ON
VALVE OPEN
OFF
SET
RUN
SHIFT UNITS
STOP
OFF
MEMORY
TARE
FLOW
HOLD
CANCEL LAMP
kg
oz
Lb
ACS-100SO
PROGRAMMABLE
REFRIGERANT SCALE
[email protected]https://aprvtiotech.com/ +1 713 701 1986 [email protected]https://aprvtiotech.com/ +1 713 701 1986
1. High visibility LCD display.
2. Three units of measure options(kg/oz/lbs)
3. Backlight for the display.
4. Automatic shut-off after 10 minutes of non-use; backlight will shut off after
3 minutes of non-use or use.
5. Memory feature allows storage of up to 100 charge/recovery programs.
6. Compact, portable, battery operated design.
Introduction
Features
Model ACS-100SO
Max weighting 100kg(220lbs)
Resolution +/-0.2oz/0.01 lbs/5g
Accuracy +/-0.5% of reading
Operating temperature 32℉to 122℉(0~50°C)
Storage temperature -4℉to 158℉(-20~70°C)
Three modes kgs, lbs and oz
Platform size 23cm*23cm(9" x 9")
Parameters
VALVE OPEN
kg
oz
RUN
SET
Ib
HOLD ZERO TARE AUTO
Lb
①
②
③
④
⑤
⑥ ⑦ ⑧
⑨
⑩
11
12
① Valve indicator light(ON/OFF)
② Main numeric display
③ Run mode indicator
④ ”Negative indicator(indicates weight being removed form platform)
⑤
⑥
⑦
⑧
11
12
⑨
⑩
Item Function
Programable weight set
Hold mode indicator
Display “TARE/ZERO”
Auto mode indicator
Indicate units for LBS
Indicate units for KG
Indicate units for OZ
Battery charge indicator
The ACS-100SO Programmable refrigeant scale allows
quick, efficient and automatic charging/recovery of
refrigerant from air conditioning or refrigerant systems.
The unit is portable and has a weight capacity of up to
220 lbs or 100kg. It includes 1/4”male flare and 1/2”ACM
fitting to allow connection to all standard charging ma-
nifolds and refrigerant cylinders.
[email protected]https://aprvtiotech.com/ +1 713 701 1986 [email protected]https://aprvtiotech.com/ +1 713 701 1986
7. Fail safe feature:
unit is designed with a fail safe feature that will close the valve in the event
of lost power due to low battery voltage or if the unit is inadvertently
turned off.
8. “FULL“ display when the weight exceeds the specified range.
1. Place the unit on a firm and level surface. The platform and control box
can be used in the case or they can be used outside of the case.
2. Remove the battery cover from the rear of the box by compressing the tab
at the base of the battery cover.
3. Insert(5)”AA” batteries.Replace the battery cover by aligning tabs and snap
back into place.
4. Turn the unit power on by pressing the button.
5. Select the unit of measure by pressing the button .(kg/lbs/oz)
6. Press the button to activate the backlight. Press the button again
to deactivate the backlight.
NOTE: TO prevent damage to the ACS-100SO do not leave dead batterise in
the control box. Remove the batteries if the unit will not be used for an ext-
ended period of time.
CAUTION: If the platform is used in the case, make certain that nothing tou-
ches the case, controls and platform or false readings may occur.
1. Turn the unit on by pressing the button .
2. Choose the type of measurement by pressing the button.(KG/LBS/OZ)
The unit of measure can be changed at any time except when programming
a charge/recovery.
3. Press the button to remove last operation value.
4. Place the cylinder in the center of the platform. The gross weight will be
displayed.
5. When complete, remove the cylinder and press the button to turn the
unit off.
Charge/recovery programming
There are two charging types of operation. Charging according to a set
1. Pressing the button while in weighing mode, holds the current weight
value even you remove the weighing object unit the button is pressed
again.
2. In the process of charge and recovery, press the button, the recovery
and value will remain display when the refrigerant of cylinder used up or full
and then close the cylinder valve,reconnect the hose and open the valve
memory value or charging to a manually set value.
Charging to a set memory value
1. Turn the unit on by pressing the button. Unit will display the value of
the last operation when you not first time to use.
2. Place the cylinder on the scale before charging.Connect the cylinder valve
to the unit with appropriate charging hoses. After proper connection, slowly
open cylinder valve.
3. Press the button. The unit will display the value of the last operation
and a digit value will be flashing.
4. To change the value, press the button to get to the specific digit value
to change.
5. Press the or button to change the value. Press the button of
or more than two seconds, the value reads will be quickly fluctuated.
6. Press the button to store the programmed amount(0-99 codes)
7. To run the progrm, press the button. When the valve indicator
light which in the top left of the control turns. it means the valve is opened,
meanwhile the performance of charging and recovery is started. When the
program is completed, the valve will be closed automatically, the valve ind-
icator light will be turned off, then the unit will beep to notice the users.The
amount of refrigerant charged/recovered will remain displayed.
8. Press the button to go back to the weight status.
9. When operation is complete. disconnect the refrigerant hose. remove the
cylinder and turn off the unit.
Charging to a manually set value:
1. Turn the unit on by pressing the button.
2. Place the cylinder on the scale before charging.Connect the cylinder valve
to the unit with appropriate charging hoses. After proper connection, slowly
open cylinder valve.
3. Press the button.
4. To change the value, press the button to get to the specific digit value
to change.
5. Press the or button to change the value.
6. To run the progrm, press the button.
Weight measurements
HOLD
Set up
UNITS
UNITS
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
LAMP LAMP
LAMP
LAMP
OFF
TARE
SET
CANCEL
SET
CANCEL
SHIFT
SHIFT
HOLD
LAMP
HOLD
HOLD
HOLD
HOLD
HOLD
MEMORY
RUN
STOP
RUN
STOP
RUN
STOP
[email protected]https://aprvtiotech.com/ +1 713 701 1986 [email protected]https://aprvtiotech.com/ +1 713 701 1986
again. When you complete all the process, press the button to continue
the charge or recovery program.(The last value is the total value of two times
charge/ recovery program.)
1. Turn the unit on by pressing the button.
2. Follow steps 3 through 5 under “charging to a set memory value” instruc-
tion.
3. After press the button, There should be a “p xx” displayed on the face
of the control box. You can write down the value on the MEMORY VALUE
SHEET(1-99 codes) in the case.
4. To recall a stored program number, press the buttton while in the
weighing mode and enter the memory code number. Press the button
again.
5. Press the button to begin the charge/recovery operation.
6. To stop the charge/recovery operation, press the button.
1. Immediately stop all charge/recovery operation and remove the cylinder
if the specified range is exceeded and the unit displays”EULL” .
2. Change batteries when the battery indicator flashes in the top right-hand
corner of the display.
3. Remove batteries form unit if the unit will not be used for a long time.
4. Clean filters by:
Press the button to turn unit on.
Press the button and enter an amount, press again.
Press the button to open the valve.
Connect the source of clean, dry shop or compressed air to the “OUTLET”
port (right port)POINT:Ensure the “INLET” port (left port) is pointed away
form any person in the area.
Turn the air source on and allow the air to run backwards through the
valve for several seconds.
Memory feature
Maintenance
ON
OFF
ON
OFF
SET
CANCEL
SET
CANCEL
HOLD
RUN
STOP
RUN
STOP
RUN
STOP
MEMORY
MEMORY
MEMORY

