cord under rugs, carpets, runners or furniture. This may damage the cord or cause it to overheat creating a fire hazard.
•ALWAYS place the Fan on a stable, flat, level surface while in operation to prevent the Fan from overturning.
•NEVER insert or allow fingers or objects to enter grill openings while Fan is in operation or injury and/or damage to the Fan may occur.
•DO NOT block, cover or obstruct air flow to or from the fan while in operation.
•DO NOT use this Fan outdoors or near water or wet locations such as a bath tub, pool or hot tub. Use of this Fan in a wet location may
create a shock hazard.
•DO NOT run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or
appliances. Arrange cord away from traffic area and where it will not be tripped over.
•NEVER use a single extension cord to operate more than one Fan or other electrical device.
•DO NOT use this Fan if it has been damaged or is not functioning properly.
•THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008).This Fan is not suitable for use in agricultural facili-
ties including areas where livestock, poultry or other animals are confined. Please refer to National Electric Code (NEC) Article 547-7
(2008), or applicable state or local codes or standards relating to electrical requirements for agricultural buildings.
•THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008).This Fan is not suitable for use in hazardous
locations. Please refer to National Electric Code (NEC) Article 500 or applicable state or local codes or standards relating to electrical
requirements for hazardous locations.
CAUTION
B
B
B
B
1/8" (3.2mm)
TEMPLATE
A
B
B
A
A
B
B
Rev. G 11/15 6 2082048A Rev. G 11/15 2082048A
3
MODEL 2EJR6G/9155G
1. Mark screw locations on
inside edges of window trim
using enclosed template as
shown in illustration.
2. Drive 4 screws "A" into trim.
DO NOT TIGHTEN FLUSH.
Leave
1/8" (3.2 mm) space between
screw heads and window trim.
Figure 3
METHOD B: (Inside of Trim)
Tools Required: Hardware Provided:
Screwdrivers Four - #8 x 3/4" slotted head screws
Installation
The large number of window styles and types makes it impossible
to describe one universal installation procedure. The methods
outlined below are recommended as being well-suited for most
common styles of double-hung windows. Whichever method you
choose should allow the window to be closed easily for security
and protection of home furnishings against the weather. Refer to
illustrations while following Methods A or B below.
3. With side panel in posi-
tion, mark screw loca-
tions at top of slot "C"
and drive in the 4 wood
screws "A" (provided)
until tight.
4. Tighten 4 screws "B" in
fan housing to complete
installation.
Figure 2
2. Rest fan on window sill with flange on side panels over trim. Push in
side panels tight against outer edge of trim.
Figure 1
1. Loosen screws "B"
and extend side pan-
els to clear the outer
edge of trim on each
side of window.
METHOD A: (Outside of Trim)
Tools Required: Hardware Provided:
Screwdrivers Four - #8 x 3/4" slotted head screws
4. Mount fan in window
by engaging slots "C"
with screws "A" on
inside edge of trim.
Lower fan on screws
"A" until it rests on
window sill or sash
moulding.
Figure 5
5. Tighten screw "B" on
housing to secure
fan in position.
3. Loosen 4 screws "B"
and entend panels
on each side of
housing until the fan
fits snugly between
right and left window
trim.
Figure 4
Figure 6
Operation
This Air King® window fan is powered by a durable electrically-reversible
3 speed split capacitor motor. (Hi, Medium, and Low speed settings are
available for both intake and exhaust mode.) The motor control switch
is conveniently located on the motor cover. Adjust knob to direction and
