Antik GX-5000 User manual

数字前端系
www.antiktech.com
Solution . System .
Service
DigitalHeadend System
GX-5000
Digital Contents Processing Platform
Operation Guide
Version 1.0
GX-5000

数字前端系
Solution . System .
Service
I
About this Guide
Thank you for purchasing the digital TV headend equipment from ANTIK . This operation guide is
intended for technical personnel who use Digital Contents Processing Platform, GX-5000, It
describes the operation of the equipment. In the following table, we provide the document release
history.
Revision History
Contact Us
Address:Čárskeho 10, 04001 Košice, Slovak Republic
Telephone: +421-55-3012345
E-mail:[email protected]
Website: www.antiktech.com
Version Date Document Change
1.0 2017.05 Initial Version
www.antiktech.com
DigitalHeadend System

数字前端系
Solution . System .
Service
II
WARRANTY AND SERVICE
ANTIK warrants to the Purchaser that the Products andany Repaired Products (Repairs) will be free
from defects in material and workmanship for a period of one years from the date of shipment to the
Purchaser.
The obligation of ANTIKunder this warranty is limited to replacing or repairing, at ANTIK's option,Products
or Repairs found by ANTIK to be defective within the warranty period. All such replacements and repairs
shall be performed at facilities designated by ANTIK and shall be performed only after the customer has
received a Return Material Authorization (RMA) number from ANTIK andhas returned the Product to
ANTIK, shipping and insurance prepaid by Purchaser.
The returned Product must be accompanied by the customer's name, address and telephone
number, the modeland serial number of the Product, a statement of the purchase date and a detailed
description of the problem. Products and Repairs returned by Purchaser shall be repaired by ANTIK
using new or refurbishedparts and shall be returned to Purchaser by ANTIK,shipping prepaid by ANTIK.
This warranty shall immediately become null and void if, inANTIK's sole judgment,the Product has been
subject to unauthorized modification, misuse, neglect, accident, improper installation or application,
alteration or neglect in use, storage, transportation or handling, or if the serial number and/or other
Product markings have been removed,defaced or altered.
ANTIK may,at its discretion,perform out-of-warranty repairs at ANTIK facilities in exchange of customary
charges, or offer a written agreement extending the terms of this warranty at a price stated in such
agreement. All repairs performed out of warranty or pursuant to an extended warranty agreement shall
be subject to all of the applicable limitations and procedures of this Agreement.
The above warranties are in lieu of all other warranties, expressed, implied, or statutory or arising by
custom of trade usage, including any warranty of merchantability of fitness for anyunique, special or
express purpose, and of all other obligations of liabilities whether in contract, tort or otherwise
including, without limitation,liability for damages (whether general or special, direct or indirect,
www.antiktech.com
Digital Headend System

数字前端系
www.antiktech.com
Solution . System .
Service
Digital Headend System
III
consequential, incidental, exemplary) or any claim for the loss of profits or business or for damage to
goodwill.
EXTENDED WARRANTY OPTIONS
Please contact Customer Service or your reseller for information on optional extended warranties.
CUSTOMERSERVICE
Support functions provided by ANTIK's Customer Service include complete factory repair for both
in-warranty andout-of-warranty equipment. You can contact your local ANTIK product distributor or
reseller. Or you can call us or write to us for Customer Support.
A Customer Service engineer will answer warranty-related questions, discuss your specific equipment
problems, and when necessary, give you shipping instructions for returning equipment to ANTIK for
repair.
To return a Product for service or repair,you must obtain a RMA number from ANTIK Customer Service.
The following information is required:
Customer name, address, telephone number
Modelnumber
Serial number
Detailed description of problem
All customer-returned units must be shipped to ANTIK freight prepaid,in the original carton or equivalent.
ANTIK is not responsible for damage in transit. All repairs will require return of the entire equipment to
ANTIK. No individual modules will be accepted for repair under this contract.

