SPECIFICATIONS
www.americandynamics.net
(2) Input voltage greater than 36 VDC or AC may damage equipment
(3) The network distance shown is the total distance per ADACSNETD driver. The panel contains 16 drivers labeled 1 through 16 and each driver has two physical connectors on the front panel. If only one of the two connectors is used, the full
distance can be applied to that connector. If both of the connectors are being used, the combined distance should not exceed the amount shown.
Model Numbers
ADACSNETD .............No external power module
ADACSNETDP ............Includes external power module
Physical
Dimensions (L x W x D)......481 x 87 x 34 mm (18.9 x 3.4 x 1.3 in)
Weight ..................0.75 kg (1.66 lbs)
Mounting ................19-inch EIA / IEC rack mount (2U)
Electrical
Power Source.............External power module: 27 VA North American
(able to power three units)
International 45 VA (able to power five units)
Input....................12 to 30 V, DC or AC, isolation not required
Certified limited power source
NEC Class 2
Power Consumption........8 VA
Indicators: Power On .......Green LED
Noise Detect..............Red LED
Host A and B Receive Data . .Yellow LED
Channels 1-16 Receive Data . Yellow LED
Protection................Internal primary current fuse
Inrush limiting
DC isolation
Surge Protection...........Transguard rated at 60 V, 250 A, 1.5 J
Gas discharge tube, impulse rated at 10 kA
Design Tolerance ..........Input voltage minimum of 11 VDC or AC without
dropout
2
Input frequency 47 to 63 Hz
Cable to Transformer .......5 m (16.5 ft) 18 AWG, 3 conductor
Input Connector ...........Euro-style 3-pin removable plug;
5.06 mm terminal block
Allowable Dropout .........150 ms
Environmental
Operating Temperature......-10° to 50°C (14° to 122°F)
Storage Temperature .......-40° to 70°C (-40° to 158°F)
Relative Humidity ..........0 to 95% non-condensing
Regulatory
EMC....................47 CFR, Part 15; ICES-003; EN55022,
Class B; EN61000-3-2; EN61000-3-3;
AS/NZS 3548, Class A; CISPR 22
Immunity ................EN50130-4
Safety...................UL 60950-1; CSA C22.2.60950-1;
EN 60950-1; IEC 60950-1
DATA COMMUNICATION
SensorNet Manchester
Address Range
1 to 254 1 to 64
Bit Rate
230.4 kbps 31 kbps
Network Distance
3
1 km (3,300 ft) per cable segment if repeaters are used
1.5 km (5,000 ft) per cable segment if repeaters are not used 1.5 km (5,000 ft)
Maximum Loads
32 devices per cable segment 3 per run
Cable Segment Repeaters
SensorNet J-Boxes, distribution panels Distribution panels
Topologies
Daisy chain, backbone, or star Daisy chain
Transmission Medium
Single non-polarized unshielded twisted pair UTP
22 AWG (0.326 mm2)
Single twisted pair 18 AWG (0.823 mm2) (Belden 8760),
polarized, Shielded
Connector
Euro-style 3-pin removable plug 3.5 mm (0.14 in)
terminal block, Shield not used Euro-style 3-pin removable plug 3.5 mm terminal block
Connector PIN Assignments
PIN 1 - S+ (orange wire) PIN 2 - S - (yellow wire)
PIN 3 - Ground (Shield not used)
PIN 1 - S+ (black wire) PIN 2 - S- (white wire)
PIN 3 - Ground (Shield used)
Terminating Resistor
120 Ω, switch selectable 120 Ω, switch selectable
Physical Layer
RS-485, transformer-isolated, 2-wire RS-485, transformer-isolated, 2-wire
Data Encoding
FM-0 Manchester
Link Layer Framing
SDLC/HDLC Proprietary
Link Layer Channel
Bi-directional, half duplex Simplex
Collision Avoidance
Polling by primary host controller device N/A
Application Protocol
Proprietary Proprietary
Host Controller Devices
ADMPCPU, ADTT16E Primary Touch Tracker, MegaPower 48
Plus, MegaPower LT, ADACSNET SensorNet USB Module, and
previous American Dynamics SensorNet host/controller products
ADMPCPU, AD2091, MegaPower 48 Plus, and previous
American Dynamics SensorNet host controller products
Secondary Devices
Domes, distribution panels, J-Boxes, secondary Touch Tracker,
and SensorNet I/O unit Domes