speed desired.
CALIFORNIA RESIDENTS ONLY:
WARNING: This product can expose you to a chemical [or
chemicals] known to the State of California to cause cancer.
WARNING: This product can expose you to a chemical
[or chemicals] known to the State of California to cause
reproductive toxicity.
MAINTENANCE
WARNING: ALWAYS UNPLUG THE CORD
BEFORE MOVING OR SERVICING THE FAN.
WARNING:DO NOTIMMERSEFAN INWATER!
CLEANING: Use a soft cloth moistened with a mild
soapsolution, such as liquid dish washing detergent.
Dry ALL PARTS COMPLETELY before reassembling.
After any maintenance or servicing, COMPLETELY
REASSEMBLE unit as described in this instruction
manual before reconnecting to the power supply.
CAUTION: Do not use gasoline, benzine, thin-
ner, harsh cleaners, etc. as they will damage
theFan. NEVERuse ALCOHOLOR SOLVENTS.
LUBRICATION: Precision bearings are sealed at the
factory for life and will not require any further lubrication.
STORAGE: Store the Fan, with these instructions, in a cool, dry place.
DISPOSITION: Corrugated packaging materials are recyclable. For
environmentally responsible disposal of this product, contact your
local waste service provider or visit www.1800recycling.com®.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Cuando use este ventilador, se deben de seguir las siguientes advertencias y
precauciones para reducir el riesgo de incendio, descargas eléctricas y lesiones:
Lea todas las instrucciones antes de usar este Ventilador.
NO utilice este ventilador para ventilar las zonas donde se usen, almacenen o estén presentes líquidos o vapores inflamables, in-
cluidos pinturas, gasolina, barnices, disolventes o productos de acabado para pisos. ¡SIEMPRE lea y siga todas las advertencias
e instrucciones descritas en los envases de estos productos!
SIEMPRE asegúrese de que el enchufe encaje bien en el tomacorriente. Cuando los enchufes no encajan bien en el tomacorriente,
pueden deslizarse un poco y crear una mala conexión. Esto puede causar que los tomacorrientes se sobrecalienten y crear un riesgo
de incendio potencial. Un electricista calificado debe cambiar los tomacorrientes que se encuentren en esta condición.
SIEMPRE desenchufe el cable de corriente cuando realice mantenimiento, limpieza o mueva el ventilador. NO use el interruptor
ENCENDIDO/APAGADO (ON/OFF) como el único medio para desconectar de la electricidad. NUNCA deje a los niños sin supervisión
cuando el ventilador esté encendido o conectado.SIEMPRE apague y desenchufe el ventilador cuando no esté en uso.
ASEGURESE que la fuente de energía para el ventilador sea de 120 Vca . NO enchufe el ventilador en una fuente de energía de
240 Vca ni en ninguna otra fuente de energía que no sea la indicada.
El Blue Plug™ en su ventilador AirKing es una característica de seguridad. Contiene un dispositivo de seguridad no remplazable
(fusible) que no debe ser removido ni manipulado. Para reducir el riesgo de incendios, descargas eléctricas y lesiones, NO rem-
ueva, remplace, repare ni manipule el enchufe suministrado originalmente. Si el ventilador no funciona adecuadamente, puede
deberse al dispositivo de seguridad incorporado en este enchufe.
El cordón eléctrico está equipado con una clavija a tierra de tres espigas que tiene que ser enchufada a un receptáculo del mismo
diseño. Bajo ninguna circunstancia deberá cortarse la espiga a tierra de la clavija. De existir un receptáculo de pared de dos
espigas, deberá reemplazarse por uno de tres espigas debidamente puesto a tierra e instalado de conformidad con el Código
Nacional de Electricidad y todos los códigos y ordenanzas locales aplicables. El trabajo deberá hacerlo un electricista calificado,
