- 2 - R2416220 Series Installation Guide
Installation Instructions:
1. The unit is factory set for 24VAC operation.
For 28VAC operation, adjust unit prior to mounting and applying power as follows:
a. Open bottom of the unit by removing six (6) screws (Rack Mechanical Drawing & Dimensions, pg. 4).
b. Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and
the yellow wire [24V] is connected to the terminal marked [S] (Fig. 1e, pg. 3).
c. After securing all wires for proper voltage place bottom panel back on the unit and fasten with the six
(6) screws.
2. Mount unit in the desired rack location (Space unit at least 3” from any video monitors).
Do not obstruct side air vents.
3. Set power switch on the back of unit to the OFF position (Fig. 1c, pg. 3).
4. Plug power cord into a grounded 220VAC, 50/60 Hz receptacle (Fig. 1b, pg. 3), ground should be connected
as indicated in (Fig. 1d, pg. 3).
5. Set power switch on the back of the unit to the ON position and measure output voltage before connecting
devices (Fig. 1c, pg. 3). This helps avoiding potential damage.
6. Set power switch on the back of the unit to the OFF position (Fig. 1c, pg. 3).
7. Connect devices to the removable terminal blocks marked [1P & 1N through 8P & 8N] (Fig. 1a, pg. 3).
When wiring is completed on terminal blocks they can be locked down by tightening screw flanges.
8. Upon completion of the wiring, set power switch on the back of the unit to the ON position (Fig. 1c, pg. 3).
9. Green power LEDs on faceplate will illuminate when AC power is present. When an output is in a trouble
condition (blown fuse or tripped PTC) the corresponding LED will not be illuminated (Fig. 1, pg. 3).
a. Blown fuse (R2416220, R2416300220, and R2416600220) - Set power switch on the back of the unit
to the OFF position (Fig. 1c, pg. 3). Remove front faceplate to access fuses.
Replace with fuses rated @ 3.5A/250VA (Altronix model # Fuse1).
Agency Listings:
• CE European Conformity.
Input:
• 220VAC, 50/60Hz.
Output:
• Sixteen (16) fuse or PTC protected outputs.
• 24VAC or 28VAC supply current.
• Outputs are rated @ 3.5A (fuse) or 2.5A (PTC).
• Surge suppression.
Visual Indicators:
• Sixteen (16) individual power LED indicators.
• Illuminated power disconnect circuit breaker
with manual reset.
Features:
• Unit maintains camera synchronization.
• Ease of installation saves time and eliminates
costly labor.
• Removable terminal blocks with locking
screw flanges.
Rack Dimensions (H x W x D):
• 2U rack mount chassis for use in standard
EIA 19” rack.
3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm)
Overview:
Altronix R2416220 Series Rack Mount CCTV Power Supplies provide 24VAC or 28VAC distributed via sixteen (16)
fuse or PTC protected outputs for powering CCTV cameras, heaters and other video accessories.
Sixteen (16) Output Rack Mount Configuration Reference Chart:
Altronix
Model Number
Output
Voltage
(VAC)
Total
Output
Current
(Power)
Number
of
Outputs
PTC
Protected
Outputs
(auto-
resettable)
Fuse
Protected
Outputs
Output
Current
(max per
output)
220VAC
50/60Hz
Input
Current
R2416220 24 8A 16 – P3.5A 1A
28 7A
R2416CB220 24 8A 16 P– 2.5A 1A
28 7A
Specifications: