manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ALIBI
  6. •
  7. Voice Recorder
  8. •
  9. ALIBI ALI-QVR4008H Series User manual

ALIBI ALI-QVR4008H Series User manual

1ALI-QVR40xxH_SQ
180305
Item Description
1 VIDEO IN BNC connectors for camera video channels in. Number of channels is dependent on the model of the DVR.
2VIDEO OUT CVBS
3AUDIO IN RCA connector for audio in cable.
4 ON / OFF switch Switch for powering the DVR on and o
5USB Use for a USB mouse or USB memory device such as a ash drive or DVD burner. A USB port is also located on the front panel.
6HDMI Connector HDMI monitor cable.
7VGA Connector VGA monitor cable.
8AUDIO OUT RCA connector for audio out cable.
9LAN RJ-45 connector for Ethernet drop cable.
10 RS-485 terminations Connector for RS-485 devices. Connect the D+ and D- terminals to T+ and T- of PTZ receiver respectively.
11 12 Vdc Plug for 12 Vdc power adapter (provided).
12 Alarm terminations See Alarm terminations below.
13 GND terminal Ground terminal post.
Alarm terminations
Item Description
RS-485 (D+, D-) D+ and D- pins connect to R+ and R- pins of PTZ receiver respectively.
For cascading devices, the rst DVR’s D+, D- pin should be connected with the D+, D- pin of the next DVR.
ALARM IN Alarm inputs (ALI-QVR4008H: 1 .. 8, ALI-QVR4016H: 1 .. 16). Alarm input is tied to ground through the alarm sensor. See “Step 3. Connect
alarm devices to the DVR” on page 2.
ALARM OUT
(1-G through 4-G) Alarm outputs 1 - 4 with ground terminations. See “Step 3. Connect alarm devices to the DVR” on page 2.
Mouse control
A standard 3-button (left / right / scroll-wheel) USB mouse can also be used with this DVR. To use a USB mouse:
1. Plug the USB mouse into the either the front panel or back panel USB connector of the DVR.
2. The mouse will be automatically detected. If the mouse is not detected, the mouse may not be compatible with the DVR. Please refer
to the recommended device list from your provider.
This guide provides instructions to initially setup the ALI-QVR4000H series digital video recorder (DVR) for AHD, HD-TVI, analog and IP
cameras. The ALI-QVR4008H DVR supports up to 8 analog cameras plus 2 IP cameras (10 total). The ALI-QVR4016H DVR supports up to
16 analog cameras plus 2 IP cameras (18 total). For information about using your DVR and its extensive capabilities, refer to the ALIBI
Embedded Network Video Recorder Firmware V3.4.x User Manual provided at www.alibisecurity.com/resources.
For more information, refer to these documents - available from your equipment vendor:
• ALIBI™ Tools Utility Installation and User Manual
• ALIBI™ Witness Smartphone App - Quick Start Guide
DVR Front Panel
USB Interface
Power LED
Status TX / RX
ALI-QVR4008H, ALI-QVR4016H front panel
Item Usage
Power LED Indicator turns green when DVR is powered up.
Status STATUS indicator lights in red when HDD is reading / writing.
TX / RX LED indicator blinks green when network connection is functioning properly.
USB Interface This port can be used for a USB mouse or USB ash memory devices.
DVR Back panels
1 2 34
1312
11
10
98765
ALI-QVR4008H backpanel
1 2 3 4
1311 121098765
ALI-QVR4016H backpanel
ALI-QVR4000H Series 8/16-Channel AHD, HD-TVI, Analog and IP Camera Recorder Quick Setup Guide
2www.Observint.com © 2016, 2017, 2018 Observint Technologies. All rights reserved.
Step 2. Install the DVR
For the following steps, refer to the back panel photo above for the location of connectors.
1. Place the DVR in a location that is secure, well ventilated and clean. The DVR should be positioned such that the back panel connectors
are accessible and the ventilation holes on the sides are not blocked.
2. Connect the ground terminal on the back of the DVR to an earth ground. Refer to local codes for proper grounding.
Step 3. Connect alarm devices to the DVR
Wiring alarm inputs to the DVR
You can wire up to 8 alarm inputs to the DVR. Alarm input wiring connects to the RS-485, Alarm IN / OUT connector blocks on the back of the
DVR.
Alarm In sensor (N.O. or N.C.)
Typical ALARM IN wiring
Wiring alarm outputs to the DVR
The DVR provides 4 alarm output terminations. These terminations for each output are on the ALARM OUT connector block on the back of the
DVR , and are labeled 1 - G, 2 - G, 3 - G, 4 - G (G = ground termination).
There are 4 jumpers (JP1, JP2, JP3, and JP4) inside the chassis on the alarm termination PC board, associated with ALARM OUT pins 1, 2, 3
and 4 respectively. Initially, these jumpers are in place. If connecting an alarm output to a DC loaded alarm out circuit, the jumper must be in