utilizando exclusivamente alambre de cobre.
NO UTILICE UN ADAPTADOR DE TRES A DOS CLAVIJAS. LA CONEXIÓN INDEBIDA PODRÍA CREAR EL RIESGO DE SER ELEC-
TROCUTADO. EL USO DE TALES ADAPTADORES NO ESTÁ PERMITIDO EN CANADÁ.
PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS SIEMPRE SIGA LAS
SIGUIENTES INSTRUCCIONES Y ADVERTENCIAS:
PRECAUCIÓN
•EVITE el uso de cables de extensión, enchufes múltiples, triples, ambientadores eléctricos u otro dispositivo conectado por cables, ya
que estos dispositivos pueden sobrecalentarse y causar un riesgo de incendio.
•NO coloque los cables de alimentación debajo de alfombras, tapetes o muebles. Esto puede dañar el cable o causar que se
sobrecaliente y originar un riesgo de incendio
•SIEMPRE colocar el ventilador en una superficie estable, plana y nivelada mientras esté funcionando para evitar que el ventilador se caiga.
•NUNCA inserte ni permita que introduzcan los dedos u objetos en las aberturas de la parrilla del ventilador mientras este esté en funcio-
namiento, ya que el ventilador puede dañarse o malograrse.
•NO bloquee, cubra ni obstruya el flujo de aire hacia o desde el ventilador mientras esté en funcionamiento.
•NO utilice este ventilador al aire libre o cerca del agua o lugares húmedos como bañeras, piscinas o jacuzzis. El uso de este
ventilador en un lugar húmedo puede provocar una descarga eléctrica.
•NO cubra el cable de corriente con tapetes, alfombras estrechas o artículos de coberturas similares. No coloque el cable de corriente debajo
de muebles o artefactos. Coloque el cable de corriente lejos del tráfico de la habitación, donde las personas no se tropiecen con éste.
•NUNCA use un solo cable de extensión para hacer funcionar más de un ventilador u otro aparato eléctrico.
•NO use este ventilador si es que se ha dañado o si no funcione adecuadamente.
•ESTE VENTILADOR NO CUMPLE CON LOS REQUERIMIENTOS DEL ARTÍCULO 547-7 (2008) DEL NEC.Este ventilador no es
adecuado para su uso en instalaciones agrícolas, incluyendo las áreas donde el ganado, aves de corral u otros animales están
encerrados. Consulte el Artículo 547-7 (2008) del Código Eléctrico Nacional (NEC) o los códigos o normas locales o
estatales aplicables, relacionados con los requerimientos eléctricos para las instalaciones de agricultura.
•ESTE ARTEFACTO NO CUMPLE CON LOS REQUISITOS DEL ARTÍCULO 500 DEL NATIONAL ELECTRICAL CODE (Código Eléctrico
Nacional) 2008. Este ventilador no es adecuado para uso en lugares peligrosos. Consulte el Artículo 500 del Código Eléctrico
Nacional (NEC) o LOS CÓDIGOS O NORMAS LOCALES O ESTATALES APLICABLES, RELACIONADOS CON LOS REQUERIMIENTOS
ELÉCTRICOS PARA LOS SITIOS PELIGROSOS.
CONSERVE ESTAS INSTRUCCIONES
1/8" (3.2mm)
A
B
B
C
A
Slot
C
B
B
Slot
C
B
B
Slot
B
B
TEMPLATE
A
Rev. G 11/15 2082048A
4 Rev. G 11/15 2082048A
5
MODEL 2EJR6G/9155G MANUAL DE INSTRUCCIONES DE OPERACIÓN Y PARTES
VENTILADOR DE VENTANA de 40,64 cm
CON EXPULSION DE AIRE REVERSIBLE
MODELO 2EJR6G/9155G
Especificaciones
Motor............................................... 120V, 60Hz
Tamaño de paletas ......................... 16" (40,6 CM)
Velocidades .................................... 3 de entrada y 3 de salida
Control ............................................ Conjuntor rotatorio
Aprobaciones ................................. Catalogación ETL. El protector de malla
cerrada del ventilador satisface las normas OSHA.
Descripción
El ventilador de ventana Air King®tiene tres velocidades de entra-
da y tres de salida y puede instalarse en ventanas de 26 1/2" (67,3
cm) a 34 1/2" (87,6 cm) de ancho por 22" (55,9 cm) de altura. Sus
paneles laterales ajustables permiten que el ventilador pueda mon-
tarse ya sea por dentro o por fuera del contramarco de la ventana.