数字前端系
Solution . System .
Service
4
Table of Contents
1. SAFETY PROTECTION.................................................................................................................................. 1
2. INTRODUCTION.............................................................................................................................................2
2.1. Appearance............................................................................................................................................ 2
2.2. Function Cards introduction..................................................................................................................3
3. LCD Menu.........................................................................................................................................................8
3.1. Main Menu............................................................................................................................................. 10
3.2. Network.................................................................................................................................................. 10
3.3. Misc........................................................................................................................................................ 11
3.4. System.................................................................................................................................................... 12
4. Web Interface...................................................................................................................................................14
4.1. System Status......................................................................................................................................... 14
4.2. Modules.................................................................................................................................................. 14
4.2.1. P01MS(reMUX & Scrambler Extenson Module)..........................................................................14
4.2.2. D01S2(4xDVB-S/S2 Demodulator Module)............................................................................... 14
4.2.3. D02S2(4xDVB-S/S2 Demodulator Module, Support Input Stream Indentifier).........................17
4.2.4. D01T2(4xDVB-C/T/T2 Demodulator Module)...........................................................................17
4.2.5. P01CI(4 x CI De-encryption Module)........................................................................................... 19
4.2.6. C01QAM(8xQAM Modulator Module)...................................................................................... 22
4.2.7. C01MOD(8xQAM/4 x COFDM Modulator Module)................................................................. 27
4.2.8. C01ASI(5 x ASI Input/Output Module).........................................................................................28
4.2.9. P01DA(2 x DS3 Input/2 x DS3 Output/1 x ASI Adaptor Module)............................................... 31
4.2.10. D01PA(2 x Channels Multi-format Signal SD/HD Decoder Module)........................................ 31
4.2.11. P01EC(4xHDMI MPEG-2/H.264 Transcoder/Encoder Module).............................................. 35
4.3. TS over IP...............................................................................................................................................41
4.4. System.................................................................................................................................................... 43
4.5. Remux.................................................................................................................................................... 45
www.antiktech.com
DigitalHeadend System

数字前端系
Solution . System .
Service
1
1. SAFETY PROTECTION
This User Guide is written for operators/users of the GX-5000 to assist in installation and operation. Please
read this User Guide carefully before installation and use of the device.
This equipment is provided with a protective earth grounding incorporated in the power cord. The main plug
shall only be inserted in a socket outlet provided with a protective earth contact. Any interruption of the
protective conductor, inside or outside the device, is likely to make the device dangerous. Do not remove the
covers of this equipment. Hazardous voltages are present within this equipment and may be exposed if the
covers areremoved. Only trained and approved service engineers are permitted to service this equipment.
The supplied AC power cable must be used to power the device. If the power cord becomes damaged, it must
be replaced. No operator serviceable parts inside. For the correct and safe use of the device, it is essential that
both operating and servicing personnel follow generallyaccepted safety procedures in addition to the safety
precautions specified in this manual. Whenever it is likely that safety protection is impaired, the device must be
made in-operative and secured against unintended operation. The appropriate servicing authority must be
informed. For example, safety is likely to be impaired if the device fails to perform the intended measurements
or shows visible damage.
WARNINGS
The mounting environment should be relatively dust free, free of excessive vibration and the ambient
temperature between 10C° to 30C°. Relative humidity of 20% to 80% (non-condensed) is recommended.
Avoid direct contact with water.
Never place the equipment in direct sunlight.
The outside of the equipment may be cleaned using a lightly dampened cloth. Do not use any cleaning
liquids containing alcohol, methylated spirit or ammonia etc.
For continued protection against fire hazard, replace line fused only with same type.
Air intake for cooling is achieved via holes at the side of the device and the fans inside. The air flow should
not be obstructed. Therefore, the device has to be placed on a flat surface, leaving some space at the sides
of the device.
When in operation, the ambient temperature should not exceed the limit of 45C°.
www.antiktech.com
DigitalHeadend System

数字前端系
Solution . System .
Service
2
2. INTRODUCTION
2. 1.
Appearance
GX-5000 appearance is shown as Fig.2-1 GX-5000 Appearance.
Fig.2-1 GX-5000 Appearance
LED Indicators
Thereare 11 LED indicators on GX-5000 front panel which refer to Fig.2-2, including,
1. Power
2. Warning
3. Alarm
4. Module 1-6 Status
5. User-defined A/B (not available in this version, and LED A is defined for P01MS)
Fig.2-2 LED Indicators
Connect to the power supply, the LED indicator of Power keeplighting. The LED indicator of Waring and
Alarm will not be lighted when the device starts and operators normally. These two indicators will turn orange
or red when the device operators abnormally, which prompts the user that an error has occurred.Operating
indicators of Module 1-6 are used to indicate the operating status of slot 1 to 6 respectively, and the indicator of
Warning and Alarm is used to indicate the device status.
www.antiktech.com
DigitalHeadend System
GX-5000