place. If connecting the alarm output to an AC loaded alarm, the corresponding jumper must be removed. Example: If you connect an AC load
to the alarm output 3 of the DVR, then you must remove the JP 3.
To remove a jumper for AC load alarm circuits:
1. Disconnect all cabling from the DVR.
2. Remove the DVR top cover: Remove the two cover screws on the back of the chassis, the slide the cover toward the back until it is free.
3. Locate the jumper associated with the alarm output you are using for an AC load alarm, then remove it. Save the jumper for use later,
if needed.
4. Reinstall the DVR top cover.
Using the mouse
Action Eect
Left click
Single click: Live view: Select channel and show the quick set menu.
Menu: Select and enter.
Double click: Live view: Switch between single-screen and multi-screen.
Click and drag: PTZ control: pan, tilt and zoom.
Tamper-proof, privacy mask and motion detection: Select target area.
Digital zoom-in: Drag and select target area.
Live view: Drag channel / time bar
Right click Live view: Show menu.
Menu: Exit current menu to upper level menu.
Scroll wheel
Scroll up: Live view: Previous screen.
Menu: Previous item.
Scroll down: Live view: Next screen.
Menu: Next item.
Installing the System
Step 1. Getting Started: Unpacking the Equipment
What’s in the box
Your system includes:
• ALI-QVR4000H Series DVR
• USB mouse
• HDMI cable
• Power adapter for DVR
• This Quick Start Guide
Remove the equipment from its packaging and place it on a at, clean surface. Inspect each item. If any visible damage is present, contact
your supplier for a replacement. Verify that your order is complete.
What you need
Although each security system installation is dierent, most require the following items not included with your system components:
• Cameras and cables compatible with the DVR. The Video in ports on the back panel support most analog CCTV camera brands and Alibi
HD-TVI, AHD, analog or IP cameras
• IP cameras installed on the Ethernet network (LAN) that associated with the DVR must be Alibi IP cameras.
• Tools to install the cameras and route power and video cables
• Fasteners to attach the cameras to the mounting surfaces
• VGA or HDMI compatible computer monitor to connect to the DVR. (An HDMI cable is provided.)
• Uninterruptible power supply (UPS) is recommended. This device is used to ensure system stability during voltage surges, sags, and
outages. If a UPS is not available, a power strip with strong surge protection is highly recommended.
3www.Observint.com © 2016, 2017, 2018 Observint Technologies. All rights reserved.
2. Power on your cameras.
3. Power on the DVR using the power on / o (I / O) switch on the back panel.
4. Power on the monitor.
NOTE Some monitors have multiple inputs such including VGA ,HDMI, BNC, etc. If you are using this kind of monitor, congure your monitor to
display the input connected to your DVR (HDMI or VGA).
Step 7. Using the Wizard for basic configuration setup
Power on the DVR. Normally, an Alibi logo splash screen appears within 2 minutes.
By default, the Setup Wizard will open automatically. Refer to the ALIBI Embedded Network Video Recorder Firmware V3.4.x User
Manual for incomplete instructions for using the Wizard and conguring and using your DVR.
Important Notes for using the Wizard:
• Password: When logging into the recorder for the rst time, create a “Strong” administrator user password. Follow the on-screen
instructions, and save this password and the GUID le created by the rmware in a secure location. NOTE: There is no factory default
password for this device.
• Date and Time: Set the time zone, date and time correctly. All recorded video and capture (photo) les are time stamped.
• Storage - HDD: In the HDD Management wizard, if a new recorder is shipped with a pre-congured HDD, nothing needs to be done
with it in this window. If you installed an HDD or replaced the HDD, that HDD needs to be initialized by the recorder before it can be used
to record data. Select (check the box for) that HDD, then click Init to initialize the disk. NOTE: Init will erase all data from the disk and
can take several minutes to complete. When the initialization is complete, click Next to continue.
• Network Settings: By default, the recorder acquires it’s network settings using DHCP (dynamic network settings). Depending on the
conguration of the network, these settings may change. To improve remote access to the recorder, Observint recommends that you
congure the DVR with xed network settings. To easily change the DHCP acquired network settings to xed network settings,
un-check the Enable DHCP option in the network setup menu, and then click Apply.
