User Manual
Specifications:- (tested with 8.0µm MCE filter)
Flow Range: Adjustable 1-3 litres / min
Flow Control: Variable potentiometer
Battery Pack: 9.6V 4/5A Cell(x8) NiMH 2Ah Recharge
Charge Time: Approx 4 hours
Duration: 8 hours
Display: Total run time
Material: 2.5mm aluminium
Coating: Epoxy powder resin resistant to minor damage.
Dimensions: H4.5cm x W 9.5cm x D13.0cm
Weight: 780g
PERSONAL MKII
Issue 1
220216
Airbox Sampling Products is part of the FermionX Group
Setting the flow
The flow is set from 1.0 litres/min to 3.0 litres/min by means of an electronic
control unit. This can be adjusted by turning the flow control screw found on the
underside of the unit (6)
Running
When the pump is switched on the timer will display the time elapsed in minutes.
When the pump stops, the timer will display the elapsed time. If the pump is
restarted, the timer will begin to count from the time at which it stopped.
Alternatively the display can be zeroed using the reset button (4).
Charging
Each pump comes with a voltage detecting battery charger. This is preset to give
500mA charge rate for sufficient time to recharge the battery pack.
At this rate the battery will be fully recharged from flat in approx 5 hours.
When the charger is plugged into the charging socket the red LED will be
illuminated.
When the battery is sufficiently charged the green LED will light. The charger can
be left connected for extended periods if required.
The charger also has a discharge facility built in which is triggered by the yellow
button at the front of the charger. Use of this is not essential but it can be used to
ensure a full discharge/charge cycle if required.
Our sampling pumps are designed to withstand the punishment of a long and
active working life. Internally the pumps contain a high efficiency, rotary vane
vacuum unit with a capacity of up to 3.0 litres/min of air through a standard 0.8
micron membrane filter.
1) On/Off switch
2) Timer
3) Air inlet
4) Time Reset
5) Red & Green LEDs
6) Flow Control
7) Charging Socket
1
6
3
5
00
4
2
7
Pump will not start, red LED illuminated. Battery voltage too low, recharge
battery.
Flow rate insufficient. Check motor speed control setting
and sample tube for kinks.
Pump stops while running, red LED
illuminated.
Battery voltage too low, recharge
or replace battery.
Pump fails to run for specified duration. Check battery pack.
Troubleshooting
Thank you for choosing this Airbox product. To ensure that you get the best
possible use from it, please read this manual carefully.
Technical support
For all technical support or customer service enquiries
please contact us:
Warranty Registration
Don’t forget to register your new Airbox product by filling in the registration form
provided and returning it to us at the address below.
Alternatively you can do this online at: www.airboxsp.com
telephone: +44(0)1903 524 600
email: [email protected]
Airbox Sampling Products , Technology Centre,
Easting Close, Worthing, West Sussex BN14 8HQ
User manual

Other Airbox Sampling Products Water Pump manuals

Airbox Sampling Products Personal MKII User manual

Airbox Sampling Products

Airbox Sampling Products Personal MKII User manual

Airbox Sampling Products DATAFLOW User manual

Airbox Sampling Products

Airbox Sampling Products DATAFLOW User manual

Airbox Sampling Products LOWFLOW User manual

Airbox Sampling Products

Airbox Sampling Products LOWFLOW User manual

Popular Water Pump manuals by other brands

EBARA EVM Series Operating and maintenance manual

EBARA

EBARA EVM Series Operating and maintenance manual

Roughneck 41763 owner's manual

Roughneck

Roughneck 41763 owner's manual

BUSCH COBRA NX 0450 A instruction manual

BUSCH

BUSCH COBRA NX 0450 A instruction manual

Graco BULLDOG HYDRA-CAT E Series Instructions-parts list

Graco

Graco BULLDOG HYDRA-CAT E Series Instructions-parts list

Cosmo C2PGRAC625NN Instructions for use

Cosmo

Cosmo C2PGRAC625NN Instructions for use

Columbia AA4VG71 instructions

Columbia

Columbia AA4VG71 instructions

Grundfos KPL Installation and operating instructions

Grundfos

Grundfos KPL Installation and operating instructions

Grundfos TPE 2 Series Installation and operating instructions

Grundfos

Grundfos TPE 2 Series Installation and operating instructions

T.I.P. MSC 3/3 M operating instructions

T.I.P.

T.I.P. MSC 3/3 M operating instructions

BRINKMANN PUMPS TVG400 Series operating instructions

BRINKMANN PUMPS

BRINKMANN PUMPS TVG400 Series operating instructions

Graco 233500 Instructions-parts list

Graco

Graco 233500 Instructions-parts list

Siccom SUNNY FLOWATCH DE05NCA050 instruction manual

Siccom

Siccom SUNNY FLOWATCH DE05NCA050 instruction manual

Peerless Pump THF Installation, operation and maintenance

Peerless Pump

Peerless Pump THF Installation, operation and maintenance

Orion 22750 user manual

Orion

Orion 22750 user manual

Clarke DW75 Operation & maintenance instructions

Clarke

Clarke DW75 Operation & maintenance instructions

Ecolab Elados EMP E60 Series Short operating instructions

Ecolab

Ecolab Elados EMP E60 Series Short operating instructions

Grundfos Unilift APG Safety instructions and other important information

Grundfos

Grundfos Unilift APG Safety instructions and other important information

Lowara GLS Series Installation, operating and maintenance instructions

Lowara

Lowara GLS Series Installation, operating and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.