Solution . System .
Service
3
LCD
LCD is mainly for showing unit’s IP address for management. Thereare also some simple menus for main
frame configurations. And user can make the daughter boardreboot via LCD menu. For more details, please
refer LCD menu.
Key pad
Thereare six keys on front panel, UP, Down, Left, Right, Enter and Exit. User can check and setup LCD Menu
with them.
USB
USB is just for firmware update. USB is one of GX-5000 three (USB, Telnet and Web) different types of
firmware update methods. User need to put firmware into USB key root folder, update it through upgrade menu
of LCD.
RJ45
Thereare two RJ45 ports, CA and Control. CA is for scrambler connecting CA server. Control is the
management port of GX-5000.
SFP
Thereare two SFP ports for TS over IP. They can work as backup or independent.
Mini USB
Mini USB is for debugging problem. They are USB to RS232 port actually. Before using this function, user
need to install a RS232, for example putty.exe, to enable this function.
2. 2. Function Cards introduction
2. 2. 1.
P01MS(reMUX & Scrambler Extenson Module)
24 independent TS reMUX's and Scramblers ( s/w option: 48 TS reMUX only, no scrambler)
www.antiktech.com
DigitalHeadend System

数字前端系
Solution . System .
Service
4
15Gbps data processing capability
Compliant with ISO13818 & EN300 468
MEPG/H.264 TS re-Multiplexing & Scrambling
Local & Remote CAS multi-crypt
DVB CAS & BISS
PID filtering, remapping, pass through & mapping
Insert & Edit PSI/SI tables
EIT pass through or re-construction
PCR re-stamp & calibrate
Self temperature monitoring
2. 2. 2. D01S2(4 x DVB-S/S2 Demodulator Module)
4 x F type Female, 75
Ω
Input Frequency Range: 950 ~ 2150 MHz
Input RF level: -65dBm ~ -25dBm
Symbol Rate: 2 ~ 45MSps
Roll Off factor: 0.35(DVB-S QPSK), 0.35/0.25/0.2(DVB-S2 8PSK)
FEC Puncture Rate: 2/3, 3/4, 3/5, 5/6, 8/9, 9/10(DVB-S2 8PSK), 1/2, 2/3, 3/4, 5/6, 6/7, 7/8(DVB-S QPSK)
Support BISS-1/E de-encryption(up to 40 PIDs de-encryption per tuner input)
Support T2-MI(up to 8 PLP IDs demodulation per tuner input)
2. 2. 3. D02S2(4 x DVB-S/S2 Demodulator Module, Support Input Stream Indentifier)
4 x F type Female, 75
Ω
Input Frequency Range: 950 ~ 2150 MHz
Input RF level: -65dBm ~ -25dBm
Symbol Rate: 2 ~ 45MSps
Roll Off factor: 0.35(DVB-S QPSK), 0.35/0.25/0.2(DVB-S2 8PSK)
FEC Puncture Rate: 2/3, 3/4, 3/5, 5/6, 8/9, 9/10(DVB-S2 8PSK), 1/2, 2/3, 3/4, 5/6, 6/7, 7/8(DVB-S QPSK)
Support BISS-1/E de-encryption(up to 40 PIDs de-encryption per tuner input)
Support T2-MI(up to 8 PLP IDs demodulation per tuner input)
www.antiktech.com
DigitalHeadend System