DC load alarm output circuits
DC loads must operate within the limitation of 12V / 1A. To connect to a DC alarm output, use the following diagram:
DVR
DC Load
AC load alarm output circuits
To connect an AC load to an alarm output, a jumper, associated with the output on the alarm termination PC board, (within the chassis), must
be removed. These jumpers shunt pin pairs J1, J2, J3, and J4 for alarm outputs 1, 2, 3, 4 respectively. Use an external relay for safety.
DVR
Step 4. Install a monitor, mouse, power
For the following steps, refer to the back panel photo above for the location of connectors.
1. Install and setup your monitor in accordance with the instructions provided with the monitor. Do not power it on at this time.
2. Cable the HDMI or VGA connector to your monitor’s VGA or HDMI input. The HDMI interface provides the best performance.
3. Plug the mouse into the USB connector on the front or back of the DVR.
4. If you plan to access your DVR remotely, or congure your DVR to transmit alerts, email, etc. to external servers, plug a drop cable from
your local area network (LAN) into the RJ45 LAN connector on the back of the DVR.
5. Connect the power cord to the power connector on the back panel of the DVR, and then into a UPS (recommended) or surge protector.
Step 5. Install cameras
Install your security cameras. Always follow the installation instructions provided with the camera. Refer to the Specications section on
page 4 for supported camera types.
Step 6. Connecting it together – initial system setup
1. Plug the coaxial cables from the cameras into the BNC camera input connectors on the back of the DVR.
4www.Observint.com © 2016, 2017, 2018 Observint Technologies. All rights reserved.
Model ALI-QVR4008H ALI-QVR4016H
Audio input 4-ch, RCA (2.0 Vp-p, 1 KΩ)
CVBS output Supported
HDMI / VGA output
VGA: 1-ch, 1920 × 1080 / 60 Hz, 1280 × 1024 / 60 Hz, 1280 × 720 / 60 Hz, 1024 × 768 / 60 Hz
HDMI: 1-ch, 4K (3840 × 2160) / 30 Hz, 2K (2560 × 1440) / 60 Hz, 1920 × 1080 / 60 Hz, 1280 × 1024 / 60 Hz, 1280 × 720 / 60 Hz,
1024 × 768 / 60 Hz
Encoding resolution 3MP@15 fps / 1080p / 720p / 960H / 4CIF / VGA / CIF
Frame rate
Main stream: 25 fps (P) / 30 fps (N)
Sub-stream: 960H / 4CIF@12 fps (non-real-time); CIF / QVGA / QCIF (real time)
Video bitrate 32 Kbps to 10 Mbps
Audio output 1-ch, RCA (Linear, 1 KΩ)
Audio bit rate 64 Kbps
Dual-stream Supported
Stream type Video, Video and Audio
Synchronous playback 8-ch 16-ch
Remote connections 128
Network protocols TCP / IP, PPPoE, DHCP, DNS, DDNS, NTP, SADP, NFS, iSCSI, UPnP™, HTTPS, ONVIF
SATA 2 SATA interfaces (2 HDDs max)
Capacity Up to 6TB capacity per HDD
Two-way audio input 1-ch, RCA (2.0 Vp-p, 1 KΩ) (using the audio input)
Network interface 1 × RJ45 10M / 100M / 1000M self-adaptive Ethernet interface
USB interface 2 × USB 2.0
Serial interface 1 × RS-485 serial interface, half-duplex
Alarm in / out 8 / 4 16 / 4
Power supply 12 Vdc
Consumption (without HDD) ≤ 20 W
Working temperature 14 ºF to 131 ºF (-10 ºC to +55 ºC)
Working humidity 10% to 90%
Dimensions (W × D × H) 15.0 × 12.6 × 1.9 in (380 × 320 × 48 mm)
Weight (without HDD) ≤ 2 kg (4.4 lb)
Step 8. Access the Menu system
After the initial setup of your QVR using the Wizard, the Menus interface enables you to rene your conguration settings and expand the
functionality of the system. To use most menus, the user must log into the NVR system, either locally or remotely, with administrative
privileges. To open the Menu system from the Live View screen, right click anywhere in the screen, then select Menu.
If ID Authentication is not disabled (see the Menu | Conguration | General settings), a login window will open. In the Login window,
select a User Name with administrative privileges, enter its password, then click OK. A window of Menu icons will open.
For additional information about using your system, refer to the ALIBI Embedded Network Video Recorder Firmware V3.4.x User
Manual.
Specications
Model ALI-QVR4008H ALI-QVR4016H
No. cameras supported
Up to 8 analog, HD-TVI and or AHD cameras at BNC video inputs Up to 16 analog, HD-TVI and or AHD at BNC video inputs
Up to 2 Alibi or ONVIF IP cameras up to 4 MP each on network Up to 2 Alibi or ONVIF IP cameras up to 4 MP each on network
Video input
8-ch 16-ch
BNC interface (1.0 Vp-p, 75 Ω), supporting coaxitron connection
Supported HDTVI input 1080p / 25 Hz, 1080p / 30 Hz, 720p / 25 Hz, 720p / 30 Hz, 720P / 50 Hz, 720p / 60 Hz, 3MP, 5MP
Supported AHD input 720p / 25 Hz, 720p / 30 Hz
CVBS input Supported
Video compression H.264 OVC / H.264
Audio compression G.711u

