AngelEye View User manual

Sant’Osvaldo 1b - 39100 Bolzano - Italy
info@angeleye.it
www.angeleye.tech
+39 0471 1726038
AngelEye Ltd. | Ver: 03/2023 – 2 | Page 1
Technology in The Service of Aquatic Safety

Sant’Osvaldo 1b - 39100 Bolzano - Italy
www.angeleye.tech
+39 0471 1726038
AngelEye Ltd. | Ver: 03/2023 – 2 | Page 1
Technology in The Service of Aquatic Safety
Initial Setup Guide for Accessing AngelEye View
Contents
1. Foreword
2. Configuration Requirements
3. Configuration Procedure

Sant’Osvaldo 1b - 39100 Bolzano - Italy
www.angeleye.tech
+39 0471 1726038
AngelEye Ltd. | Ver: 03/2023 – 2 | Page 2
Technology in The Service of Aquatic Safety
1. Foreword
The AngelEye View system operates on Ethernet-based computer networks via TCP/IP protocol. It requires
an initial configuration of the network protocol in order to be accessed by users via an Internet browser in
Web Server mode.
AngelEye View comes with a default network address:
IP 192.168.10.10
Subnet 255.255.255.0 / Prefix 24
Gateway 192.168.10.1
DNS 8.8.8
This guide will help you configure the above network parameters to operate correctly in your computer
network.

Sant’Osvaldo 1b - 39100 Bolzano - Italy
www.angeleye.tech
+39 0471 1726038
AngelEye Ltd. | Ver: 03/2023 – 2 | Page 3
Technology in The Service of Aquatic Safety
2. Configuration Requirements
Before proceeding with the first configuration, the following information is required:
1. Default network parameters in Chapter 1 of this document.
2. AngelEye View login credentials issued at the time of purchase.
3. Parameters of your LAN network to be assigned to the AngelEye View.
Access to the AngelEye View system is via a computer with the following requirements:
4. Ethernet or Wi-Fi network card to connect to your LAN.
5. Login credentials to be able to change the network parameters of your computer.
6. The computer must be connected to its own LAN network.
7. The AngelEye View system must be connected to the same Ethernet network to which your
computer is connected (Network Switch).
8. Equipped with an Internet browser. Firefox version higher than 70.0 preferred.
Ensure that the browser allows pop-ups to be opened.
Initial access to the AngelEye View system requires your computer to be configured in the same LAN address
class as the default AngelEye View.
The following is a brief guide to configuring your computer in the AngelEye View LAN for Windows and Apple.
Before changing network parameters, it is recommended that you take note of the previous parameters to
reset your computer's network parameters.
Windows (10 or later)
Right-click on the Windows network icon located near the clock, select the "Open Settings" "Network and
Internet" / "Network and Internet Settings" item from the menu that appears, click on the "Status" tab (on
Windows 10) and then on the "Properties" item, corresponding to the name of the network you are
connected to.
On the next screen, locate the heading "IP Assignment", click on the "Edit" button corresponding to it, and
set the drop-down menu proposed to "Manual". Once this is done, move the toggle below the IPv4 heading
to "Enabled" and fill in the proposed fields as follows:

Sant’Osvaldo 1b - 39100 Bolzano - Italy
www.angeleye.tech
+39 0471 1726038
AngelEye Ltd. | Ver: 03/2023 – 2 | Page 4
Technology in The Service of Aquatic Safety
IP address: 192.168.10.11
Note: Check that there is no other device with this IP address in your network.
You can configure your computer with addresses from 192.168.10.11 to 192.168.10.250.
Subnet Mask: 255.255.255.0
Preferred DNS: leave blank
Secondary DNS: leave blank
Click on “Save” and wait a few moments for the network connection to be established with the new
parameters.
MacOS (Ventura 13.2 or later)
Left-click on the "Apple" button at the top left, select the "System Settings..." item, select the "Network" item,
click on "Wi-Fi" or "Ethernet" depending on the type of network connection. Then press the "Details..."
button near the network to which you are connected to open its menu, then on the "TCP/IP" tab. In the same
window, it is possible to change an IP by filling in the proposed fields as follows.
Configure IPv4: Manual
IP address: 192.168.10.11
Note: Check that there is no other device with this IP address in your network.
You can configure your computer with addresses from 192.168.10.11 to 192.168.10.250.
Router: leave blank.
Press OK and wait a few moments for the network connection to be established with the new parameters.

Sant’Osvaldo 1b - 39100 Bolzano - Italy
www.angeleye.tech
+39 0471 1726038
AngelEye Ltd. | Ver: 03/2023 – 2 | Page 5
Technology in The Service of Aquatic Safety
3. Configuration Procedure
Procedure for configuring AngelEye View network parameters:
1. Make sure you have set up what is indicated in Chapter 2 of this document.
2. Access your Internet browser.
3. Type the default IP address of the AngelEye View server into the address bar:
4. 192.168.10.10
5. In the authentication screen enter the login credentials supplied with the AngelEye View.
6. Once you have accessed the AngelEye View homepage, you can access the network parameter
configuration screen via the following icon.
7. In the network configuration screen, you can change the network parameters to be assigned to the
AngelEye View system (see point 3. of Chapter 2. of this document).
8. Confirm the changes by clicking on “Activate”.
9. Reset the parameters of your computer (see chapter 2. of this document).
The AngelEye View system is now ready for use. Please refer to the user manual for guidance on use.
Other manuals for View