数字前端系
Solution . System .
Service
5
ISI ID: 1 ~ 255 user configurable
2. 2. 4. D01T2(4 x DVB-C/T/T2 Demodulator Module)
4 x F type Female, 75Ω
Full compliant for DVB-T2 v1.3
Input Frequency, 48 ~ 860 MHz(DVB-C), 104 ~ 862 MHz(DVB-T/T2)
Input Level, -15~ 15dBm(DVB-C), -70 ~ -20dBm(QEF, DVB-T/T2)
Symbol Rate, 1 ~ 7MSps(ITU J.83 Annex A DVB-C)
Constellation, 16/32/64/128/256 QAM(DVB-C), QPSK/16 QAM/64 QAM(DVB-T), QPSK/16 QAM/64
QAM/256 QAM(DVB-T2)
Bandwidth, 6/7/8 MHz
FFT Mode, 2K/8K(DVB-T), 1K/2K/4K/8K/16K/32K(DVB-T2)
Guard Interval, 1/4, 1/8, 1/16, 1/32(DVB-T) 1/4, 5/32, 1/8, 5/64, 1/16, 1/32, 1/64, 1/128(DVB-T2)
FEC Code Rate, 1/2, 2/3, 3/4, 5/6, 7/8(DVB-T) 1/2, 3/5, 2/3, 3/4, 4/5, 5/6(DVB-T2)
2. 2. 5. P01CI(4 x CI De-encryption Module)
4 x Independent Common Interface(DVB-CI)slots
Multiple programs CSA or BISS-1/E De-encryption
CAM watchdog
Compatible with most of popular CA systems
2. 2. 6. C01QAM(8 x QAM Modulator Module)
2 x F type Female, 75
Ω
(1 x main output,1 x -20dB monitor output)
2 groups of 4 adjacent channel carriersQAM RF output
ITU-T J.83 Annex A, C
16QAM, 32QAM, 64QAM,128QAM,256QAM
RF output range: 48 ~ 996MHz, step by 1KHz
Symbol rate: 2.5 ~ 6.99MBauds
RF total output level: 94 ~ 120dBuV(111dBuV eachcarrier)
MER > 36dB
www.antiktech.com
DigitalHeadend System

数字前端系
Solution . System .
Service
6
BER < 10E-9
Spurious rejection > 55dB
Output return loss -10dB
2. 2. 7. C01MOD(8 x QAM/4 x COFDM Modulator Module)
2 x F type Female, 75
Ω
(1 x main output,1 x -20dB monitor output)
Support QAM/COFDM Modulation Mode(cannot work at the same time)
2 groups of 4 adjacent channel carriersQAM RF output, 2 groups of 2 adjacent channel carries COFDM
RF output
RF output range: 48 ~ 996MHz, step by 1KHz
Symbol rate: 2.5 ~ 6.99MBauds
RF total output level: 94 ~ 120dBuV(111dBuV eachcarrier)
Spurious rejection > 55dB
Output return loss -10dB
QAM Modulation, support ITU-T J.83 Annex A, C
Constellation, 16QAM, 32QAM, 64QAM,128QAM,256QAM
MER > 36dB, BER < 10E-9
2. 2. 8. C01ASI(5 x ASI In/Out Module)
5 x BNC Female, 75Ω
Standard: DVB-ASI, EN50083-9
Up to 5 x ASI Input
Up to 5 x ASI Output
Maximum bit rate(each ASI): 213Mbps
Minimum accepting sensitivity: 200mV
Maximum input Voltage: 880mV
Support T2-MI (In the T2-MI mode, ASI-5 is configured to input which can process 4 PLP ID, ASI-1 to
ASI-4 are configured to output which can select PLP ID TS to output via Web)
www.antiktech.com
DigitalHeadend System

数字前端系
Solution . System .
Service
7
2. 2. 9.
P01DA(2 x DS3 Input/2 x DS3 Output/1 x ASI Adaptor Module)
5 x BNC Female, 75
Ω
Standard: DVB-ASI, EN50083-9 / ITU-T G.703
Frame Structure: ITU-T G.752 / ITU-T G.804
ASI Input or Output can be switched
Bit rate: 44.736Mbps
2. 2. 10. D01PA(2 x Channels Multi-format Signal SD/HD Decoder Module)
2xHDMI 1.3(up to 1080i), 1 x D-sub 15 female(can be translated 2 x CVBS via cable)
Video Format: MPEG-2(MP@ML for SD, MP@HL for HD), MPEG-4/H.264 AVC Part 10(MP@L3 for
Audio Format: MPEG-1 Layer II, AAC-LC, HE AAC V1/V2
Aspect Ratio: 16:9, 4:3 Self-adaptation
Resolution and Frame Rate: 1080ix30, 1080ix29.97, 1080ix25, 720px60, 720px59.94, 720px50, 576ix25,
480ix29.97
Video PID Bit Rate: < = 50Mbps
2. 2. 11. P01EC(4 x HDMIMPEG-2/H.264 Transcoder/Encoder Module)
4xHDMI Input interface
Compliant with H.264/AVC Baseline, Main & High Profile @ L4.0 or less & MPEG-2 MP@ML
Independent Transcoding/Encoding mode control
Video Input Resolution: 1080i, 720p, 576i, 480i.
Support video resoultion downscaling(vertical & horizontal adjustable respectively).
Audio Coding: MPEG-1 Layer II, MPEG-2/4, AAC-LC/HE-AAC
Support VBR & CBR mode
Sampling Format: 4:2:0, 10-bit, YCbCr
Compression Bit Rate: 300K ~ 20Mbps
Aspect Ratio: 4:3, 16:9
www.antiktech.com
DigitalHeadend System