This manual suits for next models

1

Popular Voice Recorder manuals by other brands

Tascam AUDIO RECORDER Instructions for use

Tascam

Tascam AUDIO RECORDER Instructions for use

futuredesion DR 5000 user manual

futuredesion

futuredesion DR 5000 user manual

Olympus DS-2400 manual

Olympus

Olympus DS-2400 manual

Marantz professional PMD580 Service manual

Marantz professional

Marantz professional PMD580 Service manual

Reflexion HIF1970BT user manual

Reflexion

Reflexion HIF1970BT user manual

Olympus DM-5 Detailed instructions

Olympus

Olympus DM-5 Detailed instructions

Sony HDW-S280 manual

Sony

Sony HDW-S280 manual

Philips VTR6000 manual

Philips

Philips VTR6000 manual

Sony ICD-PX333M quick start guide

Sony

Sony ICD-PX333M quick start guide

Sony ICD-SX68DR9 Specifications

Sony

Sony ICD-SX68DR9 Specifications

Sony ICD-AX412F operating instructions

Sony

Sony ICD-AX412F operating instructions

Black Box TE110A Specifications

Black Box

Black Box TE110A Specifications

UltraDisk DVR 1 user manual

UltraDisk

UltraDisk DVR 1 user manual

SpyCameraCCTV SPYDV90 Product guide

SpyCameraCCTV

SpyCameraCCTV SPYDV90 Product guide

Smart Witness CP4 installation guide

Smart Witness

Smart Witness CP4 installation guide

Sony Voice File ICD-55 Service manual

Sony

Sony Voice File ICD-55 Service manual

Panasonic RR-US350 operating instructions

Panasonic

Panasonic RR-US350 operating instructions

Tascam DR-100MKIII Reference manual

Tascam

Tascam DR-100MKIII Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.