7. Fail safe feature:
unit is designed with a fail safe feature that will close the valve in the event
of lost power due to low battery voltage or if the unit is inadvertently
turned off.
8. “FULL“ display when the weight exceeds the specified range.
1. Place the unit on a firm and level surface. The platform and control box
can be used in the case or they can be used outside of the case.
2. Remove the battery cover from the rear of the box by compressing the tab
at the base of the battery cover.
3. Insert(5)”AA” batteries.Replace the battery cover by aligning tabs and snap
back into place.
4. Turn the unit power on by pressing the button.
5. Select the unit of measure by pressing the button .(kg/lbs/oz)
6. Press the button to activate the backlight. Press the button again
to deactivate the backlight.
NOTE: TO prevent damage to the ACS-100SO do not leave dead batterise in
the control box. Remove the batteries if the unit will not be used for an ext-
ended period of time.
CAUTION: If the platform is used in the case, make certain that nothing tou-
ches the case, controls and platform or false readings may occur.
1. Turn the unit on by pressing the button .
2. Choose the type of measurement by pressing the button.(KG/LBS/OZ)
The unit of measure can be changed at any time except when programming
a charge/recovery.
3. Press the button to remove last operation value.
4. Place the cylinder in the center of the platform. The gross weight will be
displayed.
5. When complete, remove the cylinder and press the button to turn the
unit off.
Charge/recovery programming
There are two charging types of operation. Charging according to a set
1. Pressing the button while in weighing mode, holds the current weight
value even you remove the weighing object unit the button is pressed
again.
2. In the process of charge and recovery, press the button, the recovery
and value will remain display when the refrigerant of cylinder used up or full
and then close the cylinder valve,reconnect the hose and open the valve
memory value or charging to a manually set value.
Charging to a set memory value
1. Turn the unit on by pressing the button. Unit will display the value of
the last operation when you not first time to use.
2. Place the cylinder on the scale before charging.Connect the cylinder valve
to the unit with appropriate charging hoses. After proper connection, slowly
open cylinder valve.
3. Press the button. The unit will display the value of the last operation
and a digit value will be flashing.
4. To change the value, press the button to get to the specific digit value
to change.
5. Press the or button to change the value. Press the button of
or more than two seconds, the value reads will be quickly fluctuated.
6. Press the button to store the programmed amount(0-99 codes)
7. To run the progrm, press the button. When the valve indicator
light which in the top left of the control turns. it means the valve is opened,
meanwhile the performance of charging and recovery is started. When the
program is completed, the valve will be closed automatically, the valve ind-
icator light will be turned off, then the unit will beep to notice the users.The
amount of refrigerant charged/recovered will remain displayed.
8. Press the button to go back to the weight status.
9. When operation is complete. disconnect the refrigerant hose. remove the
cylinder and turn off the unit.
Charging to a manually set value:
1. Turn the unit on by pressing the button.
2. Place the cylinder on the scale before charging.Connect the cylinder valve
to the unit with appropriate charging hoses. After proper connection, slowly
open cylinder valve.
3. Press the button.
4. To change the value, press the button to get to the specific digit value
to change.
5. Press the or button to change the value.
6. To run the progrm, press the button.
Weight measurements
HOLD
Set up
UNITS
UNITS
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
LAMP LAMP
LAMP
LAMP
OFF
TARE
SET
CANCEL
SET
CANCEL
SHIFT
SHIFT
HOLD
LAMP
HOLD
HOLD
HOLD
HOLD
HOLD
MEMORY
RUN
STOP
RUN
STOP
RUN
STOP