数字前端系
Solution . System .
Service
8
3. LCD Menu
There is a LCD Menu for users to configure main frame and front interfaces. User can press enter key to start to
setup the unit. The LCD menu overview showed as below:
www.antiktech.com
DigitalHeadend System

数字前端系
www.antiktech.com
Solution . System .
Service
Digital Headend System
9

数字前端系
Solution . System .
Service
10
3.1. Main Menu
The LCD will show GX-5000 and management IP address when it boot up. User can press any key of front
panel to enter Main menu. Main menu includes 3 submenus, Network, Misc and System.
3.2. Network
Network menu includes IP address, Subnet Mask, Gateway, MAC Address and Web GUI Login for
management RJ45 port. User can see the below graph as reference. MAC address is read only. Web GUI Login
is for setup or reset web browser login ID and password, especially users forgot the ID or password.
www.antiktech.com
DigitalHeadend System
GX-5000

数字前端系
Solution . System .
Service
11
3.3. Misc
This menu includes several unit’s status, Date, Time, Temperature, Fan status, Power supply, Error Operate and
Device label. User can setup Date and Time to display via front panel. Temperature is unit inside temperature.
Fan status will show error if any fan does not work. Power supply is the dual power supply’s status. It will show
error information when the power supply doesn’t work. Error Operate is to reset warned errors. Device label is
for setting up unit names which will show on LED and Web browser.
www.antiktech.com
DigitalHeadend System

数字前端系
Solution . System .
Service
12
3.4. System
System menu includes these sub-menus, S/N, Version, Reset Module, Switch USB-RS, Factory Settings and
Machine Settings. S/N is the identification of the unit and it is an unique series number for each unit. It helps to
verify if the unit comes original or not. Version is the information of firmware of the main frame. Reset Module
is the function for reset daughter cards. Switches USB-RS is for setting up debug information output port.
Factory Settings is for reset all settings to factory default. Machine Settings is limited for users.
www.antiktech.com
DigitalHeadend System

数字前端系
Solution . System .
Service
13
www.antiktech.com
DigitalHeadend System

数字前端系
Solution . System .
Service
14
4. Web Interface
Web browser is the main management interface of GX-5000. User can check the unit working status, setup
and reset it etc. The suggestion browsers are Chome, IE version 11 or higher.
4.1. System Status
This is the page for main frame working status. It includes hardware working temperature,fans speed, power
supply status and TS over IP ports status. If power status shows faulty, it means that the power is crashed or not
installed.
4.2. Modules
4.2.1. P01MS
(
reMUX & Scrambler Extenson Module
)
Under development!!!
4.2.2. D01S2(4 x DVB-S/S2 Demodulator Module)
The D01S2 is a 4 independent channels DVB-S/S2 demodulator module, userscan setup them separately. And
this card supports both BISS-1 and BISS-E decryption function too. Thereare 8 preset BISS keys for each
transport stream.
www.antiktech.com
DigitalHeadend System

数字前端系
Solution . System .
Service
15
Tuner Status
Tuner configure
Menu Name Description
LNB LO Frequency
To configure the local oscillator frequency according to the right satellite,
its range is from 1000 to 26,500MHz.
Satellite Frequency
To configure the satellite down link frequency according to the right
satellite, its range is from 1000 to 26,500MHz.
Symbol Rate
To configure the symbol rate of QPSK signal, its range is from 1000 to
www.antiktech.com
DigitalHeadend System
Other manuals for GX-5000
1
Table of contents
Popular Modulator manuals by other brands

Boss Audio Systems
Boss Audio Systems FM - MOD owner's manual

ZeeVee
ZeeVee HDb2000 quick start guide

ITS Telecom
ITS Telecom EKSELANS MD HD EASY user manual

Philips
Philips TDA6800 datasheet

Pico Macom
Pico Macom PLM860SAW Installation and operation manual

dig-MOD
dig-MOD HD-1605 User guide & installation manual