Digital Linear Scale User Manual
Part No: AE-MAN-DS
Doc V: 1.0
Digital Linear Scales
•Beforeusingthelinearscaleforthersttime,wipewithacleanclothideallysoakedwithcleaningoil.
•Thescaleisaprecisionmeasuringinstrument.Avoidusingexcessiveforce,andtreatwithcare.
•Thettedbatteryisintendedforthefactorytestprocedureandthereforemaynotmeetthespeciedbatterylife.
•Avoidexposuretoallliquids,excessivehumidityortemperature.
•Avoidexposuretobrightsunlight.
•Neverapplyvoltageonanypartofthislinearscaleorelectricengrave.
•Removethebatteryifthescaleisnotbeingusedforalongperiodoftime.
•Neverusesolventstoclean.Onlyuseasoftclothwithcleaningoil.
•Ensurethelinearencoderismountedparallelandcorrectalignmentofthereadinghead.
Precautions
Battery Replacement
2
3
6
1
5
7
1
5
4
3
6
2
8
8
0
5
10
15
20
25
30
35
40
45
7
4
Linear Digital Scale
1. Slide open the battery cover.
8. Insert the two lugs on the
cover.
9. Gently lower battery cover.
2. Lift battery cover front edge.
3. Remove cover.
4. Remove battery (a magnet tip
tool can be used).
5. Locate side spring contact.
6. Insert replacement battery
edge against side contact.
7. Press down on other edge.
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
10. Pull battery cover outward
sightly
11. Fully lower cover
1
2
3
4
5
6
7
8
9
10
11
12
12. Slide battery cover fully
closed.
1
2
3
4
5
6
7
8
9
10
11
12
Magnet
tipped
tool
Positive (+)
side up
2
3
6
1
5
7
1
5
4
3
6
2
8
8
0
5
10
15
20
25
30
35
40
45
7
4
TheLinearscalemustbealigned
paralleltothemachinetravel.Usea
dialgaugeorDTItosetparallel.
Thetravelofthereadingheadmust
alsobealignedcorrectlytothescale
beam,otherwisedamagewilloccur.
1.Beamclamp.
2.Beam.
3.Readinghead.
4.LCDdisplay.
5.Functionbutton.
6.Batterycover.
7.Dataoutputcover.
8.Readingheadxing.
Horizontal Type
Vertical Type
© Allendale Group
© Allendale Group © Allendale Group
© Allendale Group
© Allendale Group
© Allendale Group © Allendale Group
© Allendale Group
machine-dro.co.uk
www.machine-dro.co.uk - Allendale Electronics Ltd, Pindar Road, Hoddesdon, Hertfordshire. EN11 0BZ.
Images & Content ©2010 Allendale Electronics Limited. E&OE - Specifi cations subject to change without prior notice.
Digital Linear Scale User Manual
Trouble Shooting
Metric/Inch conversion
25.40
mm
mm/inch

Pressmm/inchtoconvert
frommetrictoinchdisplay.
1.000
Thedisplaywillindicate
whichunitsarebeing
displayed.
mm/inch

in
Scale with ABS Function (not available on all models)
0.00
mm
Zero

PressZERObutton.
30.00
mm
Travelthereadinghead,for
example 30mm
20.00
mm
ABS

PressABSbuttontoswitchto
incremental.Travelthereading
headfor example 20mm.
50.00
mm
ABS

PressABStoswitchback
toAbsolutedisplay.Total
distance traveled from zero.
mm
Scale with Preset Function (not available on all models)
0.00
mm
SET

PressandholdtheSET
button.(IfnoSETbuttonpress
andholdZERO)

SET 20.00
mm
pre+

Pressarrowbuttonsto
increase&decreasevalue.
ReleaseSETbutton.Press
SETdisplaytothepreset.

SET 20.00
mm


Pressupordownarrow
buttonstoincrease&
decreasedisplayvalue.

Zero Display
0.00
mm
ZERO

Press zero to clear
Problem PossibleCause Solution
Flashingdisplay Lowvoltage
Poor contact
Replace battery
Clean contact
Nodisplay Deadorweakbattery
Poor contact
Replace battery
Clean contact
Nochangetodisplay Internalerror
"H"shownondisplay
Remove battery for 1 hour
Remove battery for 5 minutes
Can't zero Holdfunctionactive
Tolerancefunctionactive
Switch off function
Switch off function
Erraticorfrozendisplay Contaminationbetweenbeam&head
lowvoltage
Wipe clean
Replace battery
Erroneousreading Lowvoltage
Contaminationbetweenbeam&head
Scalenotparalleltotravel
Lowambienttemperature
Replace battery
Wipe clean
Adjust parallel with dial gauge/DTI
Store at normal room temperature
INC
Vertical Scale Preset Function
19.80
mm

1
2
3
5
4
6
1
2
3
5
4
6
1
2
3
5
4
6
Positive (+)
side up
Magnet
tipped
tool
Side Type Cover
1. Slide open the battery cover.
2. Remove battery. (a magnet tip
tool can be used).
3. Locate side spring contact.
4. Insert replacement battery
edge against side contact.
5. Press down on other edge.
6. Slide battery cover closed.
Releasearrowbuttonwhen
desiredvalueisdisplayed.

© Allendale Group © Allendale Group © Allendale Group

Popular Measuring Instrument manuals by other brands

KROHNE OPTISYS TUR 1060 Handbook

KROHNE

KROHNE OPTISYS TUR 1060 Handbook

Hanna HI759 Quick reference guide

Hanna

Hanna HI759 Quick reference guide

Nidec PG-100B Series instruction manual

Nidec

Nidec PG-100B Series instruction manual

Hanna Instruments edge DO manual

Hanna Instruments

Hanna Instruments edge DO manual

Sunje Hi-Tek SPE-100 instruction manual

Sunje Hi-Tek

Sunje Hi-Tek SPE-100 instruction manual

Siemens VDO modulcockpit II product manual

Siemens

Siemens VDO modulcockpit II product manual

Interface BlueDAQ BX8 quick start guide

Interface

Interface BlueDAQ BX8 quick start guide

MFJ MFJ-868B manual

MFJ

MFJ MFJ-868B manual

Kirchner und Tochter RA 77 Installation and operating instructions

Kirchner und Tochter

Kirchner und Tochter RA 77 Installation and operating instructions

National Instruments PXI-5663 CALIBRATION PROCEDURE

National Instruments

National Instruments PXI-5663 CALIBRATION PROCEDURE

Geosense WI-SOS 480 instruction manual

Geosense

Geosense WI-SOS 480 instruction manual

micro-trak SPEED-O-METER 13347 Installation & operator's manual

micro-trak

micro-trak SPEED-O-METER 13347 Installation & operator's manual

Chemglass CG-1872-M-20 Operation manual

Chemglass

Chemglass CG-1872-M-20 Operation manual

Raycan RadTarge-Mini user manual

Raycan

Raycan RadTarge-Mini user manual

Novalynx 255-110-B Series user manual

Novalynx

Novalynx 255-110-B Series user manual

EHP TELEBOX PLC Technical manua

EHP

EHP TELEBOX PLC Technical manua

Murphy Temperature Scanner/Pyrometer SWICHGAGE TDX6 Specifications

Murphy

Murphy Temperature Scanner/Pyrometer SWICHGAGE TDX6 Specifications

Thermo Scientific Orion Star Plus quick start guide

Thermo Scientific

Thermo Scientific Orion Star Plus quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.