Electrical Safety
Before installation, ensure that the equipment is intact. Otherwise, electric
shocks or fire may occur.
Do not connect or disconnect power cables when battery is power-on.
Which may cause electric arcs and sparks more overfire or personal injury.
Before connecting a power cable, check the positive or negative connectors are
correct.
Do not parallel connection with different batteries.
Do not connect battery with AC directly.
Do not connect battery with PV wiring directly.
Do not connect batteries in series.
Do not connect battery to faulty or unqualified inverter or charger.
Do not create short circuits with the external connection.
Make sure the grid is cut off and the battery is powered off before
maintenance.
Make sure the earth cable is connected correctly before operation.
Recharge battery in every six months.
Recharge battery within 10 days after battery is fully discharged.
Please engage greater than or equal to two batteries when maximum
charge current is more than 80A.
Make sure battery cable placement is installed correctly.
When the battery is being installed or repaired, make sure the battery is
powered off and using a multimeter to make sure there is no voltage in the positive
and negative terminals.
Please use dedicated insulated tools for install and maintenance.
Please make sure all batteries are power-off when multiple parallel connection.
Please check lights on sequence when battery power-on.
Please make sure communication connection connect correctly with battery
and inverter.
Please make sure ADDS dip switch settings are correctly for single or multiple
batteries.
Please check inverter alarm or SOC reading when there is BMS
communicated with inverter.