manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. APART
  6. •
  7. Horn
  8. •
  9. APART EN-H10-G User manual

APART EN-H10-G User manual

Other APART Horn manuals

APART EN-H15-G User manual

APART

APART EN-H15-G User manual

APART HM25-G User manual

APART

APART HM25-G User manual

Popular Horn manuals by other brands

Klenn Air Horns JL-JK-OBA installation manual

Klenn Air Horns

Klenn Air Horns JL-JK-OBA installation manual

Vixen Horns VXO8350 installation guide

Vixen Horns

Vixen Horns VXO8350 installation guide

Elk Products 45 user manual

Elk Products

Elk Products 45 user manual

Cooper Wheelock DB3 Series specification

Cooper Wheelock

Cooper Wheelock DB3 Series specification

Altec Lansing 811B HF HORN manual

Altec Lansing

Altec Lansing 811B HF HORN manual

RF Elements UltraHorn CC Series quick start guide

RF Elements

RF Elements UltraHorn CC Series quick start guide

Edwards Signaling 869DSTR-G1 Series Installation sheet

Edwards Signaling

Edwards Signaling 869DSTR-G1 Series Installation sheet

Valcom V-1050C user manual

Valcom

Valcom V-1050C user manual

Valcom V-1030C user guide

Valcom

Valcom V-1030C user guide

Valcom VIP-130AL-SA quick start guide

Valcom

Valcom VIP-130AL-SA quick start guide

Toa LE-M124 Specifications

Toa

Toa LE-M124 Specifications

AUSTRALIAN MONITOR MH30 brochure

AUSTRALIAN MONITOR

AUSTRALIAN MONITOR MH30 brochure

Valcom V-1069A datasheet

Valcom

Valcom V-1069A datasheet

Valcom V-9947A quick start guide

Valcom

Valcom V-9947A quick start guide

Vixen Horns VXO8805/3311C installation guide

Vixen Horns

Vixen Horns VXO8805/3311C installation guide

Federal Signal Corporation 350 Installation and maintenance instructions

Federal Signal Corporation

Federal Signal Corporation 350 Installation and maintenance instructions

Electro-Voice MH4020AC Specifications

Electro-Voice

Electro-Voice MH4020AC Specifications

Dynacord 18" Full-W Vented Bass Horn alpha B6 Specifications

Dynacord

Dynacord 18" Full-W Vented Bass Horn alpha B6 Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

EN-H10-GHORN SPEAKER
The Apart-Audio EN-H10-G is a powerful horn speaker made of UV and impact resistant ABS (RAL 7035 equivalent), (UL94V0), equipped with a compression driver and
a multitap 100 volt transformer, all certified according EN 54-24. Ip66 makes it the ideal choice for industrial applications.
The unit is equipped with a ceramic speaker line connector block, junction box, thermal fuse and stainless installation bracket. The unit can be used as a low impedance
speaker by setting the power selector switch to the 20 ohms position. Lo-Z impedance and power: 20 ohms, 10 watt.
The highlights are: Ip66, weather resistant ABS, junction box, lo-Z and 100 volt.
Not included: cable gland for the cable from the power amplifier to the junction box.
Technical specifications
Speaker type compression driver
Dimensions (Ø x d) 142 x 210 mm
Colour RAL 7035
100 volt transformer power taps 10/5/2.5/1,25 watts
Lo-Z impedance 20 ohms
Lo-Z power 10 watt
Frequency response (-10 dB, IEC268-5) 418 - 12400 Hz
Frequency range 370 - 13000 Hz
Dispersion angle -6 db, 500 Hz / 1 kHz / 2 kHz / 4 kHz 360° / 235° / 90° / 46°
SPL 1W / 1m (IEC268-5) 98.0 dB
SPL 1W / 4m (IEC268-5) 86.0 dB
SPL Pmax / 4m (IEC268-5) 96.0 dB
SPL Pmax / 1m (IEC268-5) 108 dB
Sensitivity EN54-24, 1W / 4m
IP classification 66
Chassis material ABS plastic
Mounting instructions
1. Install the bracket and junction box on a wall or ceiling.
2. Connect the speaker cable to the power amplifier.
3. Set the power selector switch at the rear of the speaker as required.
EN 54-24
certified
Safety precautions
Warranty info
Legal info
• Keep this manual for future reference.
• When making the hole in your mounting panel to mount the Apart
speaker, make sure there is sufficient clearance behind the panel
(no obstructions like A/C channels, power lines etc, ...).
• Take care of your speaker wires, they should be free of damage. Damaged
speaker wires may result in poor sound quality and can damage amplifiers.
• Only use accessories specified by the manufacturer.
• Make sure the mounting panel can support the speaker's weight.
• Use a sufficient amount of speakers to avoid dead spots.
• No main power shall be connected to the loudspeakers, doing so will
damage the speaker.
• This apparatus should only be serviced by qualified personnel. If not
serviced by qualified personnel, warranty may be void.
• Use cable of the right gauge, certainly for long runs.
• Use cables with clear color indication and maintain polarity throughout
the whole system.
• Avoid loud feedback from microphones, this can damage your speaker.
• Please check the unit's condition after unpacking. If the outside of the
carton box has been damaged, inform your shipper immediately.
Apart Audio warrants this product to be free of defects in material and
workmanship for a period of one year for parts and for a period of one year
for labor from the date of original end-user purchase. This warranty is valid
only for the original end-user and cannot be transferred.
During the warranty period Apart Audio or one of its authorized service
partners shall either repair or replace any product, free of charge, that proves
to be defective on inspection by Apart Audio or its authorized service
representative.This warranty does not include, damages or product faults due
to abuse, misuse or faulty installation.
Audioprof nv
Industriepark Brechtsebaan 8 bus 1, 2900 Schoten - Belgium
Company names, product names and trademarks are property of their
respective owners. Apart-Audio specifications are subject to change without
notice.
Certificate No.: 1438/CPD/XXXX
Please note: to obtain the frequency response requested in EN54-24,
an equalizer has to be integrated into the signal path.
74.5 dB
EN-H10-GHORN SPEAKER
To operate the product according to the EN 54-24 standard, an equalizer has to be inserted into the signal path, which has a
frequency response as specified in the following table.
Since horn type speakers should not be driven with full power below their low end response, adding a high-pass filter 200
Hz/-3 dB with a 6 dB/octave slope is recommended (shelving filter).
EN 54-24
certified
Frequency
[Hz]
Relative Level to
1 kHz for EN-H10-G
[dB]
Tolerance
[dB]
100 -12.9 +2/-10
125 -12 +2/-10
160 -12.2 +2/-10
200 -9.2 +2/-10
250 -3.2 +2/-10
315 +5.0 +2/-10
400 +6.6 +2/-10
500 +6.0 +2/-4
630 +4.6 +2/-2
800 +8.5 +2/-2
1k 0 +2/-2
1.25k -2.4 +2/-2
1.6k +0.4 +2/-2
2k +0.9 +2/-2
2.5k +2.3 +2/-2
3.15k +4.0 +2/-2
4k +6.2 +2/-2
5k +10.0 +2/-2
6.3k +12.1 +2/-2
8k +13.8 +2/-4
10k +13.7 +2/-6