ÎÈäÎÎÊ,iÛ°Êä®ÊUÊ`Ê`ÊÀ«Ê7iÊ"«iÀ>ÌÊEÊ>ÀiÊ>Õ>ÊUÊ{
SITE INSTALLATION
1. The cold well must be installed on a stable and
level surface - free of vibration and suitably
strong enough to support the combined weights
of the unit plus the maximum product load
weight.
2. DO NOT install this appliance in any area
where it may be affected by any adverse
conditions. Avoid placing the unit in direct
sunlight, near heat generating equipment
such as ovens, ranges, heaters, fryers, steam
kettles, dripping water, high temperatures, or
any other severely adverse conditions. Avoid
locating in an unheated room or where the room
temperature may drop below 55°F (13°C) or
above 86°F (30°C).
3. Once the drop in unit is installed into the
counter it can be secured to the counter top by
using the brackets supplied.
a. Locate square openings on exterior body of
drop unit. Insert securing bracket as shown.
Tighten screw to anchor the unit tightly to
cabinet top.
b. Seal top flange to the counter top by using
food grade silicone sealant.
4. The air cooled self contained units require
a sufficient amount of cool clean air. The
mechanical housing (except on 100-CW
appliances) can be rotated so that the condenser
intake air can be in direct line with the cabinet
fresh air opening.
a. Loosen wings nuts located under cold pan
body and rotate carriage to desired location.
b. Tighten wing nuts when rotation is complete.
c. Loosen wing nuts on each side of condenser
shroud and extend to fresh air opening.
d. Tighten wing nuts on each side of condenser
shroud.
Cross ventilation in the cabinet is recommended
to maintain ambient temperature 86°F (30°C) or
less.
5. DO NOT store or use any flammable liquids or
allow flammable vapors in the vicinity of this
appliance or any other appliance.
6. This appliance must be kept free and clear of
any combustible materials.
LEVELING
The cold well
should be
leveled before
the electrical supply is
connected. Level the appliance from side-
to-side and front-to-back with the use of a spirit
level.
NOTE
It is important to apply a food grade silicone
underneath the decor flange to seal flange to
the counter top.
INSTALLATION