La unidad giratoria de 3 paletas, de 16" (40,64 cm), es accionada
por un motor permanentemente prelubricado con un cordón eléc-
trico de 6 pies (1,8 m), 18/3.
MODELO 2ERJ6G/9155G
VELOC. ALTA MED. BAJA
CFM 2470 1700 1360
M3/s 1.17 0.80 0.64
RPM 1480 1110 820
Amps 0.80 0.63 0.50
Watts 90 76 61
dB A 64 50 47
1
2
3
4
5
6
7
8
9
10
11
12
Knob
Switch plate
Screw, #8 x 5/8" HWH
Motor Cover
Screw, #6 x 5/8"
Inside guard
Cordset
Screw, #8 x 3/8" HWH
Motor cover brkt.
Switch
Motor
Side panel
1
1
9
1
6
1
1
1
1
1
1
2
2010115
02065209
*
2010609
*
02096025W
02050111A
2091169
2010703
2055052
02030116
2011815
13
14
15
16
17
18
19
20
21
22
23
Wood Screw, #8 x 3/4"
Screw, #10 x 3/4"
Speed nut, tinnerman
Body
Blade
Lockwasher, 1/4" ext. tooth
Nut, 1/4 -20 LH
Outside guard
Name plate
Lockwasher, #8 ext. tooth
Knob insert
4
4
4
1
1
1
1
1
1
1
1
REF
NO. DESCRIPTION PART
NO. QTY. DESCRIPTION
REF
NO. QTY.
*
2090005
2090006
2011805
2011227
*
2090124
2011215
02065508G
*
02070027
PART
NO.
Replacement Parts List
Figure 7 - Replacement Parts Illustration
(*) Standard hardware item, available locally
LIMITED WARRANTY
Air King PRODUCTS, INC. LIMITED WARRANTY
(VALID IN THE USA, ITS TERRITORIES, AND CANADA ONLY)
WHAT THIS WARRANTY COVERS: This product is warranted against defects in workmanship and/or materials.
HOW LONG THIS WARRANTY LASTS: This warranty extends only to the original purchaser of the product and lasts for one (1) year from the date of
original purchase or until the original purchaser of the product sells or transfers the product, whichever first occurs.
WHAT Air King WILL DO: Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product
with the same or comparable model. For all warranty claims, the product must be returned to Air King Products, Inc. at customer expense with proof
of purchase within the warranty period. Contact the Air King customer service department to obtain a Return Authorization (“RA”). DO NOT return
products without an RA or the warranty claim will not be processed.
WHAT THIS WARRANTY DOES NOT COVER: This warranty does not apply if the product was damaged or failed because of accident, improper handling
or operation, shipping damage, abuse, misuse, unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return
of products to Air King for repair or replacement. Air King will pay return shipping charges from Air King following warranty repairs or replacement.
ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY),
LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE
PRODUCT, WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL Air King’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE
(I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER, OR (II) REPLACMENT OR REPAIR OF ANY HOUSE FUSES,
CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO THE CONTRARY, IN NO EVENT SHALL Air King’S LIABILITY UNDER
ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON
THE EXPIRATION OF THE WARRANTY PERIOD.
Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential
damages, so these exclusions or limitations may not apply to you. This warranty gives you specific legal rights. You may also have other rights which
vary from state to state and province to province.
Proof of purchase is required before a warranty claim will be accepted.
LEA Y GUARDE ESTAS INSTRUCCIONES
LEA CUIDADOSAMENTE LAS INSTRUCCIONES ANTES DE INTENTAR
ARMAR, INSTALAR, USAR O DAR MANTENIMIENTO AL PRODUCTO
DESCRITO. PROTÉJASE A SÍ MISMO Y A LOS DEMÁS CUMPLIENDO
CON TODA LA INFORMACIÓN DE SEGURIDAD. EL NO SEGUIR LAS
INSTRUCCIONES PODRÍA RESULTAR EN LESIONES PERSONALES Y/O
DAÑOS A LA PROPIEDAD.
10 22
5
17
3
8
7
3
23
1
2
4
5
6
9
11
12
13
14 15
16
21
20
18
19

