6 Technical data
6.1 Shaft Seals
The correct function of a mechanical seal is largely dependent upon its lubrication and cooling of the sealing surfaces. It is
therefore extremely important to avoid any dry-running of the seal faces since this can cause excessive generation of heat and
thus the possibility of exceeding the specified temperature class. During normal operation a mechanical seal will generate a very
small but controlled leakage which will increase upon failure. If dry-running of the process media cannot be avoided or if any
leakage of the process media can cause a hazardous situation (i.e. flammable media), a flush system must be fitted.
The standard ATEX compliant mechanical seal options are described below:
A. Double Flushed Mechanical Seal
This seal arrangement provides the user with the highest level of protection against the seal faces running hot. On this
seal arrangement the flush is used as a ‘Barrier’ fluid. The pressure of the barrier fluid should be 1.0 bar min. above the
pump discharge pressure. The inboard seal interface film will therefore be flush media. The barrier fluid will act as a coolant
and lubricant for both inboard and outboard seals. Leakage of pumped media into the barrier fluid will not occur. Flush
housings should be connected in series (not parallel). Proper function of the flush system is essential - if the flush flow is
interrupted or stopped the outboard seal will run dry and the seal face temperature increased to become a potential
explosion risk, see section 6.2
A double mechanical seal fitted with a thermocouple, section 6.3.5, allows the user to provide alarms based on the temperature
at the seal face, see section 6.2
Thermosyphon flush systems are not recommended.
B. Single Flushed Mechanical Seal
This seal arrangement provides the user with a high level of protection against the seal faces running hot.
On this seal arrangement the flush is used as a ‘Buffer’ fluid. The pressure of the buffer fluid should be 0.5 bar max.
The seal interface film will therefore be pumped media. The buffer fluid will act as a coolant for the seal and prevent the
pumped media from coagulating, solidifying or crystallising on the seal faces. Any leakage of pumped media is carried
away to ensure good seal function. Flush housings should be connected in series (not parallel). Proper function of the flush
system is essential - if the flush flow is interrupted or stopped the seal will run dry and the seal face temperature increased to
become a potential explosion risk, see section 6.2
Note: A double flushed mechanical seal can also be operated in a low pressure flush mode as above.
C. Single Mechanical Seal
On this seal arrangement the seal interface film is the pumped media. The pumped media acts as a coolant and lubricant for
the seal faces. For single mechanical seals without a thermocouple fitted there is no monitoring device or protection and
relies on the process media to cool and lubricate the seal faces to stay within the stated temperature class. The process
must be controlled / monitored to ensure the seal faces do not exceed the temperature limit. This can be achieved by
ensuring there is a reasonable flow of the process media and the process temperature does not exceed the values listed in
the ‘Seal Operation Data’, section 6.3.
A single mechanical seal fitted with a thermocouple, section 5.3.2, allows the user to provide alarms based on the temperature
at the seal face, see section 6.2
6.2 Monitoring Seal Face Temperature
It must be ensured that the temperature of the seal face does not exceed the temperature class limit. This can be achieved by:
A. Ensuring that the temperature measured locally at the seal face does not exceed the temperature listed in the ‘Seal
Operation Data’, section 6.3, e.g. with a thermocouple fitted to the stationary seal ring.
B. For double and single flushed mechanical seals only, ensuring the barrier / buffer fluid temperature does not exceed the
value listed in the ‘Seal Operation Data’, section 6.3, and the total flow is a minimum of 30 l/hr. The temperature and
flow must be measured after the flush housing outlet. If a recommended flow higher than 30 l/hr is stated on the ‘Seal
Operation Data’, this should be adhered to.
C. For double and single flushed mechanical seals only, ensuring the barrier / buffer fluid temperature does not exceed the
value listed in the ‘Seal Operation Data’, section 6.3, and the total flow is sufficient to reach the temperature sensor within 10
seconds after leaving the flush housing outlet. The distance between the flush housing outlet and the temperature sensor
should not exceed 200mm. This applies when the barrier / buffer flow is lower than 30 l/hr.
19