Analog way LiveCore LOE016 User manual

LiveCore™ Output Expander -Ref. LOE016
QUICK START GUIDE
Thank you for choosing Analog Way and the LiveCore™ Output Expander. By following these simple steps,
you will be able to set up and use your Powerful mul-screen Seamless Switcher based on Analog Way’s new
LiveCore™ plaorm within minutes. Discover the LiveCore™ Output Expander capabilies and intuive interface
while commanding top-notch presentaons and unleash your creavity for a new experience in show and event
management.
• 1 x LiveCore™ Output Expander (LOE016)
• 1 x Power supply cord
• 1 x Ethernet cross cable (for device control)
• 1 x MCO 10 pin connector
• 1 x Web-based Remote Control Soware included and hosted on the device
• 1 x Rear rack mount kit (the parts are stowed in the packaging foam)
• 1 x Quick start guide*
• 1 x Safety instrucons datasheet
• 3 x LiveCore™ Link cable (OPT-LINK)
* The Quick start guide is also available on www.analogway.com
WHAT’S IN THE BOX
QUICK INSTALL AND SETUP
The LiveCore™ Output Expander uses standard
ethernet LAN networking. To connect the LiveCore™
Output Expander, you rst need to connect it to
the same network than your SmartMatriX Ultra or
Ascender 16 and your computer. To be sure it is on the
same network than your computer, open an internet
browser which supports Flash® player.
Into this internet browser, please enter the IP address
of the LiveCore™ Output Expander displayed on the
front panel screen.
The connecon should start.
Oen, computers are set to DHCP client (automac
IP detecon) mode. You may need to change the
IP address conguraon on your computer before
you can connect. These sengs are found in the
properes for your LAN network adaptor, and vary by
operang system.
The default IP address on the LiveCore™ Output
Expander is 192.168.2.140 with a netmask of
255.255.255.0. Therefore, you can assign your
computer a stac IP address of 192.168.2.100 and
a netmask of 255.255.255.0 and should be able to
connect.
If the connecon is not starng, please see:
• Be sure the computer IP address is on the same
network and subnet as the LiveCore™ Output
Expander.
• Be sure that no two devices have the same IP
address (prevent IP conicts)
• Check your network cable. You will need a crossover
ethernet cable if you are connecng directly from
the LiveCore™ Output Expander to the computer.
If a hub or switch is involved, use straight ethernet
cables.
• For more informaon, please see the user manual
or contact your local technical support.
Once you have successfully connected, the ash
app will automacally download and launch in your
browser. When the two icons in the boom right
corner of the screen turn green, the Web RCS is ready
to use. If you are having trouble syncronizing, try
clearing the cache and refreshing the page (ctrl+F5 in
most browsers):
- LOE016: will turn green when connected
- will turn green when the Web RCS has
nished syncronizing.
CAUTION!
Mounng using only the front
rack ears is sucient for xed
installaons. Addional support,
such as the rear rack support or
slide rails, is required for mobile
applicaons, and recommended
for all.

Contextual
buons
Menu scroll
knob
- 8 x Universal Analog (4 x HD15 & 4 x DVI-A)
- 4 x DVI-I (DVI Dual-Link on outputs #5 & #7)
- 4 x Video Opcal SFP module cage
- 4 x 3G/HD/SD-SDI
4.3’’ TFT color display
Press once and select YES for stand-by
mode. Hold for 3 seconds for stand-by
mode to force power o
USB Plug
Ethernet Plug Tally
Use the 3 link cables to share
inputs/outputs in the addive
modularity conguraon.
Control:
Exit/Menu: Home menu
or back one level
Enter: validate the menu
or command
100-240 VAC; 8A;
50/60Hz; 405W; internal,
autoswitchable
RS232 port:
Reserved for
manufacturer
4 x USB Plugs
Devices sync.:
Used for eect sync in
mul-machine mode.
See User’s Manual for details
- 2 x Universal Analog (HD15 & DVI-A)
- 1 x DVI-I
- 2 x SD/HD/3G SDI
- 1 x RGBs/RGsB/RGB/YPrBr/YC/comp
Analog output
CAUTION:
The user should avoid disconnecng the power source
(AC input) unl the unit is in stand-by mode. Failure to
do this could result in hard drive data corrupon.
The ip address can be changed by the
front panel into the control menu.

CONNECTING SETUP MENU ADDITIVE MODULARITY
To link the 2 units, you need to connect the Web RCS to the
SmartMatriX Ultra or Ascender 16. Please enter the IP address
of the SmartMatriX Ultra or Ascender 16 into your web browser.
Once connected go into then Link.
Switch from SINGLE MODE to LINK MODE. At this point you
should have the LiveCore™ Output Expander IP address and
the connecon status. If any of the cable are red, that means
one of the cable is not well connected. You can refresh the cable
connecon status clicking on the refresh buon.
Please click on PROCEED to launch the addive modularity.
The two units will reboot and the Web RCS will be load again to
nish the process.
Now, with only one Web RCS, you have access to a 12 inputs
and 8 outputs units with 2 monitoring outputs with 2 layers per
screens
Please go into the to congure the screen
posion and start building your show.
You need to connect rst of all units with an RJ45 cable to the
Ethernet hub in order to communicate with the computer.
Then you need to connect a RJ45 STRAIGHT cable for the specic
synchronizaon between the SmartMatriX Ultra or Ascender 16
and the LiveCore™ Output Expander (LOE016), see the red cable
in the schemacs.
Finally, you need to connect the 3 data cables (link cable) from the
rst unit to the second unit. Link1 has to be plug with link1, link2
with link2 etc…
SmartMatriX Ultra
Ascender 16
LiveCore™ Output Expander (LOE016)
RJ-45
OPT-LINK (x3)
LINK 1
LINK 2
LINK 3
RJ-45
OUT IN
Web RCS
(Remote Control Soware)
On Device Master
ETHERNET HUB

For complete details and operaons procedures, please refer to the LiveCore™ unit User’s Manual and our
website for further informaon:
02/12/2015 - LOE016-QSG
Code : 140157
This Analog Way product has a 3 year warranty on parts and labor, back to factory. This warranty does not
include faults resulng from user negligence, special modicaons, electrical surges, abuse (drop/crush),
and/or other unusual damage. In the unlikely event of a malfuncon, please contact your local Analog Way
oce for service.
SETUP
EDIT
LIVE
WARRANTY AND SERVICE
WEB RCS STRUCTURE
Click on SETUP, then go to the precong
secon. The Setup assistant is here to help
you to set up step by step your unit by
following an interacve tutorial.
The EDIT mode is the place where you will
manage all your conguraons. You will
manage your inputs, your layers in terms
of size posion eect etc… your Frames
and Logos. You can save all your screen
conguraons into presets
The LIVE mode is the secon where you
will start operang your show. You can play
preset one aer the other on a real meline
adding some parameters like duraon or
wait for user interacon.
Table of contents
Other Analog way Extender manuals
Popular Extender manuals by other brands

Metra Electronics
Metra Electronics CS-HDIPEXTSR user manual

Smart Cabling & Transmission
Smart Cabling & Transmission IP03PT user manual

MaxiiCopper
MaxiiCopper Vi2401A installation manual

AV-Box
AV-Box TPUH-BYE20 user manual

Clare Controls
Clare Controls CM-BT10-TXRX70 user guide

MuxLab