Other APRVTIO Scale manuals

APRVTIO ACS-50A User manual

APRVTIO

APRVTIO ACS-50A User manual

APRVTIO ACS-100S User manual

APRVTIO

APRVTIO ACS-100S User manual

APRVTIO ACS-100SB User manual

APRVTIO

APRVTIO ACS-100SB User manual

Popular Scale manuals by other brands

Okoia MPS6 operating instructions

Okoia

Okoia MPS6 operating instructions

Charder R230 user manual

Charder

Charder R230 user manual

Goddess SCA415 Profi life instruction manual

Goddess

Goddess SCA415 Profi life instruction manual

ETEKCITY Apex EFS-A591S-KUS manual

ETEKCITY

ETEKCITY Apex EFS-A591S-KUS manual

Turtle Tarriss JETSETTER quick start guide

Turtle

Turtle Tarriss JETSETTER quick start guide

Yamato Just NAVI J-101W Operation manual

Yamato

Yamato Just NAVI J-101W Operation manual

Rice Lake MSI-4260 IS Technical manual

Rice Lake

Rice Lake MSI-4260 IS Technical manual

Jata hogar Analizador Corporal 523 Instructions of use

Jata hogar

Jata hogar Analizador Corporal 523 Instructions of use

Gram ACUREX TXM Quick assembly guide

Gram

Gram ACUREX TXM Quick assembly guide

NOVELCA PRATICO 33001244 quick start guide

NOVELCA

NOVELCA PRATICO 33001244 quick start guide

Tanita WB-380 instruction manual

Tanita

Tanita WB-380 instruction manual

Klarstein 10030612 manual

Klarstein

Klarstein 10030612 manual

Hopkins EZ Carry 440LB user guide

Hopkins

Hopkins EZ Carry 440LB user guide

Teesa TSA0808 owner's manual

Teesa

Teesa TSA0808 owner's manual

DCOOK 8084001 instruction manual

DCOOK

DCOOK 8084001 instruction manual

Rice Lake BenchMark MS Technical manual

Rice Lake

Rice Lake BenchMark MS Technical manual

Redmond RS-708-E user manual

Redmond

Redmond RS-708-E user manual

Conair WWSLB11EC user manual

Conair

Conair WWSLB11EC user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.