Other Air King Fan manuals

Air King Exhaust Fan AK80LS-1 AK80LS-1 User manual

Air King

Air King Exhaust Fan AK80LS-1 AK80LS-1 User manual

Air King AK863L User manual

Air King

Air King AK863L User manual

Air King AIF10X User manual

Air King

Air King AIF10X User manual

Air King 9842 User manual

Air King

Air King 9842 User manual

Air King AIDB4Y User manual

Air King

Air King AIDB4Y User manual

Air King AK100DH User manual

Air King

Air King AK100DH User manual

Air King AK130 User manual

Air King

Air King AK130 User manual

Air King 4DA35B/9102B Instructions for use

Air King

Air King 4DA35B/9102B Instructions for use

Air King 4CH64F/9018F Instructions for use

Air King

Air King 4CH64F/9018F Instructions for use

Air King DRLC707 User manual

Air King

Air King DRLC707 User manual

Air King 9518 Instructions for use

Air King

Air King 9518 Instructions for use

Air King 4CH63E/9119E User manual

Air King

Air King 4CH63E/9119E User manual

Air King AKLC701 User manual

Air King

Air King AKLC701 User manual

Air King AK80H User manual

Air King

Air King AK80H User manual

Air King AK100L User manual

Air King

Air King AK100L User manual

Air King AKSF40WT-D User manual

Air King

Air King AKSF40WT-D User manual

Air King FAS User manual

Air King

Air King FAS User manual

Air King AK150LS Series User manual

Air King

Air King AK150LS Series User manual

Air King 4TM65A Instructions for use

Air King

Air King 4TM65A Instructions for use

Air King AKF50 User manual

Air King

Air King AKF50 User manual

Air King 99532 User manual

Air King

Air King 99532 User manual

Air King PNP-150 User manual

Air King

Air King PNP-150 User manual

Air King AK150LS Series User manual

Air King

Air King AK150LS Series User manual

Air King Exhaust Fan AS60 User manual

Air King

Air King Exhaust Fan AS60 User manual

Popular Fan manuals by other brands

LUCCI Air AIRFUSION MARINER manual

LUCCI Air

LUCCI Air AIRFUSION MARINER manual

Casablanca Capistrano Owner's guide and installation manual

Casablanca

Casablanca Capistrano Owner's guide and installation manual

DOMOVENT Solo RA1-35-9 R user manual

DOMOVENT

DOMOVENT Solo RA1-35-9 R user manual

Aerovent IM-166 Installation, operation & maintenance manual

Aerovent

Aerovent IM-166 Installation, operation & maintenance manual

LTG FVS Eco2School Translation of Original Installation/Use/Maintenance Instructions

LTG

LTG FVS Eco2School Translation of Original Installation/Use/Maintenance Instructions

Overland Storage REO 9000 Remove & Replace Instructions

Overland Storage

Overland Storage REO 9000 Remove & Replace Instructions

Aquafog XE-2000 User's manual and operating instructions

Aquafog

Aquafog XE-2000 User's manual and operating instructions

Hansa HF-162 owner's manual

Hansa

Hansa HF-162 owner's manual

Monte Carlo Fan Company 5RH52 Series owner's manual

Monte Carlo Fan Company

Monte Carlo Fan Company 5RH52 Series owner's manual

Broan ULTRA SILENT QTXE150 Specification sheet

Broan

Broan ULTRA SILENT QTXE150 Specification sheet

Vortice VORT QUADRO MEDIO Instruction booklet

Vortice

Vortice VORT QUADRO MEDIO Instruction booklet

Bimar VSM11 Instruction booklet

Bimar

Bimar VSM11 Instruction booklet

Applica C163CM Use and care book

Applica

Applica C163CM Use and care book

Dantherm VentR Installation and service manual

Dantherm

Dantherm VentR Installation and service manual

Impecca FANFAIR FWF-1605 user guide

Impecca

Impecca FANFAIR FWF-1605 user guide

Home Decorators Collection HERITAGE POINT AM909-CB manual

Home Decorators Collection

Home Decorators Collection HERITAGE POINT AM909-CB manual

TCF TCPE Installation, operation & maintenance manual

TCF

TCF TCPE Installation, operation & maintenance manual

STIEBEL ELTRON LWA 252 Operation and installation

STIEBEL ELTRON

STIEBEL ELTRON LWA 252 Operation and installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.